986 resultados para Schleiermacher, Friedrich Ernst Daniel
Resumo:
The electron Monte Carlo (eMC) dose calculation algorithm in Eclipse (Varian Medical Systems) is based on the macro MC method and is able to predict dose distributions for high energy electron beams with high accuracy. However, there are limitations for low energy electron beams. This work aims to improve the accuracy of the dose calculation using eMC for 4 and 6 MeV electron beams of Varian linear accelerators. Improvements implemented into the eMC include (1) improved determination of the initial electron energy spectrum by increased resolution of mono-energetic depth dose curves used during beam configuration; (2) inclusion of all the scrapers of the applicator in the beam model; (3) reduction of the maximum size of the sphere to be selected within the macro MC transport when the energy of the incident electron is below certain thresholds. The impact of these changes in eMC is investigated by comparing calculated dose distributions for 4 and 6 MeV electron beams at source to surface distance (SSD) of 100 and 110 cm with applicators ranging from 6 x 6 to 25 x 25 cm(2) of a Varian Clinac 2300C/D with the corresponding measurements. Dose differences between calculated and measured absolute depth dose curves are reduced from 6% to less than 1.5% for both energies and all applicators considered at SSD of 100 cm. Using the original eMC implementation, absolute dose profiles at depths of 1 cm, d(max) and R50 in water lead to dose differences of up to 8% for applicators larger than 15 x 15 cm(2) at SSD 100 cm. Those differences are now reduced to less than 2% for all dose profiles investigated when the improved version of eMC is used. At SSD of 110 cm the dose difference for the original eMC version is even more pronounced and can be larger than 10%. Those differences are reduced to within 2% or 2 mm with the improved version of eMC. In this work several enhancements were made in the eMC algorithm leading to significant improvements in the accuracy of the dose calculation for 4 and 6 MeV electron beams of Varian linear accelerators.
Resumo:
Saccular intracranial aneurysms are balloon-like dilations of the intracranial arterial wall; their hemorrhage commonly results in severe neurologic impairment and death. We report a second genome-wide association study with discovery and replication cohorts from Europe and Japan comprising 5,891 cases and 14,181 controls with approximately 832,000 genotyped and imputed SNPs across discovery cohorts. We identified three new loci showing strong evidence for association with intracranial aneurysms in the combined dataset, including intervals near RBBP8 on 18q11.2 (odds ratio (OR) = 1.22, P = 1.1 x 10(-12)), STARD13-KL on 13q13.1 (OR = 1.20, P = 2.5 x 10(-9)) and a gene-rich region on 10q24.32 (OR = 1.29, P = 1.2 x 10(-9)). We also confirmed prior associations near SOX17 (8q11.23-q12.1; OR = 1.28, P = 1.3 x 10(-12)) and CDKN2A-CDKN2B (9p21.3; OR = 1.31, P = 1.5 x 10(-22)). It is noteworthy that several putative risk genes play a role in cell-cycle progression, potentially affecting the proliferation and senescence of progenitor-cell populations that are responsible for vascular formation and repair.
Resumo:
Am 10. September 2010 fand in Bern die erste Schweizerische Tagung für Zivilverfahrensrecht des Instituts für Internationales Privatrecht und Verfahrensrecht der Universität Bern statt. Die Tagung mit dem Titel "Internationaler Zivilprozess 2011" befasste sich mit dem Zusammenspiel der am 1.1.2011 in Kraft tretenden neuen oder revidierten Erlasse (ZPO, revLugÜ, und revSchKG) im Rahmen des internationalen Zivilprozesses. Der Tagungsband enthält auf den Tagungsvorträgen basierende Beiträge namhafter Autoren zu aktuellen und praxisrelevanten Themen des neuen internationalen Zivilprozesses, namentlich zum neuen Arrestrecht, zur Behandlung von Zustellungsmängeln unter dem revLugÜ, zum Zahlungsbefehl im Lichte der revLugÜ-Zuständigkeiten, zur vollstreckbaren öffentliche Urkunde sowie zur Rechtshängigkeit und zur Streitgenossenschaft im internationalen Verhältnis. Der Tagungsband "Internationaler Zivilprozess 2011" eröffnet eine neue Schriftenreihe zum Internationalen Privatrecht und Verfahrensrecht.
