975 resultados para diagnostic methods


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Rapid diagnostic tests for malaria (RDTs) allow accurate diagnosis and prompt treatment. Validation of their usefulness in travellers with fever was needed. The safety of a strategy to diagnose falciparum malaria based on RDT followed by immediate or delayed microscopy reading at first attendance was evaluated in one referral hospital in Switzerland. METHODS: A retrospective study was conducted in the outpatient clinic and emergency ward of University Hospital, covering a period of eight years (1999-2007). The study was conducted in the outpatient clinic and emergency ward of University Hospital. All adults suspected of malaria with a diagnostic test performed were included. RDT and microscopy as immediate tests were performed during working hours, and RDT as immediate test and delayed microscopy reading out of laboratory working hours. The main outcome measure was occurrence of specific complications in RDT negative and RDT positive adults. RESULTS: 2,139 patients were recruited. 1987 had both initial RDT and blood smear (BS) result negative. Among those, 2/1987 (0.1%) developed uncomplicated malaria with both RDT and BS positive on day 1 and day 6 respectively. Among the 152 patients initially malaria positive, 137 had both RDT and BS positive, four only BS positive and five only RDT positive (PCR confirmed) (six had only one test performed). None of the four initially RDT negative/BS positive and none of the five initially BS negative/RDT positive developed severe malaria while 6/137 of both RDT and BS positive did so. The use of RDT allowed a reduction of a median of 2.1 hours to get a first malaria test result. CONCLUSIONS: A malaria diagnostic strategy based on RDTs and a delayed BS is safe in non-immune populations, and shortens the time to first malaria test result.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Laboratory detection of vancomycin-intermediate Staphylococcus aureus (VISA) and their heterogeneous VISA (hVISA) precursors is difficult. Thus, it is possible that vancomycin failures against supposedly vancomycin-susceptible S. aureus are due to undiagnosed VISA or hVISA. We tested this hypothesis in experimental endocarditis.¦METHODS: Rats with aortic valve infection due to the vancomycin-susceptible (MIC 2 mg/L), methicillin-resistant S. aureus M1V2 were treated for 2 days with doses of vancomycin that mimicked the pharmacokinetics seen in humans following intravenous administration of 1 g of the drug every 12 h. Half of the treated animals were killed 8 h after treatment arrest and half 3 days thereafter. Population analyses were done directly on vegetation homogenates or after one subculture in drug-free medium to mimic standard diagnostic procedures.¦RESULTS: Vancomycin cured 14 of 26 animals (54%; P<0.05 versus controls) after 2 days of treatment. When vegetation homogenates were plated directly on vancomycin-containing plates, 6 of 13 rats killed 8 h after treatment arrest had positive cultures, 1 of which harboured hVISA. Likewise, 6 of 13 rats killed 3 days thereafter had positive valve cultures, 5 of which harboured hVISA. However, one subculture of vegetations in drug-free broth was enough to revert all the hVISA phenotypes to the susceptible pattern of the parent. Thus, vancomycin selected for hVISA during therapy of experimental endocarditis due to vancomycin-susceptible S. aureus. These hVISA were associated with vancomycin failure. The hVISA phenotype persisted in vivo, even after vancomycin arrest, but was missed in vitro after a single passage of the vegetation homogenate on drug-free medium.¦CONCLUSIONS: hVISA might escape detection in clinical samples if they are subcultured before susceptibility tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To systematically review and meta-analyze published data about the diagnostic accuracy of fluorine-18-fluorodeoxyglucose ((18)F-FDG) positron emission tomography (PET) and PET/computed tomography (CT) in the differential diagnosis between malignant and benign pleural lesions. METHODS AND MATERIALS: A comprehensive literature search of studies published through June 2013 regarding the diagnostic performance of (18)F-FDG-PET and PET/CT in the differential diagnosis of pleural lesions was carried out. All retrieved studies were reviewed and qualitatively analyzed. Pooled sensitivity, specificity, positive and negative likelihood ratio (LR+ and LR-) and diagnostic odds ratio (DOR) of (18)F-FDG-PET or PET/CT in the differential diagnosis of pleural lesions on a per-patient-based analysis were calculated. The area under the summary receiver operating characteristic curve (AUC) was calculated to measure the accuracy of these methods. Subanalyses considering device used (PET or PET/CT) were performed. RESULTS: Sixteen studies including 745 patients were included in the systematic review. The meta-analysis of 11 selected studies provided the following results: sensitivity 95% (95% confidence interval [95%CI]: 92-97%), specificity 82% (95%CI: 76-88%), LR+ 5.3 (95%CI: 2.4-11.8), LR- 0.09 (95%CI: 0.05-0.14), DOR 74 (95%CI: 34-161). The AUC was 0.95. No significant improvement of the diagnostic accuracy considering PET/CT studies only was found. CONCLUSIONS: (18)F-FDG-PET and PET/CT demonstrated to be accurate diagnostic imaging methods in the differential diagnosis between malignant and benign pleural lesions; nevertheless, possible sources of false-negative and false-positive results should be kept in mind.