967 resultados para Spine biomechanics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rat posterodorsal medial amygdala (MePD) is a brain area in which gonadal hormones induce notable plastic effects in the density of dendritic spines. Dendritic spines are post-synaptic specializations whose shape and spacing change neuronal excitability. Our aim was to obtain new data on the dendritic spines morphology and density from MePD neurons using the carbocyanine dye Dil under confocal microscopy. In adult male rats, the dendritic spine density of the medial branches of the left MePD (mean +/- SD) was 1.15 +/- 0.67 spines/dendritic mu m. From the total sampled, approximately 53% of the spines were classified as thin, 22.5% as ""mushroom-like"", and 21.5% as stubby/wide. Other spine shapes (3%) included those ramified, with a filopodium-like or a gemule appearance, and others with a protruding spinule. Additional experiment joining Dil and synaptophysin (a pre-synaptic protein) labeling suggested synaptic sites on dendritic shafts and spines. Dendritic spines showed synaptophysin puncta close to their head and neck, although some spines had no evident labeled puncta on them or, conversely, multiple puncta appeared upon one spine. These results advance previous light microscopy results by revealing features and complexities of the dendritic spines at the same time that give new insight on the possible synaptic organization of the adult rat MePD. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Golgi method has been used for over a century to describe the general morphology of neurons in the nervous system of different species. The ""single-section"" Golgi method of Gabbott and Somogyi (1984) and the modifications made by Izzo et al. (1987) are able to produce consistent results. Here, we describe procedures to show cortical and subcortical neurons of human brains immersed in formalin for months or even years. The tissue was sliced with a vibratome, post-fixed in a combination of paraformaldehyde and picric acid in phosphate buffer, followed by osmium tetroxide and potassium dicromate, ""sandwiched"" between cover slips, and immersed in silver nitrate. The whole procedure takes between 5 and 11 days to achieve good results. The Golgi method has its characteristic pitfalls but, with this procedure, neurons and glia appear well-impregnated, allowing qualitative and quantitative studies under light microscopy. This contribution adds to the basic techniques for the study of human nervous tissue with the same advantages described for the ""single-section"" Golgi method in other species; it is easy and fast, requires minimal equipment, and provides consistent results. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the study is to describe our experience in the surgical management of foramen magnum meningiomas with regard to the clinical-radiological findings, the surgical approach and the outcomes after mid-term follow up. Over a 5-year period, 15 patients presenting with meningiomas of the foramen magnum underwent surgical treatment. The medical records were reviewed in order to analyze the clinical-radiological aspects, as well as the surgical approach and the outcomes. Based on the preoperative magnetic resonance imaging exams, the tumors were classified as anterior or anterolateral in the axial slices and clivospinal or spinoclival in the sagittal slices. The lateral approach was used in all cases. However, the extent of bone removal and the management of the vertebral artery were tailored to each patient. Fourteen patients were females, and one was male, ranging in age from 42 to 74 years (mean 55,9 years). The occipital condyle was partially removed in eight patients, and in seven patients, removal was not necessary. Total removal of the tumor was achieved in 12 patients, subtotal in two, and partial resection in one patient. Postoperative complications occurred in two patients. Follow-up ranged from 6 to 56 months (mean 23.6 months).There was no surgical mortality in this series. The extent of the surgical approach to foramen magnum meningiomas must be based on the main point of dural attachment and tailored individually case-by-case. The differentiation between the clivospinal and spinoclival types, as well as anterior and anterolateral types, is crucial for the neurosurgical planning of foramen magnum meningiomas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It is difficult to precisely measure articular arc movement in newborns using a goniometer. This article proposes an objective method based on trigonometry for the evaluation of lower limb abduction. With the newborn aligned in the dorsal decubitus position, 2 points are marked at the level of the medial malleolus, one on the sagittal line and the other at the end of the abduction. Using the right-sided line between these 2 points and a line from the medial malleolus to the reference point at the anterior superior iliac spine or umbilical scar, an isosceles triangle is drawn, and half of the inferential abduction angle is obtained by calculating the sine. Twenty healthy full-term newborns comprise the study cohort. Intersubject and intrasubject variability among the abduction angle values (mean [SD], 37 degrees [4]degrees) is low. This method is advantageous because the measurement is precise and because the sine can be used without approximation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Ligation of the sphenopalatine artery is used to treat severe nasal haemorrhage. The objective of the study was to investigate the numerical variation of the sphenopalatine foramen (SPF), its relation to the ethmoid bone crista of the palatine bone in the lateral nasal wall, its distance from the anterior nasal spine and the angle between this distance and the anterior nasal floor. Material and Methods: Fifty-four hemiskulls were submitted to anatomical study and measurements using the Image Tool 3.0 software. Results: The SPF was single in 87% of the specimens, and more than one orifice was present in 13%. It was possible to establish a relation with the ethmoid crista, which is a surgical reference for the SIT location. The mean values of the measurements were significantly higher in the hemifaces than in the hemiskulls ranging from 54 to 63mm, and angulation ranged from 20 to 32 degrees. Conclusions: In most specimens studied, the SPF was single and located in the superior nasal meatus. The distances measured suggest that these values can be used as distance references for the use of the endoscope for ligation or endonasal cauterization of the branches of the sphenopalatine artery, preventing possible errors and complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Birth weight is positively associated with adult bone mass. However, it is not clear if its effect is already evident in early adulthood. Objective: To investigate the association between birth weight, adult body size, the interaction between them and bone mass in young adults. Methods: Bone densitometry by DXA was performed on 496 individuals (240 men) aged 23-24 years from the 1978/79 Ribeirao Preto (southern Brazil) birth cohort, who were born and still residing in the city in 2002. Birth weight and length as well as adult weight and height were directly measured and converted to z-scores. The influence of birth weight and length, and adult weight and height on bone area (BA), bone mineral content (BMC) and bone mineral density (BMD) at the lumbar spine, proximal femur and femoral neck were investigated through simple and multiple linear regression models. Adjustments were made for sex, skin color, gestational age, physical activity level, smoking status and dietary consumption of protein, calcium and alcohol. Interaction terms between birth weight and adult weight, and birth length and adult height were tested. Results: Men in the highest fertile of birth weight distribution had greater BA and BMC at all three bone sites when compared with their counterparts in the lowest tertiles (p<0.008). For BMD, this trend was observed only in the lumbar spine. Adult weight and height were positively associated with BA and BMC at all three bone sites (p<0.05). For BMD, these associations were seen for adult weight, but for adult height an association was observed only in the lumbar spine. Birth weight retained positive associations with proximal femur BA and BMC after adjustments for current weight and height. No interaction was observed between variables measuring prenatal growth and adult body size. Conclusion: Birth weight and postnatal growth are independent determinants of adult bone mass in a sample of Brazilian adults. This effect is already evident in early adulthood. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction. In view of the high prevalence of headache in the general population, the availability of well defined regarding the request of complementary exams is highly desirable. Aim. To analyze the criteria that will guide the physician requests of complementary exams during the investigation of headache. Patients and methods. The data were obtained by reviewing medical records of all patients who had been scheduled to be seen in a tertiary Headache Outpatient Clinic in 2004. Results. The exam most frequently requested was computed tomography of the head and the exams that most contributed to a change in clinical diagnosis or medical conduct were computed tomography of paranasal sinuses, simple rediography of paranasal sinuses. and magnetic resonance image of the brain. The exams that did not contribute to a change in the diagnosis or medical conduct were computed tomography and simple radiography of the cervical spine. As expected, the most expensive exams for the institution were computed tomography and magnetic resonance image. Conclusion. The importance of complementary exams in the investigation of headache is indisputable in many cases. Howerer, it is necessary the availability of more, studies that evaluate the request of complementay ; exams for headache patients. [REV NEUROL 2009: 48: 183-7]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To determine the relationships between eccentric hip and knee torques, symptom severity and functional capacity in females with patellofemoral pain syndrome (PFPS). Design: Within-subject correlational study. Setting: University biomechanics laboratory. Participants: 10 females diagnosed with PFPS. Main outcome measures: Eccentric