929 resultados para Water Distribution Networks Leak Detection I
Resumo:
Aitchison and Bacon-Shone (1999) considered convex linear combinations of compositions. In other words, they investigated compositions of compositions, where the mixing composition follows a logistic Normal distribution (or a perturbation process) and the compositions being mixed follow a logistic Normal distribution. In this paper, I investigate the extension to situations where the mixing composition varies with a number of dimensions. Examples would be where the mixing proportions vary with time or distance or a combination of the two. Practical situations include a river where the mixing proportions vary along the river, or across a lake and possibly with a time trend. This is illustrated with a dataset similar to that used in the Aitchison and Bacon-Shone paper, which looked at how pollution in a loch depended on the pollution in the three rivers that feed the loch. Here, I explicitly model the variation in the linear combination across the loch, assuming that the mean of the logistic Normal distribution depends on the river flows and relative distance from the source origins
Resumo:
Excessive levels of P in agricultural soils pose a threat to local water quality. This study evaluated (i) time-dependent changes in soil P sorption (expressed as a phosphorus sorption index, PSI) and P availability (as resin P) during incubation (100 d) with poultry litter, cattle slurry, sewage sludge, or KH2PO4, added on a P-equivalent basis (100 mg P kg(-1)), and (ii) the subsequent kinetics of P release, measured by repeated extractions with a mixed cation-anion exchange resin. Soil exchangeable Ca and ammonium oxalate-extractable Fe and Al were also determined at 100 d of incubation. The small decrease in P sorption in the litter and sludge treatments (25%), compared with that in the slurry and KH2PO4 treatments (52%) between 20 and 100 d of incubation was attributed partly to the formation of new adsorption sites for P. Subsequent P release was described by a power equation: Resin P = a(extraction number)(b), where the constants a and b represent resin P obtained with a single extraction and the rate of P release per resin extraction, respectively. On average, the rate of P release decreased in the order: KH2PO4 and slurry > litter > sludge, and was inversely related to exchangeable Ca content of the incubated soils (R-2 = 0.57). The slower rates of P release in the litter and sludge treatments (P < 0.001) are attributed to the large values for exchangeable Ca (1050-2640 and 1070-2710 mg kg(-1), respectively) in these amended soils. Future research concerned with short-term declines in environmentally harmful levels of P in recently amended soils should consider the differential effects of the amendments on soil P dynamics.
Resumo:
Platelet response to activation varies widely between individuals but shows interindividual consistency and strong heritability. The genetic basis of this variation has not been properly explored. We therefore systematically measured the effect on function of sequence variation in 97 candidate genes in the collagen and adenosine-diphosphate (ADP) signaling pathways. Resequencing of the genes in 48 European DNA samples nearly doubled the number of known single nucleotide polymorphisms (SNPs) and informed the selection of 1327 SNPs for genotyping in 500 healthy Northern European subjects with known platelet responses to collagen-related peptide (CRP-XL) and ADP. This identified 17 novel associations with platelet function (P < .005) accounting for approximately 46% of the variation in response. Further investigations with platelets of known genotype explored the mechanisms behind some of the associations. SNPs in PEAR1 associated with increased platelet response to CRP-XL and increased PEAR1 protein expression after platelet degranulation. The minor allele of a 3' untranslated region (UTR) SNP (rs2769668) in VAV3 was associated with higher protein expression (P = .03) and increased P-selectin exposure after ADP activation (P = .004). Furthermore the minor allele of the intronic SNP rs17786144 in ITPR1 modified Ca2+ levels after activation with ADP (P < .004). These data provide novel insights into key hubs within platelet signaling networks.
Resumo:
Water table draw-down is thought to increase peat decomposition and, therefore, DOC release. However, several studies have shown lower DOC concentrations during droughts relative to ‘normal’ periods with high water table. We carried out controlled incubation experiments at 10°C on 10x10 cm peat soil cores collected from six UK sites across a sulphur deposition gradient. Our aim was to quantify the balance between microbial consumption and chemical precipitation of DOC due to episodic acidification driven by sulphur redox reactions by comparing changes in soil water chemistry to microbial activity (i.e. soil respiration and trace gas fluxes). During dry periods, all sites showed a concurrent increase in SO4 and soil respiration and a decline in DOC. However, the magnitude of change in both DOC and SO4 varied considerably between sites according to historical sulphur deposition loads and the variation in acid/base chemistry.
