827 resultados para deep bed filtration
Resumo:
This study investigated the discontinuous frying of breaded meat products in palm olein in a 28 L-electric fryer maintained at 182 ºC for 8 hours a day. Three 400-500 g batches of meat products were fried for 4.5 minutes daily. For comparison purpose, thermoxidation tests were performed using inert material with added moisture and without the addition of f ood (heating only). The total polar compound content did not reach the 25% limit, and nor did the formation of polymerized products exceed 5%, which indicates the good frying performance of palm olein for frying. Other analytical parameters and rapid tests were also evaluated. The sensory attributes, such as odor, colour, and foam formation determined when the frying oils should be discarded. The addition of water to the inert material contributed to the final value of 1.00 ± 0.01% (in palmitic acid), while the oil subjected only to heating reached respectively 0.26 ± 0.02%, and the oils used to fry breaded meat and breaded chicken reached 0.38 ± 0.00% and 2.35 ± 0.01%, respectively. This suggests a protective effect of the water during frying since the oil subjected only to heating was more prone to degradation.
Resumo:
Fried foods are widely consumed in Brazil and their quality depends on the oil or fat they are fried. Qualitative (physical chemistry indices) and quantitative measurements (fry-life oil or fat until disposal, oil turnover, type of oil or fat and amount and type of fried foods) and associations were performed. We applied a structured form and collected 60 mL of frying oil or fat in each of the 70 fried food stands of 15 street-fairs in Goiânia, Brazil. All samples were suitable in the quantity of free fat acids (<0.9% oleic acid), one was inadequate to peroxide value (>10 mEq/kg) and 1/3 was unsuitable to polar compounds (<25%). The majority (62%) use temperature up to the allowed (180 ºC). Approximately 250 units of products are fried in at least one day in 42% of the fried food stands. Soybean oil is used in the majority (94%) of fried food stands and the fry-life is of 6 hours (60%) or a day of work/sale. The nonconformity of the content of total polar compounds in fried foods had significant association with frying time and the conformity of acidity had significant relationship with frying time by a chi-square test. All other associations were not significant. A fry-life of oil or fat up to 6 hours can avoid the excess of polar compounds in the frying medium and protect the quality of fred foods.
Resumo:
This thesis addresses the coolability of porous debris beds in the context of severe accident management of nuclear power reactors. In a hypothetical severe accident at a Nordic-type boiling water reactor, the lower drywell of the containment is flooded, for the purpose of cooling the core melt discharged from the reactor pressure vessel in a water pool. The melt is fragmented and solidified in the pool, ultimately forming a porous debris bed that generates decay heat. The properties of the bed determine the limiting value for the heat flux that can be removed from the debris to the surrounding water without the risk of re-melting. The coolability of porous debris beds has been investigated experimentally by measuring the dryout power in electrically heated test beds that have different geometries. The geometries represent the debris bed shapes that may form in an accident scenario. The focus is especially on heap-like, realistic geometries which facilitate the multi-dimensional infiltration (flooding) of coolant into the bed. Spherical and irregular particles have been used to simulate the debris. The experiments have been modeled using 2D and 3D simulation codes applicable to fluid flow and heat transfer in porous media. Based on the experimental and simulation results, an interpretation of the dryout behavior in complex debris bed geometries is presented, and the validity of the codes and models for dryout predictions is evaluated. According to the experimental and simulation results, the coolability of the debris bed depends on both the flooding mode and the height of the bed. In the experiments, it was found that multi-dimensional flooding increases the dryout heat flux and coolability in a heap-shaped debris bed by 47–58% compared to the dryout heat flux of a classical, top-flooded bed of the same height. However, heap-like beds are higher than flat, top-flooded beds, which results in the formation of larger steam flux at the top of the bed. This counteracts the effect of the multi-dimensional flooding. Based on the measured dryout heat fluxes, the maximum height of a heap-like bed can only be about 1.5 times the height of a top-flooded, cylindrical bed in order to preserve the direct benefit from the multi-dimensional flooding. In addition, studies were conducted to evaluate the hydrodynamically representative effective particle diameter, which is applied in simulation models to describe debris beds that consist of irregular particles with considerable size variation. The results suggest that the effective diameter is small, closest to the mean diameter based on the number or length of particles.
Resumo:
The evaluation of filtration methods on the yield and oleochemicals characteristics on the crude fish oil from the soapstock of marine fish for purposes of nutrition has been conducted in this work. The analytical properties of the crude and the neutralized oil with three excesses of sodium hydroxide (NaOH, 20%, 40% and 60%) were carried out on two different ways with organza and the “glass wool”. The neutralization of the oil brought about a notable improvement in the analytical properties of the oil. Thus, it leads to a high quality fish oil in terms of taste, colour, odours, shelf life and market value. Based on the improved characteristics of the oil, it could be suitable for applications in pharmaceutical and food industries.
