959 resultados para Voltage reference circuits
Resumo:
Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured weighted computed tomography dose index (CTDI) to the nominal weighted CTDI as displayed on the workstation. Patient doses were corrected by this factor providing a realistic basis for establishing national DRLs. Results showed large variations in doses between different radiology departments in Switzerland, especially for examinations of the petrous bone, pelvis, lower limbs and heart. This indicates that the concept of DRLs has not yet been correctly applied for CT examinations in clinical routine. A close collaboration of all stakeholders is mandatory to assure an effective radiation protection of patients. On-site audits will be intensified to further establish the concept of DRLs in Switzerland.
Resumo:
Background: Urine is still the matrix of choice to fight against doping, because it can be collected non-invasively during anti-doping tests. Most of the World Anti-Doping Agency's accredited laboratories have more than 20 years experience in analyzing this biological fluid and the majority of the compounds listed in the 2010 Prohibited List - International Standard are eliminated through the urinary apparatus. Storing and transporting urine samples for doping analyses does not include a specific protocol to prevent microbial and thermal degradation. The use of a rapid and reliable screening method could enable determine reference intervals for urine specimens in doping control samples and evaluate notably the prevalence of microbial contamination known to be responsible for the degradation of chemical substances in urine.Methods: The Sysmex(R) UF-500i is a recent urine flow cytometer analyzer capable of quantifying BACT and other urinary particles such as RBC, WBC, EC, DEBRIS, CAST, PATH. CAST, YLC, SRC as well as measuring urine conductivity. To determine urine anti-doping reference intervals, 501 samples received in our laboratory over a period of two months were submitted to an immediate examination. All samples were collected and then transported at room temperature. Analysis of variance was performed to test the effects of factors such as gender, test type [in-competition, out-of-competition] and delivery time.Results: The data obtained showed that most of the urine samples were highly contaminated with bacteria. The other urine particles were also very different according to the factors.Conclusions: The Sysmex(R) UF-500i was capable of providing a snapshot of urine particles present in the samples at the time of the delivery to the laboratory. These particles, BACT in particular, gave a good idea of the possible microbial degradation which had and/or could have occurred in the sample. This information could be used as the first quality control set up in WADA (World Anti-Doping Agency) accredited laboratories to determine if steroid profiles, endogenous and prohibited substances have possibly been altered. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Electrical deep brain stimulation (DBS) is an efficient method to treat movement disorders. Many models of DBS, based mostly on finite elements, have recently been proposed to better understand the interaction between the electrical stimulation and the brain tissues. In monopolar DBS, clinically widely used, the implanted pulse generator (IPG) is used as reference electrode (RE). In this paper, the influence of the RE model of monopolar DBS is investigated. For that purpose, a finite element model of the full electric loop including the head, the neck and the superior chest is used. Head, neck and superior chest are made of simple structures such as parallelepipeds and cylinders. The tissues surrounding the electrode are accurately modelled from data provided by the diffusion tensor magnetic resonance imaging (DT-MRI). Three different configurations of RE are compared with a commonly used model of reduced size. The electrical impedance seen by the DBS system and the potential distribution are computed for each model. Moreover, axons are modelled to compute the area of tissue activated by stimulation. Results show that these indicators are influenced by the surface and position of the RE. The use of a RE model corresponding to the implanted device rather than the usually simplified model leads to an increase of the system impedance (+48%) and a reduction of the area of activated tissue (-15%).
Resumo:
Correspondència referida a l'article de R. Giannetti, publicat ibid. vol.49 p.87-88
Resumo:
Voltage fluctuations caused by parasitic impedances in the power supply rails of modern ICs are a major concern in nowadays ICs. The voltage fluctuations are spread out to the diverse nodes of the internal sections causing two effects: a degradation of performances mainly impacting gate delays anda noisy contamination of the quiescent levels of the logic that drives the node. Both effects are presented together, in thispaper, showing than both are a cause of errors in modern and future digital circuits. The paper groups both error mechanismsand shows how the global error rate is related with the voltage deviation and the period of the clock of the digital system.
Resumo:
A general criterion for the design of adaptive systemsin digital communications called the statistical reference criterionis proposed. The criterion is based on imposition of the probabilitydensity function of the signal of interest at the outputof the adaptive system, with its application to the scenario ofhighly powerful interferers being the main focus of this paper.The knowledge of the pdf of the wanted signal is used as adiscriminator between signals so that interferers with differingdistributions are rejected by the algorithm. Its performance isstudied over a range of scenarios. Equations for gradient-basedcoefficient updates are derived, and the relationship with otherexisting algorithms like the minimum variance and the Wienercriterion are examined.
