903 resultados para Tests for Continuous Lifetime Data


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Genome-wide association studies have been instrumental in identifying genetic variants associated with complex traits such as human disease or gene expression phenotypes. It has been proposed that extending existing analysis methods by considering interactions between pairs of loci may uncover additional genetic effects. However, the large number of possible two-marker tests presents significant computational and statistical challenges. Although several strategies to detect epistasis effects have been proposed and tested for specific phenotypes, so far there has been no systematic attempt to compare their performance using real data. We made use of thousands of gene expression traits from linkage and eQTL studies, to compare the performance of different strategies. We found that using information from marginal associations between markers and phenotypes to detect epistatic effects yielded a lower false discovery rate (FDR) than a strategy solely using biological annotation in yeast, whereas results from human data were inconclusive. For future studies whose aim is to discover epistatic effects, we recommend incorporating information about marginal associations between SNPs and phenotypes instead of relying solely on biological annotation. Improved methods to discover epistatic effects will result in a more complete understanding of complex genetic effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

• Examine current pile design and construction procedures used by the Iowa Department of Transportation (DOT). • Recommend changes and improvements to these procedures that are consistent with available pile load test data, soils information, and bridge design practice recommended by the Load and Resistance Factor Design (LRFD) approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In response to the mandate on Load and Resistance Factor Design (LRFD) implementations by the Federal Highway Administration (FHWA) on all new bridge projects initiated after October 1, 2007, the Iowa Highway Research Board (IHRB) sponsored these research projects to develop regional LRFD recommendations. The LRFD development was performed using the Iowa Department of Transportation (DOT) Pile Load Test database (PILOT). To increase the data points for LRFD development, develop LRFD recommendations for dynamic methods, and validate the results ofLRFD calibration, 10 full-scale field tests on the most commonly used steel H-piles (e.g., HP 10 x 42) were conducted throughout Iowa. Detailed in situ soil investigations were carried out, push-in pressure cells were installed, and laboratory soil tests were performed. Pile responses during driving, at the end of driving (EOD), and at re-strikes were monitored using the Pile Driving Analyzer (PDA), following with the CAse Pile Wave Analysis Program (CAPWAP) analysis. The hammer blow counts were recorded for Wave Equation Analysis Program (WEAP) and dynamic formulas. Static load tests (SLTs) were performed and the pile capacities were determined based on the Davisson’s criteria. The extensive experimental research studies generated important data for analytical and computational investigations. The SLT measured loaddisplacements were compared with the simulated results obtained using a model of the TZPILE program and using the modified borehole shear test method. Two analytical pile setup quantification methods, in terms of soil properties, were developed and validated. A new calibration procedure was developed to incorporate pile setup into LRFD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An equation for mean first-passage times of non-Markovian processes driven by colored noise is derived through an appropriate backward integro-differential equation. The equation is solved in a Bourret-like approximation. In a weak-noise bistable situation, non-Markovian effects are taken into account by an effective diffusion coefficient. In this situation, our results compare satisfactorily with other approaches and experimental data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS: Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS: The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS: Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The temporal dynamics of species diversity are shaped by variations in the rates of speciation and extinction, and there is a long history of inferring these rates using first and last appearances of taxa in the fossil record. Understanding diversity dynamics critically depends on unbiased estimates of the unobserved times of speciation and extinction for all lineages, but the inference of these parameters is challenging due to the complex nature of the available data. Here, we present a new probabilistic framework to jointly estimate species-specific times of speciation and extinction and the rates of the underlying birth-death process based on the fossil record. The rates are allowed to vary through time independently of each other, and the probability of preservation and sampling is explicitly incorporated in the model to estimate the true lifespan of each lineage. We implement a Bayesian algorithm to assess the presence of rate shifts by exploring alternative diversification models. Tests on a range of simulated data sets reveal