856 resultados para Tread Wear.
Resumo:
OBJECTIVES: Three dental topography measurements: Dirichlet Normal Energy (DNE), Relief Index (RFI), and Orientation Patch Count Rotated (OPCR) are examined for their interaction with measures of wear, within and between upper and lower molars in Alouatta palliata. Potential inferences of the "dental sculpting" phenomenon are explored. MATERIALS AND METHODS: Fifteen occluding pairs of howling monkey first molars (15 upper, 15 lower) opportunistically collected from La Pacifica, Costa Rica, were selected to sample wear stages ranging from unworn to heavily worn as measured by the Dentine Exposure Ratio (DER). DNE, RFI, and OPCR were measured from three-dimensional surface reconstructions (PLY files) derived from high-resolution CT scans. Relationships among the variables were tested with regression analyses. RESULTS: Upper molars have more cutting edges, exhibiting significantly higher DNE, but have significantly lower RFI values. However, the relationships among the measures are concordant across both sets of molars. DER and EDJL are curvilinearly related. DER is positively correlated with DNE, negatively correlated with RFI, and uncorrelated with OPCR. EDJL is not correlated with DNE, or RFI, but is positively correlated with OPCR among lower molars only. DISCUSSION: The relationships among these metrics suggest that howling monkey teeth adaptively engage macrowear. DNE increases with wear in this sample presumably improving food breakdown. RFI is initially high but declines with wear, suggesting that the initially high RFI safeguards against dental senescence. OPCR values in howling monkey teeth do not show a clear relationship with wear changes.
Resumo:
Aim: To investigate the characteristics, development and determinants of toothwear among Irish schoolchildren. Methods: A cross-sectional (examination at 16-years-old) and longitudinal (examinations at 5-,12-,14-years) study were conducted. Two indices were used to measure toothwear, children/parents completed a demographic profile and questionnaire on oral hygiene and dietary practices, health, and lifestyle in both studies. Saliva was collected from consenting 16-year-olds. The explanatory variables for the cross-sectional and longitudinal study were derived from children/parents responses. Differences in salivary profiles were determined for subsets; the protein concentration was determined with Bradford protein assay and protein carbonyl concentration (a protein oxidation marker) was determined spectrophotometrically. Gel-electrophoresis and mass spectrometry determined proteins and ion chromatography inorganic ions. Statistical significance was accepted at p<0.05. Results: At 16-years-old the prevalence of toothwear with dentine visible was 44%. No difference in salivary flow rates existed. In unstimulated saliva a higher mean, protein carbonyl (p<0.0001) and total calcium concentration (p<0.002) existed for the group with moderate toothwear. In stimulated saliva the moderate toothwear group had a lower mean protein concentration(p<0.0001). The 2-DE protein spots prepared for a sub-group differed between those with toothwear and without. Mass spectrometry, identified one of the different proteins as IgA. For 16-year-olds, the self-reported factors indicated that brushing after breakfast was associated with lower toothwear scores(p<0.03). Nail-biting, being asthmatic or reporting a dry mouth were associated with higher toothwear scores(all p<0.05). Eating an apple daily or less was associated with less toothwear(p<0.002). In the longitudinal study toothwear into dentine at age five or 12-years was associated with more toothwear at age 14(all p<0.05). Discussion: The results illustrate the multifactorial aetiology of toothwear. The biochemical and physical correlates of saliva with toothwear requires further research. Conclusion: The impact of previous toothwear, salivary, dietary and personal factors on toothwear in the early permanent dentition is demonstrated.
Resumo:
BACKGROUND: Moderate-to-vigorous physical activity (MVPA) is an important determinant of children’s physical health, and is commonly measured using accelerometers. A major limitation of accelerometers is non-wear time, which is the time the participant did not wear their device. Given that non-wear time is traditionally discarded from the dataset prior to estimating MVPA, final estimates of MVPA may be biased. Therefore, alternate approaches should be explored. OBJECTIVES: The objectives of this thesis were to 1) develop and describe an imputation approach that uses the socio-demographic, time, health, and behavioural data from participants to replace non-wear time accelerometer data, 2) determine the extent to which imputation of non-wear time data influences estimates of MVPA, and 3) determine if imputation of non-wear time data influences the associations between MVPA, body mass index (BMI), and systolic blood pressure (SBP). METHODS: Seven days of accelerometer data were collected using Actical accelerometers from 332 children aged 10-13. Three methods for handling missing accelerometer data were compared: 1) the “non-imputed” method wherein non-wear time was deleted from the dataset, 2) imputation dataset I, wherein the imputation of MVPA during non-wear time was based upon socio-demographic factors of the participant (e.g., age), health information (e.g., BMI), and time characteristics of the non-wear period (e.g., season), and 3) imputation dataset II wherein the imputation of MVPA was based upon the same variables as imputation dataset I, plus organized sport information. Associations between MVPA and health outcomes in each method were assessed using linear regression. RESULTS: Non-wear time accounted for 7.5% of epochs during waking hours. The average minutes/day of MVPA was 56.8 (95% CI: 54.2, 59.5) in the non-imputed dataset, 58.4 (95% CI: 55.8, 61.0) in imputed dataset I, and 59.0 (95% CI: 56.3, 61.5) in imputed dataset II. Estimates between datasets were not significantly different. The strength of the relationship between MVPA with BMI and SBP were comparable between all three datasets. CONCLUSION: These findings suggest that studies that achieve high accelerometer compliance with unsystematic patterns of missing data can use the traditional approach of deleting non-wear time from the dataset to obtain MVPA measures without substantial bias.
