987 resultados para electronic identification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Travel time in an important transport performance indicator. Different modes of transport (buses and cars) have different mechanical and operational characteristics, resulting in significantly different travel behaviours and complexities in multimodal travel time estimation on urban networks. This paper explores the relationship between bus and car travel time on urban networks by utilising the empirical Bluetooth and Bus Vehicle Identification data from Brisbane. The technologies and issues behind the two datasets are studied. After cleaning the data to remove outliers, the relationship between not-in-service bus and car travel time and the relationship between in-service bus and car travel time are discussed. The travel time estimation models reveal that the not-in-service bus travel time are similar to the car travel time and the in-service bus travel time could be used to estimate car travel time during off-peak hours

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Graphene has promised many novel applications in nanoscale electronics and sustainable energy due to its novel electronic properties. Computational exploration of electronic functionality and how it varies with architecture and doping presently runs ahead of experimental synthesis yet provides insights into types of structures that may prove profitable for targeted experimental synthesis and characterization. We present here a summary of our understanding on the important aspects of dimension, band gap, defect, and interfacial engineering of graphene based on state-of-the-art ab initio approaches. Some most recent experimental achievements relevant for future theoretical exploration are also covered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an adaptive metering algorithm for enhancing the electronic screening (e-screening) operation at truck weight stations. This algorithm uses a feedback control mechanism to control the level of truck vehicles entering the weight station. The basic operation of the algorithm allows more trucks to be inspected when the weight station is underutilized by adjusting the weight threshold lower. Alternatively, the algorithm restricts the number of trucks to inspect when the station is overutilized to prevent queue spillover. The proposed control concept is demonstrated and evaluated in a simulation environment. The simulation results demonstrate the considerable benefits of the proposed algorithm in improving overweight enforcement with minimal negative impacts on nonoverweighed trucks. The test results also reveal that the effectiveness of the algorithm improves with higher truck participation rates in the e-screening program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined primary school teachers’ knowledge of anxiety and excessive anxiety symptoms in children. Three hundred and fifteen primary school teachers completed a questionnaire exploring their definitions of anxiety and the indications they associated with excessive anxiety in primary school children. Results showed that teachers had an understanding of what anxiety was in general but did not consistently distinguish normal anxiety from excessive anxiety, often defining all anxiety as a negative experience. Teachers were able to identify symptoms of excessive anxiety in children by recognizing anxiety-specific and general problem indications. The results provided preliminary evidence that teachers’ knowledge of anxiety and anxiety disorders does not appear to be a barrier in preventing children’s referrals for mental health treatment. Implications for practice and directions for future research are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The onset of Personally Controlled Electronic Health Records in Australia demand healthcare decision making processes to comprise, understand and accept electronic health records (EHR). Nurses play a key, central role in the healthcare decision making process and their perceptions and attitudes of EHRs are significant [1], which develop during their academic life. However, studies aimed at nursing students’ attitudes of EHRs are very limited [2-4]. A proper understanding of these attitudes and how they evolve with academic progress is important. This paper presents results from a survey conducted at a leading University in Queensland, Australia as a first step to filling this gap.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context Patients with venous leg ulcers experience multiple symptoms, including pain, depression, and discomfort from lower leg inflammation and wound exudate. Some of these symptoms impair wound healing and decrease quality of life (QOL). The presence of co-occurring symptoms may have a negative effect on these outcomes. The identification of symptom clusters could potentially lead to improvements in symptom management and QOL. Objectives To identify the prevalence and severity of common symptoms and the occurrence of symptom clusters in patients with venous leg ulcers. Methods For this secondary analysis, data on sociodemographic characteristics, medical history, venous history, ulcer and lower limb clinical characteristics, symptoms, treatments, healing, and QOL were analyzed from a sample of 318 patients with venous leg ulcers who were recruited from hospital outpatient and community nursing clinics for leg ulcers. Exploratory factor analysis was used to identify symptom clusters. Results Almost two-thirds (64%) of the patients experienced four or more concurrent symptoms. The most frequent symptoms were sleep disturbance (80%), pain (74%), and lower limb swelling (67%). Sixty percent of patients reported three or more symptoms at a moderate-to-severe level of intensity (e.g., 78% reported disturbed sleep frequently or always; the mean pain severity score was 49 of 100, SD 26.5). Exploratory factor analysis identified two symptom clusters: pain, depression, sleep disturbance, and fatigue; and