987 resultados para Subtraction radiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

STUDY OBJECTIVES: To review the etiology and pathophysiology of pneumomediastinum in severe blunt trauma, with a special interest in one of its possible origins, the Macklin effect. The Macklin effect relates to a three-step pathophysiologic process: blunt traumatic alveolar ruptures, air dissection along bronchovascular sheaths, and spreading of this blunt pulmonary interstitial emphysema into the mediastinum. The clinical relevance of the Macklin effect was also evaluated. SETTING: A university hospital serving as a reference trauma center. PATIENTS: A selection of 51 patients with severe blunt trauma between 1995 and 2000. Inclusion criteria: Severe trauma or high-speed deceleration justifying chest CT; if chest CT demonstrated a pneumomediastinum, bronchoscopy and esophagoscopy were performed to rule out tracheobronchial or esophageal injury. DESIGN: Retrospective analysis of patients' clinical files, chest CT, and bronchoscopy and esophagoscopy reports. The Macklin effect was diagnosed when an air collection adjacent to a bronchus and a pulmonary vessel could be clearly identified on the chest CT. Clinical relevance of the Macklin effect was statistically evaluated regarding its repercussions on the pulmonary gas exchange function, the respective durations of intensive care and total hospital stay, and the associated injuries. RESULTS: Twenty (39%) Macklin effects and 5 tracheobronchial injuries (10%) were identified. One tracheobronchial injury occurred simultaneously with the Macklin effect. The presence of the Macklin effect affected neither the clinical profile nor the result of pulmonary gas analysis on hospital admission, but was associated with a significant (p < 0.001) lengthening of the intensive care stay. CONCLUSIONS: The Macklin effect is present in 39% of severe blunt traumatic pneumomediastinum detected by CT. Its identification does not rule out a tracheobronchial injury. The Macklin effect reflects severe trauma, since it is associated with significantly prolonged intensive care stay.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Human experience takes place in the line of mental-time (MT) created through imagination of oneself in different time-points in past or future (self-projection in time). Here we manipulated self-projection in MT not only with respect to one's life-events but also with respect to one's faces from different past and future time-points. Methods: We here compared MTT with respect to one's facial images from different time points in past and future (study 1: MT-faces) as well as with respect to different past and future life events (study 2: MT-events). Participants were asked to make judgments about past and future face images and past and future events from three different time-points: the present (Now), eight years earlier (Past) or eight years later (Future). In addition, as a control task participants were asked to make recognition judgments with respect to faces and memory-related judgments with respect to events without changing their habitual self-location in time. Behavioral measures and functional magnetic resonance imaging (fMRI) activity after subtraction of recognition and memory related activities show both absolute MT and relative MT effects for faces and events, signifying a fundamental brain mechanism of MT, disentangled from episodic memory functions. Results: Behavioural and event-related fMRI activity showed three independent effects characterized by (1) similarity between past recollection and future imagination, (2) facilitation of judgments related to the future as compared to the past, and (3) facilitation of judgments related to time-points distant from the present. These effects were found with respect to faces and events suggesting that the brain mechanisms of MT are independent of whether actual life episodes have to be re-/pre-experienced and recruited a common cerebral network including the medial-temporal, precuneus, inferior-frontal, temporo-parietal, and insular cortices. Conclusions: These behavioural and neural data suggest that self-projection in time is a crucial aspect of MT, relying on neural structures encoding memory, mental imagery, and self. Furthermore our results emphasize the idea that mental temporal processing is more strongly directed to future prediction than to past recollection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: This study is a single-institution validation of video-assisted thoracoscopic (VATS) resection of a small solitary pulmonary nodule (SPN) previously localized by a CT-guided hook-wire system in a consecutive series of 45 patients. METHODS: The records of all patients undergoing VATS resection for SPN preoperatively localized by CT-guided a hook-wire system from January 2002 to December 2004 