931 resultados para Urban Simulation Model
Resumo:
Sustaining irrigated agriculture to meet food production needs while maintaining aquatic ecosystems is at the heart of many policy debates in various parts of the world, especially in arid and semi-arid areas. Researchers and practitioners are increasingly calling for integrated approaches, and policy-makers are progressively supporting the inclusion of ecological and social aspects in water management programs. This paper contributes to this policy debate by providing an integrated economic-hydrologic modeling framework that captures the socio-economic and environmental effects of various policy initiatives and climate variability. This modeling integration includes a risk-based economic optimization model and a hydrologic water management simulation model that have been specified for the Middle Guadiana basin, a vulnerable drought-prone agro-ecological area with highly regulated river systems in southwest Spain. Namely, two key water policy interventions were investigated: the implementation of minimum environmental flows (supported by the European Water Framework Directive, EU WFD), and a reduction in the legal amount of water delivered for irrigation (planned measure included in the new Guadiana River Basin Management Plan, GRBMP, still under discussion). Results indicate that current patterns of excessive water use for irrigation in the basin may put environmental flow demands at risk, jeopardizing the WFD s goal of restoring the ?good ecological status? of water bodies by 2015. Conflicts between environmental and agricultural water uses will be stressed during prolonged dry episodes, and particularly in summer low-flow periods, when there is an important increase of crop irrigation water requirements. Securing minimum stream flows would entail a substantial reduction in irrigation water use for rice cultivation, which might affect the profitability and economic viability of small rice-growing farms located upstream in the river. The new GRBMP could contribute to balance competing water demands in the basin and to increase economic water productivity, but might not be sufficient to ensure the provision of environmental flows as required by the WFD. A thoroughly revision of the basin s water use concession system for irrigation seems to be needed in order to bring the GRBMP in line with the WFD objectives. Furthermore, the study illustrates that social, economic, institutional, and technological factors, in addition to bio-physical conditions, are important issues to be considered for designing and developing water management strategies. The research initiative presented in this paper demonstrates that hydro-economic models can explicitly integrate all these issues, constituting a valuable tool that could assist policy makers for implementing sustainable irrigation policies.
Resumo:
Purpose – The purpose of this paper is to present a simulation‐based evaluation method for the comparison of different organizational forms and software support levels in the field of supply chain management (SCM). Design/methodology/approach – Apart from widely known logistic performance indicators, the discrete event simulation model considers explicitly coordination cost as stemming from iterative administration procedures. Findings - The method is applied to an exemplary supply chain configuration considering various parameter settings. Curiously, additional coordination cost does not always result in improved logistic performance. Influence factor variations lead to different organizational recommendations. The results confirm the high importance of (up to now) disregarded dimensions when evaluating SCM concepts and IT tools. Research limitations/implications – The model is based on simplified product and network structures. Future research shall include more complex, real world configurations. Practical implications – The developed method is designed for the identification of improvement potential when SCM software is employed. Coordination schemes based only on ERP systems are valid alternatives in industrial practice because significant investment IT can be avoided. Therefore, the evaluation of these coordination procedures, in particular the cost due to iterations, is of high managerial interest and the method provides a comprehensive tool for strategic IT decision making. Originality/value – Reviewed literature is mostly focused on the benefits of SCM software implementations. However, ERP system based supply chain coordination is still widespread industrial practice but associated coordination cost has not been addressed by researchers.
Resumo:
The crop simulation model AquaCrop, recently developed by FAO can be used for a wide range of purposes. However, in its present form, its use over large areas or for applications that require a large number of simulations runs (e.g., long-term analysis), is not practical without developing software to facilitate such applications. Two tools for managing the inputs and outputs of AquaCrop, named AquaData and AquaGIS, have been developed for this purpose and are presented here. Both software utilities have been programmed in Delphi v. 5 and in addition, AquaGIS requires the Geographic Information System (GIS) programming tool MapObjects. These utilities allow the efficient management of input and output files, along with a GIS module to develop spatial analysis and effect spatial visualization of the results, facilitating knowledge dissemination. A sample of application of the utilities is given here, as an AquaCrop simulation analysis of impact of climate change on wheat yield in Southern Spain, which requires extensive input data preparation and output processing. The use of AquaCrop without the two utilities would have required approximately 1000 h of work, while the utilization of AquaData and AquaGIS reduced that time by more than 99%. Furthermore, the use of GIS, made it possible to perform a spatial analysis of the results, thus providing a new option to extend the use of the AquaCrop model to scales requiring spatial and temporal analyses.