swelling, inflammation, exudate, and fatigue. Conclusion Two symptom clusters were identified in this sample of patients with venous leg ulcers. Further research is needed to verify these symptom clusters and to evaluate their effect on patient outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research was a step forward in developing a data integration framework for Electronic Health Records. The outcome of the research is a conceptual and logical Data Warehousing model for integrating Cardiac Surgery electronic data records. This thesis investigated the main obstacles for the healthcare data integration and proposes a data warehousing model suitable for integrating fragmented data in a Cardiac Surgery Unit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent advances in the area of ‘Transformational Government’ position the citizen at the centre of focus. This paradigm shift from a department-centric to a citizen-centric focus requires governments to re-think their approach to service delivery, thereby decreasing costs and increasing citizen satisfaction. The introduction of franchises as a virtual business layer between the departments and their citizens is intended to provide a solution. Franchises are structured to address the needs of citizens independent of internal departmental structures. For delivering services online, governments pursue the development of a One-Stop Portal, which structures information and services through those franchises. Thus, each franchise can be mapped to a specific service bundle, which groups together services that are deemed to be of relevance to a specific citizen need. This study focuses on the development and evaluation of these service bundles. In particular, two research questions guide the line of investigation of this study: Research Question 1): What methods can be used by governments to identify service bundles as part of governmental One-Stop Portals? Research Question 2): How can the quality of service bundles in governmental One-Stop Portals be evaluated? The first research question asks about the identification of suitable service bundle identification methods. A literature review was conducted, to, initially, conceptualise the service bundling task, in general. As a consequence, a 4-layer model of service bundling and a morphological box were created, detailing characteristics that are of relevance when identifying service bundles. Furthermore, a literature review of Decision-Support Systems was conducted to identify approaches of relevance in different bundling scenarios. These initial findings were complemented by targeted studies of multiple leading governments in the e-government domain, as well as with a local expert in the field. Here, the aim was to identify the current status of online service delivery and service bundling in practice. These findings led to the conceptualising of two service bundle identification methods, applicable in the context of Queensland Government: On the one hand, a provider-driven approach, based on service description languages, attributes, and relationships between services was conceptualised. As well, a citizen-driven approach, based on analysing the outcomes from content identification and grouping workshops with citizens, was also conceptualised. Both methods were then applied and evaluated in practice. The conceptualisation of the provider-driven method for service bundling required the initial specification of relevant attributes that could be used to identify similarities between services called relationships; these relationships then formed the basis for the identification of service bundles. This study conceptualised and defined seven relationships, namely ‘Co-location’, ‘Resource’, ‘Co-occurrence’, ‘Event’, ‘Consumer’, ‘Provider’, and ‘Type’. The relationships, and the bundling method itself, were applied and refined as part of six Action Research cycles in collaboration with the Queensland Government. The findings show that attributes and relationships can be used effectively as a means for bundle identification, if distinct decision rules are in place to prescribe how services are to be identified. For the conceptualisation of the citizen-driven method, insights from the case studies led to the decision to involve citizens, through card sorting activities. Based on an initial list of services, relevant for a certain franchise, participating citizens grouped services according to their liking. The card sorting activity, as well as the required analysis and aggregation of the individual card sorting results, was analysed in depth as part of this study. A framework was developed that can be used as a decision-support tool to assist with the decision of what card sorting analysis method should be utilised in a given scenario. The characteristic features associated with card sorting in a government context led to the decision to utilise statistical analysis approaches, such as cluster analysis and factor analysis, to aggregate card sorting results. The second research question asks how the quality of service bundles can be assessed. An extensive literature review was conducted focussing on bundle, portal, and e-service quality. It was found that different studies use different constructs, terminology, and units of analysis, which makes comparing these models a difficult task. As a direct result, a framework was conceptualised, that can be used to position past and future studies in this research domain. Complementing the literature review, interviews conducted as part of the case studies with leaders in e-government, indicated that, typically, satisfaction is evaluated for the overall portal once the portal is online, but quality tests are not conducted during the development phase. Consequently, a research model which appropriately defines perceived service bundle quality would need to be developed from scratch. Based on existing theory, such as Theory of Reasoned Action, Expectation Confirmation Theory, and Theory of Affordances, perceived service