952 resultados para chromium


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heavy metals can cause problems of human poisoning by ingestion of contaminated food, and the environment, a negative impact on the aquatic fauna and flora. And for the presence of these metals have been used for aquatic animals biomonitoramento environment. This research was done in order to assess the environmental impact of industrial and domestic sewage dumped in estuaries potiguares, from measures of heavy metals in mullet. The methods used for these determinations are those in the literature for analysis of food and water. Collections were 20 samples of mullet in several municipality of the state of Rio Grande do Norte, from the estuaries potiguares. Were analyzed the content of humidity, ash and heavy metals. The data were subjected to two methods of exploratory analysis: analysis of the main components (PCA), which provided a multivariate interpretation, showing that the samples are grouped according to similarities in the levels of metals and analysis of hierarchical groupings (HCA), producing similar results. These tests have proved useful for the treatment of the data producing information that would hardly viewed directly in the matrix of data. The analysis of the results shows the high levels of metallic species in samples Mugil brasiliensis collected in Estuaries /Potengi, Piranhas/Açu, Guaraíra / Papeba / Arês and Curimataú

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Leather tanneries generate effluents with high content of heavy metals, especially chromium, which is used in the mineral tanning process. Microemulsions have been studied in the extraction of heavy metals from aqueous solutions. Considering the problems related with the sediment resulting from the tanning process, due to its high content in chromium, in this work this sediment was characterized and microemulsion systems were applied for chromium removal. The extraction process consists in the removal of heavy metal ions present in an aqueous feeding solution (acid digestion solution) by a microemulsion system. First three different solid sludge digestion methods were evaluated, being chosen the method with higher digestion capacity. For this digestion method, seeking its optimization, was evaluated the influence of granule size, temperature and digestion time. Experimental results showed that the method proposed by USEPA (Method A) was the most efficient one, being obtained 95.77% of sample digestion. Regarding to the evaluated parameters, the best results were achieved at 95°C, 14 Mesh granule size, and 60 minutes digestion time. For chromium removal, three microemulsion extraction methods were evaluated: Method 1, in a Winsor II region, using as aqueous phase the acid digestion solution; Method 2, in a Winsor IV region, being obtained by the addition of the acid digestion solution to a microemulsion phase, whose aqueous phase is distilled water, until the formation of Winsor II system; and Method 3, in a Winsor III region, consisting in the formation of a Winsor III region using as aqueous phase the acid digestion solution, diluted in NaOH 0.01N. Seeking to optimize the extraction process only Method 1 (Systems I, II, and VIII) and Method 2 (System IX) were evaluated, being chosen points inside the interest regions (studied domains) to study the influence of contact time and pH in the extraction percentiles. The studied systems present the following compositions: System I: Surfactant Saponified coconut oil, Cosurfactant 1-Butanol, Oil phase Kerosene, Aqueous phase 2% NaCl solution; System II: Aqueous phase Acid digestion solution with pH adjusted using KOH (pH 3.5); System VIII: Aqueous phase - Acid digestion solution (pH 0.06); and System IX Aqueous phase Distilled water (pH 10.24), the other phases of Systems II, VIII and IX are similar to System I. Method 2 showed to be the more efficient one regarding chromium extraction percentile (up to 96.59% - pH 3.5). Considering that with Method 2 the microemulsion region only appears in the Winsor II region, it was studied Method 3 (System X) for the evaluation and characterization of a triphasic system, seeking to compare with a biphases system. System X is composed by: Surfactant Saponified coconut oil, Cosurfactant 1-Butanol, Oil phase Kerosene, Aqueous phase Acid digestion solution diluted with water and with its pH adjusted using 0.01N NaOH solution. The biphasic and triphasic microemulsion systems were analyzed regarding its viscosity, extraction efficiency and drop effective diameter. The experimental results showed that for viscosity studies the obtained values were low for all studied systems, the diameter of the drop is smaller in the Winsor II region, with 15.5 nm, reaching 46.0 nm in