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine and compare the diagnostic performance of magnetic resonance imaging (MRI) and computed tomography (CT) for the diagnosis of tumor extent in advanced retinoblastoma, using histopathologic analysis as the reference standard. DESIGN: Systematic review and meta-analysis. PARTICIPANTS: Patients with advanced retinoblastoma who underwent MRI, CT, or both for the detection of tumor extent from published diagnostic accuracy studies. METHODS: Medline and Embase were searched for literature published through April 2013 assessing the diagnostic performance of MRI, CT, or both in detecting intraorbital and extraorbital tumor extension of retinoblastoma. Diagnostic accuracy data were extracted from included studies. Summary estimates were based on a random effects model. Intrastudy and interstudy heterogeneity were analyzed. MAIN OUTCOME MEASURES: Sensitivity and specificity of MRI and CT in detecting tumor extent. RESULTS: Data of the following tumor-extent parameters were extracted: anterior eye segment involvement and ciliary body, optic nerve, choroidal, and (extra)scleral invasion. Articles on MRI reported results of 591 eyes from 14 studies, and articles on CT yielded 257 eyes from 4 studies. The summary estimates with their 95% confidence intervals (CIs) of the diagnostic accuracy of conventional MRI at detecting postlaminar optic nerve, choroidal, and scleral invasion showed sensitivities of 59% (95% CI, 37%-78%), 74% (95% CI, 52%-88%), and 88% (95% CI, 20%-100%), respectively, and specificities of 94% (95% CI, 84%-98%), 72% (95% CI, 31%-94%), and 99% (95% CI, 86%-100%), respectively. Magnetic resonance imaging with a high (versus a low) image quality showed higher diagnostic accuracies for detection of prelaminar optic nerve and choroidal invasion, but these differences were not statistically significant. Studies reporting the diagnostic accuracy of CT did not provide enough data to perform any meta-analyses. CONCLUSIONS: Magnetic resonance imaging is an important diagnostic tool for the detection of local tumor extent in advanced retinoblastoma, although its diagnostic accuracy shows room for improvement, especially with regard to sensitivity. With only a few-mostly old-studies, there is very little evidence on the diagnostic accuracy of CT, and generally these studies show low diagnostic accuracy. Future studies assessing the role of MRI in clinical decision making in terms of prognostic value for advanced retinoblastoma are needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The treatment of the recently ruptured Achilles tendon can be conservative or surgical. The conservative treatment may be carried out using either a static cast immobilisation or using a dynamic brace and an early functional rehabilitation. The surgical technique can be either open or mini-invasive. Neglected and ancient ruptures may need to be treated surgically by a tendinoplasty. There is an ongoing discussion about how to manage the recently ruptured Achilles tendon, especially since recent descriptions of conservative-functional treatment procedures and mini-invasive surgical techniques. We present the choice of the different treatment options and the clinical reasoning to identify the best adapted treatment for the individual patient. The ideal treatment option depends on the functional demand and the medical condition of the patient.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to conduct a systematic review and perform a meta-analysis on the diagnostic performances of (18)F-fluorodeoxyglucose positron emission tomography (FDG PET) for giant cell arteritis (GCA), with or without polymyalgia rheumatica (PMR). METHODS: MEDLINE, Embase and the Cochrane Library were searched for articles in English that evaluated FDG PET in GCA or PMR. All complete studies were reviewed and qualitatively analysed. Studies that fulfilled the three following criteria were included in a meta-analysis: (1) FDG PET used as a diagnostic tool for GCA and PMR; (2) American College of Rheumatology and Healey criteria used as the reference standard for the diagnosis of GCA and PMR, respectively; and (3) the use of a control group. RESULTS: We found 14 complete articles. A smooth linear or long segmental pattern of FDG uptake in the aorta and its main branches seems to be a characteristic pattern of GCA. Vessel uptake that was superior to liver uptake was considered an efficient marker for vasculitis. The meta-analysis of six selected