984 resultados para X-rays: individual (SWIFT J195509.6 261406)
Resumo:
We report a case of a 49 years-old man who underwent a barium meal examination for an epigastric pain. A perforated gastric ulcer with barium extravasation into peritoneal cavity was seen on X-rays. During an emergency laparotomy, a perforated pyloric ulcer was noted, along with barium contamination in the peritoneal cavity. The ulcer was closed with an omental patch and an extensive peritoneal lavage with saline was performed. During the postoperative period, the patient developed signs of peritonitis and underwent a new laparotomy was at the 9th day showing a subfrenic abscess with a large barium contamination. The patient presented septic shock and multiple organ failure. dying on the 21th day.
Resumo:
This is a case report on Hereditary Multiple Osteochondromatosis (HMO) with rib involvement. The authors present aspects of thoracic surface anatomy, and thoracic images (X-rays, computed tomography, magnetic nuclear resonance), as well as the operating procedure.
Resumo:
Bioactive glasses (BGs) form a group of synthetic, surface-active, composition-dependent, silica-based biomaterials with osteoconductive, osteopromotive, and even angiogenic, as well as antibacterial, properties. A national interdisciplinary research group, within the Combio Technology Program (2003–2007), developed a porous load-bearing composite for surgical applications made of BG 1–98 and polymer fibers. The pre-clinical part of this thesis focused on the in vitro and in vivo testing of the composite materials in a rabbit femur and spinal posterolateral fusion model. The femur model failed to demonstrate the previously seen positive effect of BG 1–98 on osteogenesis, probably due to the changed resorption properties of BG in the form of fibers. The spine study was terminated early due to adverse events. In vitro cultures showed the growth inhibition of human mesenchymal stems next to BG 1–98 fibers and radical pH changes. A prospective, long-term, follow-up study was conducted on BG–S53P4 and autogenous bone used as bone graft substitutes for instrumented posterolateral spondylodesis in the treatment of degenerative spondylolisthesis (n=17) and unstable burst fractures (n=10) during 1996–1998. The operative outcome was evaluated from X-rays and CT scans, and a clinical examination was also performed. On the BG side, a solid fusion was observed in the CT scans of 12 patients, and a partial fusion was found in 5 patients, the result being a total fusion rate in all fusion sites (n=41) 88% for levels L4/5 and L5/S1 in the spondylolisthesis group. In the spine fracture group, solid fusion was observed in five patients, and partial fusion was found in five resulting in a total fusion rate of 71% of all fusion sites (n=21). The pre-clinical results suggest that under certain conditions the physical form of BG can be more critical than its chemical composition when a clinical application is designed. The first long-term clinical results concerning the use of BG S53P4 as bone graft material in instrumented posterolateral spondylodesis seems to be a safe procedure, associated with a very low complication rate. BG S53P4 used as a stand-alone bone substitute cannot be regarded as being as efficient as AB in promoting solid fusion.
Resumo:
Irtokartta
Resumo:
Kartta kuuluu A. E. Nordenskiöldin kokoelmaan
Resumo:
The characterization of proteins from Brucella spp, the causative agent of brucellosis, has been the subject of intensive research. We have described an 18-kDa cytoplasmic protein of Brucella abortus and shown the potential usefulness of this protein as an antigen for the serologic diagnosis of brucellosis. The amino acid sequence of the protein showed a low but significant homology with that of lumazine synthases. Lumazine is an intermediate product in bacterial riboflavin biosynthesis. The recombinant form of the 18-kDa protein (expressed in E. coli) folds like the native Brucella protein and has lumazine-synthase enzymatic activity. Three-dimensional analysis by X-ray crystallography of the homolog Bacillus subtilis lumazine synthase has revealed that the enzyme forms an icosahedral capsid. Recombinant lumazine synthase from B. abortus was crystallized, diffracted X rays to 2.7-Å resolution at room temperature, and the structure successfully solved by molecular replacement procedures. The macromolecular assembly of the enzyme differs from that of the enzyme from B. subtilis. The Brucella enzyme remains pentameric (90 kDa) in its crystallographic form. Nonetheless, the active sites of the two enzymes are virtually identical at the structural level, indicating that inhibitors of these enzymes could be viable pharmaceuticals across a broad species range. We describe the structural reasons for the differences in their quaternary arrangement and also discuss the potential use of this protein as a target for the development of acellular vaccines.