Winsor III region, being this difference attributed to variations in system compositions and micelle geometry. In chromium extraction, these points showed similar results, being achieved 99.76% for Winsor II system and 99.62% for Winsor III system. Winsor III system showed to be more efficient due to the obtaining of a icroemulsion with smaller volume, with the possibility to recover the oil phase in excess, and the use of a smaller proportion of surfactant and cosurfactant (C/S)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work was to carry out a study on the adsorption of hydrogen sulfide (H2S) in arrays synthesized from a commercial clay mineral formed by a mixture of dolomite and quartz. To produce the ion exchange matrix were made using aqueous solutions of salts of cobalt II chloride hexahydrate (CoCl2.6H2O) II cadmium nitrate tetrahydrate (Cd (NO3)2.4H2O) I mercuric chloride (HgCl) nitrate and chromium III pentahydrate (Cr (NO3)3.5H2O). The arrays were subjected to hydrogen sulphide gas passage for one hour. To check the amount of gas adsorbed was used gravimetric process. The best result was in the adsorption matrix doped with cadmium and the solution retained for a longer time than the largest amount of H2S was the cobalt matrix. The matrix unmodified exhibited poor adsorption capacity. The characterization of the matrices were used XRD, XRF and IV. Mother with cadmium showed a high capacity in ion exchange, because the percentage of cadmium increased from 0% to 81.38% by replacing atoms of calcium and silicon which increased from 96.54% to 17.56% and 15, 72% to 0.32%, respectively, but also the best performance in adsorption of H2S adsorbing 11.89507 mg per gram of matrix

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to analyze the phytoremediation potential of Eichhornia crassipes in natural environments, optimize the extraction process of crude protein from plant tissue and, obtain and characterize this process in order to determine its viability of use instead of the protein sources of animal and/or human feed. For this, it has been determined in Apodi/Mossoró river water the concentration of ammonium ions, nitrite, nitrate, calcium, magnesium, potassium, iron, copper, manganese, zinc, nickel, cobalt, sodium, aluminum, cádmium, lead, and total chromium; It was determined in plant tissue of aquatic macrophytes of Eichhornia crassipes species present in Apodi/Mossoró River the moisture content, ash, calcium, magnesium, potassium, iron, copper, manganese, zinc, nickel, cobalt, sodium, aluminum, cadmium, lead, total chromium, total nitrogen and crude protein. It was also determined the translocation factor and bioaccumulation of all the quantified elements; It was developed and optimized the extraction procedure of crude protein based on the isoelectric method and a factorial design 24 with repetition; It was extracted and characterized the extract obtained by determining the moisture content, ash, magnesium, potassium, iron, copper, manganese, zinc, nickel, cobalt, sodium, cadmium, total nitrogen and crude protein. And finally, it was also characterized the protein extract using Thermogravimetric Analysis (TG), Derived Thermogravimetric (DTG), Differential Scanning Calorimetry (DSC), Infrared Spectroscopy (FT-IR) and jelly-like electrophoresis of polyacrylamide (SDS -PAGE) to assess the their molecular weights/mass. Thus, from the results obtained for the translocation and bioaccumulation factors was found that the same can be used as phytoremediation agent in natural environments of all quantified elements. It was also found that the developed method of extraction and protein precipitation was satisfactory for the purpose of the work, which gave the best conditions of extraction and precipitation of proteins as: pH extraction equal to 13.0, extraction temperature equals 60 ° C, reaction time equals to 30 minutes, and pH precipitation equals to 4.0. As for the extract obtained, the total nitrogen and crude protein were quantified higher than those found in the plant, increasing the crude protein content approximately 116.88% in relation to the quantified contente in the vegetal tissue of macrophyte. The levels of nickel and cadmium were the unique that were found below the detection limit of used the equipment. The electrophoretic analysis allowed us to observe that the protein extract obtained is composed of low polypeptide chains by the molecular and phytochelatins, with 6 and 15 kDa bands. Analysis of TG, DTG, DSC and FT-IR showed similarities in protein content of the obtained extracts based on different collection points and 9 parts of the plant under study, as well as commercial soy protein and casein. Finally, based on all these findings, it was concluded that the obtained extract in this work can be used instead of the protein sources of animal feed should, before that, test its digestibility. As human supplementation, it is necessary to conduct more tests associated with the optimization process in the sense of removing undesirable components and constant monitoring of the water body and the raw material used