studies (101 vasculitis and 182 controls) provided the following results: sensitivity 0.80 [95% confidence interval (CI) 0.63-0.91], specificity 0.89 (95% CI 0.78-0.94), positive predictive value 0.85 (95% CI 0.62-0.95), negative predictive value 0.88 (95% CI 0.72-0.95), positive likelihood ratio 6.73 (95% CI 3.55-12.77), negative likelihood ratio 0.25 (95% CI 0.13-0.46) and accuracy 0.84 (95% CI 0.76-0.90). CONCLUSION: We found overall valuable diagnostic performances for FDG PET against reference criteria. Standardized FDG uptake criteria are needed to optimize these diagnostic performances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atherosclerotic renal artery disease represents a cause of which little is known but not a cause to be neglected for hypertension and renal insufficiency. Even though its occurrence remains badly defined, atherosclerotic renal artery disease is constantly on the rise due to the aging population, the never prevailing hypertension and diabetes mellitus. This review aims to give a clinical profile of patients presenting with atherosclerotic renal artery disease and to discuss, in the light of study results, which diagnostic evaluation should be used considering the sequence and the benefit and risk of each in order to initiate a personalized treatment. Patients affected by atherosclerotic renal artery disease are likely to have more complications and more extensive target-organ damage than patients without renal artery stenosis. The evolution of the atherosclerotic renal artery disease is in general slow and progressive. Nevertheless, certain clinical cases manifest themselves with the onset of acute renal failure bought upon by the administration of blockers of the rennin-angiotensin-aldosterone system, or by some other causes responsible for a sudden drop in renal plasma flow (e.g., thrombosis of the renal artery). The relationship between atherosclerotic renal artery disease and atherosclerosis is complex, and mediators implicated in the pathophysiology of renovascular disease may also contribute to the progression of cardiovascular damage. An early assumption of the atherosclerotic renal artery stenosis is warranted to determine the adapted treatment (i.e., medical treatment, revascularisation...) just as the assumption and the correction of the more general cardiovascular risk factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: We have recently shown that the median diagnostic delay to establish Crohn's disease (CD) diagnosis (i.e. the period from first symptom onset to diagnosis) in the Swiss IBD Cohort (SIBDC) was 9 months. Seventy five percent of all CD patients were diagnosed within 24 months. The clinical impact of a long diagnostic delay on the natural history of CD is unknown. Aim: To compare the frequency and type of CD-related complications in the patient groups with long diagnostic delay (>24 months) vs. the ones diagnosed within 24 months. Methods: Retrospective analysis of data from the SIBDCS, comprising a large sample of CD patients followed in hospitals and private practices across Switzerland. The proportions of the following outcomes were compared between groups of patients diagnosed 1, 2-5, 6-10, 11-15, and ≥ 16 years ago and stratified according to the length of diagnostic delay: bowel stenoses, internal fistulas, perianal fistulas, CD-related surgical interventions, and extraintestinal manifestations. Results: Two hundred CD patients (121 female, mean age 44.9 ± 15.0 years, 38% smokers, 71% ever treated with immunomodulators and 35% with anti-TNF) with long diagnostic delay were compared to 697 CD patients (358 female, mean age 39.1 ± 14.9 years, 33% smokers, 74% ever treated with immunomodulators and 33% with anti-TNF) diagnosed within 24 months. No differences in the outcomes were observed between the two patient groups within year one after CD diagnosis. Among those diagnosed 2-5 years ago, CD patients with long diagnostic delay (n = 45) presented more frequently with internal fistulas (11.1% vs. 3.1%, p = 0.03) and bowel stenoses (28.9% vs. 15.7%, p = 0.05), and they more frequently underwent CD-related operations (15.6% vs. 5.0%, p = 0.02) compared to the patients diagnosed within 24 months (n = 159). Among those diagnosed 6-10 years ago, CD patients with long diagnostic delay (n = 48) presented more frequently with extraintestinal manifestations (60.4% vs. 34.6%, p = 0.001) than those diagnosed within 24 months (n = 182). For the patients diagnosed 11-15 years ago, no differences in outcomes were found between the long diagnostic delay group (n = 106) and the one diagnosed within 24 months (n = 32). Among those diagnosed ≥ 16 years ago, the group with long diagnostic delay (n = 71) more frequently underwent CD-related operations (63.4% vs. 46.5%, p = 0.01) compared to the group diagnosed with CD within 24 months (n = 241). Conclusions: A long diagnostic delay in CD patients is associated with a more complicated disease course and higher number of CD-related operations in the years following the diagnosis. Our results indicate that efforts should be undertaken to shorten the diagnostic delay in CD patients in order to reduce the risk for progression towards a complicated disease phenotype.