912 resultados para SHOULDER INSTABILITY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Robotic exoskeletons can be used to study and treat patients with neurological impairments. They can guide and support the human limb over a large range of motion, which requires that the movement trajectory of the exoskeleton coincide with the one of the human arm. This is straightforward to achieve for rather simple joints like the elbow, but very challenging for complex joints like the human shoulder, which is comprised by several bones and can exhibit a movement with multiple rotational and translational degrees of freedom. Thus, several research groups have developed different shoulder actuation mechanism. However, there are no experimental studies that directly compare the comfort of two different shoulder actuation mechanisms. In this study, the comfort and the naturalness of the new shoulder actuation mechanism of the ARMin III exoskeleton are compared to a ball-and-socket-type shoulder actuation. The study was conducted in 20 healthy subjects using questionnaires and 3D-motion records to assess comfort and naturalness. The results indicate that the new shoulder actuation is slightly better than a ball-and-socket-type actuation. However, the differences are small, and under the tested conditions, the comfort and the naturalness of the two tested shoulder actuations do not differ a lot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bovine papillomavirus 1 (BPV-1) is a well recognized etiopathogenetic factor in a cancer-like state in horses, namely equine sarcoid disease. Nevertheless, little is known about BPV-1-mediated cell transforming effects. It was shown that BPV-1 triggers genomic instability through DNA hypomethylation and oxidative stress. In the present study, we further characterized BPV-1-positive fibroblasts derived from sarcoid tumors. The focus was on cancer-like features of sarcoid-derived fibroblasts, including cell cycle perturbation, comprehensive DNA damage analysis, end-replication problem, energy metabolism and oncogene-induced premature senescence. The S phase of the cell cycle, polyploidy events, DNA double strand breaks (DSBs) and DNA single strand breaks (SSBs) were increased in BPV-1-positive cells compared to control fibroblasts. BPV-1-mediated oxidative stress may contribute to telomere dysfunction in sarcoid-derived fibroblasts. Loss of mitochondrial membrane potential and concurrent elevation in intracellular ATP production may be a consequence of changes in energy-supplying pathways in BPV-1-positive cells which is also typical for cancer cells. Shifts in energy metabolism may support rapid proliferation in cells infected by BPV-1. Nevertheless, sarcoid-derived fibroblasts representing a heterogeneous cell fraction vary in some aspects of metabolic phenotype due to a dual role of BPV-1 in cell transformation and oncogene-induced premature senescence. This was shown with increased senescence-associated β-galactosidase (SA-β-gal) activity. Taken together, metabolic phenotypes in sarcoid-derived fibroblasts are plastic, which are similar to greater plasticity of cancer tissues than normal tissues.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND & AIMS Sporadic pancreatic neuroendocrine tumors (pNETs) are rare and genetically heterogeneous. Chromosome instability (CIN) has been detected in pNETs from patients with poor outcomes, but no specific genetic factors have been associated with CIN. Mutations in death domain-associated protein gene (DAXX) or ATR-X gene (ATRX) (which both encode proteins involved in chromatin remodeling) have been detected in 40% of pNETs, in association with activation of alternative lengthening of telomeres. We investigated whether loss of DAXX or ATRX, and consequent alternative lengthening of telomeres, are related to CIN in pNETs. We also assessed whether loss of DAXX or ATRX is associated with specific phenotypes of pNETs. METHODS We collected well-differentiated primary pNET samples from 142 patients at the University Hospital Zurich and from 101 patients at the University Hospital Bern (both located in Switzerland). Clinical follow-up data were obtained for 149 patients from general practitioners and tumor registries. The tumors were reclassified into 3 groups according to the 2010 World Health Organization classification. Samples were analyzed by immunohistochemistry and telomeric fluorescence in situ hybridization. We correlated loss of DAXX, or ATRX, expression, and activation of alternative lengthening of telomeres with data from comparative genomic hybridization array studies, as well as with clinical and pathological features of the tumors and relapse and survival data. RESULTS Loss of DAXX or ATRX protein and alternative lengthening of telomeres were associated with CIN in pNETs. Furthermore, loss of DAXX or ATRX correlated with tumor stage and metastasis, reduced time of relapse-free survival, and decreased time of tumor-associated survival. CONCLUSIONS Loss of DAXX or ATRX is associated with CIN in pNETs and shorter survival times of patients. These results support the hypothesis that DAXX- and ATRX-negative tumors are a more aggressive subtype of pNET, and could lead to identification of strategies to target CIN in pancreatic tumors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genetic instability in mammalian cells can occur by many different mechanisms. In the absence of exogenous sources of DNA damage, the DNA structure itself has been implicated in genetic instability. When the canonical B-DNA helix is naturally