Resumo:
Un caloducto en bucle cerrado o Loop Heat Pipe (LHP) es un dispositivo de transferencia de calor cuyo principio de operación se basa en la evaporación/condensación de un fluido de trabajo, que es bombeado a través de un circuito cerrado gracias a fuerzas de capilaridad. Gracias a su flexibilidad, su baja masa y su mínimo (incluso nulo) consumo de potencia, su principal aplicación ha sido identificada como parte del subsistema de control térmico de vehículos espaciales. En el presente trabajo se ha desarrollado un LHP capaz de funcionar eficientemente a temperaturas de hasta 125 oC, siguiendo la actual tendencia de los equipos a bordo de satélites de incrementar su temperatura de operación. En la selección del diseño optimo para dicho LHP, la compatibilidad entre materiales y fluido de trabajo se identificó como uno de los puntos clave. Para seleccionar la mejor combinación, se llevó a cabo una exhaustiva revisión del estado del arte, además de un estudio especifico que incluía el desarrollo de un banco de ensayos de compatibilidad. Como conclusión, la combinación seleccionada como la candidata idónea para ser integrada en el LHP capaz de operar hasta 125 oC fue un evaporador de acero inoxidable, líneas de titanio y amoniaco como fluido de trabajo. En esa línea se diseñó y fabricó un prototipo para ensayos y se desarrolló un modelo de simulación con EcosimPro para evaluar sus prestaciones. Se concluyó que el diseño era adecuado para el rango de operación definido. La incompatibilidad entre el fluido de trabajo y los materiales del LHP está ligada a la generación de gases no condensables. Para un estudio más detallado de los efectos de dichos gases en el funcionamiento del LHP se analizó su comportamiento con diferentes cantidades de nitrógeno inyectadas en su cámara de compensación, simulando un gas no condensable formado en el interior del dispositivo. El estudio se basó en el análisis de las temperaturas medidas experimentalmente a distintos niveles de potencia y temperatura de sumidero o fuente fría. Adicionalmente, dichos resultados se compararon con las predicciones obtenidas por medio del modelo en EcosimPro. Las principales conclusiones obtenidas fueron dos. La primera indica que una cantidad de gas no condensable más de dos veces mayor que la cantidad generada al final de la vida de un satélite típico de telecomunicaciones (15 años) tiene efectos casi despreciables en el funcionamiento del LHP. La segunda es que el principal efecto del gas no condensable es una disminución de la conductancia térmica, especialmente a bajas potencias y temperaturas de sumidero. El efecto es más significativo cuanto mayor es la cantidad de gas añadida. Asimismo, durante la campaña de ensayos se observó un fenómeno no esperado para grandes cantidades de gas no condensable. Dicho fenómeno consiste en un comportamiento oscilatorio, detectado tanto en los ensayos como en la simulación. Este efecto es susceptible de una investigación más profunda y los resultados obtenidos pueden constituir la base para dicha tarea. ABSTRACT Loop Heat Pipes (LHPs) are heat transfer devices whose operating principle is based on the evaporation/condensation of a working fluid, and which use capillary pumping forces to ensure the fluid circulation. Thanks to their flexibility, low mass and minimum (even null) power consumption, their main application has been identified as part of the thermal control subsystem in spacecraft. In the present work, an LHP able to operate efficiently up to 125 oC has been developed, which is in line with the current tendency of satellite on-board equipment to increase their operating temperatures. In selecting the optimal LHP design for the elevated temperature application, the compatibility between the materials and working fluid has been identified as one of the main drivers. An extensive literature review and a dedicated trade-off were performed, in order to select the optimal combination of fluids and materials for the LHP. The trade-off included the development of a dedicated compatibility test stand. In conclusion, the combination of stainless steel evaporator, titanium piping and ammonia as working fluid was selected as the best candidate to operate up to 125 oC. An LHP prototype was designed and manufactured and a simulation model in EcosimPro was developed to evaluate its performance. The first conclusion was that the defined LHP was suitable for the defined operational range. Incompatibility between the working fluid and LHP materials is linked to Non Condensable Gas (NCG) generation. Therefore, the behaviour of the LHP developed with different amounts of nitrogen injected in its compensation chamber to simulate NCG generation, was analyzed. The LHP performance was studied by analysis of the test results at different temperatures and power levels. The test results were also compared to simulations in EcosimPro. Two additional conclusions can be drawn: (i) the effects of an amount of more than two times the expected NCG at the end of life of a typical telecommunications satellite (15 years) is almost negligible on the LHP operation, and (ii) the main effect of the NCG is a decrease in the LHP thermal conductance, especially at low temperatures and low power levels. This decrease is more significant with the progressive addition of NCG. An unexpected phenomenon was observed in the LHP operation with large NCG amounts. Namely, an oscillatory behaviour, which was observed both in the tests and the simulation. This effect provides the basis for further studies concerning oscillations in LHPs.
Resumo:
La infiltración de agua en el suelo y la recarga profunda del agua subterránea contenida en los acuíferos es un proceso lento en relación con otros fenómenos hidrológicos. La redacción de esta tesis ha pretendido contribuir al estudio de la influencia que el almacenamiento de la precipitación sólida en forma de manto de nieve y su eventual fusión puedan tener sobre dicho proceso en áreas de media montaña (1.000 – 2.000 m.) en las que con gran frecuencia se sitúan las cabeceras de los ríos peninsulares. Para ello se ha partido del análisis de las diferentes variables intervinientes durante un determinado periodo temporal y sobre un espacio geográfico concreto, por lo que su metodología es de naturaleza empírica. La extensión del periodo (2002/03 a 2010/11) ha venido condicionada por la disponibilidad de los valores de algunas de sus principales variables, como han sido el equivalente en agua de la nieve acumulada y los caudales procedentes de su fusión. Éstos se han obtenido como resultado de la aplicación del modelo ASTER, desarrollado en el programa de Evaluación de los Recursos Hídricos procedentes de la Innivación (ERHIN), calibrado – entre otros- con datos de precipitaciones, temperatura y caudales provenientes a su vez del Sistema Automático de Información Hidrológica (SAIH). Ambos programas fueron implantados por la Administración en las diferentes Confederaciones Hidrográficas y en determinados Organismos de cuenca actuales, en cuyo desarrollo participó el autor de esta tesis. En cuanto a la zona de estudio se ha procedido a su elección considerando las posibles áreas de media montaña en las que la presencia de la nieve fuera hidrológicamente significativa y estuvieran constituidas litológicamente por afloramientos permeables que no impidieran la infiltración en el terreno y la formación de acuíferos de cierta relevancia. El interés se centró discrecionalmente en la cuenca del Tajo, tanto por el carácter estratégico de la misma -como suministradora en la actualidad de excedentes a otras cuencas deficitarias- como por el valor representativo de sus condiciones climáticas y orográficas en relación con otras cuencas hidrográficas peninsulares. Para ello se partió de las cabeceras de ríos identificadas por el programa ERHIN por su interés nivológico para la implantación del modelo ASTER y de las Masas de Agua Subterráneas MASb (antes Unidades Hidrogeológicas UUHH) definidas en los planes hidrológicos. La intersección en el territorio de ambos criterios condujo, finalmente, a la zona del Alto Tajo, en la que se cumplen ambos requisitos. El tramo quedó concretado en el comprendido entre