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to compare the misfit vertical, horizontal and passivity of zirconia and cobalt-chromium frameworks fabricated for CAD / CAM technology and conventional method of casting. Sixteen frameworks in one-piece, were obtained from a metallic matrix containing three Brånemark compatible implants with regular platform (Titamax Cortical Ti, Neodent). Eight frameworks were fabricated by CAD / CAM system (NeoShape, Neodent): four in zirconia (ZirCAD) and four cobalt-chromium (CoCrcad). Eight other frameworks were obtained by conventional casting method: four cobalt-chromium with UCLA abutment premachined Co-Cr (CoCrUCci) and four cobalt-chromium with UCLA abutment castable (CoCrUCc). The fit vertical, horizontal and passivity by one-screw test were measured using scanning electron microscopy with magnification of 250x. Initially evaluated the passivity by one-screw test and subsequently to assess the vertical and horizontal misfit, tightened all the screws with a torque of 20 Ncm. Mean, standard deviation, minimum and maximum values were calculated for each group. Measurements of horizontal misfit were transformed into cumulative frequency for categorization of the variable and the group later comparison groups. To evaluate the existence of quantitative differences between the groups tested for vertical misfit and passivity, we used the Kruskal-Wallis test. The Mann-Whitney test was used to compare group to group statistical differences (p <0.05). Were observed the respective mean and standard deviation for vertical misfit and passivity in micrometers: ZirCAD (5.9 ± 3.6, 107.2 ± 36), CoCrcad (1.2 ± 2.2, 107.5 ± 26 ), CoCrUCci (11.8 ± 9.8, 124.7 ± 74), CoCrUCc (12.9 ± 11.0, 108.8 ± 85). There were statistical differences in measures of vertical misfit (p = 0.000). The Mann-Whitney test revealed statistical differences (p <0.05) between all groups except between CoCrUCci and CoCrUCc (p = 0.619). No statistical difference was observed for the passivity. In relation to the horizontal misfit groups ZirCAD and CoCrcad did not show best values in relation to CoCrUCci and CoCrUCc. Based on the results it can be concluded that frameworks fabricated by CAD / CAM technology had better values of vertical fit than those manufactured by the casting method, nevertheless, the passivity was not influenced by manufacturing technique and material used. The horizontal fit obtained by frameworks manufactured by CAD / CAM was not superior to those manufactured by casting. A lower variability in vertical adjustment and passivity was observed when frameworks were fabricated by CAD / CAM technology

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this research was to evaluate the passivity and strain induced in infrastructures screwed on abutments, made by CAD/CAM technology, and to compare these samples with parts manufactured by conventional casting. Using CAD/CAM technology, 4 samples were made from zirconia (Zircad) and 4 samples were manufactured from cobaltchrome (CoCrcad). The control groups were 4 specimens of cobalt-chrome, made by onepiece casting (CoCrci), for a total of 12 infrastructures. To evaluate the passivity, the infraestructures were installed on the abutments. One end was tightened and the vertical gap between the infrastructure and the prosthetic abutment was measured with scanning electron microscopy (250×). The mean strain in these infrastructures was analyzed via the photoelasticity test. A significant difference (p = 0.000) in passivity was observed between the control (CoCrci) and sample groups (CoCrcad and CoCrci). CoCrcad exhibited the best value of passivity (48.76 ± 13.45 μm) and CoCrci the worst (187.55 ± 103.63 μm), Zircad presented an intermediate value (103.81 ± 43.15 μm). When compared to the other groups, CoCrci showed the highest mean strain around the implants (17.19 ± 7.22 kPa). It was concluded that the zirconia infrastructure made by CAD / CAM showed a higher vertical marginal misfit than those made in cobalt-chromium alloy with the same methodology, however, the tension generated in the implants was similar. The CAD/CAM technology is more accurate for passivity and mean strain of infrastructure screwed on abutments than conventional manufacturing techniques