Resumo:
The erosion processes resulting from flow of fluids (gas-solid or liquid-solid) are encountered in nature and many industrial processes. The common feature of these erosion processes is the interaction of the fluid (particle) with its boundary thus resulting in the loss of material from the surface. This type of erosion in detrimental to the equipment used in pneumatic conveying systems. The puncture of pneumatic conveyor bends in industry causes several problems. Some of which are: (1) Escape of the conveyed product causing health and dust hazard; (2) Repairing and cleaning up after punctures necessitates shutting down conveyors, which will affect the operation of the plant, thus reducing profitability. The most common occurrence of process failure in pneumatic conveying systems is when pipe sections at the bends wear away and puncture. The reason for this is particles of varying speed, shape, size and material properties strike the bend wall with greater intensity than in straight sections of the pipe. Currently available models for predicting the lifetime of bends are inaccurate (over predict by 80%. The provision of an accurate predictive method would lead to improvements in the structure of the planned maintenance programmes of processes, thus reducing unplanned shutdowns and ultimately the downtime costs associated with these unplanned shutdowns. This is the main motivation behind the current research. The paper reports on two aspects of the first phases of the study-undertaken for the current project. These are (1) Development and implementation; and (2) Testing of the modelling environment. The model framework encompasses Computational Fluid Dynamics (CFD) related engineering tools, based on Eulerian (gas) and Lagrangian (particle) approaches to represent the two distinct conveyed phases, to predict the lifetime of conveyor bends. The method attempts to account for the effect of erosion on the pipe wall via particle impacts, taking into account the angle of attack, impact velocity, shape/size and material properties of the wall and conveyed material, within a CFD framework. Only a handful of researchers use CFD as the basis of predicting the particle motion, see for example [1-4] . It is hoped that this would lead to more realistic predictions of the wear profile. Results, for two, three-dimensional test cases using the commercially available CFD PHOENICS are presented. These are reported in relation to the impact intensity and sensitivity to the inlet particle distributions.
Resumo:
Quenched and tempered high-speed steels obtained by powder metallurgy are commonly used in automotive components, such as valve seats of combustion engines. In order to machine these components, tools with high wear resistance and appropriate cutting edge geometry are required. This work aims to investigate the influence of the edge preparation of polycrystalline cubic boron nitride (PCBN) tools on the wear behavior in the orthogonal longitudinal turning of quenched and tempered M2 high-speed steels obtained by powder metallurgy. For this research, PCBN tools with high and low-CBN content have been used. Two different cutting edge geometries with a honed radius were tested: with a ground land (S shape) and without it (E shape). Also, the cutting speed was varied from 100 to 220 m/min. A rigid CNC lathe was used. The results showed that the high-CBN, E-shaped tool presented the longest life for a cutting speed of 100 m/min. High-CBN tools with a ground land and honed edge radius (S shaped) showed edge damage and lower values of the tool’s life. Low-CBN, S-shaped tools showed similar results, but with an inferior performance when compared with tools with high CBN content in both forms of edge preparation.
Resumo:
Background: Ceramic materials are used in a growing proportion of hip joint prostheses due to their wear resistance and biocompatibility properties. However, ceramics have not been applied successfully in total knee joint endoprostheses to date. One reason for this is that with strict surface quality requirements, there are significant challenges with regard to machining. High-toughness bioceramics can only be machined by grinding and polishing processes. The aim of this study was to develop an automated process chain for the manufacturing of an all-ceramic knee implant. Methods: A five-axis machining process was developed for all-ceramic implant components. These components were used in an investigation of the influence of surface conformity on wear behavior under simplified knee joint motion. Results: The implant components showed considerably reduced wear compared to conventional material combinations. Contact area resulting from a variety of component surface shapes, with a variety of levels of surface conformity, greatly influenced wear rate. Conclusions: It is possible to realize an all-ceramic knee endoprosthesis device, with a precise and affordable manufacturing process. The shape accuracy of the component surfaces, as specified by the design and achieved during the manufacturing process, has a substantial influence on the wear behavior of the prosthesis. This result, if corroborated by results with a greater sample size, is likely to influence the design parameters of such devices.