the accuracy and robustness of our approach against violations of the underlying assumptions and various degrees of data incompleteness. Finally, we demonstrate the application of our method with the diversification of the mammal family Rhinocerotidae and reveal a complex history of repeated and independent temporal shifts of both speciation and extinction rates, leading to the expansion and subsequent decline of the group. The estimated parameters of the birth-death process implemented here are directly comparable with those obtained from dated molecular phylogenies. Thus, our model represents a step towards integrating phylogenetic and fossil information to infer macroevolutionary processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and objective: Oral anti-cancer treatments have expanded rapidly over the last years. While taking oral tablets at home ensures a better quality of life, it also exposes patients to the risk of sub-optimal adherence. The objective of this study is to assess how well ambulatory cancer patients execute their prescribed dosing regimen while they are engaged with continuous anti-cancer treatments. Design: This is an on-going longitudinal study. Consecutive patients starting an oral treatment are proposed to enter the study by the oncologist. Then they are referred to the pharmacy, where their oral anticancer treatment is dispensed in a Medication Event Monitoring System (MEMSTM), which records date and time of each opening of the drug container. Electronically compiled dosing history data from the MEMS are summarized and used as feedback during semistructured interviews with the pharmacist, which are dedicated to prevention and management of side effects. Interviews are scheduled before each medical visit. Report of the interview is available to the oncologist via an on-line secured portal. Setting: Seamless care approach between a Multidisciplinary Oncology Center and the Pharmacy of an Ambulatory Care and Community Medicine Department. Main outcome measures: For each patient, the comparison between the electronically compiled dosing history and the prescribed regimen was summarized using a daily binary indicator indicating whether yes or no the patient has taken the medication as prescribed. Results: Study started in March 2008. Among 22 eligible patients, 19 were included (11 men, median age 63 years old) and 3 (14%) refused to participate. 15 patients were prescribed a QD regimen, 3 patients a BID and 1 patient switched from QD to BID during follow-up. Median follow up was 182 days (IQR 72-252). Early discontinuation happened in four patients: side effects (n = 1), psychiatric reasons (n = 1), cancer progression (n = 1) and death (n = 1). On average, the daily number of medications was taken as prescribed in 99% of the follow-up days. Conclusions: Execution of the prescribed dosing regimens was almost perfect during the first 6 months. Maintaining this high degree of regimen execution and persistence over time might however be challenging in this population and need therefore to be confirmed in larger and longer follow-up cohort studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Meropenem, a carbapenem antibiotic displaying a broad spectrum of antibacterial activity, is administered in Medical Intensive Care Unit to critically ill patients undergoing continuous veno-venous haemodiafiltration (CVVHDF). However, there are limited data available to substantial rational dosing decisions in this condition. In an attempt to refine our knowledge and propose a rationally designed dosage regimen, we have developed a HPLC method to determine meropenem after solid-phase extraction (SPE) of plasma and dialysate fluids obtained from patients under CVVHDF. The assay comprises the simultaneous measurement of meropenem's open-ring metabolite UK-1a, whose fate has never been studied in CVVHDF patients. The clean-up procedure involved a SPE on C18 cartridge. Matrix components were eliminated with phosphate buffer pH 7.4 followed by 15:85 MeOH-phosphate buffer pH 7.4. Meropenem and UK-1a were subsequently desorbed with MeOH. The eluates were evaporated under nitrogen at room temperature (RT) and reconstituted in phosphate buffer pH 7.4. Separation was performed at RT on a Nucleosil 100-5 microm C18 AB cartridge column (125 x 4 mm I.D.) equipped with a guard column (8 x 4 mm I.D.) with UV-DAD detection set at 208 nm. The mobile phase was 1 ml min(-1), using a step-wise gradient elution program: %MeOH/0.005 M tetrabutylammonium chloride pH 7.4; 10/90-50/50 in 27 min. Over the range of 5-100 microg ml(-1), the regression coefficient of the calibration curves (plasma and dialysate) were >0.998. The absolute extraction recoveries of meropenem and UK-1a in plasma and filtrate-dialysate were stable and ranged from 88-93 to 72-77% for meropenem, and from 95-104 to 75-82% for UK-1a. In plasma and filtrate-dialysate, respectively, the mean intra-assay precision was 4.1 and 2.6% for meropenem and 4.2 and 3.7% for UK-1a. The inter-assay variability was 2.8 and 3.6% for meropenem and 2.3 and 2.8% for UK-1a. The accuracy was satisfactory for both meropenem and UK-1a with deviation never exceeding 9.0% of the nominal concentrations. The stability of meropenem, studied in biological samples left at RT and at +4 degrees C, was satisfactory with < 5% degradation after 1.5 h in blood but reached 