Resumo:
BACKGROUND: The GENCODE consortium was formed to identify and map all protein-coding genes within the ENCODE regions. This was achieved by a combination of initial manual annotation by the HAVANA team, experimental validation by the GENCODE consortium and a refinement of the annotation based on these experimental results. RESULTS: The GENCODE gene features are divided into eight different categories of which only the first two (known and novel coding sequence) are confidently predicted to be protein-coding genes. 5' rapid amplification of cDNA ends (RACE) and RT-PCR were used to experimentally verify the initial annotation. Of the 420 coding loci tested, 229 RACE products have been sequenced. They supported 5' extensions of 30 loci and new splice variants in 50 loci. In addition, 46 loci without evidence for a coding sequence were validated, consisting of 31 novel and 15 putative transcripts. We assessed the comprehensiveness of the GENCODE annotation by attempting to validate all the predicted exon boundaries outside the GENCODE annotation. Out of 1,215 tested in a subset of the ENCODE regions, 14 novel exon pairs were validated, only two of them in intergenic regions. CONCLUSION: In total, 487 loci, of which 434 are coding, have been annotated as part of the GENCODE reference set available from the UCSC browser. Comparison of GENCODE annotation with RefSeq and ENSEMBL show only 40% of GENCODE exons are contained within the two sets, which is a reflection of the high number of alternative splice forms with unique exons annotated. Over 50% of coding loci have been experimentally verified by 5' RACE for EGASP and the GENCODE collaboration is continuing to refine its annotation of 1% human genome with the aid of experimental validation.
Resumo:
Line converters have become an attractive AC/DC power conversion solution in industrial applications. Line converters are based on controllable semiconductor switches, typically insulated gate bipolar transistors. Compared to the traditional diode bridge-based power converters line converters have many advantageous characteristics, including bidirectional power flow, controllable de-link voltage and power factor and sinusoidal line current. This thesis considers the control of the lineconverter and its application to power quality improving. The line converter control system studied is based on the virtual flux linkage orientation and the direct torque control (DTC) principle. A new DTC-based current control scheme is introduced and analyzed. The overmodulation characteristics of the DTC converter are considered and an analytical equation for the maximum modulation index is derived. The integration of the active filtering features to the line converter isconsidered. Three different active filtering methods are implemented. A frequency-domain method, which is based on selective harmonic sequence elimination, anda time-domain method, which is effective in a wider frequency band, are used inharmonic current compensation. Also, a voltage feedback active filtering method, which mitigates harmonic sequences of the grid voltage, is implemented. The frequency-domain and the voltage feedback active filtering control systems are analyzed and controllers are designed. The designs are verified with practical measurements. The performance and the characteristics of the implemented active filtering methods are compared and the effect of the L- and the LCL-type line filteris discussed. The importance of the correct grid impedance estimate in the voltage feedback active filter control system is discussed and a new measurement-based method to obtain it is proposed. Also, a power conditioning system (PCS) application of the line converter is considered. A new method for correcting the voltage unbalance of the PCS-fed island network is proposed and experimentally validated.
Resumo:
Carnitine-free total parenteral nutrition (TPN) is claimed to result in a carnitine deficiency with subsequent impairment of fat oxidation. The present study was designed to evaluate the possible benefit of carnitine supplementation on postoperative fat and nitrogen utilization. Sixteen patients undergoing total esophagectomy were evenly randomized and received TPN without or with L-carnitine supplementation (74 mumol.kg-1.d-1) during 11 postoperative days. On day 11, a 4-h infusion of L-carnitine (125 mumol/kg) was performed in both groups. The effect of supplementation was evaluated by indirect calorimetry, N balance, and repeated measurements of plasma lipids and ketone bodies. Irrespective of continuous or acute supplementation, respiratory quotient and fat oxidation were similarly maintained throughout the study in both groups whereas N balance appeared to be more favorable without carnitine. We conclude that carnitine-supplemented TPN does not improve fat oxidation or promote N utilization in the postoperative phase.
