963 resultados para Sensitivity and Specificity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess the sensitivity and specificity of catheter-drawn and peripheral blood cultures. Paired blood culture samples collected over a 44-month period from a 280 bed Brisbane metropolitan hospital were analysed, using standard clinical and microbiological criteria, to determine whether blood culture isolates represented true bacteraemias or contamination. Catheter-collected cultures had a specificity of 85% compared with 97% for peripheral cultures. In only two instances (0.2%) was the diagnosis of clinically significant bacteraemia made on the basis of catheter culture alone. This study concluded that catheter-collected samples are not a good test for true bacteraemia, and that peripheral. cultures are more reliable when the results of the paired cultures are discordant. (c) 2004 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Bone mineral density (BMD) may be associated with hearing loss in older adults. Demineralization of the cochlear capsule has been associated with hearing loss in those with Paget's disease of the bone and otosclerosis. Osteoporosis may also result in cochlear capsule demineralization. We hypothesized that lower hip BMD and lower heel ultrasound measurements would be associated with hearing loss in a population-based sample of 2,089 older black and white men and women. Bone parameters and hearing function were measured at the fourth clinical follow-up visit. Audiometric threshold testing was used to measure air- and bone-conduction hearing sensitivity. BMD of the hip and its subregions was measured using dual-energy X-ray absorptiometry. Calcaneal bone measurements [broadband ultrasound attenuation (BUA), speed of sound (SOS) and the quantitative ultrasound index (QUI)] were obtained using heel ultrasound. After adjusting for known hearing loss risk factors, no association was found between hearing and any of the bone measurements in whites and black women. In black men, however, lower hip BMD was associated with higher odds of hearing loss; for each standard deviation decrease in total hip BMD, the odds of hearing loss were 1.41 (95% confidence interval 1.08, 1.83), 1.39 (95% CI 1.07, 1.82) for femoral neck BMD and 1.65 (95% CI 1.26, 2.16) for trochanter BMD. Conductive hearing loss was associated with lower heel ultrasound measurements, though only among white men. The results of this study are mixed and inconclusive. Lower BMD of the hip and its subregions was associated with hearing loss among black men, but not among whites or black women. Lower measurements on heel ultrasound were associated with conductive hearing loss, though only among white men. These results suggest that axial and appendicular bone parameters may be modestly associated with hearing loss in older men, but not in women.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study aimed to investigate the acute effects of mild Traumatic Brain Injury (mTBI) on the performance of a finger tapping and word repetition dual task in order to determine working memory impairment in mTBI Sixty-four (50 male, 14 female) right-handed cases of mTBI and 26 (18 male and 8 female) right-handed cases of orthopaedic injuries were tested within 24 hours of injury. Patients with mTBI completed fewer correct taps in 10 seconds than patients with orthopaedic injuries, and female mTBI cases repeated fewer words. The size of the dual task decrement did not vary between groups. When added to a test battery including the Rapid Screen of Concussion (RSC; Comerford, Geffen, May, Medland T Geffen, 2002) and the Digit Symbol Substitution Test,finger tapping speed accounted for 1% of between groups variance and did not improve classification rates of male participants. While the addition of tapping rate did not improve the sensitivity and specificity of the RSC and DSST to mTBI in males, univariate analysis of motor performance in females indicated. that dual task performance might be diagnostic. An increase in female sample Size is warranted. These results confirm the view that there is a generalized slowing of processing ability following mTBI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Antigenic variation in Plasmodium falciparum erythrocyte membrane protein 1, caused by a switch in transcription of the encoding var gene, is an important feature of malaria. In this study, we quantified the relative abundance of var gene transcripts present in P. falciparum parasite clones using real-time reverse transcription-polymerase chain reaction (RT-PCR) and conventional RT-PCR combined with cloning and sequencing, with the aim of directly comparing the results obtained. When there was sufficient abundance of RNA for the real-time RT-PCR assay to be operating within the region of good reproducibility, RT-PCR and real-time RT-PCR tended to identify the same dominant transcript, although some transcript-specific issues were identified. When there were differences in the estimated relative amounts of minor