Resumo:
Several natural compounds have been identified for the treatment of leishmaniasis. Among them are some alkaloids, chalcones, lactones, tetralones, and saponins. The new compound reported here, 7-geranyloxycoumarin, called aurapten, belongs to the chemical class of the coumarins and has a molecular weight of 298.37. The compund was extracted from the Rutaceae species Esenbeckia febrifuga and was purified from a hexane extract starting from 407.7 g of dried leaves and followed by four silica gel chromatographic fractionation steps using different solvents as the mobile phase. The resulting compound (47 mg) of shows significant growth inhibition with an LD50 of 30 µM against the tropical parasite Leishmania major, which causes severe clinical manifestations in humans and is endemic in the tropical and subtropical regions. In the present study, we investigated the atomic structure of aurapten in order to determine the existence of common structural motifs that might be related to other coumarins and potentially to other identified inhibitors of Leishmania growth and viability. This compound has a comparable inhibitory activity of other isolated molecules. The aurapten is a planar molecule constituted of an aromatic system with electron delocalization. A hydrophobic side chain consisting of ten carbon atoms with two double bonds and negative density has been identified and may be relevant for further compound synthesis.
Resumo:
Leptin is produced primarily by adipocytes. Although originally associated with the central regulation of satiety and energy metabolism, increasing evidence indicates that leptin may be an important mediator in cardiovascular pathophysiology. The aim of the present study was to investigate plasma leptin levels in patient with Chagas' heart disease and their relation to different forms of the disease. We studied 52 chagasic patients and 30 controls matched for age and body mass index. All subjects underwent anthropometric, leptin and N-terminal pro-brain natriuretic peptide (NT-proBNP) measurements and were evaluated by echocardiography, 12-lead electrocardiogram (ECG), and chest X-ray. All patients had fasting blood samples taken between 8:00 and 9:00 am. Chagasic patients were divided into 3 groups: group I (indeterminate form, IF group) consisted of 24 subjects with 2 positive serologic reactions for Chagas' disease and no cardiac involvement as evaluated by chest X-rays, ECG and two-dimensional echocardiography; group II (showing ECG abnormalities and normal left ventricular systolic function, ECG group) consisted of 14 patients; group III consisted of 14 patients with congestive heart failure (CHF group) and left ventricular dysfunction. Serum leptin levels were significantly lower (P < 0.001) in the CHF group (1.4 ± 0.8 ng/mL) when compared to the IF group (5.3 ± 5.3 ng/mL), ECG group (9.7 ± 10.7 ng/mL), and control group (8.1 ± 7.8 ng/mL). NT-proBNP levels were significantly higher (P < 0.001) in the CHF group (831.8 ± 800.1 pg/mL) when compared to the IF group (53.2 ± 33.3 pg/mL), ECG group (83.3 ± 57.4 pg/mL), and control group (32 ± 22.7 pg/mL). Patients with Chagas' disease and an advanced stage of CHF have high levels of NT-ProBNP andlow plasma levels of leptin. One or more leptin-suppressing mechanisms may operate in chagasic patients.
Resumo:
Ancien possesseur : Simony, Charles de (Cte Anne Marie Charles de)
Resumo:
The heritability of multiple mating in female Gryllus integer crickets was studied. Two preliminary experiments were conducted to determine when females first mate following the post-imaginal moult and to ascertain whether constant exposure to males affects female mating rate. Female Q. integer first mated at an average age of 3.6 days (S.D. = 2.3, Range = 0-8 days) . Exposing female crickets to courting males 24 hr daily did not significantly alter mating rates from those females in contact with males for only 5 hr per day. A heritability value of 0.690 ± 0.283 was calculated for multiple mating behavior in female Q. integer using a parent-offspring regression approach. Parental females mated between land 30 times (x 9.8, S . D. = 6. 6 ) and offspring matings ranged from 0 to 26 times (x 7 .3, S.D. = 3.4). Multiple mating is probably a sexually selected trait which functions as a mechanism of female choice and increases reproductive success through increased offspring production. Classical theory suggests that traits intimately related with fitness should exhibit negligible heritable variation. However, this study has shown that multiple mating, a trait closely linked with reproductive fitness, exhibits substantial heritability. These results are in concordance with a growing body of empirical evidence suggesting many fitness traits in natural populations demonstrate heritabilities far removed from zero. Various mechanisms which may maintain heritable variation for female multiple mating in wild, outbred Q. integer populations are discussed.
Resumo:
We report the results of crystal structure, magnetization and resistivity measurements of Bi doped LaVO3. X-ray diffraction (XRD) shows that if doping Bi in the La site is less than ten percent, the crystal structure of La1-xBixVO3 remains unchanged and its symmetry is orthorhombic. However, for higher Bi doping (>10%) composite compounds are found where the XRD patterns are characterized by two phases: LaVO3+V2O3. Energy-dispersive analysis of the x-ray spectroscopy (EDAX) results are used to find a proper atomic percentage of all samples. The temperature dependence of the mass magnetization of pure and single phase doped samples have transition temperatures from paramagnetic to antiferromagnetic region at TN=140 K. This measurement for bi-phasic samples indicates two transition temperatures, at TN=140 K (LaVO3) and TN=170 K (V2O3). The temperature dependence of resistivity reveals semiconducting behavior for all samples. Activation energy values for pure and doped samples are extracted by fitting resistivity versus temperature data in the framework of thermal activation process.
