989 resultados para SCREENING ACCURACY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study evaluated the anti-inflammatory and analgesic properties of Agave sisalana Perrine in classic models of inflammation and pain. The hexanic fraction of A. sisalana (HFAS) was obtained by acid hydrolysis followed by hexanic reflux. Anti-inflammatory properties were examined in three acute mouse models (xylene ear oedema, hind paw oedema and pleurisy) and a chronic mouse model (granuloma cotton pellet). The antinociceptive potential was evaluated in chemical (acetic-acid) and thermal (tail-flick and hot-plate test) models of pain. When given orally, HFAS (5, 10, 25 and 50 mg/kg) reduced ear oedema (p < 0.0001; 52%, 71%, 62% and 42%, respectively). HFAS also reduced hind paw oedema at doses of 10 mg/kg and 25 mg/kg (p < 0.05; 42% and 58%, respectively) and pleurisy at doses of 10 mg/kg and 25 mg/kg (41% and 50%, respectively). In a chronic model, HFAS reduced inflammation by 46% and 58% at doses of 10 mg/kg and 25 mg/kg, respectively. Moreover, this fraction showed analgesic properties against the abdominal writhing in an acetic acid model (at doses of 5-25 mg/kg) with inhibitory rates of 24%, 54% and 48%. The HFAS also showed an increased latency time in the hot-plate (23% and 28%) and tail-flick tests (61% and 66%) for the 25 mg/kg and 50 mg/kg doses, respectively. These results suggest that HFAS has anti-inflammatory and analgesic properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malposition of the acetabular component during hip arthroplasty increases the occurrence of impingement, reduces range of motion, and increases the risk of dislocation and long-term wear. To prevent malpositioned hip implants, an increasing number of computer-assisted orthopaedic systems have been described, but their accuracy is not well established. The purpose of this study was to determine the reproducibility and accuracy of conventional versus computer-assisted techniques for positioning the acetabular component in total hip arthroplasty. Using a lateral approach, 150 cups were placed by 10 surgeons in 10 identical plastic pelvis models (freehand, with a mechanical guide, using computer assistance). Conditions for cup implantations were made to mimic the operating room situation. Preoperative planning was done from a computed tomography scan. The accuracy of cup abduction and anteversion was assessed with an electromagnetic system. Freehand placement revealed a mean accuracy of cup anteversion and abduction of 10 degrees and 3.5 degrees, respectively (maximum error, 35 degrees). With the cup positioner, these angles measured 8 degrees and 4 degrees (maximum error, 29.8 degrees), respectively, and using computer assistance, 1.5 degrees and 2.5 degrees degrees (maximum error, 8 degrees), respectively. Computer-assisted cup placement was an accurate and reproducible technique for total hip arthroplasty. It was more accurate than traditional methods of cup positioning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Participation is a key indicator of the potential effectiveness of any population-based intervention. Defining, measuring and reporting participation in cancer screening programmes has become more heterogeneous as the number and diversity of interventions have increased, and the purposes of this benchmarking parameter have broadened. This study, centred on colorectal cancer, addresses current issues that affect the increasingly complex task of comparing screening participation across settings. Reports from programmes with a defined target population and active invitation scheme, published between 2005 and 2012, were reviewed. Differences in defining and measuring participation were identified and quantified, and participation indicators were grouped by aims of measure and temporal dimensions. We found that consistent terminology, clear and complete reporting of participation definition and systematic documentation of coverage by invitation were lacking. Further, adherence to definitions proposed in the 2010 European Guidelines for Quality Assurance in Colorectal Cancer Screening was suboptimal. Ineligible individuals represented 1% to 15% of invitations, and variable criteria for ineligibility yielded differences in participation estimates that could obscure the interpretation of colorectal cancer screening participation internationally. Excluding ineligible individuals from the reference population enhances comparability of participation measures. Standardised measures of cumulative participation to compare screening protocols with different intervals and inclusion of time since invitation in definitions are urgently needed to improve international comparability of colorectal cancer screening participation. Recommendations to improve comparability of participation indicators in cancer screening interventions are made.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spatial data on species distributions are available in two main forms, point locations and distribution maps (polygon ranges and grids). The first are often temporally and spatially biased, and too discontinuous, to be useful (untransformed) in spatial analyses. A variety of modelling approaches are used to transform point locations into maps. We discuss the attributes that point location data and distribution maps must satisfy in order to be useful in conservation planning. We recommend that before point location data are used to produce and/or evaluate distribution models, the dataset should be assessed under a set of criteria, including sample size, age of data, environmental/geographical coverage, independence, accuracy, time relevance and (often forgotten) representation of areas of permanent and natural presence of the species. Distribution maps must satisfy additional attributes