990 resultados para Violação de CP (Física nuclear)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducción: La medición de la concentración de hierro hepática (CHH) por RM es una técnica no invasiva de gran utilidad en el diagnóstico de los pacientes con sospecha de sobrecarga férrica en hígado. Objetivo:Validar la eficacia de la RM 1 Tesla en la determinación de la (CHH) en pacientes con sospecha de sobrecarga férrica. Validar su capacidad para diagnosticar o descartar la presencia de una CHH sugestiva de hemocromatosis. Pacientes y métodos:Estudio observacional, transversal, con inclusión prospectiva de pacientes consecutivos. De 2002 a 2010 hemos obtenido la CHH estimada mediante RM 1 Tesla (método Gandon) y de RM 1,5 Tesla (método Alústiza), y mediante BH, en 56 pacientes consecutivos (58RM:35/23). Resultados:Grupo RM 1 Tesla: de acuerdo con CHH en BH, 15 pacientes clasificados como normales (<36µmol/g)-la RM valoró correctamente 7; sobreestimó 8-; 15 grupo hemosiderosis (36-80 µmol/g)-RM valoró correctamente 5, sobreestimó 10-; 5 grupo hemocromatosis (>80 µmol/g)-valoró correctamente las 5-. Existió una correlación entre la determinación de la CHH por BH y RM 1 Tesla con r=0.619. Existieron diferencias estadísticamente significativas (p<0.05) entre CHH media por biopsia (53.43/DE45.67/IC95%37.74 a 69.12) y por RM 1 Tesla (76.14/DE47.31/IC95% 60.46 a 92.97), con sobrevaloración por parte de la RM. Grupo RM 1,5 Tesla: de acuerdo con CHH en BH, normal en 14, hemosiderosis en 6 y hemocromatosis en 3. La RM valoró correctamente 6 y sobreestimó 8 en grupo normal; grupo hemosiderosis, 3 correctamente, 3 sobrevalorados; grupo hemocromatosis, valoró correctamente los 3. La correlación entre CHH por BH y RM 1,5 Tesla fue de r=0.815. La CHH media obtenida por BH (69,34/DE152.1/IC95% 3.57 a 135.1 ) y RM 1,5 Tesla (70.43/DE 57.63/IC95% 45.51 a 95.36) no demostraron diferencias significativas (p>0.05). Conclusiones: La determinación de CHH por RM 1 Tesla (método Gandon) es útil para diagnosticar o descartar hemocromatosis y para diagnosticar CHH normal. Existe una importante tendencia a la sobreestimación en pacientes sin y con sobrecarga férrica en la CHH obtenida por RM 1 Tesla. La determinación de CHH por RM 1,5 Tesla (método Alústiza) es superior a la de RM 1 Tesla, aunque también existe una tendencia a sobreestimar. La CHH media obtenida por BH o RM 1,5 Tesla no tuvieron diferencias significativas. En cambio si existieron entre BH y RM 1 Tesla.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En la sociedad actual, el ejercicio físico se considera un factor determinante para la consecución de una vida saludable. Gracias a los avances tecnológicos y la constante evolución del conocimiento de la actividad física y sus beneficios, la sociedad, en general, goza de numerosas facilidades a la hora de poder realizar cualquier actividad física que genere una mejoría para uno mismo. Pero, a pesar de ello, hay rincones de la sociedad a los que los beneficios del ejercicio no han llegado aún . En el siguiente proyecto estudiaré, por una parte, e lrégimen de aislamiento de los centros penitenciarios; a su vez, profundizaré en los perjuicios que puedan sufrir los internos en este régimen, y en los beneficios que pueda tener el ejercicio físico en los reclusos que sufren el aislamiento. Por último, propondré un programa de ejercicio, que a su vez pueda compenetrarse con el reglamento penitenciario, buscando los beneficios del ejercicio para las personas que se encuentren en esta situación.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breve descripción de la artritis reumatoide, etiología, causas y sintomas mas comunes. Tras ello, se realiza una revisión bibliográfica sobre el impacto de la actividad fisica en personas adultas con esta patología y que ejercicios son susceptibles de realizarse con el objetivo de determinar que practicas son las más efectivas para mejorar su estado de salud, además de detectar los efectos negativos que estas pueden tener. Posteriormete se establecen unas conclusiones que nos permitirán diseñar un correcto plan de ejercicio fisico totalmente seguro para mejorar la salud de las personas adultas con artritis reumatoide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hartree-Fock (HF) calculations have had remarkable success in describing large nuclei at high spin, temperature and deformation. To allow full range of possible deformations, the Skyrme HF equations can be discretized on a three-dimensional mesh. However, such calculations are currently limited by the computational resources provided by traditional supercomputers. To take advantage of recent developments in massively parallel computing technology, we have implemented the LLNL Skyrme-force static and rotational HF codes on Intel's DELTA and GAMMA systems at Caltech.