Resumo:
It has been known for decades that the metabolic rate of animals scales with body mass with an exponent that is almost always <1, >2/3, and often very close to 3/4. The 3/4 exponent emerges naturally from two models of resource distribution networks, radial explosion and hierarchically branched, which incorporate a minimum of specific details. Both models show that the exponent is 2/3 if velocity of flow remains constant, but can attain a maximum value of 3/4 if velocity scales with its maximum exponent, 1/12. Quarterpower scaling can arise even when there is no underlying fractality. The canonical “fourth dimension” in biological scaling relations can result from matching the velocity of flow through the network to the linear dimension of the terminal “service volume” where resources are consumed. These models have broad applicability for the optimal design of biological and engineered systems where energy, materials, or information are distributed from a single source.
Resumo:
We present simultaneous multicolor infrared and optical photometry of the black hole X-ray transient XTE J1118+480 during its short 2005 January outburst, supported by simultaneous X-ray observations. The variability is dominated by short timescales, ~10 s, although a weak superhump also appears to be present in the optical. The optical rapid variations, at least, are well correlated with those in X-rays. Infrared JHKs photometry, as in the previous outburst, exhibits especially large-amplitude variability. The spectral energy distribution (SED) of the variable infrared component can be fitted with a power law of slope α=-0.78+/-0.07, where F_ν~ν^α. There is no compelling evidence for evolution in the slope over five nights, during which time the source brightness decayed along almost the same track as seen in variations within the nights. We conclude that both short-term variability and longer timescale fading are dominated by a single component of constant spectral shape. We cannot fit the SED of the IR variability with a credible thermal component, either optically thick or thin. This IR SED is, however, approximately consistent with optically thin synchrotron emission from a jet. These observations therefore provide indirect evidence to support jet-dominated models for XTE J1118+480 and also provide a direct measurement of the slope of the optically thin emission, which is impossible, based on the average spectral energy distribution alone.
Resumo:
The Distribution Network Operators (DNOs) role is becoming more difficult as electric vehicles and electric heating penetrate the network, increasing the demand. As a result it becomes harder for the distribution networks infrastructure to remain within its operating constraints. Energy storage is a potential alternative to conventional network reinforcement such as upgrading cables and transformers. The research presented here in this paper shows that due to the volatile nature of the LV network, the control approach used for energy storage has a significant impact on performance. This paper presents and compares control methodologies for energy storage where the objective is to get the greatest possible peak demand reduction across the day from a pre-specified storage device. The results presented show the benefits and detriments of specific types of control on a storage device connected to a single phase of an LV network, using aggregated demand profiles based on real smart meter data from individual homes. The research demonstrates an important relationship between how predictable an aggregation is and the best control methodology required to achieve the objective.
Resumo:
The international appeal of Hollywood films through the twentieth century has been a subject of interest to economic and film historians alike. This paper employs some of the methods of the economic historian to evaluate key arguments within the film history literature explaining the global success of American films. Through careful analysis of both existing and newly constructed data sets, the paper examines the extent to which Hollywood's foreign earnings were affected by: film production costs; the extent of global distribution networks; and also the international orientation of the films themselves. The paper finds that these factors influenced foreign earnings in quite distinct ways, and that their relative importance changed over time. The evidence presented here suggests a degree of interaction between the production and distribution arms of the major US film companies in their pursuit of foreign markets that would benefit from further archival-based investigation.
Resumo:
A partir dos objetivos propostos pelas políticas nacionais de saúde, ambientais e de saneamento básico buscou-se analisar os efeitos da cobrança pelo uso da água no setor de saneamento básico, visando identificar possíveis variações causadas por este instrumento econômico no acesso à água, na qualidade do produto ofertado e na qualidade do serviço prestado. Ainda, por se tratar de um serviço público, analisamos a performance técnica das empresas paulistas do setor de saneamento básico na prestação deste serviço por meio da metodologia Data Envelopment Analysis. Esta ferramenta resulta em um indicador de desempenho, com base na melhor relação input/output, ao estabelecer um ranking de eficiência médio a partir das práticas mais eficientes de cada unidade produtiva.