Resumo:
Työn tavoitteena oli tutkia hyvän asiakasreferenssin ominaisuuksia suodatinvalmistaja Laroxin myynnin ja huollon sekä yrityksen asiakkaiden näkökulmasta. Larox voi käyttää saatua tietoa referenssien tehokkaampaan valintaan ja hyödyntämiseen. Kaksi internet-kyselyä toteutettiin, välineenä Webropol. Alustava kysely sunnattiin Laroxin myynnille ja huollolle. Kysely koostui viidestä kategoriasta asiakasreferenssejä, joiden tärkeyttä arvioitiin, sekä vapaista vastauksista. Tunnistettuja hyvän asiakasreferenssin ominaisuuksia ovat hyvä suhde referenssiasiakkaaseen, positiiviset jarehelliset suosittelut asiakkaalta, referenssilaitteen hyvä toimintakyky ja asiakas joka ymmärtää huollon tärkeyden. Pääkysely suunnattiin Laroxin asiakkaille. Tilastollisilla analyyseilla tutkittiin koetun riskin mallinmuuttujien välisiä yhteyksiä. Analyysit eivät paljastaneet merkittäviä riippuvuuksia asiakasreferenssin ominaisuuksien tärkeydessä eritaustaisten vastaajien tai tilannetekijöiden välillä, mutta asiakasreferenssin ominaisuuksien faktorit tukevat mallia. Referenssilaitteiden toimintakyky vaikuttaa tärkeimmältä ja huollon tärkeys on myös merkittävä.
Resumo:
Hilalta ohjattavien tehokytkimien, kuten IGBT tai MOSFET, ohjaaminen toteutetaan ohjausjännitettä muuttamalla. Hilaohjaimen tehtävä on ladata tehokytkimen hilakapasitanssia ohjattuun jännitteeseen. Hilaohjaimen siirtämän varauksen suuruuteen vaikuttaa hilakapasitanssin todellinen suuruus ja käytettävä ohjausjännite. Hilaohjaimen virrankäsittelykyky määrittää hilaohjaimen nopeuden siinä mielessä, että ohjattavan komponentin hilavaraus tulisi pystyä lataamaan ja purkamaan tietyssä suhteessa kytkentätaajuuteen. Kytkentätaajuuksien kasvaessa myös hilaohjaimen virrankäsittelykyky sekä hilaohjaimen teho joutuvat uudelleen arvioitaviksi. Työssä perehdytään IGBT:n toimintaan ja hilaohjainratkaisuihin suurilla kytkentätaajuuksilla. Työssä ontutkittu mahdollisuutta rakentaa IGBT:n hilaohjain jo markkinoilla olevista MOSFET:ien hilaohjaimista. Suurnopeushilaohjaimesta suunnitellaanja rakennetaan prototyyppi. Prototyypin suoriutumista tehtävistään tarkastellaan tekemällä mittauksia. Lopuksi arvioidaan asioita joiden tulee muuttua matkalla kohti megahertsien kytkentätaajuuksia.
Resumo:
Verkkovaihtosuuntaajalla pystytään muuntamaan tasajännite vaihtojännitteeksi ja päinvastoin. Verkkovaihtosuuntaajan toiminta perustuu tehokytkinten ohjaukseen ja sopivan modulointimenetelmän käyttöön. Vektorisäädössä vaihtosuuntaajanvirrat ja jännitteet esitetään kompleksitasossa, jolloin virta- ja jännitekomponentit voidaan esittää vektoreina. Vektorisäädössä verkkovaihtosuuntaajan ohjaustoteutetaan laskemalla kompleksitasossa vektoreille arvot, jotka tuottavat vaihtosuuntaajan lähtöön halutun vektorin. Koska FPGA-piirit mahdollistavat nopean rinnakkaisen laskennan, soveltuvat ne hyvin vektorisäädön toteuttamiseen. FPGA-piirien rakenteesta johtuen on säätöjärjestelmän suunnittelussa huomioitava kiinteän pilkun lukujen riittävä bittileveys ja järjestelmän diskretointiaika. Työssä suunnitellaan verkkovaihtosuuntaajan vektorisäätö ja tutkitaan bittileveyden vaikutusta säädön toteuttamiseen FPGA-piirillä. Bittileveyden tarkasteluun esitetään käytettäväksi tilastollisia menetelmiä. Työssä tarkastellaan kiinteän pilkun järjestelmän ja liukulukujärjestelmän erosuureen tilastollisia tunnusmerkkejä sekä histogrammia. Tarkasteluissa huomattiin, että maksimivirhe itsessään ei tarjoa riittävästi tietoa erosuureen jakautumisesta. Näin ollen maksimivirhe ei ole kaikissa tilanteissa sovelias menetelmä riittävän bittitarkkuuden määrittämiseen. Työssä esitetään riittävän bittitarkkuuden määrittelemiseen käytettäväksi otossuureista otosvarianssia, keskipoikkeamaa ja vaihteluväliä.
Resumo:
Laboratory values of the most commonly assayed clinical chemistry variables were determined in selected elderly and healthy ambulatory populations. The upper and lower limits (2.5 and 97.5 fractiles) were compared with the adult reference values in use in university hospitals of Switzerland. The results suggest that conventional adult reference values can be used for most variables in the elderly and that these values are also useful in an ambulatory population.