We decomposed the HF code by assigning a portion of the mesh to each node, with nearest neighbor meshes assigned to nodes connected by communication· channels. This kind of decomposition is well-suited for the DELTA and the GAMMA architecture because the only non-local operations are wave function orthogonalization and the boundary conditions of the Poisson equation for the Coulomb field.

Our first application of the HF code on parallel computers has been the study of identical superdeformed (SD) rotational bands in the Hg region. In the last ten years, many SD rotational bands have been found experimentally. One very surprising feature found in these SD rotational bands is that many pairs of bands in nuclei that differ by one or two mass units have nearly identical deexcitation gamma-ray energies. Our calculations of the five rotational bands in ^(192)Hg and ^(194)Pb show that the filling of specific orbitals can lead to bands with deexcitation gamma-ray energies differing by at most 2 keV in nuclei differing by two mass units and over a range of angular momenta comparable to that observed experimentally. Our calculations of SD rotational bands in the Dy region also show that twinning can be achieved by filling or emptying some specific orbitals.

The interpretation of future precise experiments on atomic parity nonconservation (PNC) in terms of parameters of the Standard Model could be hampered by uncertainties in the atomic and nuclear structure. As a further application of the massively parallel HF calculations, we calculated the proton and neutron densities of the Cesium isotopes from A = 125 to A = 139. Based on our good agreement with experimental charge radii, binding energies, and ground state spins, we conclude that the uncertainties in the ratios of weak charges are less than 10^(-3), comfortably smaller than the anticipated experimental error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Part I of this thesis, a new magnetic spectrometer experiment which measured the β spectrum of ^(35)S is described. New limits on heavy neutrino emission in nuclear β decay were set, for a heavy neutrino mass range between 12 and 22 keV. In particular, this measurement rejects the hypothesis that a 17 keV neutrino is emitted, with sin^2 θ = 0.0085, at the 6δ statistical level. In addition, an auxiliary experiment was performed, in which an artificial kink was induced in the β spectrum by means of an absorber foil which masked a fraction of the source area. In this measurement, the sensitivity of the magnetic spectrometer to the spectral features of heavy neutrino emission was demonstrated.