Resumo:
The study aimed to evaluate the radial profile and the uniformity of water distribution of sprinkler manufactured by the company NaanDanJain, model 427 1/2 '' M and nozzle with 2.8 mm of internal diameter, operating at pressures of 150, 200, 300 and 400 kPa and five positions of the deflector (0, 20, 50, 80 and 100%). For the determination of the parameters evaluated, the grid method was used and with the help of computer application CATCH 3D, overlapping layers of water depths was calculated with ten spacing. The results show that the deflector adjustment influences the radius of wetness and the distribution profile while the uniformity of water application showed as an important mechanism, since it permits different behavior for the sprinkler, ensuring wide track of utilization of the equipment.
Resumo:
Em solos tropicais, a distribuição dos nutrientes no solo em função da fertirrigação realizada por meio de irrigação localizada (gotejamento e/ou microaspersão), na cultura de citros, é pouco conhecida. Este trabalho teve por objetivo avaliar os padrões de distribuição de potássio, cálcio, magnésio e fósforo em solo tropical, em função da fertirrigação, aplicada por dois sistemas de irrigação localizada (microaspersão e gotejamento), sendo que o sistema por gotejamento era composto por uma e duas linhas laterais por linha de plantas, e o de microaspersão por apenas uma linha, e com três dotações hídricas (100%, 75% e 50%) da evapotranspiração da cultura (ETc), em um pomar de laranjeira. As fontes de fertilizantes utilizadas na fertirrigação foram o nitrato de amônio (fonte de N), o cloreto de potássio (fonte de K+) e o ácido fosfórico (fonte de P). Observouse que, sob o emissor, nos tratamentos com gotejamento, houve depleção nos teores de Ca++ e Mg++ desde a superfície do solo até 60 cm de profundidade em relação aos teores anteriores às fertirrigações, enquanto os teores de P aumentaram, principalmente na camada de 0 cm a 20 cm. Na microaspersão, esses efeitos não foram observados, ocorrendo distribuição mais homogênea desses nutrientes tanto na direção transversal à linha de plantas quanto em profundidade. As lâminas de irrigação aplicadas por irrigação localizada não interferem na distribuição de K+ aplicado por fertirrigação e do Ca++ e Mg++ no solo em profundidade, porém menores lâminas de irrigação promovem maior concentração de P na camada mais superficial do solo, e lâminas maiores carregam o P para camadas mais profundas.
Resumo:
Most algorithms for state estimation based on the classical model are just adequate for use in transmission networks. Few algorithms were developed specifically for distribution systems, probably because of the little amount of data available in real time. Most overhead feeders possess just current and voltage measurements at the middle voltage bus-bar at the substation. In this way, classical algorithms are of difficult implementation, even considering off-line acquired data as pseudo-measurements. However, the necessity of automating the operation of distribution networks, mainly in regard to the selectivity of protection systems, as well to implement possibilities of load transfer maneuvers, is changing the network planning policy. In this way, some equipments incorporating telemetry and command modules have been installed in order to improve operational features, and so increasing the amount of measurement data available in real-time in the System Operation Center (SOC). This encourages the development of a state estimator model, involving real-time information and pseudo-measurements of loads, that are built from typical power factors and utilization factors (demand factors) of distribution transformers. This work reports about the development of a new state estimation method, specific for radial distribution systems. The main algorithm of the method is based on the power summation load flow. The estimation is carried out piecewise, section by section of the feeder, going from the substation to the terminal nodes. For each section, a measurement model is built, resulting in a nonlinear overdetermined equations set, whose solution is achieved by the Gaussian normal equation. The estimated variables of a section are used as pseudo-measurements for the next section. In general, a measurement set for a generic section consists of pseudo-measurements of power flows and nodal voltages obtained from the previous section or measurements in real-time, if they exist -, besides pseudomeasurements of injected powers for the power summations, whose functions are the load flow equations, assuming that the network can be represented by its single-phase equivalent. The great advantage of the algorithm is its simplicity and low computational effort. Moreover, the algorithm is very efficient, in regard to the accuracy of the estimated values. Besides the power summation state estimator, this work shows how other algorithms could be adapted to provide state estimation of middle voltage substations and networks, namely Schweppes method and an algorithm based on current proportionality, that is usually adopted for network planning tasks. Both estimators were implemented not only as alternatives for the proposed method, but also looking for getting results that give support for its validation. Once in most cases no power measurement is performed at beginning of the feeder and this is required for implementing the power summation estimations method, a new algorithm for estimating the network variables at the middle voltage bus-bar was also developed
Resumo:
The reconfiguration of a distribution network is a change in its topology, aiming to provide specific operation conditions of the network, by changing the status of its switches. It can be performed regardless of any system anomaly. The service restoration is a particular case of reconfiguration and should be performed whenever there is a network failure or whenever one or more sections of a feeder have been taken out of service for maintenance. In such cases, loads that are supplied through lines sections that are downstream of portions removed for maintenance may be supplied by the closing of switches to the others feeders. By classical methods of reconfiguration, several switches may be required beyond those used to perform the restoration service. This includes switching feeders in the same substation or for substations that do not have any direct connection to the faulted feeder. These operations can cause discomfort, losses and dissatisfaction among consumers, as well as a negative reputation for the energy company. The purpose of this thesis is to develop a heuristic for reconfiguration of a distribution network, upon the occurrence of a failure in this network, making the switching only for feeders directly involved in this specific failed segment, considering that the switching applied is related exclusively to the isolation of failed sections and bars, as well as to supply electricity to the islands generated by the condition, with significant reduction in the number of applications of load flows, due to the use of sensitivity parameters for determining voltages and currents estimated on bars and lines of the feeders directly involved with that failed segment. A comparison between this process and classical methods is performed for different test networks from the literature about networks reconfiguration
Resumo:
The pumping of fluids in pipelines is the most economic and safe form of transporting fluids. That explains why in Europe there was in 1999 about 30.000 Km [7] of pipelines of several diameters, transporting millíons of cubic meters of crude oil end refined products, belonging to COCAWE (assaciation of companies of petroleum of Europe for health, environment and safety, that joint several petroleum companies). In Brazil they are about 18.000 Km of pipelines transporting millions of cubic meters of liquids and gases. In 1999, nine accidents were registered to COCAWE. Among those accidents one brought a fatal victim. The oil loss was of 171 m3, equivalent to O,2 parts per million of the total of the transported volume. Same considering the facts mentioned the costs involved in ao accident can be high. An accident of great proportions can bríng loss of human lives, severe environmental darnages, loss of drained product, loss . for dismissed profit and damages to the image of the company high recovery cost. In consonance with that and in some cases for legal demands, the companies are, more and more, investing in systems of Leak detection in pipelines based on computer algorithm that operate in real time, seeking wíth that to minimize still more the drained volumes. This decreases the impacts at the environment and the costs. In general way, all the systems based on softWare present some type of false alarm. In general a commitment exists betWeen the sensibílity of the system and the number of false alarms. This work has as objective make a review of thé existent methods and to concentrate in the analysis of a specific system, that is, the system based on hydraulic noise, Pressure Point Analyzis (PPA). We will show which are the most important aspects that must be considered in the implementation of a Leak Detection System (LDS), from the initial phase of the analysis of risks passing by the project bases, design, choice of the necessary field instrumentation to several LDS, implementation and tests. We Will make na analysis of events (noises) originating from the flow system that can be generator of false alarms and we will present a computer algorithm that restricts those noises automatically
Resumo:
The aim of this study is to characterize and evaluate the Macro System of Regional Water Distribution Natal North (RNN) and Southern Regional Natal (RNS), covering 35% and 65% respectively of the Natal-RN City. The terms of the quality and quantity of water (surface and groundwater) were also evaluated in order to adjust the parameters that contribute to proper distribution and control in water reserves. The methodology of the work took place from collecting volumetric data of production capacity and distribution of the two treatment plants for Regional as well as the flow rates of wells. Yet the quantitative capacity of reservation, distribution and consumption of the main reservoirs, population numbers and consumption of members neighborhoods were collected. Data were tabulated and used in computational simulator EPANET to diagnose possible through the water balance, the offers and demands on the water supply system in the neighborhoods of the capital, linking them to specific distribution points. We also evaluated the wells in the levels of nitrate in water consumed. As a result it was found that some neighborhoods in the South Regional Natal, was ranked as critical supply situation: City of Hope, Lagoa Nova and Nova Descoberta, where demand exceeds supply. While in most Northern Regional Natal present deficiency in the supply system as: Lagoa Azul, the Parque dos Coqueiros, igapó, Amarante and Salinas. The rates of nitrate in the city were significant, but manageable with corrective and preventive measures. The averages were 12 mg /l-N in Candelária, 10 mg/l-N in Lagoa Nova, 9 mg/l-N in Satelite, 20 mg/l-N in Gramore and 15 mg/l-N in N. Sra. Apresentação. Therefore proper distribution of water abstracted and implementation of quality control ensures the supply required by the system, associated with preservation of Water Resources of the Metropolitan Region of Natal