las cabeceras de los ríos Tajo y Guadiela y la cola de los embalses de Entrepeñas y Buendía respectivamente, puntos de cierre para la calibración llevada a cabo en la modelización ASTER. Gran parte de éste discurre, en su parte alta, sobre rocas carbonatadas (calizas y dolomías del Jurásico y Cretácico), relacionados con las MASb de Tajuña-Montes Universales, Molina de Aragón y Sigüenza-Maranchón. Los valores diarios de las reservas de agua en forma de nieve, evapotranspiración y caudales procedentes de la fusión se han obtenido a partir de los resultados del mencionado modelo, procediéndose al cálculo de la infiltración por balance hídrico durante el periodo de estudio considerado, teniendo en cuenta los valores de precipitación, evapotranspiración y aportaciones de caudales. Esto ha requerido el estudio previo de las condiciones hidrogeológicas de la zona seleccionada con objeto de conocer las posibles interconexiones subterráneas que pudieran alterar los saldos entre las variables intervinientes anteriormente citadas. Para ello se ha llevado a cabo la recopilación y análisis de la información hidrogeológica correspondiente a la documentación de los planes hidrológicos del Tajo (Plan Hidrológico de la cuenca del Tajo RD 1664/1998 y el actual Plan Hidrológico de la parte española de la Demarcación Hidrográfica del Tajo RD 270/2014) y de los estudios previos realizados por el organismo de cuenca y el Instituto Geológico y Minero de España (lGME) fundamentalmente. En relación con la MASb Tajuña-Montes Universales -cuya extensión supera la zona seleccionada- dichos estudios consideran su estructura geológica y distribución litológica, con intercalaciones impermeables que actúan como barreras, dividiendo a éstas en Subunidades e identificando las zonas de drenaje de sus respectivos acuíferos. También se ha considerado la documentación y estudios previos del Plan Hidrológico Nacional sobre las Unidades Hidrogeológicas compartidas entre ámbitos geográficos de diferentes planes hidrológicos. Se concluye que las divisorias hidrográficas de las cabeceras son sensiblemente coincidentes o abarcan las Subunidades Montes Universales meridionales, Priego, Cifuentes, Zaorejas, u Montes Universales septentrionales, que drenan hacia el Tajo/Guadiela (bien directamente, bien a través de afluentes como el Gallo, Ablanquejo, Cabrillas, Cuervo…), MASb Molina de Aragón, que drena al Tajo a través del río Gallo y MASb Sigüenza—Maranchón, que drena su parte correspondiente hacia el Tajo a través del Ablanquejo. Se descartan – salvo la pequeña salvedad del manantial de Cifuentes- las conexiones hidrogeológicas con otras MASb o Subunidades por lo que las cabeceras del Tajo y del Guadiela pueden considerarse como un Sistema independiente donde las precipitaciones no evaporadas escurren superficialmente o se infiltran y descargan hacia los embalses de Entrepeñas y Buendía. La cuantificación diaria y acumulada de los balances hídricos ha permitido calcular la evolución aproximada de las reservas de agua subterránea desde la fecha inicial. Originalmente los balances se realizaron de forma separada en las cabeceras del Tajo y del Guadiela, cuyos valores acumulados manifestaron una tendencia creciente en la primera y decreciente en la segunda. Dicha situación se equilibra cuando el balance se practica conjuntamente en ambas, apreciándose en la variación del volumen de agua subterránea una evolución acorde hidrológicamente con los ciclos de verano/invierno y periodos de sequía, manteniéndose sus valores medios a largo/medio plazo, poniendo en evidencia la existencia de interconexiones subterráneas entre ambas cuencas. El balance conjunto, agregando la cabecera del Tajuña (que también comparte los materiales permeables de la MASb Tajuña-Montes Universales) no reveló la existencia de nuevas interrelaciones hidrogeológicas que influyeran en los balances hídricos realizados Tajo/Guadiela, confirmando las conclusiones de los estudios hidrogeológicos anteriormente analizados. Se ha procedido a confrontar y validar los resultados obtenidos de la evolución de las reservas de agua subterránea mediante los siguientes procedimientos alternativos: - Cálculo de los parámetros de desagüe de la curva de agotamiento correspondiente al volumen de agua subterránea drenante hacia el Tajo/Guadiela. Éste se ha realizado a partir de las aportaciones mensuales entrantes en los embalses de Entrepeñas y Buendía durante los meses de junio, julio, agosto y septiembre, cuyos valores responden al perfil típico de descargas de un acuífero. A partir de éstos se ha determinado el volumen drenante correspondiente al primero de junio de cada año de la serie histórica considerada. - Determinación del caudal base por el método Wallingford y deducción de los volúmenes drenantes. Estimación de las recarga anuales - Cuantificación de la recarga anual por el método Sanz, Menéndez Pidal de Navascués y Távara. Se obtuvieron valores de recarga muy aproximados entre los calculados por los dos últimos procedimientos citados. Respecto a las reservas de agua subterránea almacenadas siguen una evolución semejante en todos los casos, lo que ha permitido considerar válidos los resultados conseguidos mediante balance hídrico. Confirmada su solidez, se han buscado correlaciones simples entre el volumen de las reservas subterráneas (como indicador estimativo del efecto de la infiltración) y los volúmenes procedentes de la fusión. La conclusión es que estos últimos no tienen un efecto determinante a escala anual sobre la infiltración,recarga y variación de los volúmenes de agua subterránea, frente al peso de otras variables (precipitación y evapotranspiración). No obstante se ha encontrado una buena correlación múltiple entre la recarga estimada y la precipitación eficaz (precipitación menos evapotranspiración) y fusión, que ha permitido cuantificar la contribución de esta última. Posteriormente se ha recurrido a la selección de los episodios más intensos de acumulación /fusión en las cabeceras del Tajo y Guadiela. Y se procedió a la comparación entre los resultados obtenidos por aplicación del modelo de simulación en los mismos periodos (normalmente de varios días de duración) con datos reales y con datos ficticios de temperatura que anularan o disminuyeran la presencia de nieve, apreciándose una gran sensibilidad del efecto de la temperatura sobre la evapotranspiración y estableciéndose nuevamente correlaciones lineales entre los volúmenes de fusión y el incremento de reservas subterráneas. Las mismas confirman el efecto “favorecedor” de la acumulación de agua en forma de nieve y su posterior licuación, sobre sobre la infiltración de agua en el suelo y almacenamiento subterráneo. Finalmente se establecieron varios escenarios climáticos (+1ºC; +3ºC; +1ºC y – 10% precipitación; y 3ºC – 10% precipitación) compatibles con las previsiones del IPCC para mediados y finales del presente siglo, determinándose mediante simulación ASTER los correspondientes valores de fusión. La correlación establecida a escala anual ha permitido evaluar el efecto de la disminución del volumen de fusión - en los diferentes escenarios – sobre la recarga, pronosticando un descenso de los caudales de estiaje y la desaparición del “efecto nieve” sobre la infiltración y recarga con un aumento de 3ºC de temperatura. Teniendo en cuenta las condiciones de representatividad de la zona elegida, resulta verosímil la extensión de las anteriores conclusiones a otras cabeceras fluviales enclavadas en áreas de media montaña situadas entre 1000 a 2000m y sus efectos aguas abajo.Water infiltration into the soil and groundwater recharge deep water in aquifers is slow relative to other hydrological phenomena. The wording of this thesis aims to contribute to the study of the influence that the storage of solid precipitation as snow cover and its eventual melting may have on this process in mid-mountain areas (1000 - 2,000 m) where very often the headwaters of the peninsular rivers are located. For this party analysis of the different variables involved has over a given time period and a particular geographical area, so that their methodology is empirical in nature. The extension of the period (2002/03 to 2010/11) has