In Part II, a measurement of the neutron spallation yield and multiplicity by the Cosmic-ray Underground Background Experiment is described. The production of fast neutrons by muons was investigated at an underground depth of 20 meters water equivalent, with a 200 liter detector filled with 0.09% Gd-loaded liquid scintillator. We measured a neutron production yield of (3.4 ± 0.7) x 10^(-5) neutrons per muon-g/cm^2, in agreement with other experiments. A single-to-double neutron multiplicity ratio of 4:1 was observed. In addition, stopped π^+ decays to µ^+ and then e^+ were observed as was the associated production of pions and neutrons, by the muon spallation interaction. It was seen that practically all of the π^+ produced by muons were also accompanied by at least one neutron. These measurements serve as the basis for neutron background estimates for the San Onofre neutrino detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We perform a measurement of direct CP violation in b to s+gamma Acp, and the measurement of a difference between Acp for neutral B and charged B mesons, Delta A_{X_s\gamma}, using 429 inverse femtobarn of data recorded at the Upsilon(4S) resonance with the BABAR detector. B mesons are reconstructed from 16 exclusive final states. Particle identification is done using an algorithm based on Error Correcting Output Code with an exhaustive matrix. Background rejection and best candidate selection are done using two decision tree-based classifiers. We found $\acp = 1.73%+-1.93%+-1.02% and Delta A_X_sgamma = 4.97%+-3.90%+-1.45% where the uncertainties are statistical and systematic respectively. Based on the measured value of Delta A_X_sgamma, we determine a 90% confidence interval for Im C_8g/C_7gamma, where C_7gamma and C_8g are Wilson coefficients for New Physics amplitudes, at -1.64 < Im C_8g/C_7gamma < 6.52.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The roles of the folate receptor and an anion carrier in the uptake of 5- methyltetrahydrofolate (5-MeH_4folate) were studied in cultured human (KB) cells using radioactive 5-MeH_4folate. Binding of the 5-MeH_4folate was inhibited by folic acid, but not by probenecid, an anion carrier inhibitor. The internalization of 5-MeH_4folate was inhibited by low temperature, folic acid, probenecid and methotrexate. Prolonged incubation of cells in the presence of high concentrations of probenecid appeared to inhibit endocytosis of folatereceptors as well as the anion carrier. The V_(max) and K_M values for the carrier were 8.65 ± 0.55 pmol/min/mg cell protein and 3.74 ± 0.54µM, respectively. The transport of 5-MeH4folate was competitively inhibited by folic acid, probenecid and methotrexate. The carrier dissociation constants for folic acid, probenecid and methotreate were 641 µM, 2.23 mM and 13.8 µM, respectively. Kinetic analysis suggests that 5-MeH_4folate at physiological concentration is transported through an anion carrier with the characteristics of the reduced-folate carrier after 5-MeH_4folate is endocytosed by folate receptors in KB cells. Our data with KB cells suggest that folate receptors and probenecid-sensitive carriers work in tandem to transport 5-MeH_4folate to the cytoplasm of cells, based upon the assumption that 1 mM probenecid does not interfere with the acidification of the vesicle where the folate receptors are endocytosed.

Oligodeoxynucleotides designed to hybridize to specific mRNA sequences (antisense oligonucleotides) or double stranded DNA sequences have been used to inhibit the synthesis of a number of cellular and viral proteins (Crooke, S. T. (1993) FASEB J. 7, 533-539; Carter, G. and Lemoine, N. R. (1993) Br. J. Cacer 67, 869-876; Stein, C. A. and cohen, J. S. (1988) Cancer Res. 48, 2659-2668). However, the distribution of the delivered oligonucleotides in the cell, i.e., in the cytoplasm or in the nucleus has not been clearly defined. We studied the kinetics of oligonucleotide transport into the cell nucleus using reconstituted cell nuclei as a model system. We present evidences here that oligonucleotides can freely diffuse into reconstituted nuclei. Our results are consistent with the reports by Leonetti et al. (Proc. Natl. Acad. Sci. USA, Vol. 88, pp. 2702-2706, April 1991), which were published while we were carrying this research independently. We also investigated whether a synthetic nuclear localization signal (NLS) peptide of SV40 T antigen could be used for the nuclear targeting of oligonucleotides. We synthesized a nuclear localization signal peptide-conjugated oligonucleotide to see if a nuclear localization signal peptide can enhance the uptake of oligonucleotides into reconstituted nuclei of Xenopus. Uptake of the NLS peptide-conjugated oligonucleotide was comparable to the control oligonucleotide at similar concentrations, suggesting that the NLS signal peptide does not significantly enhance the nuclear accumulation of oligonucleotides. This result is probably due to the small size of the oligonucleotide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nuclear weak interaction rates, including electron and positron emission rates, and continuum electron and positron capture rates , as well as the associated v and –/v energy loss rates are calculated on a detailed grid of temperature and density for the free nucleons and 226 nuclei with masses between A = 21 and 60. Gamow-Teller and Fermi discrete-state transition matrix element systematics and the Gamow-Teller T^< →/← T^> resonance transitions are discussed in depth and are implemented in the stellar rate calculations. Results of the calculations are presented on an abbreviated grid of temperature and density and comparison is made to terrestrial weak transition rates where possible. Neutron shell blocking of allowed electron capture on heavy nuclei during stellar core collapse is discussed along with several unblocking mechanisms operative at high temperature and density. The results of one-zone collapse calculations are presented which suggest that the effect of neutron shell blocking is to produce a larger core lepton fraction at neutrino trapping which leads to a larger inner-core mass and hence a stronger post-bounce shock.