were assessed with respect to failure to localize the lesion by the hook-wire system, conversion thoracotomy rate, duration of operation, postoperative complications, and histology of SPN. RESULTS: Forty-five patients underwent 49 VATS resections, with simultaneous bilateral SPN resection performed in 4. Preoperative CT-guided hook-wire localization failed in two patients (4%). Conversion thoracotomy was necessary in two patients (4%) because it was not possible to resect the lesion by a VATS approach. The average operative time was 50 min. Postoperative complications occurred in 3 patients (6%), one hemothorax and two pneumonia. The mean hospital stay was 5 days (range: 2-18 days). Histological assessment revealed inflammatory disease in 17 patients (38%), metastasis in 17 (38%), non-small-cell lung cancer (NSCLC) in 4 (9%), lymphoma in 3 (6%), interstitial fibrosis in 2 (4%), histiocytoma in one (2%), and hamartoma in one (2%). CONCLUSIONS: Histological analysis of resected SPN revealed unexpected malignant disease in more than 50% of the patients indicating that histological clarification of SPN seems warranted. Video-assisted thoracoscopic resection of SPN previously localized by a CT-guided hook-wire system is related to a low conversion thoracotomy rate, a short operation time, and few postoperative complications, and it is well suited for the clarification of SPN.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In our recent paper by Monnin et al. [Med. Phys. 33, 411-420 (2006)], an objective analysis of the relative performance of a computed radiography (CR) system using both standard single-side (ST-VI) and prototype dual-side read (ST-BD) plates was reported. The presampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of paediatric chest radiography, at an entrance detector air kerma of 5 microGy. Experiments demonstrated that, compared to the standard single-side read system, the MTF for the dual-side read system was slightly reduced, but a significant decrease in image noise resulted in a marked increase in DQE (+40%) in the low spatial frequency range. However, the DQE improvement for the ST-BD plate decreased with increasing spatial frequency, and, at spatial frequencies above 2.2 mm(-1), the DQE of the dual-side read system was lower than that of the single-side one.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 56-year-old patient admitted to hospital for the suspicion of an acute coronary syndrome underwent coronary angiography without detection of significant lesions. Seven days later the echocardiography showed acute severe aortic valve insufficiency. Intraoperatively we found a perforated leaflet probably due to lesion during transcatheter procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Plain film radiography often underestimates the extent of injury in children with epiphyseal fracture. Especially Salter-Harris V fractures (crush fracture of the epiphyseal plate) are often primarily not detected. MRI of the ankle was performed in 10 children aged 9-17 (mean 14) years with suspected epiphyseal injury using 1.0-T Magnetom Expert. The fractures were classified according to the Salter-Harris-Rang-Odgen classification and compared with the results of plain radiography. In one case MRI could exclude epiphyseal injury; in four cases the MRI findings changed the therapeutic management. The visualisation of the fracture in three orthogonal planes and the possibility of detection of cartilage and ligamentous injury in MR imaging makes this method superior to conventional radiography and CT. With respect to radiation exposure MRI instead of CT should be used for the diagnosis of epiphyseal injuries in children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Detailed comparison of effectiveness between organised and opportunistic mammography screening operating in the same country has seldom been carried out. PATIENTS AND METHODS: Prognostic indicators, as defined in the European Guidelines, were used to evaluate screening effectiveness in Switzerland. Matching of screening programmes' records with population-based cancer registries enabled to compare indicators of effectiveness by screening and detection modality (organised versus opportunistic screening, unscreened, interval cancers). Comparisons of prognostic profile were also drawn with two Swiss regions uncovered by service screening of low and high prevalence of opportunistic screening, respectively. RESULTS: Opportunistic and organised screening yielded overall little difference in prognostic profile. Both screening types led to substantial stage shifting. Breast cancer prognostic indicators were systematically more favourable in Swiss regions covered by a programme. In regions without a screening programme, the higher the prevalence of opportunistic screening, the better was the prognostic profile. CONCLUSIONS: Organised screening appeared as effective as opportunistic screening. Mammography screening has strongly influenced the stage distribution of breast cancer in Switzerland, and a favourable impact on mortality is anticipated. Extension of organised mammography screening to the whole of Switzerland can be expected to further improve breast cancer prognosis in a cost-effective way.