Resumo:
La scoliose idiopathique (SI) est une déformation tridimensionnelle (3D) de la colonne vertébrale et de la cage thoracique à potentiel évolutif pendant la croissance. Cette déformation 3D entraîne des asymétries de la posture. La correction de la posture est un des objectifs du traitement en physiothérapie chez les jeunes atteints d’une SI afin d’éviter la progression de la scoliose, de réduire les déformations morphologiques et leurs impacts sur la qualité de vie. Les outils cliniques actuels ne permettent pas de quantifier globalement les changements de la posture attribuables à la progression de la scoliose ou à l’efficacité des interventions thérapeutiques. L’objectif de cette thèse consiste donc au développement et à la validation d’un nouvel outil clinique permettant l’analyse quantitative de la posture auprès de personnes atteintes d’une SI. Ce projet vise plus spécifiquement à déterminer la fidélité et la validité des indices de posture (IP) de ce nouvel outil clinique et à vérifier leur capacité à détecter des changements entre les positions debout et assise. Suite à une recension de la littérature, 34 IP représentant l’alignement frontal et sagittal des différents segments corporels ont été sélectionnés. L’outil quantitatif clinique d’évaluation de la posture (outil 2D) construit dans ce projet consiste en un logiciel qui permet de calculer les différents IP (mesures angulaires et linéaires). L’interface graphique de cet outil est conviviale et permet de sélectionner interactivement des marqueurs sur les photographies digitales. Afin de vérifier la fidélité et la validité des IP de cet outil, la posture debout de 70 participants âgés entre 10 et 20 ans atteints d'une SI (angle de Cobb: 15º à 60º) a été évaluée à deux occasions par deux physiothérapeutes. Des marqueurs placés sur plusieurs repères anatomiques, ainsi que des points de référence anatomique (yeux, lobes des oreilles, etc.), ont permis de mesurer les IP 2D en utilisant des photographies. Ces mêmes marqueurs et points de référence ont également servi au calcul d’IP 3D obtenus par des reconstructions du tronc avec un système de topographie de surface. Les angles de Cobb frontaux et sagittaux et le déjettement C7-S1 ont été mesurés sur des radiographies. La théorie de la généralisabilité a été utilisée pour déterminer la fidélité et l’erreur standard de la mesure (ESM) des IP de l’outil 2D. Des coefficients de Pearson ont servi à déterminer la validité concomitante des IP du tronc de l’outil 2D avec les IP 3D et les mesures radiographiques correspondantes. Cinquante participants ont été également évalués en position assise « membres inférieurs allongés » pour l’étude comparative de la posture debout et assise. Des tests de t pour échantillons appariés ont été utilisés pour détecter les différences entre les positions debout et assise. Nos résultats indiquent un bon niveau de fidélité pour la majorité des IP de l’outil 2D. La corrélation entre les IP 2D et 3D est bonne pour les épaules, les omoplates, le déjettement C7-S1, les angles de taille, la scoliose thoracique et le bassin. Elle est faible à modérée pour la cyphose thoracique, la lordose lombaire et la scoliose thoraco-lombaire ou lombaire. La corrélation entre les IP 2D et les mesures radiographiques est bonne pour le déjettement C7-S1, la scoliose et la cyphose thoracique. L’outil est suffisamment discriminant pour détecter des différences entre la posture debout et assise pour dix des treize IP. Certaines recommandations spécifiques résultents de ce projet : la hauteur de la caméra devrait être ajustée en fonction de la taille des personnes; la formation des juges est importante pour maximiser la précision de la pose des marqueurs; et des marqueurs montés sur des tiges devraient faciliter l’évaluation des courbures vertébrales sagittales. En conclusion, l’outil développé dans le cadre de cette thèse possède de bonnes propriétés psychométriques et permet une évaluation globale de la posture. Cet outil devrait contribuer à l’amélioration de la pratique clinique en facilitant l’analyse de la posture debout et assise. Cet outil s’avère une alternative clinique pour suivre l’évolution de la scoliose thoracique et diminuer la fréquence des radiographies au cours du suivi de jeunes atteints d’une SI thoracique. Cet outil pourrait aussi être utile pour vérifier l’efficacité des interventions thérapeutiques sur la posture.