altered to form a non-canonical DNA structure such as a Z-DNA or H-DNA, this can lead to genetic instability in the form of DNA double-strand breaks (DSBs) (1, 2). Our laboratory found that the stability of these non-B DNA structures was different in mammals versus Escherichia coli (E.coli) bacteria (1, 2). One explanation for the difference between these species may be a result of how DSBs are repaired within each species. Non-homologous end-joining (NHEJ) is primed to repair DSBs in mammalian cells, while bacteria that lack NHEJ (such as E.coli), utilize homologous recombination (HR) to repair DSBs. To investigate the role of the error-prone NHEJ repair pathway in DNA structure-induced genetic instability, E.coli cells were modified to express genes to allow for a functional NHEJ system under different HR backgrounds. The Mycobacterium tuberculosis NHEJ sufficient system is composed of Ku and Ligase D (LigD) (3). These inducible NHEJ components were expressed individually and together in E.coli cells, with or without functional HR (RecA/RecB), and the Z-DNA and H-DNA-induced mutations were characterized. The Z-DNA structure gave rise to higher mutation frequencies compared to the controls, regardless of the DSB repair pathway(s) available; however, the type of mutants produced after repair was greatly dictated on the available DSB repair system, indicated by the shift from 2% large-scale deletions in the total mutant population to 24% large-scale deletions when NHEJ was present (4). This suggests that NHEJ has a role in the large deletions induced by Z-DNA-forming sequences. H-DNA structure, however, did not exhibit an increase in mutagenesis in the newly engineered E.coli environment, suggesting the involvement of other factors in regulating H-DNA formation/stability in bacterial cells. Accurate repair by established DNA DSB repair pathways is essential to maintain the stability of eukaryotic and prokaryotic genomes and our results suggest that an error-prone NHEJ pathway was involved in non-B DNA structure-induced mutagenesis in both prokaryotes and eukaryotes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot-supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end-effector-based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: First, to determine an average and maximum displacement of the shoulder relative to isocenter over the course of treatment. Second, to establish the dosimetric effect of shoulder displacements relative to correct isocenter alignment on the dose delivered to the target and the surrounding structures for head and neck cancer patients. Method and Materials: The frequency of shoulder shifts of various magnitudes relative to isocenter was assessed for 4 patients using image registration software. The location of the center of the right and left humeral head relative to isocenter (usually C2) was found daily from CT on rails scans, and was compared to the location of the humeral heads relative to isocenter on the initial simulation CT. Three Baseline head and neck IMRT and SmartArc plans were generated in Pinnacle based on simulation CTs. The CT datasets (external contour and boney structures) were then modified to represent shifts of the shoulder (relative to isocenter) between 3 mm and 15 mm in the SI, AP, and LR directions. The initial plans were recalculated on the image sets with shifted shoulders. Results: On average, shoulder variation was 2-5 mm in each direction, although displacements of over 1 cm in the inferior and posterior directions occurred. Shoulder shifts induced perturbations in the dose distribution, although generally only for large shifts. Most substantially, large, superior shifts resulted in coverage loss by the 95% isodose line for targets in the lower neck. Inferior shifts elevated the dose to the brachial plexus by 0.6-4.1 Gy. SmartArc plans showed similar loss of target coverage as IMRT plans. Conclusions: The position of the shoulder can have an impact on target coverage and critical structure dose. Shoulder position may need to be considered for setup of head and neck patients depending on target location.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To investigate the hypothesis that increased malignant potential correlates with increased levels of genetic instability, the following parameters of instability were measured: (1) spontaneous mutation rates for ouabain resistance in murine cell lines of different malignant potentials, (2) the background prevalence of 6-thioguanine (6-TG) resistance in clone 4 (highly metastatic) and clone 19 (poorly metastatic) of the K1735 murine melanoma, (3) the prevalence of ouabain resistant variants in three murine cell lines and their variants after exposure to the mutagen MNNG, (4) the rate of generation of major karyotypic abnormalities in B16 F1 (poorly metastatic) and B16 F10 (highly metastatic) murine melanoma, and (5) analysis of the G-banded karyotypes of cloned B16 F1 and B16 F10 melanoma.^ No correlation of increased spontaneous mutation rates with increased malignant potential was found in repeated experiments with three murine cell lines and their variants of different malignant potential. The background prevalence of g-TG resistance was not significantly different for the poorly and highly metastatic clones of K1735 melanoma. The studies with MNNG-induced mutation showed no increased sensitivity of the highly metastatic variants of the three murine cell lines to mutagenesis. Neither did the rate of generation of major karyotypic abnormalities correlate with malignant potential. However, certain karyotypic differences were demonstrated after G-banding of the B16 F1 and F10 melanomas.