Resumo:
The removal of organics from copper electrolyte solutions after solvent extraction by dual media filtration is one of the most efficient ways to ensure the clean electrolyte flow into the electrowinning. The clean electrolyte will ensure the good quality cathode plate production. Dual media filtration uses two layers of filter media for filtration as anthracite and garnet respectively. The anthracite layer will help the coalescing of the entrained organic droplets which will then float to the top of the filter, and back to the solvent extraction process. The garnet layer will catch any solids left in the electrolyte traveling through the filter media. This thesis will concentrate on characterization of five different anthracites in order to find some differences using specific surface area analysis, particle size analysis, and morphology analysis. These results are compared to the pressure loss values obtained from lab column tests and bed expansion behavior. The goal of the thesis was to find out if there were any differences in the anthracite which would make the one perform better than the other. There were no big differences found on any aspect of the particle characterization, but some found differences should be further studied in order to confirm the meaning of the porosity, surface area, intensity mean and intensity SD (Standard Deviation) on anthracites and their use in dual media filtration. The thesis work analyzed anthracite samples the way that is not found on any public literature sources, and further studies on the issue would bring more knowledge to the electrolyte process.
Resumo:
The aim of this thesis is to find and analyze different methods which reduce fluid bed boilers’ auxiliary power consumption. The objective is to examine the effects and feasibility of these methods. The literature part explains how fluid bed boilers work and what are the main sources of auxiliary power consumption. Designs and operation of these equipment are presented. The literature part also discusses the basics of auxiliary power consumption reduction and introduces four low pressure drop constructions. The experimental part inspects six different methods. Effects of these methods on the auxiliary power consumption are calculated and their impacts on the operation of the boiler are modeled. Calculations show that reasonable changes can reduce fluid bed boiler’s auxiliary power consumption by 2,1-10,2 %. Biggest reductions come from lower air coefficients, smaller bed a-level pressures and lower primary/secondary air –ratios. Models showed no problems with the smaller bed a-level pressures. With the lower air coefficients and smaller primary/secondary air –ratios the models showed a significant increase in the carbon monoxide levels.
Resumo:
Increasing amount of renewable energy source based electricity production has set high load control requirements for power grid balance markets. The essential grid balance between electricity consumption and generation is currently hard to achieve economically with new-generation solutions. Therefore conventional combustion power generation will be examined in this thesis as a solution to the foregoing issue. Circulating fluidized bed (CFB) technology is known to have sufficient scale to acts as a large grid balancing unit. Although the load change rate of the CFB unit is known to be moderately high, supplementary repowering solution will be evaluated in this thesis for load change maximization. The repowering heat duty is delivered to the CFB feed water preheating section by smaller gas turbine (GT) unit. Consequently, steam extraction preheating may be decreased and large amount of the gas turbine exhaust heat may be utilized in the CFB process to reach maximum plant electrical efficiency. Earlier study of the repowering has focused on the efficiency improvements and retrofitting to maximize plant electrical output. This study however presents the CFB load change improvement possibilities achieved with supplementary GT heat. The repowering study is prefaced with literature and theory review for both of the processes to maximize accuracy of the research. Both dynamic and steady-state simulations accomplished with APROS simulation tool will be used to evaluate repowering effects to the CFB unit operation. Eventually, a conceptual level analysis is completed to compare repowered plant performance to the state-of-the-art CFB performance. Based on the performed simulations, considerably good improvements to the CFB process parameters are achieved with repowering. Consequently, the results show possibilities to higher ramp rate values achieved with repowered CFB technology. This enables better plant suitability to the grid balance markets.
Resumo:
The objectives of this master’s thesis were to understand the importance of bubbling fluidized bed (BFB) conditions and to find out how digital image processing and acoustic emission technology can help in monitoring the bed quality. An acoustic emission (AE) measurement system and a bottom ash camera system were evaluated in acquiring information about the bed conditions. The theory part of the study describes the fundamentals of BFB boiler and evaluates the characteristics of bubbling bed. Causes and effects of bed material coarsening are explained. The ways and methods to monitor the behaviour of BFB are determined. The study introduces the operating principles of AE technology and digital image processing. The empirical part of the study describes an experimental arrangement and results of a case study at an industrial BFB boiler. Sand consumption of the boiler was reduced by optimization of bottom ash handling and sand feeding. Furthermore, data from the AE measurement system and the bottom ash camera system was collected. The feasibility of these two systems was evaluated. The particle size of bottom ash and the changes in particle size distribution were monitored during the test period. Neither of the systems evaluated was ready to serve in bed quality control accurately or fast enough. Particle size distributions according to the bottom ash camera did not correspond to the results of manual sieving. Comprehensive interpretation of the collected AE data requires much experience. Both technologies do have potential and with more research and development they may enable acquiring reliable and real-time information about the bed conditions. This information could help to maintain disturbance-free combustion process and to optimize bottom ash handling system.