bundle quality was defined as an inferential belief. Perceived service bundle quality was positioned within the nomological net of services. Based on the literature analysis on quality, and on the subsequent work of a focus group, the hypothesised antecedents (descriptive beliefs) of the construct and the associated question items were defined and the research model conceptualised. The model was then tested, refined, and finally validated during six Action Research cycles. Results show no significant difference in higher quality or higher satisfaction among users for either the provider-driven method or for the citizen-driven method. The decision on which method to choose, it was found, should be based on contextual factors, such as objectives, resources, and the need for visibility. The constructs of the bundle quality model were examined. While the quality of bundles identified through the citizen-centric approach could be explained through the constructs ‘Navigation’, ‘Ease of Understanding’, and ‘Organisation’, bundles identified through the provider-driven approach could be explained solely through the constructs ‘Navigation’ and ‘Ease of Understanding’. An active labelling style for bundles, as part of the provider-driven Information Architecture, had a larger impact on ‘Quality’ than the topical labelling style used in the citizen-centric Information Architecture. However, ‘Organisation’, reflecting the internal, logical structure of the Information Architecture, was a significant factor impacting on ‘Quality’ only in the citizen-driven Information Architecture. Hence, it was concluded that active labelling can compensate for a lack of logical structure. Further studies are needed to further test this conjecture. Such studies may involve building alternative models and conducting additional empirical research (e.g. use of an active labelling style for the citizen-driven Information Architecture). This thesis contributes to the body of knowledge in several ways. Firstly, it presents an empirically validated model of the factors explaining and predicting a citizen’s perception of service bundle quality. Secondly, it provides two alternative methods that can be used by governments to identify service bundles in structuring the content of a One-Stop Portal. Thirdly, this thesis provides a detailed narrative to suggest how the recent paradigm shift in the public domain, towards a citizen-centric focus, can be pursued by governments; the research methodology followed by this study can serve as an exemplar for governments seeking to achieve a citizen-centric approach to service delivery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: The purpose of the work presented in this paper was to determine whether patient positioning and delivery errors could be detected using electronic portal images of intensity modulated radiotherapy (IMRT). Patients and methods: We carried out a series of controlled experiments delivering an IMRT beam to a humanoid phantom using both the dynamic and multiple static field method of delivery. The beams were imaged, the images calibrated to remove the IMRT fluence variation and then compared with calibrated images of the reference beams without any delivery or position errors. The first set of experiments involved translating the position of the phantom both laterally and in a superior/inferior direction a distance of 1, 2, 5 and 10 mm. The phantom was also rotated 1 and 28. For the second set of measurements the phantom position was kept fixed and delivery errors were introduced to the beam. The delivery errors took the form of leaf position and segment intensity errors. Results: The method was able to detect shifts in the phantom position of 1 mm, leaf position errors of 2 mm, and dosimetry errors of 10% on a single segment of a 15 segment IMRT step and shoot delivery (significantly less than 1% of the total dose). Conclusions: The results of this work have shown that the method of imaging the IMRT beam and calibrating the images to remove the intensity modulations could be a useful tool in verifying both the patient position and the delivery of the beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The precise shape of the three-dimensional dose distributions created by intensity-modulated radiotherapy means that the verification of patient position and setup is crucial to the outcome of the treatment. In this paper, we investigate and compare the use of two different image calibration procedures that allow extraction of patient anatomy from measured electronic portal images of intensity-modulated treatment beams. Methods and Materials: Electronic portal images of the intensity-modulated treatment beam delivered using the dynamic multileaf collimator technique were acquired. The images were formed by measuring a series of frames or segments throughout the delivery of the beams. The frames were then summed to produce an integrated portal image of the delivered beam. Two different methods for calibrating the integrated image were investigated with the aim of removing the intensity modulations of the beam. The first involved a simple point-by-point division of the integrated image by a single calibration image of the intensity-modulated beam delivered to a homogeneous polymethyl methacrylate (PMMA) phantom. The second calibration method is known as the quadratic calibration method and required a series of calibration images of the intensity-modulated beam delivered to different thicknesses of homogeneous PMMA blocks. Measurements were made using two different detector systems: a Varian amorphous silicon flat-panel imager and a Theraview camera-based system. The methods were tested first using a contrast phantom before images were acquired of intensity-modulated radiotherapy treatment delivered to the prostate and pelvic nodes of cancer patients at the Royal Marsden Hospital. Results: The results indicate that the calibration methods can be used to remove the intensity modulations of the beam, making it possible