been conditioned by the availability of the values of some of its key variables, as were the water equivalent of the snow and flows from melting. These have been obtained as a result of the application of ASTER model, developed in the program Evaluation of Water Resources from the Innivation (ERHIN), calibrated - among others data of rainfall, temperature and flow from turn System Automatic Hydrological Information (SAIH). Both programs were implemented by the Administration in the different Water Boards and to undertakings for current basin, in which the author participated development of this thesis. As for the study area has proceeded at its option considering the possible areas of midmountain in the presence of snow outside hydrological meaningful and they were lithology consisting of permeable outcrops that did not prevent infiltration into the ground and forming aquifers of some significance. We were interested discretion in the Tagus basin, therefore the strategic nature of it, as currently supplying surplus to other basins deficit- as the representative value of its climate and terrain conditions in relation to other peninsular river basins . To do this we started from the headwaters identified by the ERHIN program for its implementation snow interest to the ASTER model and Ground Water Bodies MASb (before UUHH Hydrogeological Units) defined in hydrological plans. The intersection in the territory of both criteria led eventually to the Alto Tajo, in which both requirements are met. The section was finalized in the period between the headwaters of the Tagus and Guadiela rivers and reservoirs end Entrepeñas and Buendia respectively checking points for calibration performed in ASTER modeling. Much of it runs on carbonate rocks (limestones and dolomites of Jurassic and Cretaceous) related MASb of Tajuña -Montes Universal, Molina de Aragón and Sigüenza-Maranchón. The daily values of water reserves in the form of snow, evapotranspiration and flow from melting were obtained from the results of this model, proceeding to the calculation of infiltration water balance during the study period considered, taking into account values of precipitation, evapotranspiration and input flow. This has required the prior examination of the hydrogeological conditions of your required in order to know the possible underground interconnections that could alter the balance between the intervening variables aforementioned area. For this we have carried out the collection and analysis of hydrogeological information relevant documentation Tagus river management plans (Hydrological Plan Tajo Basin RD 1664/1998 and the current Hydrological Plan of the Spanish part of the River Basin Tagus RD 270/2014) and previous studies by the basin organization and the Geological Survey of Spain (IGME) mainly. Regarding the MASb Tajuña- Montes Universal - whose length exceeds the area selected - these studies consider its geological structure and lithology distribution with waterproof collations that act as barriers, dividing it into subunits and identifying areas draining their respective aquifers. It has also considered the documentation and previous studies of the National Hydrological Plan on shared among different geographical areas management plans Hydrogeological Units. We conclude that river dividing the headers are substantially coincident or covering Subunits southern Universal Montes, Priego Cifuentes, Zaorejas and northern Universal Mounts, which drain into the Tagus / Guadiela (either directly or through tributaries such as Gallo, Ablanquejo , whitecaps , Raven ...), MASb Molina de Aragón which drains through the Tajo del Gallo and MASb Sigüenza- Maranchón river that drains into the Tagus using the Ablanquejo . Discarded - except the small exception of spring Cifuentes -hydrogeological connections with other MASb or Subunits so the headwaters of the Tagus and Guadiela be considered as a separate system, where rainfall not evaporated runs on surface or infiltrates and eventually discharged into reservoirs Entrepeñas and Buendia. The daily and cumulative quantification of water balances allowed us to compute the approximate evolution of groundwater reserves from its initial date. Initially balances were performed separately in the headwaters of the Tagus and Guadiela, whose cumulative values showed an increasing trend in the first and decreasing in the second. This situation is balanced when the balance is practiced together in both , appreciating the change in volume of groundwater hydrological evolution commensurate with the cycles of summer / winter and drought periods , keeping their average long / medium term values and putting in shows the existence of underground interconnections between the two basins. The overall balance, adding header Tajuña (which also shares the permeable materials MASb Tajuña -Montes Universal ) did not reveal the existence of new hydrogeological interrelationships that influenced water balances made Tajo / Guadiela, confirming the findings of the hydrogeological studies previously analyzed. We proceeded to confront and validate the results of the evolution of groundwater reserves by the following alternative procedures: - Calculate the parameters drain depletion curve corresponding to the volume of groundwater draining into the Tajo / Guadiela. This has been made from monthly inflows in the reservoirs of Entrepeñas and Buendia during the months of June, July, August and September, whose values match the typical profile of an aquifer discharges. From these has been determined for the first of June each year of the time series considered drainage volume - Determination of base flow by Wallingford method and deduction of drainage volumes. Estimate of annual recharge - Quantification of the annual recharge by the method Sanz Menéndez Pidal of Navascués and Távara. Very approximate values recharge between calculated for the last two mentioned methods were obtained. Concerning groundwater reserves stored follow a similar pattern in all cases, allowing consider valid the results achieved through water balance. Confirmed its robustness, simple correlations were sought between the volume of groundwater reserves (as estimated indicator of the effect of infiltration) and volumes from the melting. The conclusion is that the latter do not have a decisive effect on the annual scale infiltration, recharge and variation in volumes of groundwater, against the weight of other variables (precipitation and evapotranspiration). However found a good multiple correlation between the estimated recharge and effective precipitation (precipitation minus evapotranspiration) and fusion, which allowed quantify the contribution of the latter. Subsequently it has resorted to the selection of the most intense episodes of accumulation / melting in the headwaters of the Tagus and Guadiela. And we proceeded to the comparison between the results obtained by application of the simulation model in the same periods (usually several days) with real data and fictitious temperature data to annul or decrease the presence of snow, appreciating a great sensitivity of the effect of temperature on evapotranspiration and establishing linear correlations between the volumes of melting and increased groundwater reserves again. They confirm the “flattering " effect of water accumulation as snow and subsequent liquefaction of the infiltration of water into the soil and underground storage. Finally various climate scenarios (+1ºC; +3ºC; +1ºC y – 10% precipitation; y 3ºC – 10% precipitation) were established consistent with IPCC projections for mid - to late - century, determined through simulation ASTER corresponding values of melting. The correlation established on an annual scale has allowed to evaluate the effect of decreasing the volume of melt - in different scenarios - on recharge, predicting a decline in low flows and the disappearance of "snow effect" on infiltration and recharge with an increase of 3°C temperature. Given the conditions of representativeness of the chosen area, plausible extension of the above findings to other landlocked headwaters in mid-mountain areas located between 1000 to 2000m and its downstream effects.