Resumo:
Energy generation industry is very capital-intensive industry. Productivity and availability requirements have increased while competition and quality requirement have increased. Maintenance has a significant role that these requirements can be reached. Even maintenance is much more than repairing faults nowadays, spare parts are important part of maintenance. Large power boilers are user-specific therefore features of boilers vary from project to project. Equipment have been designed to follow the customer’s requirements therefore spare parts are mainly user-specific also. The study starts with literature review introducing maintenance, failure mechanisms, and systems and equipment of bubbling fluidized bed boiler. At the final part spare part management is discussed from boiler technology point of view. For this part of the study science publications about spare part management are utilized also some specialist from a boiler technology company and other original equipment manufacturers were interviewed. Spare part management is challenging from the boiler supplier point of view and the end user of spare parts has a responsibility of stocking items. Criticality analysis can be used for finding most critical devices of the process and spare part management shall focus to those items. Spare parts are part of risk management. Stocking spare parts is increasing costs but then high spare part availability is decreasing delay time caused by fault of item.
Resumo:
A study has been conducted focusing on how the phosphorus renrx)val efficiency of a constructed wetland (CW) can be optimized through the selective enrichment of the substratum. Activated alumina and powdered iron were examined as possible enrichment compounds. Using packed glass column trials it was found that alumina was not suitable for the renx)val of ortho-phosphate from solution, while mixtures of powdered iron and quartz sand proved to be very efficient. The evaluation of iron/sand mixtures in CWs planted with cattails was performed in three stages; first using an indoor lab scale wetland, then an outdoor lab scale wetland, and finally in a small scale pilot project. For the lab scale tests, three basic configurations were evaluated: using the iron/sand as a pre-filter, in the root bed. and as a post filter. Primary lagoon effluent was applied to the test cells to simulate actual CW conditions, and the total phosphorus and iron concentrations of the influent and effluent were nfK)nitored. The pilot scale trials were limited to using only a post filter design, due to in-progress research at the pilot site. The lab scale tests achieved average renrK>val efficiencies greater than 91% for all indoor configurations, and greater than 97% for all outdoor configurations. The pilot scale tests had an average renK)val efficiency of 60%. This relatively low efficiency in the pilot scale can be attributed to the post filters being only one tenth the size of the lab scale test in terms of hydraulic loading (6 cm/day vs. 60 cm/day).
Resumo:
The Falkland Islands War of 1982 was fought over competing claims to sovereignty over a group of islands off the east coast of South America. The dispute was between Argentina and the United Kingdom. Argentina claims the islands under rights to Spanish succession, the fact that they lie off the Argentine coast line and that in 1833 Great Britain took the islands illegally and by force. The United Kingdom claims the islands primarily through prescription--the fact that they have governed the islands in a peaceful, continuous and public manner since 1833. The British also hold that the population living on the islands, roughly eighteen hundred British descendants, should be able to decide their own future. The United Kingdom also lays claim to the islands through rights of discovery and settlement, although this claim has always been challenged by Spain who until 1811 governed the islands. Both claims have legal support, and the final decision if there will ever be one is difficult to predict. Sadly today the ultimate test of sovereignty does not come through international law but remains in the idea that "He is sovereign who can defend his sovereignty." The years preceding the Argentine invasion of 1982 witnessed many diplomatic exchanges between The United Kingdom and Argentina over the future of the islands. During this time the British sent signals to Argentina that ii implied a decline in British resolve to hold the islands and demonstrated that military action did more to further the talks along than did actual negotiations. The Argentine military junta read these signals and decided that they could take the islands in a quick military invasion and that the United Kingdom would consider the act as a fait accompli and would not protest the invasion. The British in response to this claimed that they never signaled to Argentina that a military solution was acceptable to them and launched a Royal Navy task force to liberate the islands. Both governments responded to an international crisis with means that were designed both to resolve the international crisis and increase the domestic popularity of the government. British Prime Minister Margaret Thatcher was facing an all-time low in popularity for post-War Prime Ministers while Argentine President General Galtieri needed to gain mass popular support so he could remain a viable President after he was scheduled to lose command of the army and a seat on the military junta that ran the country. The military war for the Falklands is indicative of the nature of modern warfare between Third World countries. It shows that the gap in military capabilities between Third and First World countries is narrowing significantly. Modern warfare between a First and Third World country is no longer a 'walk over' for the First World country.
Resumo:
Transcribed on front paste-down: W.G. Phelps Oct. 29 1890.
Resumo:
Survey map of the Second Welland Canal created by the Welland Canal Company showing the canal in Thorold South. Identified structures associated with the Canal include the Little Deep Cut and the towing path. The surveyors' measurements and notes can be seen in red and black ink and pencil. Local area landmarks are also identified and include streets and roads (ex. Road to Beaverdams and Road to Allanburgh), two unnamed bridges, the Spoil Bank, a pond, and the Back Water. Properties and property owners of note are: Lots 29 and 30, Jacob Keefer, John Brown, William Bouck, C. Gisso, and a property reserved for Bridge Tender.
Resumo:
Survey map of the Second Welland Canal created by the Welland Canal Company showing the canal in the Thorold Township just south of Allanburgh. Identified structures and features associated with the Canal include the Deep Cut and the towing path. The surveyors' measurements and notes can be seen in red and black ink and pencil. Local area landmarks are also identified and include streets and roads (ex. Road to Port Robinson), and the Spoil Bank. Properties and property owners of note are: Lots 142 and 143, John J. Church, Henry Vanderburgh, and Martin Delamatter and G. Coulter.