22% in filtrate-dialysate samples stored at RT for 8 h, precluding accurate measurements of meropenem excreted unchanged in the filtrate-dialysate left at RT during the CVVHDF procedure. The method reported here enables accurate measurements of meropenem in critically ill patients under CVVHDF, making dosage individualisation possible in such patients. The levels of the metabolite UK-1a encountered in this population of patients were higher than those observed in healthy volunteers but was similar to those observed in patients with renal impairment under hemodialysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Research was conducted to investigate the potential of strengthening continuous bridges by post-tensioning. The study included the following: a literature review, selection and rating of a prototype continuous composite bridge, tests of a one-third-scale continuous composite bridge model, finite element analysis of the bridge model, and tests of a full-scale composite beam mockup for a negative moment region. The study results indicated that the strengthening of continuous, composite bridges is feasible. The primary objective in applyig the post-tensioning should be to provide moments opposite to those produced by live and dead loads. Longitudinal distribution of that post-tensioning always must be considered if only exterior or only interior beams are post-tensioned. Testing and finite element analysis showed that post-tensioning of positive moment regions with straight tendons was more effective than post-tensioning negative moment regions with straight tendons. Changes in tension in tendons may be either beneficial or detrimental when live loads are applied to a strengthened bridge and thus must be carefully considered in design.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The unifying objective of Phases I and II of this study was to determine the feasibility of the post-tensioning strengthening method and to implement the technique on two composite bridges in Iowa. Following completion of these two phases, Phase III was undertaken and is documented in this report. The basic objectives of Phase III were further monitoring bridge behavior (both during and after post-tensioning) and developing a practical design methodology for designing the strengthening system under investigation. Specific objectives were: to develop strain and force transducers to facilitate the collection of field data; to investigate further the existence and effects of the end restraint on the post-tensioning process; to determine the amount of post-tensioning force loss that occurred during the time between the initial testing and the retesting of the existing bridges; to determine the significance of any temporary temperature-induced post-tensioning force change; and to develop a simplified design methodology that would incorporate various variables such as span length, angle-of-skew, beam spacing, and concrete strength. Experimental field results obtained during Phases II and III were compared to the theoretical results and to each other. Conclusions from this research are as follows: (1) Strengthening single-span composite bridges by post-tensioning is a viable, economical strengthening technique. (2) Behavior of both bridges was similar to the behavior observed from the bridges during field tests conducted under Phase II. (3) The strain transducers were very accurate at measuring mid-span strain. (4) The force transducers gave excellent results under laboratory conditions, but were found to be less effective when used in actual bridge tests. (5) Loss of post-tensioning force due to temperature effects in any particular steel beam post-tensioning tendon system were found to be small. (6) Loss of post-tensioning force over a two-year period was minimal. (7) Significant end restraint was measured in both bridges, caused primarily by reinforcing steel being continuous from the deck into the abutments. This end restraint reduced the effectiveness of the post-tensioning but also reduced midspan strains due to truck loadings. (8) The SAP IV finite element model is capable of accurately modeling the behavior of a post-tensioned bridge, if guardrails and end restraints are included in the model. (9) Post-tensioning distribution should be separated into distributions for the axial force and moment components of an eccentric post-tensioning force. (10) Skews of 45 deg or less have a minor influence on post-tensioning distribution. (11) For typical Iowa three-beam and four-beam composite bridges, simple regression-derived formulas for force and moment fractions can be used to estimate post-tensioning distribution at midspan. At other locations, a simple linear interpolation gives approximately correct results. (12) A simple analytical model can accurately estimate the flexural strength of an isolated post-tensioned composite beam.