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective-To evaluate the cardiorespiratory and intestinal effects of the muscarinic type-2 (M-2) antagonist, methoctramine, in anesthetized horses.Animals-6 horses.Procedure-Horses were allocated to 2 treatments in a randomized complete block design. Anesthesia was maintained with halothane (1% end-tidal concentration) combined with a constant-rate infusion of xylazine hydrochloride (1 mg/kg/h, IV) and mechanical ventilation. Hemodynamic variables were monitored after induction of anesthesia and for 120 minutes after administration of methoctramine or saline (0.9% NaCl) solution (control treatment). Methoctramine was given at 10-minute intervals (10 mug/kg, IV) until heart rate (HR) increased at least 30% above baseline values or until a maximum cumulative dose of 30 mug/kg had been administered. Recovery characteristics, intestinal auscultation scores, and intestinal transit determined by use of chromium oxide were assessed during the postanesthetic period.Results-Methoctramine was given at a total cumulative dose of 30 mug/kg to 4 horses, whereas 2 horses received 10 mug/kg. Administration of methoctramine resulted in increases in HR, cardiac output, arterial blood pressure, and tissue oxygen delivery. Intestinal auscultation scores and intestinal transit time (interval to first and last detection of chromium oxide in the feces) did not differ between treatment groups.Conclusions and Clinical Relevance-Methoctramine improved hemodynamic function in horses anesthetized by use of halothane and xylazine without causing a clinically detectable delay in the return to normal intestinal motility during the postanesthetic period. Because of their selective positive chronotropic effects, M-2 antagonists may represent a safe alternative for treatment of horses with intraoperative bracycardia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim was to evaluate the nutritional value of the root and leaves of cassava (Manihot sculenta) for juveniles of Nile tilapia (Oreochromis niloticus). Three diets were prepared, a reference and two test diets. The first tested diet contained 50.0% of cassava root and 50.0% of reference diet and the second one consisted of 30.0% of cassava leaf meal and 70.0% of reference diet. Moreover, in every diet was added 0.1% chromium oxide-III (Cr2O3) as inert marker. Sixty juveniles (100.0 +/- 9.0 g) were accommodated in cages (10 fish/cage) for feeding and feces collection. During the day these cages were maintained in a feeding tank (250 L), one tank for each treatment, where they were fed until apparent satiation. After the aforementioned feeding period they were transferred to a fecal collection tank, where they remained until next morning. The collected feces were frozen and dried for analyzes. The apparent digestibility coefficients (ADC) were calculated on basis of Cr2O3 concentration present in diets and feces. The ADC of reference diet for DM, cassava leaf and root were, respectively 85.23%, 81.22% and 91.44%; CP to 97.35%, 73.37% and 91.46% and for the GE to 87.70%, 64.70% and 92.20%, the values obtained for the diet with cassava root significantly higher (P<0.05). Summarizing, root and cassava leaves can be used as alternative ingredients for compose balanced diets for Nile tilapia juveniles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A sensibilidade do método espectrofotométrico da s-difenilcarbazida de determinação do crômio permite que esse metal possa ser determinado em teores e em massas de amostras tão pequenas que as concentrações atualmente usadas de óxido de crômio (III) como marcador externo em ensaios biológicos poderiam ser drasticamente diminuídas. Utilizando-se do piauçu (Leporinus macrocephalus) para um estudo sobre o coeficiente de digestibilidade aparente (CDA) da fração protéica, seis níveis de óxido de crômio (III) - 0,01% - 0,02% - 0,03% - 0,05% - 0,1% e 0,2% - foram incorporados em dietas isoprotéica e isoenergética, objetivando-se verificar se o cálculo do CDA seria afetado pela variação do teor do marcador. Os seis tratamentos foram dispostos em um delineamento em blocos inteiramente casualisados, sendo as fezes coletadas durante 16 dias. Verificou-se que os resultados do coeficiente de digestibilidade aparente da fração protéica não apresentaram diferenças estatísticas significativas devidas aos teores incorporados do marcador à ração e aos dias de coleta. Conseqüentemente, e em experimentos dessa natureza, nada impede que seja reduzido o teor de óxido de crômio (III) ao menos até 0,01%: além da economia relativa ao consumo do mesmo e da facilidade na manipulação de menor quantidade de amostras de fezes, o método espectrofotométrico da s-difenilcarbazida permite dosar esse nível (e até menor do que 0,01%) de modo simples e rápido, com precisão e exatidão.