transcripts, the RT-PCR assay tended to produce higher estimates than real-time RT-PCR. These results provide valuable information comparing RT-PCR and real-time RT-PCR analysis of samples with small quantities of RNA as might be expected in the analysis of field or clinical samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Objective: To describe the diagnostic accuracy and practical application of the Peter James Centre Falls Risk Assessment Tool (PJC-FRAT), a multidisciplinary falls risk screening and intervention deployment instrument. Methods: In phase 1, the accuracy of the PJC-FRAT was prospectively compared to a gold standard (the STRATIFY) on a cohort of subacute hospital patients (n = 122). In phase 2, the PJC-FRAT was temporally reassessed using a subsequent cohort (n = 316), with results compared to those of phase 1. Primary outcomes were falls (events), fallers (patients who fell), and hospital completion rates of the PJC-FRAT. Results: In phase 1, PJC-FRAT accuracy of identifying falters showed sensitivity of 73% (bootstrap 95% confidence interval CI = 55, 90) and specificity of 75% (95% CI = 66, 83), compared with the STRATIFY (cutoff >= 2/5) sensitivity of 77% (95% CI = 59, 92) and specificity of 51% (95% CI = 41, 61). This difference was not significant. In phase 2, accuracy of nursing staff using the PJC-FRAT was lower. PJC-FRAT completion rates varied among disciplines over both phases: nurses and physiotherapists, >= 90%; occupational therapists, >= 82%; and medical officers, >= 57%. Conclusion: The PJC-FRAT was practical and relatively accurate as a predictor of falls and a deployment instrument for falls prevention interventions, although continued staff education may be necessary to maintain its accuracy. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research adopts a resource allocation theoretical framework to generate predictions regarding the relationship between self-efficacy and task performance from two levels of analysis and specificity. Participants were given multiple trials of practice on an air traffic control task. Measures of task-specific self-efficacy and performance were taken at repeated intervals. The authors used multilevel analysis to demonstrate dynamic main effects, dynamic mediation and dynamic moderation. As predicted, the positive effects of overall task specific self-efficacy and general self-efficacy on task performance strengthened throughout practice. In line with these dynamic main effects, the effect of general self-efficacy was mediated by overall task specific self-efficacy; however this pattern emerged over time. Finally, changes in task specific self-efficacy were negatively associated with changes in performance at the within-person level; however this effect only emerged towards the end of practice for individuals with high levels of overall task specific self-efficacy. These novel findings emphasise the importance of conceptualising self-efficacy within a multi-level and multi-specificity framework and make a significant contribution to understanding the way this construct relates to task performance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Study examined the muldlevel reladonships among negadve affect Behavioural Inhibidon System (BIS) Sensidvit)' and performance. It also invesdgated whether the reladonship among these variables changed across pracdce. Pardcipants performed muldple trials of a simulated air traffic control task, A single measure of BIS was taken before pracdce, while negadve affect and performance were measured at repeated intervals. As expected, negadve affect was detrimental to performance at both a between-person and withinperson level, BIS was also found to be detrimental to performance. Contrary' to expectadons, the reladonship between BIS and performance was not mediated by overall levels of negadve affect. As predicted, the effects of overall levels of negadve affect and BIS strengthened across pracdce as pardcipants gained task knowledge and skill. The findings of this study are interpreted using resource allocadon theor}' and the implicadons for skiU acquisidon discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Determination of the subcellular location of a protein is essential to understanding its biochemical function. This information can provide insight into the function of hypothetical or novel proteins. These data are difficult to obtain experimentally but have become especially important since many whole genome sequencing projects have been finished and many resulting protein sequences are still lacking detailed functional information. In order to address this paucity of data, many computational prediction methods have been developed. However, these methods have varying levels of accuracy and perform differently based on the sequences that are presented to the underlying algorithm. It is therefore useful to compare these methods and monitor their performance. Results: In order to perform a comprehensive survey of prediction methods, we selected only methods that