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article describes a method for determining the polydispersity index Ip2=Mz/Mw of the molecular weight distribution (MWD) of linear polymeric materials from linear viscoelastic data. The method uses the Mellin transform of the relaxation modulus of a simple molecular rheological model. One of the main features of this technique is that it enables interesting MWD information to be obtained directly from dynamic shear experiments. It is not necessary to achieve the relaxation spectrum, so the ill-posed problem is avoided. Furthermore, a determinate shape of the continuous MWD does not have to be assumed in order to obtain the polydispersity index. The technique has been developed to deal with entangled linear polymers, whatever the form of the MWD is. The rheological information required to obtain the polydispersity index is the storage G′(ω) and loss G″(ω) moduli, extending from the terminal zone to the plateau region. The method provides a good agreement between the proposed theoretical approach and the experimental polydispersity indices of several linear polymers for a wide range of average molecular weights and polydispersity indices. It is also applicable to binary blends.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To determine if the results of resin-dentin microtensile bond strength (µTBS) is correlated with the outcome parameters of clinical studies on non-retentive Class V restorations. METHODS: Resin-dentin µTBS data were obtained from one test center; the in vitro tests were all performed by the same operator. The µTBS testing was performed 8h after bonding and after 6 months of storing the specimens in water. Pre-test failures (PTFs) of specimens were included in the analysis, attributing them a value of 1MPa. Prospective clinical studies on cervical restorations (Class V) with an observation period of at least 18 months were searched in the literature. The clinical outcome variables were retention loss, marginal discoloration and marginal integrity. Furthermore, an index was formulated to be better able to compare the laboratory and clinical results. Estimates of adhesive effects in a linear mixed model were used to summarize the clinical performance of each adhesive between 12 and 36 months. Spearman correlations between these clinical performances and the µTBS values were calculated subsequently. RESULTS: Thirty-six clinical studies with 15 adhesive/restorative systems for which µTBS data were also available were included in the statistical analysis. In general 3-step and 2-step etch-and-rinse systems showed higher bond strength values than the 2-step/3-step self-etching systems, which, however, produced higher values than the 1-step self-etching and the resin modified glass ionomer systems. Prolonged water storage of specimens resulted in a significant decrease of the mean bond strength values in 5 adhesive systems (Wilcoxon, p<0.05). There was a significant correlation between µTBS values both after 8h and 6 months of storage and marginal discoloration (r=0.54 and r=0.67, respectively). However, the same correlation was not found between µTBS values and the retention rate, clinical index or marginal integrity. SIGNIFICANCE: As µTBS data of adhesive systems, especially after water storage for 6 months, showed a good correlation with marginal discoloration in short-term clinical Class V restorations, longitudinal clinical trials should explore whether early marginal staining is predictive for future retention loss in non-carious cervical restorations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flood effectiveness observations imply that two families of processes describe the formation of debris flow volume. One is related to the rainfall?erosion relationship, and can be seen as a gradual process, and one is related to additional geological/geotechnical events, those named hereafter extraordinary events. In order to discuss the hypothesis of coexistence of two modes of volume formation, some methodologies are applied. Firstly, classical approaches consisting in relating volume to catchments characteristics are considered. These approaches raise questions about the quality of the data rather than providing answers concerning the controlling processes. Secondly, we consider statistical approaches (cumulative number of events distribution and cluster analysis) and these suggest the possibility of having two distinct families of processes. However the quantitative evaluation of the threshold differs from the one that could be obtained from the first approach, but they all agree in the sense of the coexistence of two families of events. Thirdly, a conceptual model is built exploring how and why debris flow volume in alpine catchments changes with time. Depending on the initial condition (sediment production), the model shows that large debris flows (i.e. with important volume) are observed in the beginning period, before a steady-state is reached. During this second period debris flow volume such as is observed in the beginning period is not observed again. Integrating the results of the three approaches, two case studies are presented showing: (1) the possibility to observe in a catchment large volumes that will never happen again due to a drastic decrease in the sediment availability, supporting its difference from gradual erosion processes; (2) that following a rejuvenation of the sediment storage (by a rock avalanche) the magnitude?frequency relationship of a torrent can be differentiated into two phases, the beginning one with large and frequent debris flow and a later one with debris flow less intense and frequent, supporting the results of the conceptual model. Although the results obtained cannot identify a clear threshold between the two families of processes, they show that some debris flows can be seen