strength of the hip abductors and lateral rotators, and knee extensors were assessed using an isokinetic dynamometer. A 10-cm visual analog scale was used to determine usual knee pain in the last week. The Anterior Knee Pain Scale (AKPS) was used to determine the functional capacity of the patients. Results: The study found that the greater the eccentric knee extensor and hip lateral rotator torques, the higher the functional capacity of the patients (p = 0.02, r = 0.72; p = 0.02, r = 0.72). It was also shown that the greater hip lateral rotator torque, the less the usual pain reported in the last week (p = 0.004, r = -0.84). Despite the lack of statistical significance (p = 0.11), it was also found a modest negative relationship between the eccentric knee extensor torque and the usual pain reported in the last week (r = -0.56) that was considered clinically meaningful (d = 1.4). Conclusions: This study showed that eccentric knee extensor and hip lateral rotator torques were associated with functional capacity and pain level in females with PFPS. Further investigations should be carried out to verify the effects of an intervention program focused on the eccentric action of these muscles with respect to the symptoms in patients with PFPS. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The clinical success of fiber posts has been attributed to their lower elastic modulus. The tested hypothesis was that fiber posts could lead to lower risk of post debonding and lower risk of root fracture, despite an increase in root stresses. Stress analyses were carried out with a 3D finite element model of a premolar restored with a metallic or a fiber post. Bonded and non-bonded post/cement interface conditions were simulated. We calculated risk-of-fracture indices by determining the highest principal stress values divided by the tensile strength. Shear stresses along the post/cement interface were analyzed for the bonded models. Compared with the premolar restored with a metallic post, the fiber post generated lower stresses along the interface and higher stresses in the root. However, with the fiber post, fracture was less likely to occur in the root, since its core and post fracture indices were higher.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Upper premolars restored with endodontic posts present a high incidence of vertical root fracture (VRF). Two hypotheses were tested: (1) the smaller mesiodistal diameter favors stress concentration in the root and (2) the lack of an effective bonding between root and post increases the risk of VRF. Using finite element analysis, maximum principal stress was analyzed in 3-dimensional intact upper second premolar models. From the intact models, new models were built including endodontic posts of different elastic modulus (E = 37 or E = 200 GPa) with circular or oval cross-section, either bonded or nonbonded to circular or oval cross-section root canals. The first hypothesis was partially confirmed because the conditions involving nonbonded, low-modulus posts showed lower tensile stress for oval canals compared to circular canals. Tensile stress peaks for the nonbonded models were approximately three times higher than for the bonded or intact models, therefore confirming the second hypothesis. (J Endod 2009;35:117-120)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To investigate the prevalence of upper cervical vertebrae anomalies in patients with isolated cleft lip, isolated cleft palate, and complete cleft lip and palate, as well as to compare the prevalence of these anomalies between groups, between genders, and with noncleft patients. Design: Retrospective cross-sectional study of randomly selected patients. Setting: Radiology Section, Hospital for Rehabilitation of Craniofacial Anomalies and Department of Orthodontics, Bauru School of Dentistry, University of Sao Paulo, Sao Paulo, Brazil. Participants: The sample comprised 300 lateral cephalograms of cleft patients, aged 12 to 13 years, of both genders, from the files of the Hospital for Rehabilitation of Craniofacial Anomalies-University of Sao Paulo and 300 lateral cephalograms from noncleft patients of the Department of Orthodontics, Bauru School of Dentistry. Cephalograms of patients with syndromes were not included. Method: Radiographs were interpreted on a film viewer by a single examiner; the profiles of vertebrae were traced on acetate paper, and cervical vertebrae anomalies were registered and categorized into posterior arch deficiencies, fusion, and association of both. Main Outcome Measures: Statistical comparison of groups using the chi-square test. Results: In the cleft group, 38.67% of the patients had cervical vertebrae anomalies. Of those in the noncleft sample, 31% showed anomalies of the cervical spine. This difference was statistically significant. There was no statistically significant difference when the types of clefts were compared with each other or when both genders were compared in both samples. Conclusions: This study confirms the association between clefts and cervical anomalies. Additional research on this topic is necessary.