Resumo:
This paper presents results of the validity study of the use of MATLAB/Simulink synchronous-machine block for power-system stability studies. Firstly, the waveforms of the theoretical synchronous-generator short-circuit currents are described. Thereafter, the comparison between the currents obtained through the simulation model in the sudden short-circuit test, are compared to the theoretical ones. Finally, the factory tests of two commercial generating units are compared to the response of the synchronous generator simulation block during sudden short-circuit, set with the same real data, with satisfactory results. This results show the validity of the use of this generator block for power plant simulation.
Resumo:
El presente trabajo tiene por objetivo generar una metodología validada que permita predecir el consumo de vehículos turismo circulando en cualquier tramo de vía a partir del perfil orográfico y del diagrama velocidad-tiempo. Para la generación de la metodología, se ha realizado un modelo de simulación con el programa ADVISOR que permite calcular el consumo de combustible para un determinado recorrido en el que se tiene en cuenta el perfil orográfico. Este modelo fue validado con datos reales medidos con equipos on-board y se usó para calcular el consumo de combustible diferencial debido al efecto de la pendiente de la vía, al poderse simular con y sin pendiente. Se realizaron múltiples simulaciones de recorridos con velocidad máxima variable con el fin de obtener un número significativo de datos. Con los resultados de las diferentes simulaciones, se realizó un estudio estadístico, para determinar las variables influyentes y se generó una función estadística (Ecuación de Consumo Estimado – ECE) que permite calcular el consumo de combustible debido a la pendiente de la vía, conociendo el consumo del vehículo en carretera llana (sin pendiente). Esta función estadística generada (ECE), se validó con datos reales medidos en tráfico real. Con el fin de darle generalidad y aplicabilidad a la función generada, y teniendo en cuenta que el consumo de combustible en carretera llana no está siempre disponible, se ha calculado el consumo de combustible sin pendiente utilizando la metodología Copert 4, metodología oficial desarrollada por la Agencia de Medio Ambiente de Europa (EEA) para la estimación de emisiones y consumo de combustible que está basada en datos experimentales pero que no tiene en cuenta la pendiente de la vía. La Ecuación de Consumo Estimado (ECE) aplicada a los consumos calculados por la metodología Copert 4, se valida también usando datos reales medidos en tráfico real y se comprueba que esta función se ajusta considerablemente bien a la realidad, con un error en el consumo acumulado frente al del ensayo real de un 1% y una correlación con el consumo instantáneo del ensayo real de 0,93. Se concluye, que la Función de Consumo Estimado (ECE), permite predecir el efecto de la pendiente sobre el consumo de combustible de un vehículo turismo en tráfico real con un error menor del 1%. Abstract This projects aims to develop a validated methodology that enables to predict cars consumption while circulating at any kind of road section based on its orographic outline and the speed-time diagram. In order to develop this methodology, a simulation model has been performed with the programme ADVISOR, that allows fuel consumption calculation for an specific route in which the orographic outline is considered. This model was validated by real data measured with an on-board equipment and it was used to calculate the differential fuel consumption caused by the effect of the slope on the road, as it was possible to simulate with or without slope. Many simulations were run with routes with variable maximum speed, aiming to obtain a significant amount of data. An statistical study was carried out with the results of those simulations with the purpose to determine the influential variables and an statistical function ( Estimated Consumption Equation – ECE) that enables fuel consumption calculation due to the road’s slope when the consumption of a vehicle on horizontal road (without any slope) is known. This statistical function (ECE) was validated by real data measured in real traffic conditions. With the purpose to generalise the function and increase its applicability, considering that the consumption of a vehicle on horizontal road is not always available, the nonslope fuel consumption has been calculated through Copert 4 methodology, which is the official methodology developed by the European Environmental Agency (EEA) for emissions and fuel consumption calculation based on experimental data, but without taking into consideration the road’s slope. The Estimated Consumption Equation (ECE) applied to the consumption calculated through Copert 4 methodology is also validated using real data measured in real traffic conditions. It was verified that this function considerably adjusts to reality, with an error on the accumulated consumption compared to the real test of 1% and a correlation with the real test immediate fuel consumption of 0,93. It is concluded that the Estimated Consumption Equation (ECE) enables to predict the effect of the slope on the fuel consumption of a car in real traffic conditions with an error less than 1%.
Plataforma de simulación en Matlab-Simulink de un accionamiento regulado para emular aerogeneradores
Resumo:
En este proyecto se desarrolla un modelo de simulación de un accionamiento controlado que emula el comportamiento de una turbina eólica, el cual se ha llevado a cabo a través del programa para simulación Matlab/Simulink. Su desarrollo se ha estructurado de la siguiente forma: Tras una breve introducción a la energía eólica y a las máquinas eléctricas objeto de estudio en este proyecto, se procede a la caracterización y representación de dichas maquinas dentro de la plataforma de simulación virtual Simulink. Posteriormente se explican posibles estrategias de control de la máquina de inducción, las cuales son aplicadas para la realización de un control de velocidad. Asimismo, se realiza un control vectorial de par de la máquina de inducción de modo que permita un seguimiento efectivo del par de referencia demandado por el usuario, ante distintas condiciones. Finalmente, se añade el modelo de turbina eólica de manera que, definiendo los valores de velocidad de viento, ángulo de paso y velocidad del eje, permite evaluar el par mecánico desarrollado por la turbina. Este modelo se valida comprobando su funcionamiento para diferentes puntos de operación ante diversas condiciones del par de carga. Las condiciones de carga se establecen acoplando al modelo de la turbina, un generador síncrono de imanes permanentes conectado a una carga resistiva. ! II! ABSTRACT In this project, the simulation model of a controlled drive that emulates the behaviour of a wind turbine is developed. It has been carried out through the platform for multidomian simulation called Matlab/Simulink. Its development has been structured as follows: After a brief introduction to the wind energy and the electrical machines studied in this project, these machines are characterized and represented into the virtual simulation platform, Simulink. Subsequently, the possible control strategies for the induction machine are explained and applied in order to carry out a speed control. Additionally, a torque vector control of the induction machine is performed, so as to enable an effective monitoring of the reference torque requested by the user, under different conditions. Finally, the wind turbine model is implemented so as to assess the turbine mechanical torque, after defining the wind speed, the pitch angle and the shaft speed values. This model is validated by testing its functionality for different operating points under various load torques. The load conditions are set up by attaching a permanent magnets synchronous machine, with a resistive load, to the turbine model.