Resumo:
Recently, the new high definition multileaf collimator (HD120 MLC) was commercialized by Varian Medical Systems providing high resolution in the center section of the treatment field. The aim of this work is to investigate the characteristics of the HD120 MLC using Monte Carlo (MC) methods.
Resumo:
To evaluate the role of postoperative radiotherapy (RT) in Merkel cell carcinoma (MCC).
Resumo:
Thoracic endovascular aortic repair (TEVAR) has emerged as a promising therapeutic alternative to conventional open aortic replacement but it requires suitable proximal and distal landing zones for stent-graft anchoring. Many aortic pathologies affect in the immediate proximity of the left subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre has the potential for immediate and delayed neurological and vascular symptoms. Some authors, therefore, propose prophylactic revascularisation of the LSA by transposition or bypass, while others suggest prophylactic revascularisation only under certain conditions, and still others see no requirement for prophylactic revascularisation in anticipation of LSA ostium coverage. In this review about LSA revascularisation in TEVAR patients with coverage of the LSA, we searched the electronic databases MEDLINE and EMBASE historically until the end date of May 2010 with the search terms left subclavian artery, covering, endovascular, revascularisation and thoracic aorta. We have gathered the most complete scientific evidence available used to support the various concepts to deal with this issue. After a review of the current available literature, 23 relevant articles were found, where we have identified and analysed three basic treatment concepts for LSA revascularisation in TEVAR patients (prophylactic, conditional prophylactic and no prophylactic LSA revascularisation). The available evidence supports prophylactic revascularisation of the LSA before ESG LSA coverage when preoperative imaging reveals abnormal supra-aortic vascular anatomy or pathology. We further conclude that elective patients undergoing planned coverage of the LSA during TEVAR should receive prophylactic LSA transposition or LSA-to-left-common-carotid-artery (LCCA) bypass surgery to prevent severe neurological complications, such as paraplegia or brain stem infarction.
Resumo:
The repair of critical-sized bony defects remains a challenge in the fields of implantology, maxillofacial surgery and orthopaedics. As an alternative bone-defect filler to autologous bone grafts, deproteinized bovine bone (DBB) is highly osteoconductive and clinically now widely used. However, this product suffers from the disadvantage of not being intrinsically osteoinductive. In the present study, this property was conferred by coating DBB with a layer of calcium phosphate into which bone morphogenetic protein 2 (BMP-2) was incorporated. Granules of DBB bearing a coating-incorporated depot of BMP-2--together with the appropriate controls (DBB bearing a coating but no BMP-2; uncoated DBB bearing adsorbed BMP-2; uncoated DBB bearing no BMP-2)--were implanted subcutaneously in rats. Five weeks later, the implants were withdrawn for a histomorphometric analysis of the volume densities of (i) bone, (ii) bone marrow, (iii) foreign-body giant cells and (iv) fibrous capsular tissue. Parameters (i) and (ii) were highest, whilst parameters (iii) and (iv) were lowest in association with DBB bearing a coating-incorporated depot of BMP-2. Hence, this mode of functionalization not only confers DBB with the property of osteoinductivity but also improves its biocompatibility--thus dually enhancing its clinical potential in the repair of bony defects.
Resumo:
Am 9. September 2011 führte das Institut für Verfahrensrecht und Internationales Privatrecht (CIVPRO) der Universität Bern in bewährter Zusammenarbeit mit der schweizerischen SchKG-Vereinigung die zweite Schweizer Tagung für Internationales Zivilverfahrensrecht durch. Im Mittelpunkt der Tagung standen vorsorgliche Massnahmen im internationalen Kontext vor dem Hintergrund der neuesten Entwicklungen, namentlich (aber nicht nur) des neuen Lugano-Übereinkommens. Der Tagungsband enthält die auf den Vorträgen basierenden, überarbeiteten und erweiterten Beiträge namhafter Autorinnen und Autoren zum vorsorglichen Rechtsschutz im neuen IZPR (Pascal Grolimund). Besondere Aufmerksamkeit gilt dem neuen Arrestrecht sowohl im als auch ausserhalb des Anwendungsbereichs des Lugano-Übereinkommens (Richard Gassmann und Jürg Roth). Ebenso enthält der Band Beiträge zu den Sicherungsmassnahmen in der Realvollstreckung (Daniel Staehelin) sowie zur Anerkennung ausländischer vorsorglicher Massnahmen (Isabelle Chabloz).