^ One hypothesis which is consistent with these results is that the rate of generation of genetic abnormalities need not be strongly related to the degree of malignant potential. An increased prevalence of genetic changes may merely reflect the accumulation of abnormalities while their rate of production remains constant. The presence of specific nonrandom changes likely is the main determinant of malignant potential rather than the rate of production of random changes. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The critical shoulder angle (CSA) is an indicator of degenerative shoulder pathologies. CSAs above 35° are associated with degenerative rotator cuff disease, whereas values below 30° are common in osteoarthritis of the glenohumeral joint. Measurements are usually performed on radiographs; however, no data have been reported regarding the reliability of CT scan measurements between different readers or the reproducibility of measurements from radiographs to CT scans. The purpose of our study was to clarify whether CSA measurements on radiographs and CT scans of the same patients show similar values. MATERIALS AND METHODS CSA measurements of 60 shoulders (59 patients) were performed on radiographs and multiplanar reconstructions of corresponding CT scans. Inter-reader reliability and inter-method correlation were calculated. RESULTS The mean discrepancy between readers was only 0.2° (SD ±1.0°) on radiographs. CT scan measurements showed a mean discrepancy of 0.3° (SD ±1.2°). The inter-reader reliability was 0.993 for radiographs and 0.989 for CT scans. There was a very strong inter-method correlation between the CSA measured on radiographs and CT scans (Spearman's rho = 0.974). The mean differences between angles on radiographs and CT measurements were -0.05° (SD ±1.2°) and 0.1° (SD ±1.2°), respectively. CONCLUSION Measurements of the CSA on anterior-posterior radiographs and CT scans are highly correlated, and inter-modality differences are negligible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The pathogenesis of full-thickness tears of the rotator cuff remains unclear. Apart from age and trauma, distinct scapular morphologies have been found to be associated with rotator cuff disease. The purpose of the present study was to evaluate whether a score formed using these established risk factors was able to predict the presence of a rotator cuff tear reliably. METHODS We retrospectively assessed a consecutive series of patients with a minimal age of 40 years old, who had true antero-posterior (AP) radiographs of their shoulders, as well as a magnetic resonance (MR) gadolinium-arthrography, between January and December 2011. In all of these patients, the critical shoulder angle (CSA) was determined, and MR images were assessed for the presence of rotator cuff tears. Additionally, the patients' charts were reviewed to obtain details of symptom onset. Based on these factors, the so-called rotator cuff tear (RCT) score was calculated. RESULTS Patients with full-thickness RCTs were significantly older and had significantly larger CSAs than patients with intact rotator cuffs. Multiple logistic regression, using trauma, age and CSA as independent variables, revealed areas under the curve (AUCs) for trauma of 0.55, for age of 0.65 and for CSA of 0.86. The combination of all three factors was the most powerful predictor, with an AUC of 0.92. CONCLUSION Age, trauma and the CSA can accurately predict the presence of a posterosuperior RCT. LEVEL OF EVIDENCE Level IV. Case series with no comparison groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To assess patients' outcomes after subacromial or glenohumeral injections based on the degree of lateral extension of the acromion. METHODS 307 patients were prospectively included after therapeutic fluoroscopy-guided subacromial (n = 148) or glenohumeral (n = 159) injections with anaesthetic and long-acting corticosteroids. Pre- and post-injection outcomes at 1 week and 1 month were obtained using the 11-point numerical rating scale (NRS) for pain. Lateral extension of the acromion was quantified and categorized by the critical shoulder angle (CSA) and the acromion index (AI) on anteroposterior conventional radiographs. RESULTS Patients' outcomes at 1 week and 1 month were significantly improved (p < 0.001) compared to baseline for subacromial and glenohumeral injection patients. Patients with a CSA <35° showed significantly higher pain reduction 1 month after subacromial injection compared to patients with a CSA >35° (4.2 ± 2.6 vs. 3.2 ± 3.0, p = 0.04). A significant difference in the 1-month NRS change in pain scores is noted for smaller AIs after subacromial injection (4.3 ± 2.8 vs. 2.6 ± 2.9; p = 0.01). No significant association was noted between clinical outcome and the lateral extension of the acromion after glenohumeral joint injections. CONCLUSIONS A short lateral extension of the acromion was associated with better clinical outcomes in subacromial injection patients but not in glenohumeral injection patients. KEY POINTS • Patients' outcomes at 1 month improved significantly compared to baseline for subacromial injections. • Patients' outcomes at 1 month improved significantly compared to baseline for glenohumeral injections. • Short acromial lateralization was associated with better clinical outcome after subacromial injection. • The acromial lateralization was not associated with clinical outcome after glenohumeral injection.