to see the outlines of bony anatomy that could be used for patient position verification. This was shown for both posterior and lateral delivered fields. Conclusions: Very little difference between the two calibration methods was observed, so the simpler division method, requiring only the single extra calibration measurement and much simpler computation, was the favored method. This new method could provide a complementary tool to existing position verification methods, and it has the advantage that it is completely passive, requiring no further dose to the patient and using only the treatment fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural and electronic properties have been studied for Boron Nitride nanoribbons (BNNR) with both zigzag and armchair shaped edge (Z-BNNR and A-BNNR) by first-principle spin-polarized total energy calculations. We found that the energy band gap of Z-BNNR is indirect and decreases monotonically with the increasing ribbon width, whereas direct energy band gap oscillation was observed for A-BNNRs. Additionally, C-substitution at either single boron or nitrogen atom site in BNNRs could induce spontaneous magnetization. Our results could be potentially useful to design magnetic nano-devices based on BNNRs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, ab initio density functional theory (DFT) calculations are performed to study the structural and electronic properties of diazonium reagent functionalized (4, 4) single-walled carbon nanotube (SWCNT). We find the aryl group covalently bonds with SWCNT and prefers to be perpendicular to the side wall of nanotube. It has a rotational barrier of 0.35 eV around the formed aryl-tube bond axis and should be thermodynamically stable at room temperature. Additionally, new peaks appeared around the Fermi energy in the density of state (DOS) due to the weak band dispersion. Increasing of the coverage of the functional group will result in significant upshift of the Fermi level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The accurate identification of tissue electron densities is of great importance for Monte Carlo (MC) dose calculations. When converting patient CT data into a voxelised format suitable for MC simulations, however, it is common to simplify the assignment of electron densities so that the complex tissues existing in the human body are categorized into a few basic types. This study examines the effects that the assignment of tissue types and the calculation of densities can have on the results of MC simulations, for the particular case of a Siemen’s Sensation 4 CT scanner located in a radiotherapy centre where QA measurements are routinely made using 11 tissue types (plus air). Methods: DOSXYZnrc phantoms are generated from CT data, using the CTCREATE user code, with the relationship between Hounsfield units (HU) and density determined via linear interpolation between a series of specified points on the ‘CT-density ramp’ (see Figure 1(a)). Tissue types are assigned according to HU ranges. Each voxel in the DOSXYZnrc phantom therefore has an electron density (electrons/cm3) defined by the product of the mass density (from the HU conversion) and the intrinsic electron density (electrons /gram) (from the material assignment), in that voxel. In this study, we consider the problems of density conversion and material identification separately: the CT-density ramp is simplified by decreasing the number of points which define it from 12 down to 8, 3 and 2; and the material-type-assignment is varied by defining the materials which comprise our test phantom (a Supertech head) as two tissues and bone, two plastics and bone, water only and (as an extreme case) lead only. The effect of these parameters on radiological thickness maps derived from simulated portal images is investigated. Results & Discussion: Increasing the degree of simplification of the CT-density ramp results in an increasing effect on the resulting radiological thickness calculated for the Supertech head phantom. For instance, defining the CT-density ramp using 8 points, instead of 12, results in a maximum radiological thickness change of 0.2 cm, whereas defining the CT-density ramp using only 2 points results in a maximum radiological thickness change of 11.2 cm. Changing the definition of the materials comprising the phantom between water and plastic and tissue results in millimetre-scale changes to the resulting radiological thickness. When the entire phantom is defined as lead, this alteration changes the calculated radiological thickness by a maximum of 9.7 cm. Evidently, the simplification of the CT-density ramp has a greater effect on the resulting radiological thickness map than does the alteration of the assignment of tissue types. Conclusions: It is possible to alter the definitions of the tissue types comprising the phantom (or patient) without substantially altering the results of simulated portal images. However, these images are very sensitive to the accurate identification of the HU-density relationship. When converting data from a patient’s CT into a MC simulation phantom, therefore, all possible care should be taken to accurately reproduce the conversion between HU and mass density, for the specific CT scanner used. Acknowledgements: This work is funded by the NHMRC, through a project grant, and supported by the Queensland University of Technology (QUT) and the Royal Brisbane and Women's Hospital (RBWH), Brisbane, Australia. The authors are grateful to the staff of the RBWH, especially Darren Cassidy, for assistance in obtaining the phantom CT data used in this study. The authors also wish to thank Cathy Hargrave, of QUT, for assistance in formatting the CT data, using the Pinnacle TPS. Computational resources and services used in this work were provided by the HPC and Research Support Group, QUT, Brisbane, Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The use of amorphous-silicon electronic portal imaging devices (a-Si EPIDs) for dosimetry is complicated by the