if used for conservation analyses and strategies, including minimizing commission and omission errors, credibility of the source/assessors and availability for public screening. We review currently available databases for mammals globally and show that they are highly variable in complying with these attributes. The heterogeneity and weakness of spatial data seriously constrain their utility to global and also sub-global scale conservation analyses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparative effectiveness research (CER) allows evidence to be evaluated on the effectiveness, benefits, and detriments of management options, diagnostic tests, or ways to deliver health care. This process can be achieved in different ways, such as with well-designed randomized controlled trials or by meta-analyses. Several medical subspecialties are increasingly using CER, but CER remains underused by the neurosurgical community. Meta-analysis is a highly accurate method that permits results from multiple well-designed research studies to be quantitatively compared. Meta-analysis can be performed in many settings, such as the evaluation of treatment or of a diagnostic test or prognostic factor. Meta-analyses of randomized controlled treatment trials are well known, but there is a paucity of papers describing the ways to perform a meta-analysis of a diagnostic test. The aim of this paper is to improve neurosurgeons' familiarity with the meta-analysis of diagnostic test accuracy by describing and detailing each stage leading to publication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Context: The debate about the balance of risks and benefits of mammography screening has prompted a comprehensive review by an independent panel in the UK. However, the panel's remit did not cover the important economic dimension of breast cancer screening. Methods: The life histories of two cohort studies of 50-year-old women, who would be eligible within the National Health Service (NHS) breast screening programme (NHSBSP), were simulated over 35 years, using a life table approach. One cohort participant was offered screening at age 50 and triennially thereafter until age 70, assuming 75% attendance, while the other received no screening. Based on the findings from the panel's report, the cost-effectiveness of the NHSBSP was assessed for various scenarios of screening effect on breast cancer incidence (base case scenario: screening advances diagnosis by 5 years; 10% incidence reduction after screening stops).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Chemotherapeutic drug resistance is one of the major causes for treatment failure in high-risk neuroblastoma (NB), the most common extra cranial solid tumor in children. Poor prognosis is typically associated with MYCN amplification. Here, we utilized a loss-of-function kinome-wide RNA interference screen to identify genes that cause cisplatin sensitization. We identified fibroblast growth factor receptor 2 (FGFR2) as an important determinant of cisplatin resistance. Pharmacological inhibition of FGFR2 confirmed the importance of this kinase in NB chemoresistance. Silencing of FGFR2 sensitized NB cells to cisplatin-induced apoptosis, which was regulated by the downregulation of the anti-apoptotic proteins BCL2 and BCLXL. Mechanistically, FGFR2 was shown to activate protein kinase C-δ to induce BCL2 expression. FGFR2, as well as the ligand fibroblast growth factor-2, were consistently expressed in primary NB and NB cell lines, indicating the presence of an autocrine loop. Expression analysis revealed that FGFR2 correlates with MYCN amplification and with advanced stage disease, demonstrating the clinical relevance of FGFR2 in NB. These findings suggest a novel role for FGFR2 in chemoresistance and provide a rational to combine pharmacological inhibitors against FGFR2 with chemotherapeutic agents for the treatment of NB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many patients with Chagas disease live in remote communities that lack both equipment and trained personnel to perform a diagnosis by conventional serology (CS). Thus, reliable tests suitable for use under difficult conditions are required. In this study, we evaluated the ability of personnel with and without laboratory skills to perform immunochromatographic (IC) tests to detect Chagas disease at a primary health care centre (PHCC). We examined whole blood samples from 241 patients and serum samples from 238 patients. Then, we calculated the percentage of overall agreement (POA) between the two groups of operators for the sensitivity (S), specificity (Sp) and positive (PPV) and negative (NPV) predictive values of IC tests compared to CS tests. We also evaluated the level of agreement between ELISAs and indirect haemagglutination (IHA) tests. The readings of the IC test results showed 100% agreement (POA = 1). The IC test on whole blood showed the following values: S = 87.3%; Sp = 98.8%; PPV = 96.9% and NPV = 95.9%. Additionally, the IC test on serum displayed the following results: S = 95.7%; Sp = 100%; PPV = 100% and NPV = 98.2%. Using whole blood, the agreement with ELISA was 96.3% and the agreement with IHA was 94.1%. Using serum, the agreement with ELISA was 97.8% and the agreement with IHA was 96.6%. The IC test performance with serum samples was excellent and demonstrated its usefulness in a PHCC with minimal equipment. If the IC test S value and NPV with whole blood are improved, then this test could also be used in areas lacking laboratories or specialised personnel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To compare the results of rapid PCR screening for MRSA using the GeneXpert system with those of cultures in an outbreak setting. Methods: GeneXpert was used for screening MRSA in nose, throat, groin, and other clinical