Resumo:
Background: This study examined the daily surgical scheduling problem in a teaching hospital. This problem relates to the use of multiple operating rooms and different types of surgeons in a typical surgical day with deterministic operation durations (preincision, incision, and postincision times). Teaching hospitals play a key role in the health-care system; however, existing models assume that the duration of surgery is independent of the surgeon's skills. This problem has not been properly addressed in other studies. We analyze the case of a Spanish public hospital, in which continuous pressures and budgeting reductions entail the more efficient use of resources. Methods: To obtain an optimal solution for this problem, we developed a mixed-integer programming model and user-friendly interface that facilitate the scheduling of planned operations for the following surgical day. We also implemented a simulation model to assist the evaluation of different dispatching policies for surgeries and surgeons. The typical aspects we took into account were the type of surgeon, potential overtime, idling time of surgeons, and the use of operating rooms. Results: It is necessary to consider the expertise of a given surgeon when formulating a schedule: such skill can decrease the probability of delays that could affect subsequent surgeries or cause cancellation of the final surgery. We obtained optimal solutions for a set of given instances, which we obtained through surgical information related to acceptable times collected from a Spanish public hospital. Conclusions: We developed a computer-aided framework with a user-friendly interface for use by a surgical manager that presents a 3-D simulation of the problem. Additionally, we obtained an efficient formulation for this complex problem. However, the spread of this kind of operation research in Spanish public health hospitals will take a long time since there is a lack of knowledge of the beneficial techniques and possibilities that operational research can offer for the health-care system.
Resumo:
El trabajo está centrado en la construcción de una simulación y en el desarrollo de un control reactivo para un vehículo aéreo no tripulado con fin de participar en la séptima edición de la competición internacional IARC. Para cumplir los objetivos de la competición se van a estudiar técnicas existentes de inteligencia artificial aplicadas al control de vehículos aéreos no tripulados, así como las técnicas para la elaboración de un modelo de simulación realista sobre el que realizar las distintas pruebas. Por último, se explica el trabajo realizado para crear un controlador reactivo que satisface las reglas de la competición y permite al vehículo aéreo no tripulado operar de forma autónoma en el ambiente de la simulación. Para validar el comportamiento, se realizan casos de prueba y un estudio de los resultados.---ABSTRACT---This report is focused on the construction of a simulation and the development of a reactive control for an unmanned aerial vehicle in order to participate in the seventh edition of the international competition IARC. Artificial intelligence techniques applied to the control of unmanned aerial vehicles are going to be studied to meet the objectives of the competition, as well as techniques for developing a realistic simulation model on which to perform the different tests. Finally, the last part of the report explains the work accomplished to create a reactive controller that meets the rules of the competition and allows the unmanned aerial vehicle to operate autonomously in the simulation environment. Test cases and a study of the results is performed to validate the behavior.
Resumo:
La participación de los jóvenes en los procesos de planificación urbana en Lisboa, Madrid y Fortaleza ha sido tema central de la presente tesis. Los principales objetivos perseguidos consisten en: caracterizar y analizar críticamente las dimensiones más importantes de la participación de jóvenes universitarios en los procesos participativos; aportar características de interés juvenil para un “modelo” de planificación urbana; elaborar directrices para el diseño de actuaciones en un proceso urbano participativo desde la perspectiva de los jóvenes; establecer el alcance de un instrumento urbano participativo reglamentado por el gobierno local entre los jóvenes; determinar si la percepción de los jóvenes universitarios acerca de las acciones del gobierno local tiene influencia en los procesos participativos. El universo estadístico de la muestra lo conforman la totalidad de 737 jóvenes universitarios encuestados en Lisboa, Madrid y Fortaleza. Que se distribuye en 104 encuestados en Lisboa, 329 en Madrid, y 304 en la ciudad de Fortaleza. El cuestionario contiene preguntas: abiertas, cerradas y mixtas. La mayor parte de las cuestiones son cerradas, y en cuanto a las opciones de respuesta: en muchas preguntas se ha aplicado, una escala tipo Likert, entre 1 y 4, siendo 4 el grado más alto (totalmente de acuerdo), y 1 el grado más bajo (nada de acuerdo), y para otras, una opción múltiple, con solamente una opción de respuesta. Se realizó un cuestionario de 31 preguntas en Lisboa, y tras su aplicación y obtención de resultados se revisó y mejoró obteniendo un cuestionario de 23 preguntas que fue aplicado en Madrid y Fortaleza. Se realizan análisis descriptivos, y algún análisis factorial en diversas preguntas del cuestionario, y se estudian diferencias en función de las variables sociodemográficas planteadas. Los resultados constatan que es muy baja la participación en los procesos institucionalizados por el gobierno local, en contrapartida es bastante alta en los procesos organizados por los ciudadanos. La información limita la participación de los jóvenes y ya que estos reconocen como motivación estar más y mejor informados y controlar y acompañar las acciones de su gobierno local. Por otra parte, desean participar en grupo en foros y debates presenciales. Los jóvenes madrileños consideran que las etapas más importantes en un proceso urbano participativo son: información, seguimiento y evaluación, mientras que para los jóvenes de Fortaleza son: Fiscalización, concienciación e información. Se ha verificado que desde la percepción de los jóvenes de Lisboa los ciudadanos son consultados en los procesos urbanos participativos y de acuerdo con los jóvenes de Madrid y Fortaleza los ciudadanos son dirigidos, influenciados y manipulados. Los problemas de carácter urbano no tienen una conceptualización clara y precisa entre los jóvenes universitarios y los problemas urbanos que más afectan la vida de los jóvenes universitarios son aparcamientos, contaminación y seguridad urbana. Sin embargo, los transportes son apuntados por los jóvenes universitarios de Lisboa, Madrid y Fortaleza. Además no saben identificar los problemas de su barrio. Así como de las causas y consecuencias y soluciones de los problemas urbanos. Eligen como mejor estrategia para desarrollar un proceso urbano participativo el acuerdo entre técnicos, población y el gobierno local. Los jóvenes universitarios de Fortaleza apuntan directrices para una planificación urbana con énfasis en la seguridad urbana, la sostenibilidad y la investigación, tecnología e innovación. Por otro lado, los jóvenes universitarios de Madrid perfilan tres “modelos” de planificación urbana: un “Modelo” socio-económica, un “Modelo” sostenible e innovadora y un “Modelo” de Planificación Urbana con énfasis en espacios públicos, entretenimiento, seguridad urbana y deporte. Los jóvenes universitarios rechazan la idea que la planificación urbana lleva en cuenta sus perspectivas y opiniones. Respeto al Presupuesto Participativo, el alcance de dicho proceso entre los jóvenes universitarios es extremamente