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivou-se avaliar o efeito da suplementação com cromo complexado à molécula orgânica do suplemento no desempenho produtivo, nas características de carcaça e na qualidade da carne de bovinos terminados em regime de pastagem. Foram utilizados 18 bovinos Nelore e 18 F1 Brangus × Nelore castrados, com 16 meses de idade, mantidos com suplementação mineral protéica, com ou sem cromo complexado à molécula orgânica e abatidos aos 22 meses de idade. O ganho médio diário de peso vivo (GMD) não diferiu entre grupos genéticos, entretanto animais mantidos com suplemento contendo cromo apresentaram maior GMD (494 g) em comparação aos demais (420 g). A adição de cromo orgânico no suplemento não promoveu alterações na área de olho-de-lombo (63,42 cm²) e na espessura de gordura subcutânea do dorso (5,46 mm) e da garupa (5,58 mm), tomados por meio do ultra-som. O peso médio de carcaça quente foi 235 kg e o rendimento médio de carcaça quente, 52,09%, com superioridade do suplemento contendo cromo (238 kg e 52,9%) em relação ao controle (231 kg e 51,2%). Animais Nelore e F1 Brangus × Nelore apresentam potencial similar de produção de carne a pasto. A suplementação mineral protéica com adição de cromo complexado à molécula orgânica aumenta o ganho de peso e o rendimento de carcaça, mas não influencia os parâmetros qualitativos da carne.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns.Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05).Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05).Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the effect of mechanical cycling and different misfit levels on Vicker's microhardness of retention screws for single implant-supported prostheses.Materials and Methods: Premachined UCLA abutments were cast with cobalt-chromium alloy to obtain 48 crowns divided into four groups (n = 12). The crowns presented no misfit in group A (control group) and unilateral misfits of 50 mu m, 100 mu m, and 200 mu m in groups B, C, and D, respectively. The crowns were screwed to external hexagon implants with titanium retention screws (torque of 30 N/cm), and the sets were submitted to three different periods of mechanical cycling: 2 x 10(4), 5 x 10(4), and 1 x 10(6) cycles. Screw microhardness values were measured before and after each cycling period. Data were evaluated by two-way ANOVA and Tukey's test (p < 0.05).Results: Mechanical cycling statistically reduced microhardness values of retention screws regardless of cycling periods and groups. In groups A, B, and C, initial microhardness values were statistically different from final microhardness values (p < 0.05). There was no statistically significant difference for initial screw microhardness values (p > 0.05) among the groups; however, when the groups were compared after mechanical cycling, a statistically significant difference was observed between groups B and D (p < 0.05).Conclusions: Mechanical cycling reduced the Vicker's microhardness values of the retention screws of all groups. The crowns with the highest misfit level presented the highest Vicker's microhardness values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives. This study was undertaken to evaluate the shear bond strength of four materials used as aesthetic material bonded to Ni-Cr alloy.Methods. Sixty-eight alloy discs were prepared and divided equally into four groups, and received four treatments for veneering: conventional feldspathic porcelain (Noritake EX-3) and three light-cured prosthodontic composite resins (Artglass, Solidex and Targis). The aesthetic materials were applied after metal structure conditioning in accordance with the manufacturers' recommendations. The specimens were stored in distilled water at 37 degreesC for 7 days. A universal testing machine was used to measure the shear bond strength of the specimens at a cross head speed of 0.5 mm/min. Fractured specimens were examined by using both optical and scanning electron microscope.Results. The analysis of variance and Tukey's test showed that the strongest mean shear bond was obtained with Noritake EX-3 (mean shear bond strength 42.90 +/- 7.82 MPa). For composites, the highest mean shear bond strength was observed for Targis (12.30 +/- 1.57 MPa); followed by Solidex (11.94 +/- 1.04 MPa) and Artglass (10.04 +/- 0.75 MPa). Optical analysis of the fractured surf aces indicated that for Targis and Noritake EX-3 all failures were a mixture of both cohesive and adhesive patterns. As for Artglass and Solidex, the fractures were mainly adhesive in nature.Conclusions. The Solidex system was equivalent to the Targis system in bond strength and exhibited greater strength than the Artglass system. The porcelain fused-to-metal showed considerably higher shear bond strength than the three metal-resin bonding techniques. (C) 2003 Elsevier B.V. Ltd. Ali rights reserved.