Resumo:
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal
Resumo:
La scoliose idiopathique de l’adolescence (SIA) est une déformation tridimensionnelle de la colonne vertébrale et de la cage thoracique dont la cause est inconnue. Il semble que la ceinture pelvienne soit impliquée dans la pathogénie de la SIA, car des différences géométriques des os coxaux ont été observées. Notamment, une rotation du bassin ou une inclinaison latérale dans le sens de la courbe scoliotique ont été mises en évidence en plus des distorsions osseuses. Il est difficile de dissocier la rotation du bassin de son asymétrie, car la majorité des études porte sur des données radiologiques bidimensionnelles. Une analyse tridimensionnelle de la morphologie du bassin de patientes ayant une SIA, mais n’ayant pas reçu de traitement par corset ou chirurgie permettrait d’identifier le rôle du bassin dans la progression de la scoliose. Dix-sept jeunes filles atteintes de la SIA ont participé à cette étude pour lesquelles des radiographies bi-planaires en station debout étaient disponibles au moment du diagnostic par un chirurgien orthopédiste pédiatrique et à l’instant de la prescription d'un corset. Des radiographies postéro-antérieures et latérales avaient été prises au moyen du système EOS®. Douze repères anatomiques du bassin ont été identifiés sur les paires de radiographies, alors que quatre repères ont été identifiés sur la radiographie postéro-antérieure uniquement. Ces quatre derniers n’étaient pas identifiables sur la radiographie latérale à cause de la superposition des repères droits et gauches. La reconstruction tridimensionnelle du bassin a été réalisée à partir de deux clichés radiographiques des 12 premiers repères osseux. Au total, neuf paramètres tridimensionnels ont été calculés afin de quantifier l’asymétrie et la distorsion du bassin entre les deux temps donnés. Des paramètres bidimensionnels ont également été mesurés sur les quatre derniers repères osseux afin de documenter des déformations du bassin pertinentes à la pratique clinique, telle que la rotation axiale de celui-ci. Dans le but d'évaluer une possible asymétrie entre les os coxaux du bassin, les paramètres tridimensionnels du bassin gauche ont été comparés à ceux du côté droit à chaque temps, au moyen d'un test-t pour échantillon apparié. La morphologie pelvienne a été également évaluée par l'analyse multivariée (MANOVA) à mesures répétées à deux conditions (côté*temps). En conséquence, nous avons constaté une croissance osseuse statistiquement significative du bassin dans l’intervalle de temps entre le diagnostic de la scoliose et le port du corset (p=0,033). Une asymétrie significative entre les côtés gauche et droit du bassin (p=0,013) a également été constatée. En ce qui concerne les paramètres bidimensionnels, nous avons constaté une augmentation de la version pelvienne (p=0,024) au cours de la croissance des jeunes filles. Finalement, le bassin n'a pas présenté de distorsion, puisqu'une valeur de p de 0,763 a été observée. En conclusion, la croissance des jeunes filles atteintes de la scoliose idiopathique de l'adolescence est accompagnée d'une asymétrie morphologique entre les deux os coxaux du bassin. Cette asymétrie constatée au moment du diagnostic de la scoliose des filles a évolué jusqu'à l’instant où le port du corset a été prescrit. Quant aux paramètres bidimensionnels, nous pouvons conclure que la rotation du bassin vers l'arrière a augmenté au cours de la croissance des jeunes filles, produisant ainsi une rétroversion pelvienne dans le plan sagittal. La distorsion tridimensionnelle du bassin n'a toutefois pas été observée au cours de la croissance des jeunes filles.
Resumo:
A method for the construction of a patient-specific model of a scoliotic torso for surgical planning via inter- patient registration is presented. Magnetic Resonance Images (MRI) of a generic model are registered to surface topography (TP) and X-ray data of a test patient. A partial model is first obtained via thin-plate spline registration between TP and X-ray data of the test patient. The MRIs from the generic model are then fit into the test patient using articulated model registration between the vertebrae of the generic model’s MRIs in prone position and the test patient’s X-rays in standing position. A non-rigid deformation of the soft tissues is performed using a modified thin-plate spline constrained to maintain bone rigidity and to fit in the space between the vertebrae and the surface of the torso. Results show average Dice values of 0.975 ± 0.012 between the MRIs following inter-patient registration and the surface topography of the test patient, which is comparable to the average value of 0.976 ± 0.009 previously obtained following intra-patient registration. The results also show a significant improvement compared to rigid inter-patient registration. Future work includes validating the method on a larger cohort of patients and incorporating soft tissue stiffness constraints. The method developed can be used to obtain a geometric model of a patient including bone structures, soft tissues and the surface of the torso which can be incorporated in a surgical simulator in order to better predict the outcome of scoliosis surgery, even if MRI data cannot be acquired for the patient.