bajo. Sin embargo, opinan que la aproximación entre ciudadanos, técnicos y gobierno en los procesos de Presupuesto Participativo mejora la rendición de cuentas. Además los jóvenes creen que dichos procesos conceden un poder moderado a los ciudadanos, y consideran que el poder concedido en los procesos urbanos influye directamente en el interés y empeño en participar. ABSTRACT Youth participation in urban planning processes in Lisbon, Madrid and Fortaleza is the main subject of this thesis. Our key goals are the following: characterising and critically analysing the most important dimensions of young university students’ participation in participative processes; providing features of interest for the young for an urban planning “model”; developing a variety of guidelines for designing actions in a participative urban process from the perspective of young people; analysing the impact upon the young of a participative urban instrument implemented by the local government; determining whether young university students’ perception of local government actions influences participative processes. The statistical universe of the sample comprises a total of 737 young university students who were surveyed in Lisbon, Madrid and Fortaleza, distributed as follows: 104 respondents in Lisbon, 329 in Madrid, and 304 in Fortaleza. The survey is made up of open-ended, closed-ended and mixed questions. Most questions are closed-ended. Regarding the answer options, a Likert-type scale has been used in many questions. The scale ranges from 1 to 4, 4 being the highest value (completely agree) and 1 the lowest (completely disagree). Besides, there are multiple-choice questions with only one possible answer. A 31- question survey was conducted in Lisbon. After the survey was run and the results were obtained, it was reviewed and improved. The improved version was a 23- question survey which was conducted in Madrid and Fortaleza. Descriptive analyses as well as some factorial analyses are carried out in several questions, and differences are studied depending on the socio-demographic variables involved. The results show that participation in processes implemented by local governments is very low. In contrast, participation is quite high in processes organised by citizens. Information limits youth participation, as young people point out that they are motivated by more and better information and by the possibility of monitoring and keeping track of their local government actions. They also wish to take part in face-to-face group forums and discussions. Young people from Madrid think that the most important stages in participative urban processes are information, follow-up and assessment, whereas young people from Fortaleza highlight tax matters, awareness and information. It has been confirmed that Lisbon youth perceive that citizens are consulted in participative urban processes. Youth from Madrid and Fortaleza, on the other hand, state that citizens are directed, influenced and manipulated. Young university students do not have a clear, precise concept of urban problems. Among these, they are most affected by car parks, pollution and urban safety, but the transport problem is pointed out by young university students from Lisbon, Madrid and Fortaleza. Furthermore, they cannot identify the problems in their neighbourhoods, nor are they able to specify the causes, consequences and solutions of urban problems. Their preferred strategy for developing a participative urban process is an agreement between technicians, the population and the local government. Young university students from Fortaleza suggest guidelines for an urban planning approach emphasising urban safety, sustainability and research, technology and innovation. Those from Madrid, for their part, outline three urban planning “models”: a socioeconomic “model”, a sustainable and innovative “model”, and an urban planning “model” with a focus on public areas, entertainment, urban safety and sport. Young university students disagree that urban planning takes their perspectives and views into account. Moreover, the impact of the Participative Budget upon their lives is extremely low. In their opinion, however, closer collaboration between citizens, technicians and governments in Participative Budget processes promotes accountability. The young also think that these processes give moderate power to citizens, and in their view the power that can be exerted in urban processes directly influences the interest in participating and the will to do so.
Resumo:
El yacimiento Casablanca es un campo petrolífero maduro en etapa de agotamiento considerado como el más grande del mar Mediterráneo. Lleva en explotación desde 1977 y tiene una producción acumulada de 22.6 MMm3 de petróleo. La formación productiva consiste en carbonatos karstificados del Grupo Basal Terciario y del Mesozoico. El mecanismo de drenaje identificado es por empuje de agua de un gran acuífero activo considerado como infinito ya que ha mantenido la presión al 95% de la original después de casi 40 años de producción. En el año 1999, los pozos asociados al campo Casablanca producían unos 500 m3/d de agua que era tratada y vertida al mar. Para cumplir con las leyes medio ambientales de la época, se convirtió el pozo Casablanca-9 en pozo sumidero con el objetivo de devolver a la formación toda el agua producida de una manera segura, limpia y totalmente respetuosa con el medio ambiente. Años después se observó que ésta inyección no era inocua, sino que tenía un impacto en la producción de petróleo. En la presente tesis se ha definido una metodología que, mediante la experimentación en campo con trazadores, pruebe la existencia de comunicación entre pozos productores y pozos sumidero, rompiendo así el paradigma instaurado en el campo que reza que no es posible la recuperación mejorada mediante inyección de agua en Casablanca debido al gran acuífero existente. Los resultados obtenidos serán el punto de partida para la construcción de un modelo de simulación que permita verificar que es posible la aplicación de técnicas IOR/EOR, y más concretamente la recuperación mejorada mediante inyección de agua en presencia de un acuífero activo infinito. ABSTRACT Casablanca is a brown field in the decline stage and is considered as the largest field in the Mediterranean Sea. It has been on production since 1977 and the cumulative production is 22.6 MMm3 of oil. The productive reservoir formation consists on complex karstified carbonates from Basal Tertiary Group and Mesozoic. The drive mechanism identified is water drive by a large aquifer considered as infinite acting due to the pressure maintenance at 95% of the original after near 40 years of production. In 1999, the wells associated to Casablanca field produced about 500 m3/d of water that was treated and disposed to the sea. In order to comply with the environmental laws at that time, Casablanca-9 was converted from producer to water disposal well with the objective to dispose all the water back to the formation in a safe, clean and environmental fully respectful way. Years later, it was observed that injection was not innocuous, but had an impact on oil production. The methodology defined in this thesis will demonstrate the existence of communication between producers and disposal wells through field experiments with tracers, breaking the paradigm established in the field that says it is not possible to apply waterflooding techniques in Casablanca due to the existence of a strong infinite acting aquifer. The results obtained will be the starting point in order to build a simulation model able to demonstrate that the application of IOR / EOR techniques are suitable, more specifically water flooding techniques in presence of an infinite active aquifer.