as pulse of sediment differing from that expected from gradual erosion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report is formatted to independently present four individual investigations related to similar web gap fatigue problems. Multiple steel girder bridges commonly exhibit fatigue cracking due to out-of-plane displacement of the web near the diaphragm connections. This fatigue-prone web gap area is typically located in negative moment regions of the girders where the diaphragm stiffener is not attached to the top flange. In the past, the Iowa Department of Transportation has attempted to stop fatigue crack propagation in these steel girder bridges by drilling holes at the crack tips. Other nondestructive retrofits have been tried; in a particular case on a two-girder bridge with floor beams, angles were bolted between the stiffener and top flange. The bolted angle retrofit has failed in the past and may not be a viable solution for diaphragm bridges. The drilled hole retrofit is often only a temporary solution, so a more permanent and effective retrofit is required. A new field retrofit has been developed that involves loosening the bolts in the connection between the diaphragm and the girders. Research on the retrofit has been initiated; however, no long-term studies of the effects of bolt loosening have been performed. The intent of this research is to study the short-term effects of the bolt loosening retrofit on I-beam and channel diaphragm bridges. The research also addressed the development of a continuous remote monitoring system to investigate the bolt loosening retrofit on an X-type diaphragm bridge over a number of months, ensuring that the measured strain and displacement reductions are not affected by time and continuous traffic loading on the bridge. The testing for the first three investigations is based on instrumentation of web gaps in a negative moment region on Iowa Department of Transportation bridges with I-beam, channel, and X-type diaphragms. One bridge of each type was instrumented with strain gages and deflection transducers. Field tests, using loaded trucks of known weight and configuration, were conducted on the bridges with the bolts in the tight condition and after implementing the bolt loosening retrofit to measure the effects of loosening the diaphragm bolts. Long-term data were also collected on the X-diaphragm bridge by a data acquisition system that collected the data continuously under ambient truck loading. The collected data were retrievable by an off-site modem connection to the remote data acquisition system. The data collection features and ruggedness of this system for remote bridge monitoring make it viable as a pilot system for future monitoring projects in Iowa. Results indicate that loosening the diaphragm bolts reduces strain and out-of-plane displacement in the web gap, and that the reduction is not affected over time by traffic or environmental loading on the bridge. Reducing the strain in the web gap allows the bridge to support more cycles of loading before experiencing fatigue, thus increase the service life of the bridge. Two-girder floor beam bridges may also exhibit fatigue cracking in girder webs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The AASHO specifications for highway bridges require that in designing a bridge, the live load must be multiplied by an impact factor for which a formula is given, dependent only upon the length of the bridge. This formula is a result of August Wohler's tests on fatigue in metals, in which he determined that metals which are subjected to large alternating loads will ultimately fail at lower stresses than those which are subjected only to continuous static loads. It is felt by some investigators that this present impact factor is not realistic, and it is suggested that a consideration of the increased stress due to vibrations caused by vehicles traversing the span would result in a more realistic impact factor than now exists. Since the current highway program requires a large number of bridges to be built, the need for data on dynamic behavior of bridges is apparent. Much excellent material has already been gathered on the subject, but many questions remain unanswered. This work is designed to investigate further a specific corner of that subject, and it is hoped that some useful light may be shed on the subject. Specifically this study hopes to correlate, by experiment on a small scale test bridge, the upper limits of impact utilizing a stationary, oscillating load to represent axle loads moving past a given point. The experiments were performed on a small scale bridge which is located in the basement of the Iowa Engineering Experiment Station. The bridge is a 25 foot simply supported span, 10 feet wide, supported by four beams with a composite concrete slab. It is assumed that the magnitude of the predominant forcing function is the same as the magnitude of the dynamic force produced by a smoothly rolling load, which has a frequency determined by the passage of axles. The frequency of passage of axles is defined as the speed of the vehicle divided by the axle spacing. Factors affecting the response of the bridge to this forcing function are the bridge stiffness and mass, which determine the natural frequency, and the effects of solid damping due to internal structural energy dissipation.