accepted large batches of protein sequences, were publicly available, and were able to predict localization to at least nine of the major subcellular locations (nucleus, cytosol, mitochondrion, extracellular region, plasma membrane, Golgi apparatus, endoplasmic reticulum (ER), peroxisome, and lysosome). The selected methods were CELLO, MultiLoc, Proteome Analyst, pTarget and WoLF PSORT. These methods were evaluated using 3763 mouse proteins from SwissProt that represent the source of the training sets used in development of the individual methods. In addition, an independent evaluation set of 2145 mouse proteins from LOCATE with a bias towards the subcellular localization underrepresented in SwissProt was used. The sensitivity and specificity were calculated for each method and compared to a theoretical value based on what might be observed by random chance. Conclusion: No individual method had a sufficient level of sensitivity across both evaluation sets that would enable reliable application to hypothetical proteins. All methods showed lower performance on the LOCATE dataset and variable performance on individual subcellular localizations was observed. Proteins localized to the secretory pathway were the most difficult to predict, while nuclear and extracellular proteins were predicted with the highest sensitivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effect of using different risk calculation tools on how general practitioners and practice nurses evaluate the risk of coronary heart disease with clinical data routinely available in patients' records. DESIGN: Subjective estimates of the risk of coronary heart disease and results of four different methods of calculation of risk were compared with each other and a reference standard that had been calculated with the Framingham equation; calculations were based on a sample of patients' records, randomly selected from groups at risk of coronary heart disease. SETTING: General practices in central England. PARTICIPANTS: 18 general practitioners and 18 practice nurses. MAIN OUTCOME MEASURES: Agreement of results of risk estimation and risk calculation with reference calculation; agreement of general practitioners with practice nurses; sensitivity and specificity of the different methods of risk calculation to detect patients at high or low risk of coronary heart disease. RESULTS: Only a minority of patients' records contained all of the risk factors required for the formal calculation of the risk of coronary heart disease (concentrations of high density lipoprotein (HDL) cholesterol were present in only 21%). Agreement of risk calculations with the reference standard was moderate (kappa=0.33-0.65 for practice nurses and 0.33 to 0.65 for general practitioners, depending on calculation tool), showing a trend for underestimation of risk. Moderate agreement was seen between the risks calculated by general practitioners and practice nurses for the same patients (kappa=0.47 to 0.58). The British charts gave the most sensitive results for risk of coronary heart disease (practice nurses 79%, general practitioners 80%), and it also gave the most specific results for practice nurses (100%), whereas the Sheffield table was the most specific method for general practitioners (89%). CONCLUSIONS: Routine calculation of the risk of coronary heart disease in primary care is hampered by poor availability of data on risk factors. General practitioners and practice nurses are able to evaluate the risk of coronary heart disease with only moderate accuracy. Data about risk factors need to be collected systematically, to allow the use of the most appropriate calculation tools.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The thesis will show how to equalise the effect of quantal noise across spatial frequencies by keeping the retinal flux (If-2) constant. In addition, quantal noise is used to study the effect of grating area and spatial frequency on contrast sensitivity resulting in the extension of the new contrast detection model describing the human contrast detection system as a simple image processor. According to the model the human contrast detection system comprises low-pass filtering due to ocular optics, addition of light dependent noise at the event of quantal absorption, high-pass filtering due to the neural visual pathways, addition of internal neural noise, after which detection takes place by a local matched filter, whose sampling efficiency decreases as grating area is increased. Furthermore, this work will demonstrate how to extract both the optical and neural modulation transfer functions of the human eye. The neural transfer function is found to be proportional to spatial frequency up to the local cut-off frequency at eccentricities of 0 - 37 deg across the visual field. The optical transfer function of the human eye is proposed to be more affected by the Stiles-Crawford -effect than generally assumed in the literature. Similarly, this work questions the prevailing ideas about the factors limiting peripheral vision