effects of scattered radiation. In photon radiotherapy, primary signal at the detector can be accompanied by photons scattered from linear accelerator components, detector materials, intervening air, treatment room surfaces (floor, walls, etc) and from the patient/phantom being irradiated. Consequently, EPID measurements which presume to take scatter into account are highly sensitive to the identification of these contributions. One example of this susceptibility is the process of calibrating an EPID for use as a gauge of (radiological) thickness, where specific allowance must be made for the effect of phantom-scatter on the intensity of radiation measured through different thicknesses of phantom. This is usually done via a theoretical calculation which assumes that phantom scatter is linearly related to thickness and field-size. We have, however, undertaken a more detailed study of the scattering effects of fields of different dimensions when applied to phantoms of various thicknesses in order to derive scattered-primary ratios (SPRs) directly from simulation results. This allows us to make a more-accurate calibration of the EPID, and to qualify the appositeness of the theoretical SPR calculations. Methods: This study uses a full MC model of the entire linac-phantom-detector system simulated using EGSnrc/BEAMnrc codes. The Elekta linac and EPID are modelled according to specifications from the manufacturer and the intervening phantoms are modelled as rectilinear blocks of water or plastic, with their densities set to a range of physically realistic and unrealistic values. Transmissions through these various phantoms are calculated using the dose detected in the model EPID and used in an evaluation of the field-size-dependence of SPR, in different media, applying a method suggested for experimental systems by Swindell and Evans [1]. These results are compared firstly with SPRs calculated using the theoretical, linear relationship between SPR and irradiated volume, and secondly with SPRs evaluated from our own experimental data. An alternate evaluation of the SPR in each simulated system is also made by modifying the BEAMnrc user code READPHSP, to identify and count those particles in a given plane of the system that have undergone a scattering event. In addition to these simulations, which are designed to closely replicate the experimental setup, we also used MC models to examine the effects of varying the setup in experimentally challenging ways (changing the size of the air gap between the phantom and the EPID, changing the longitudinal position of the EPID itself). Experimental measurements used in this study were made using an Elekta Precise linear accelerator, operating at 6MV, with an Elekta iView GT a-Si EPID. Results and Discussion: 1. Comparison with theory: With the Elekta iView EPID fixed at 160 cm from the photon source, the phantoms, when positioned isocentrically, are located 41 to 55 cm from the surface of the panel. At this geometry, a close but imperfect agreement (differing by up to 5%) can be identified between the results of the simulations and the theoretical calculations. However, this agreement can be totally disrupted by shifting the phantom out of the isocentric position. Evidently, the allowance made for source-phantom-detector geometry by the theoretical expression for SPR is inadequate to describe the effect that phantom proximity can have on measurements made using an (infamously low-energy sensitive) a-Si EPID. 2. Comparison with experiment: For various square field sizes and across the range of phantom thicknesses, there is good agreement between simulation data and experimental measurements of the transmissions and the derived values of the primary intensities. However, the values of SPR obtained through these simulations and measurements seem to be much more sensitive to slight differences between the simulated and real systems, leading to difficulties in producing a simulated system which adequately replicates the experimental data. (For instance, small changes to simulated phantom density make large differences to resulting SPR.) 3. Comparison with direct calculation: By developing a method for directly counting the number scattered particles reaching the detector after passing through the various isocentric phantom thicknesses, we show that the experimental method discussed above is providing a good measure of the actual degree of scattering produced by the phantom. This calculation also permits the analysis of the scattering sources/sinks within the linac and EPID, as well as the phantom and intervening air. Conclusions: This work challenges the assumption that scatter to and within an EPID can be accounted for using a simple, linear model. Simulations discussed here are intended to contribute to a fuller understanding of the contribution of scattered radiation to the EPID images that are used in dosimetry calculations. Acknowledgements: This work is funded by the NHMRC, through a project grant, and supported by the Queensland University of Technology (QUT) and the Royal Brisbane and Women's Hospital, Brisbane, Australia. The authors are also grateful to Elekta for the provision of manufacturing specifications which permitted the detailed simulation of their linear accelerators and amorphous-silicon electronic portal imaging devices. Computational resources and services used in this work were provided by the HPC and Research Support Group, QUT, Brisbane, Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis investigated the viability of using Frequency Response Functions in combination with Artificial Neural Network technique in damage assessment of building structures. The proposed approach can help overcome some of limitations associated with previously developed vibration based methods and assist in delivering more accurate and robust damage identification results. Excellent results are obtained for damage identification of the case studies proving that the proposed approach has been developed successfully.