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the biomechanical and microscopic response of previously grafted bone to titanium implants. The lower incisors of 16 rabbits were surgically extracted, and bilateral perforations communicating with the remaining sockets were created distally. A socket/perforation defect on each mandible was chosen at random to be immediately filled with a xenogenic graft, whereas the contralateral perforation was left to heal naturally and served as a paired control. After 60 days, titanium implants were installed in the previously operated areas. After periods of 2 and 6 months, the animals were killed, and the force necessary to retrieve implants as well as the bone-implant contact (BIC) and bone mass (BM) were quantified and statistically compared by 2-way analysis of variance and Tukey`s test (alpha = .05). No significant differences in removal torque were observed, either by time or by treatment condition. Differences in BIC and BM between experimental and control groups were not statistically significant through the intervals studied (P < .05). The presence of a xenogenic graft did not influence the microscopic tissue response to titanium implants or fixation into newly formed or mature bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this in vitro study was to analyze the stress distribution on components of a mandibular-cantilevered implant-supported prosthesis with frameworks cast in cobalt-chromium (Co-Cr) or palladium-silver (Pd-Ag) alloys, according to the cantilever length. Frameworks were fabricated on (Co-Cr) and (Pd-Ag) alloys and screwed into standard abutments positioned on a master-cast containing five implant replicas. Two linear strain gauges were fixed on the mesial and distal aspects of each abutment to capture deformation. A vertical static load of 100 N was applied to the cantilever arm at the distances of 10, 15, and 20 mm from the center of the distal abutment and the absolute values of specific deformation were recorded. Different patterns of abutment deformation were observed according to the framework alloy. The Co-Cr alloy framework resulted in higher levels of abutment deformation than the silver-palladium alloy framework. Abutment deformation was higher with longer cantilever extensions. Physical properties of the alloys used for framework interfere with abutment deformations patterns. Excessively long cantilever extensions must be avoided. To cite this article:Jacques LB, Moura MS, Suedam V, Souza EAC, Rubo JH. Effect of cantilever length and framework alloy on the stress distribution of mandibular-cantilevered implant-supported prostheses.Clin. Oral Impl. Res. 20, 2009; 737-741.doi: 10.1111/j.1600-0501.2009.01712.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In cantilevered implant-supported complete prosthesis, the abutments` different heights represent different lever arms to which the abutments are subjected resulting in deformation of the components, which in turn transmit the load to the adjacent bone. The purpose of this in vitro study was to quantitatively assess the deformation of abutments of different heights in mandibular cantilevered implant-supported complete prosthesis. A circular steel master cast with five perforations containing implant replicas (O3.75 mm) was used. Two groups were formed according to the types of alloy of the framework (CoCr or PdAg). Three frameworks were made for each group to be tested with 4, 5.5 and 7 mm abutments. A 100 N load was applied at a point 15 mm distal to the center of the terminal implant. Readings of the deformations generated on the mesial and distal aspects of the abutments were obtained with the use of strain gauges. Deformation caused by tension and compression was observed in all specimens with the terminal abutment taking most of the load. An increase in deformation was observed in the terminal abutment as the height was increased. The use of an alloy of higher elastic modulus (CoCr) also caused the abutment deformation to increase. Abutment`s height and framework alloy influence the deformation of abutments of mandibular cantilevered implant-supported prosthesis. To cite this article:Suedam V, Capello SouzaEA, Moura MS, Jacques LB, Rubo JH. Effect of abutment`s height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis. Clin. Oral Impl. Res. 20, 2009; 196-200.doi: 10.1111/j.1600-0501.2008.01609.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Echinobothrium chisholmae n. sp. is described from Rhinobatos typus Bennett (Rhinobatidae), collected from Heron Island, Great Barrier Reef, Australia. E. chisholmae differs from all congeners in possessing 11 hooks in each dorsal and ventral group on the rostellum and groups of 3-6 hooklets on either side of the hooks. A single metacestode of E. chisholmae was collected from the decapod crustacean Penaeus longistylus Kubo. Yellow pigmentation of the cephalic peduncle in immature adults is caused by the accumulation of large vesicles in the distal cytoplasm of the tegument. The vesicles probably provide materials for spine formation. Ultrastructural examination of the rostellar musculature revealed that the muscles are stratified (striated-like), consisting of a periodic repetition of sarcomeres separated by perforated Z-like lines that are oblique to the long axes of the myofilaments.