by showing that peripheral optical acts as a low-pass filter in normal viewing conditions, and therefore the effect of peripheral optics is worse than generally assumed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study examined the use of non-standard parameters to investigate the visual field, with particular reference to the detection of glaucomatous visual field loss. Evaluation of the new perimetric strategy for threshold estimation - FASTPAC, demonstrated a reduction in the examination time of normals compared to the standard strategy. Despite an increased within-test variability the FASTPAC strategy produced a similar mean sensitivity to the standard strategy, reducing the effects of patient fatigue. The new technique of Blue-Yellow perimetry was compared to White-White perimetry for the detection of glaucomatous field loss in OHT and POAG. Using a database of normal subjects, confidence limits for normality were constructed to account for the increased between-subject variability with increase in age and eccentricity and for the greater variability of the Blue-Yellow field compared to the White-White field. Effects of individual ocular media absorption had little effect on Blue-Yellow field variability. Total and pattern probability analysis revealed five of 27 OHTs to exhibit Blue-Yellow focal abnormalities; two of these patients subsequently developed White-White loss. Twelve of the 24 POAGs revealed wider and/or deeper Blue-Yellow loss compared with the White-White field. Blue-Yellow perimetry showed good sensitivity and specificity characteristics, however, lack of perimetric experience and the presence of cataract influenced the Blue-Yellow visual field and may confound the interpretation of Blue-Yellow visual field loss. Visual field indices demonstrated a moderate relationship to the structural parameters of the optic nerve head using scanning laser tomography. No abnormalities in Blue-Yellow or Red-Green colour CS was apparent for the OHT patients. A greater vulnerability of the SWS pathway in glaucoma was demonstrated using Blue-Yellow perimetry however predicting which patients may benefit from B-Y perimetric examination is difficult. Furthermore, cataract and the extent of the field loss may limit the extent to which the integrity of the SWS channels can be selectively examined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Yellow filters are sometimes recommended to people with low vision. Our aim was investigate the effects of three commercial yellow filters on visual acuity and contrast sensitivity (with and without glare) and reading (without glare) under conditions of forward light scatter (FLS). Method Fifty-five healthy subjects were assessed with Corning Photochromic Filters (CPFs) 450, 511 and 527 and a filter producing FLS. The effects on log MAR visual acuity, Pelli–Robson contrast sensitivity with and without glare, and reading (measured with MNRead charts) without glare were determined. Results Statistically significant differences were found between the overall effect of glare and between CPFs for visual acuity and contrast sensitivity. A gradual decline in visual acuity, contrast sensitivity and reading with increasing CPF absorption was noted. Conclusion Effects of CPF450, 511, 527 on visual acuity, contrast sensitivity and reading under conditions of FLS were negative but not clinically significant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: We have adapted the existing , optometry diabetic retinopathy screening pathway and software , so that it can be used for wet AMD fast track referral. Purpose: To compare the conventional, optometry wet AMD fast track referral service using FAX transmission, with a teleophthalmology service using colour fundus photography transmitted to a central retinal grading centre. Method: 40 optometry practices involved in diabetic retinopathy screening were enrolled and had modified computer software installed. Referrals were made by conventional fast track FAX to the macular clinic, and patients were photographed by the optometrist and images transmitted to a central grading centre Results of the two pathways were compared in terms of 1)speed of diagnosis and 2)sensitivity and specificity of diagnosis of wet AMD. Results: Over a ten month period, 62 consecutive patients were referred. The mean time for conventional pathway was 20.8 days (range 3-34),and for new teleophthalmology pathway was 6.9 days (range 1-13). Sensitivity of technician grading of images was 96%, Specificity 53%, and consultant ophthalmologist was sensitivity 96%, specificiity 87%. The technician showed a learning effect with specificity increasing from 30.7% for first 31 patient cohort, to 70.6% for the second cohort. One patient had images that could not be graded. Conclusion: Rapid referral of wet AMD cases by optometrists using modified diabetic retinopathy screening software, allows fast and accurate diagnosis, and may reduce unnecessary referrals. Retinal grading technicians can be trained to grade wet AMD images.