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our aim was to evaluate the role of forced diuresis in improving the diagnostic accuracy of abdominopelvic (18)F-FDG PET. METHODS: Thirty-two patients were enrolled. Besides the presence of known intravesical tumors or undefined renal lesions on the initial PET scan, the inclusion criterion was the appearance of indeterminate or equivocal (18)F-FDG foci that extended along the course of the urinary tract and could not confidently be separated from urinary activity. For each patient, a second abdominopelvic PET study was performed after intravenous injection of 0.5 mg of furosemide per kilogram of body weight (maximum, 40 mg) coupled with parenteral infusion of physiologic saline. RESULTS: Forced diuresis coupled with parenteral hydration eliminated any significant (18)F-FDG activity from the lower urinary tract in 31 (97%) of 32 patients after the bladder had been voided 3 successive times. Twelve intravesical lesions were visualized with outstanding clarity, whereas radiologic suspicion of locally recurrent bladder tumors was ruled out in 3 patients. Among 14 indeterminate or equivocal extravesical foci, 7 were deemed of no clinical value because they disappeared after furosemide challenge, whereas 7 persisting foci were proven to be true-positive PET findings. The performance of (18)F-FDG PET in characterizing 3 renal-space-occupying lesions could not be improved by our protocol. CONCLUSION: Furosemide challenge has the potential to noninvasively resolve the inherent (18)F-FDG contrast handicap in the lower urinary tract.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Decision to revascularize a patient with stable coronary artery disease should be based on the detection of myocardial ischemia. If this decision can be straightforward with significant stenosis or in non-significant stenosis, the decision with intermediate stenosis is far more difficult and require invasive measures of functional impact of coronary stenosis on maximal blood (flow fractional flow reserve=FFR). A recent computer based method has been developed and is able to measure FFR with data acquired during a standard coronary CT-scan (FFRcT). Two recent clinical studies (DeFACTO and DISCOVER-FLOW) show that diagnostic performance of FFRcT was associated with improved diagnostic accuracy versus standard coronary CT-scan for the detection of myocardial ischemia although FFRcT need further development.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The quality of colon cleansing is a major determinant of quality of colonoscopy. To our knowledge, the impact of bowel preparation on the quality of colonoscopy has not been assessed prospectively in a large multicenter study. Therefore, this study assessed the factors that determine colon-cleansing quality and the impact of cleansing quality on the technical performance and diagnostic yield of colonoscopy. METHODS: Twenty-one centers from 11 countries participated in this prospective observational study. Colon-cleansing quality was assessed on a 5-point scale and was categorized on 3 levels. The clinical indication for colonoscopy, diagnoses, and technical parameters related to colonoscopy were recorded. RESULTS: A total of 5832 patients were included in the study (48.7% men, mean age 57.6 [15.9] years). Cleansing quality was lower in elderly patients and in patients in the hospital. Procedures in poorly prepared patients were longer, more difficult, and more often incomplete. The detection of polyps of any size depended on cleansing quality: odds ratio (OR) 1.73: 95% confidence interval (CI)[1.28, 2.36] for intermediate-quality compared with low-quality preparation; and OR 1.46: 95% CI[1.11, 1.93] for high-quality compared with low-quality preparation. For polyps >10 mm in size, corresponding ORs were 1.0 for low-quality cleansing, OR 1.83: 95% CI[1.11, 3.05] for intermediate-quality cleansing, and OR 1.72: 95% CI[1.11, 2.67] for high-quality cleansing. Cancers were not detected less frequently in the case of poor preparation. CONCLUSIONS: Cleansing quality critically determines quality, difficulty, speed, and completeness of colonoscopy, and is lower in hospitalized patients and patients with higher levels of comorbid conditions. The proportion of patients who undergo polypectomy increases with higher cleansing quality, whereas colon cancer detection does not seem to critically depend on the quality of bowel preparation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Acute myocarditis was until recently one of the most difficult diagnoses in cardiology. The spectrum of signs and symptoms is very wide, the usual non-invasive tests lack specificity and the myocardial biopsy is only performed in a minority of cases to confirm the diagnosis. Due to its unique ability to directly image