Resumo:
Background: Material wear testing is an important technique in the development and evaluation of materials for use in implant for total knee arthroplasty. Since a knee joint induces a complex rolling-gliding movement, standardised material wear testing devices such as Pin-on-Disc or Ring-on-Disc testers are suitable to only a limited extent because they generate pure gliding motion only.Methods: A rolling-gliding wear simulator was thus designed, constructed and implemented, which simulates and reproduces the rolling-gliding movement and loading of the knee joint on specimens of simplified geometry. The technical concept was to run a base-plate, representing the tibia plateau, against a pivoted cylindrical counter-body, representing one femur condyle under an axial load. A rolling movement occurs as a result of the friction and pure gliding is induced by limiting the rotation of the cylindrical counter-body. The set up also enables simplified specimens handling and removal for gravimetrical wear measurements. Long-term wear tests and gravimetrical wear measurements were carried out on the well known material pairings: cobalt chrome-polyethylene, ceramic-polyethylene and ceramic-ceramic, over three million motion cycles to allow material comparisons to be made.Results: The observed differences in wear rates between cobalt-chrome on polyethylene and ceramic on polyethylene pairings were similar to the differences of published data for existing material-pairings. Test results on ceramic-ceramic pairings of different frontal-plane geometry and surface roughness displayed low wear rates and no fracture failures.Conclusions: The presented set up is able to simulate the rolling-gliding movement of the knee joint, is easy to use, and requires a minimum of user intervention or monitoring. It is suitable for long-term testing, and therefore a useful tool for the investigation of new and promising materials which are of interest for application in knee joint replacement implants. © 2010 Richter et al; licensee BioMed Central Ltd.
Resumo:
Purpose: The primary outcome of this study is to compare the axial length growth of white European myopic children wearing orthokeratology contact lenses (OK) to a control group (CT) over a 7-year period. Methods: Subjects 6–12 years of age with myopia −0.75 to −4.00DS and astigmatism ≤1.00DC were prospectively allocated OK or distance single-vision spectacles (SV) correction. Measurements of axial length (Zeiss IOLMaster), corneal topography, and cycloplegic refraction were taken at 6-month intervals over a 2-year period. Subjects were invited to return to the clinic approximately 5 years later (i.e., 7 years after the beginning of the study) for assessment of their ocular refractive and biometric components. The CT consisted of 4 SV and 12 subjects who switched from SV to soft contact lens wear after the initial 2 years of SV lens wear. Changes in axial length relative to baseline over a 7-year period were compared between groups. Results: Fourteen and 16 subjects from the OK and CT groups, respectively, were examined 6.7 ± 0.5 years after the beginning of the study. Statistically significant changes in the axial length were found over time and between groups (both p <0.001), but not for the time*group interaction (p = 0.125). The change in the axial length for the OK group was 22% (p = 0.328), 42% (p = 0.007), 40% (p = 0.020), 41% (p = 0.013), and 33% (p = 0.062) lower than the CT group following 6, 12, 18, 24, and 84 months of lens wear, respectively. Conclusion: A trend toward a reduction in the rate of axial elongation of the order of 33% was found in the OK group in comparison to the CT group following 7 years of lens wear.
Resumo:
Purpose: In the present study, we consider mechanical properties of phosphate glasses under high temperatureinduced and under friction-induced cross-linking, which enhance the modulus of elasticity. Design/methodology/approach: Two nanomechanical properties are evaluated, the first parameter is the modulus of elasticity (E) (or Young's modulus) and the second parameter is the hardness (H). Zinc meta-, pyro - and orthophosphates were recognized as amorphous-colloidal nanoparticles were synthesized under laboratory conditions and showed antiwear properties in engine oil. Findings: Young's modulus of the phosphate glasses formed under high temperature was in the 60-89 GPa range. For phosphate tribofilm formed under friction hardness and the Young's modulus were in the range of 2-10 GPa and 40-215 GPa, respectively. The degree of cross-linking during friction is provided by internal pressure of about 600 MPa and temperature close to 1000°C enhancing mechanical properties by factor of 3 (see Fig 1). Research limitations/implications: The addition of iron or aluminum ions to phosphate glasses under high temperature - and friction-induced amorphization of zinc metaphosphate and pyrophosphate tends to provide more cross-linking and mechanically stronger structures. Iron and aluminum (FeO4 or AlO4 units), incorporated into phosphate structure as network formers, contribute to the anion network bonding by converting the P=O bonds into bridging oxygen. Future work should consider on development of new of materials prepared by solgel processes, eg., zinc (II)-silicic acid. Originality/value: This paper analyses the friction pressure-induced and temperature–induced the two factors lead phosphate tribofilm glasses to chemically advanced glass structures, which may enhance the wear inhibition. Adding the coordinating ions alters the pressure at which cross-linking occurs and increases the antiwear properties of the surface material significantly.