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on a patient with Marfan syndrome who presented a Stanford type B dissection of the descending thoracic aorta in late pregnancy. After a cesarean section, the patient presented a severe obstruction of the mesenteric superior artery. An endovascular fenestration was performed (balloon and guidewire based fenestration). Computed tomography (CT) angiography revealed an intussusception 'like' image of the abdominal aortic layers as a consequence of the fenestration procedure. Because of aneurismal progression in the abdominal aorta, surgical repair of the abdominal aorta and intussusception material removal was achieved six weeks later. The patient is currently in good condition. We conclude that the intussusception could be induced by a guidewire. This fenestration procedure is not recommended in patients with structural aortic disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three-dimensional imaging and quantification of myocardial function are essential steps in the evaluation of cardiac disease. We propose a tagged magnetic resonance imaging methodology called zHARP that encodes and automatically tracks myocardial displacement in three dimensions. Unlike other motion encoding techniques, zHARP encodes both in-plane and through-plane motion in a single image plane without affecting the acquisition speed. Postprocessing unravels this encoding in order to directly track the 3-D displacement of every point within the image plane throughout an entire image sequence. Experimental results include a phantom validation experiment, which compares zHARP to phase contrast imaging, and an in vivo study of a normal human volunteer. Results demonstrate that the simultaneous extraction of in-plane and through-plane displacements from tagged images is feasible.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Painful femoro-acetabular impingement symptoms localized in the groin in flexion, adduction and internal rotation can be explained either by a primary disease of the labrum often post-traumatic, and more frequently as part of femoro-acetabular primary or secondary dysmorphia. The kinematic of the normal hip joint depends of peri-acetabular structures, geometry of joints and possible pathologies that could contribute to modify either the geometry or the proprioceptive function. By combining and analyzing these parameters it is possible to describe a joint concept of centricity, an essential parameter for optimal functions of the joint. The concept of overload is explained as the inability of the hip to ensure its centricity during activities that could lead to the occurrence of any degenerative disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Direct noninvasive visualization of the coronary vessel wall may enhance risk stratification by quantifying subclinical coronary atherosclerotic plaque burden. We sought to evaluate high-resolution black-blood 3D cardiovascular magnetic resonance (CMR) imaging for in vivo visualization of the proximal coronary artery vessel wall. METHODS AND RESULTS: Twelve adult subjects, including 6 clinically healthy subjects and 6 patients with nonsignificant coronary artery disease (10% to 50% x-ray angiographic diameter reduction) were studied with the use of a commercial 1.5 Tesla CMR scanner. Free-breathing 3D coronary vessel wall imaging was performed along the major axis of the right coronary artery with isotropic spatial resolution (1.0x1.0x1.0 mm(3)) with the use of a black-blood spiral image acquisition. The proximal vessel wall thickness and luminal diameter were objectively determined with an automated edge detection tool. The 3D CMR vessel wall scans allowed for visualization of the contiguous proximal right coronary artery in all subjects. Both mean vessel wall thickness (1.7+/-0.3 versus 1.0+/-0.2 mm) and wall area (25.4+/-6.9 versus 11.5+/-5.2 mm(2)) were significantly increased in the patients compared with the healthy subjects (both P<0.01). The lumen diameter (3.6+/-0.7 versus 3.4+/-0.5 mm, P=0.47) and lumen area (8.9+/-3.4 versus 7.9+/-3.5 mm(2), P=0.47) were similar in both groups. CONCLUSIONS: Free-breathing 3D black-blood coronary CMR with isotropic resolution identified an increased coronary vessel wall thickness with preservation of lumen size in patients with nonsignificant coronary artery disease, consistent with a "Glagov-type" outward arterial remodeling. This novel approach has the potential to quantify subclinical disease.