Resumo:
O desenvolvimento de competências profissionais em processos de ensino-aprendizagem insere a simulação na perspectiva tecnológica realística de situações clínicas para atingir objetivos educacionais, visando segurança e qualidade. A ação competente operacionaliza saberes pela combinação de conhecimentos, habilidades e atitudes. A competência avaliação de risco para úlcera por pressão é privativa do enfermeiro, o agravo é indicador de qualidade e segurança do paciente. O objetivo do estudo foi avaliar o processo de ensino-aprendizagem ante a estratégia de simulação clínica, visando o desenvolvimento da competência profissional avaliação de risco para úlceras por pressão e seus respectivos conhecimentos, habilidades e atitudes. Fundamentou-se, teoricamente, o estudo, nos preceitos da andragogia, no modelo de Simulação da National League for Nursing/Jeffries, nas concepções de competências de Le Boterf e recomendações para prevenção de úlcera por pressão do NPUAP/ EPUAP. Trata-se de estudo descritivo com análise quanti e qualitativa, desenvolvido no Laboratório de Simulação da Universidade Federal do Piauí, em Teresina, com estudantes de enfermagem do último ano do curso. Constou de três etapas: construção e validação de conteúdo do instrumento para conhecimentos, habilidades e atitudes da competência, elaboração do plano de aula e sequência didática do cenário de simulação, aplicação de pré/pós-teste sobre o componente \"conhecimento\", aula expositiva, execução do cenário de simulação pelos estudantes, avaliação dos cenários pelo comitê de juízes e debriefing por grupo focal, após o cenário. Verificou-se confiabilidade do construto e do instrumento de medida da competência com concordância predominando de 80 a 100% de pertinência. O instrumento constou de 32 itens: conhecimento (14), habilidades (8) e atitudes (10), com escala de resposta de cinco pontos, de nada (1) a extremamente (5). Inicialmente o estudo contou com 35 estudantes. Desses, 29 (82,8%) participaram da simulação. Predominou o sexo feminino 22 (76%), faixa etária de 21 a 24 anos, 24 (82,7%) e procedentes de Universidades Públicas do Estado do Piauí (83%). Os resultados mostraram melhores níveis de combinação de saberes para o componente conhecimentos, após a aplicação das estratégias de ensino autorreferidos pelos estudantes. Na avaliação dos conhecimentos, habilidade e atitudes, durante o cenário, houve discordância entre os juízes: para o juiz 1 predominaram parâmetros negativos da escala (nada e muito pouco) e para o juiz 2 e 3 os positivos (bastante e extremamente). As comparações pelo teste de variância ANOVA mostraram diferenças significativas entre juiz 1 e 2 (p-valor = < 0,01) e juiz 1 e 3 (p-valor=<0,01) para todos os componentes. A análise dos dados obtidos, durante o debriefing, originou cinco categorias com suas respectivas unidades de registro temáticas pela análise de conteúdo de Bardin. Os resultados sugerem que a estratégia é capaz de resgatar o raciocínio operativo dos estudantes durante a ação, desenvolver pensamento crítico-reflexivo sobre a competência, identificar lacunas de aprendizagem, promover satisfação aos estudantes e melhorar a autoimagem profissional. Conclui-se que a estratégia possibilita o desenvolvimento da competência avaliação de risco para úlcera por pressão nas dimensões de saberes (conhecimento), fazeres (habilidades) e querer-agir, saber-agir e poder-agir (atitudes), explorados neste estudo.
Resumo:
No gerenciamento de recursos hídricos, a bacia hidrográfica é considerada a unidade natural de gestão. Suas características físicas definem um espaço onde a água converge para uma saída comum. O desenvolvimento integrado de uma bacia, bem como os possíveis conflitos ocasionados por demandas concorrentes do mesmo recurso, devem ser administrados respeitando esse conceito de unidade. No caso específico da bacia hidrográfica do Rio Jaguari, existe uma crescente preocupação relacionada aos usos múltiplos da água superficial. O rio Jaguari, importante afluente do Paraíba do Sul no estado de São Paulo, tem suas águas represadas para geração de energia elétrica e regularização de vazões. Nos últimos anos, tem-se constatado um crescente rebaixamento dos níveis operacionais da represa do Jaguari. Segundo estudos da sociedade civil organizada local, a tendência é de esgotamento do reservatório em poucos anos. Este trabalho aborda a questão do rebaixamento dos níveis de Jaguari através da aplicação do software DHI Mike Basin 2000. Trata-se de um simulador genérico para sistemas de recursos hídricos, de ampla aplicação. A bacia do Jaguari é representada em um modelo matemático e são simulados quatro cenários distintos de usos de água na bacia. Verifica-se que o problema é real e requer uma intervenção multi-institucional para ser solucionado.
Resumo:
O objeto deste trabalho é a análise do aproveitamento múltiplo do reservatório de Barra Bonita, localizado na confluência entre os rios Piracicaba e Tietê, no estado de São Paulo e pertencente ao chamado sistema Tietê-Paraná. Será realizada a otimização da operação do reservatório, através de programação linear, com o objetivo de aumentar a geração de energia elétrica, através da maximização da vazão turbinada. Em seguida, a partir dos resultados da otimização da geração de energia, serão utilizadas técnicas de simulação computacional, para se obter índices de desempenho conhecidos como confiabilidade, resiliência e vulnerabilidade, além de outros fornecidos pelo próprio modelo de simulação a ser utilizado. Estes índices auxiliam a avaliação da freqüência, magnitude e duração dos possíveis conflitos existentes. Serão analisados os possíveis conflitos entre a navegação, o armazenamento no reservatório, a geração de energia e a ocorrência de enchentes na cidade de Barra Bonita, localizada a jusante da barragem.