myocardial necrosis, fibrosis and oedema, cardiac magnetic resonance (CMR) is now considered the primary tool for noninvasive assessment of patients with suspected myocarditis. CMR is also useful for monitoring disease activity under treatment. Myocarditis has been associated with the development of dilated cardiomyopathy; CMR could play a role in the follow-up of such cases to detect the progression toward a dilatative phenotype. Precise mapping of myocardial lesions with cardiac MRI is invaluable to guide myocardial biopsy and increase its diagnostic yield by improving sensitivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The original and modified Wells score are widely used prediction rules for pre-test probability assessment of deep vein thrombosis (DVT). The objective of this study was to compare the predictive performance of both Wells scores in unselected patients with clinical suspicion of DVT.Methods: Consecutive inpatients and outpatients with a clinical suspicion of DVT were prospectively enrolled. Pre-test DVT probability (low/intermediate/high) was determined using both scores. Patients with a non-high probability based on the original Wells score underwent D-dimers measurement. Patients with D-dimers <500 mu g/L did not undergo further testing, and treatment was withheld. All others underwent complete lower limb compression ultrasound, and those diagnosed with DVT were anticoagulated. The primary study outcome was objectively confirmed symptomatic venous thromboembolism within 3 months of enrollment.Results: 298 patients with suspected DVT were included. Of these, 82 (27.5%) had DVT, and 46 of them were proximal. Compared to the modified score, the original Wells score classified a higher proportion of patients as low-risk (53 vs 48%; p<0.01) and a lower proportion as high-risk (17 vs 15%; p=0.02); the prevalence of proximal DVT in each category was similar with both scores (7-8% low, 16-19% intermediate, 36-37% high). The area under the receiver operating characteristic curve regarding proximal DVT detection was similar for both scores, but they both performed poorly in predicting isolated distal DVT and DVT in inpatients.Conclusion: The study demonstrates that both Wells scores perform equally well in proximal DVT pre-test probability prediction. Neither score appears to be particularly useful in hospitalized patients and those with isolated distal DVT. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this paper is to compare the performance of twopredictive radiological models, logistic regression (LR) and neural network (NN), with five different resampling methods. One hundred and sixty-seven patients with proven calvarial lesions as the only known disease were enrolled. Clinical and CT data were used for LR and NN models. Both models were developed with cross validation, leave-one-out and three different bootstrap algorithms. The final results of each model were compared with error rate and the area under receiver operating characteristic curves (Az). The neural network obtained statistically higher Az than LR with cross validation. The remaining resampling validation methods did not reveal statistically significant differences between LR and NN rules. The neural network classifier performs better than the one based on logistic regression. This advantage is well detected by three-fold cross-validation, but remains unnoticed when leave-one-out or bootstrap algorithms are used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effective dose delivered to the patient was determined, by modeling, for 257 types of examinations covering the different modalities of diagnostic and interventional radiology. The basic operational dosimetric quantities considered were obtained from the parameters of the examinations on the basis of dosimetric models. These models required a precise characterization of each examination. The operational dosimetric quantities were converted into doses to organs and effective doses using appropriate conversion factors. The determination of the collective effective dose to the Swiss population requires a number of corrections to account for the variability of several parameters: sensitivity of the detection system, age, gender, and build of the patient. The use of various dosimetric models is illustrated in this paper for a limited number of examination types covering the different radiological modalities, for which the established typical effective doses are given. With regard to individual doses, the study indicated that the average effective doses per type of examination can be classified into three levels: (a) the weakly irradiating examinations (less than 0.1 mSv), which represent 78% of the examinations and 4% of the collective dose, (b) the moderately irradiating examinations (between 0.1 mSv and 10 mSv), which represent 21% of the examinations and 72% of the collective dose, (c) the strongly irradiating examinations (more than 10 mSv), which represent 1% of the examinations and 24% of the collective dose.