samples during a 6-month period. Samples were performed using a double-swab transystem. When >1 sample was found positive in a screening set, all second swabs of the set were analysed by culture. Results: From June to October 2009, 7568 rapid tests were performed, among which 432 (5.7%) were positive (nose: 149/2090, 7.1%; throat: 98/2078, 4.7%; groin: 152/2080, 7.3%; urine: 14/1090, 1.3%; wounds: 18/150, 12%; and others:1/27, 3.7%), and 84 (1.1%) were invalid. A total of 1517 samples were analyzed by both rapid PCR and culture. Rapid tests had a sensitivity of 0.896 compared to cultures, a specificity of 0.769, a PPV of 0.763, and a NPV of 0.899. The rapid test was found to be less sensitive in throat samples (0.81) than in nose or inguinal samples (0.93 for both). In 32/192 (16%) patients a positive rapid PCR result was not confirmed by culture, despite several subsequent screening samples in some patients. Cycle threshold (Ct) for SCCmec of these PCR positive reactions were all >30. Conclusions: GeneXpert MRSA was found to be suitable for the rapid detection in nose, inguinal, and throat samples, however with a lower sensitivity in the later. Negative cultures in 16% of our PCR-positive patients raised the question of false positivity or higher sensitivity of GeneXpert. Further work is needed to investigate these cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The screening of vascular pathologies in physician offices starts with precise medical history and clinical exam. Tools like the Edinburgh Claudication Questionnaire for the peripheral artery disease or the Wells score for the probability of a thromboembolic event are useful. The measure of the ankle brachial index, the D-dimers or any other biological screening are complementary. In the presence of pathological features, it is recommended to organise a specialised consultation in order to precise diagnosis, treatment and follow-up. The screening of a vascular disease is interesting not only for the management of local symptoms, but also for the associated systemic pathologies to provide a preventive medicine of good quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of mucocutaneous leishmaniasis (MCL) is hampered by the absence of a gold standard. An accurate diagnosis is essential because of the high toxicity of the medications for the disease. This study aimed to assess the ability of polymerase chain reaction (PCR) to identify MCL and to compare these results with clinical research recently published by the authors. A systematic literature review based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA Statement was performed using comprehensive search criteria and communication with the authors. A meta-analysis considering the estimates of the univariate and bivariate models was performed. Specificity near 100% was common among the papers. The primary reason for accuracy differences was sensitivity. The meta-analysis, which was only possible for PCR samples of lesion fragments, revealed a sensitivity of 71% [95% confidence interval (CI) = 0.59; 0.81] and a specificity of 93% (95% CI = 0.83; 0.98) in the bivariate model. The search for measures that could increase the sensitivity of PCR should be encouraged. The quality of the collected material and the optimisation of the amplification of genetic material should be prioritised.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The elderly population is particularly at risk for developing vitamin B12-deficiency. Serum cobalamin does not necessarily reflect a normal B12 status. The determination of methylmalonic acid is not available in all laboratories. Issues of sensitivity for holotranscobalamin and the low specificity of total homocysteine limit their utility. The aim of the present study is to establish a diagnostic algorithm by using a combination of these markers in place of a single measurement. METHODS: We compared the diagnostic efficiency of these markers for detection of vitamin B12 deficiency in a population (n = 218) of institutionalized elderly (median age 80 years). Biochemical, haematological and morphological data were used to categorize people with or without vitamin B12 deficiency. RESULTS: In receiver operating curves characteristics for detection on vitamin B12 deficiency using single measurements, serum folate has the greatest area under the curve (0.87) and homocysteine the lowest (0.67). The best specificity was observed for erythrocyte folate and methylmalonic acid (100% for both) but their sensitivity was very low (17% and 53%, respectively). The highest sensitivity was observed for homocysteine (81%) and serum folate (74%). When we combined these markers, starting with serum and erythrocyte folate, followed by holotranscobalamin and ending by methylmalonic acid measurements, the overall sensitivity and specificity of the algorithm were 100% and 90%, respectively. CONCLUSION: The proposed algorithm, which combines erythrocyte folate, serum folate, holotranscobalamin and methylmalonic acid, but eliminate B12 and tHcy measurements, is a useful alternative for vitamin B12 deficiency screening in an elderly institutionalized cohort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prospective observational study of all HIV infected immigrants visited at the Infectious Diseases Department of the Hospital Universitari Vall d’Hebron from June 2010 to May 2011. Screening of most prevalent tropical diseases was performed according to geographical origin. 190 patients were included. Overall, 36.8% (70/190) patients had at least one positive result for any parasitic disease, including Chagas disease, schistosomiasis, strongyloidiasis, leishmaniasis, intestinal parasitosis and malaria. We propose a screening and management strategy of latent parasitic infections in immigrant HIV infected patients.