877 resultados para Reduced Gases
Resumo:
Aims: Burkholderia cepacia complex (Bcc) isolates causing pulmonary infection in cystic fibrosis (CF) patients grow within an acidic environment in the lung. As exposure to acid pH has been shown to increase intracellular inorganic polyphosphate (polyP) formation in some bacteria, we investigated the inter-relationship between acidic pH and polyP accumulation in Bcc isolates.
Resumo:
For the first time, the coupling of fast transient kinetic switching and the use of an isotopically labelled reactant (15NO) has allowed detailed analysis of the evolution of all the products and reactants involved in the regeneration of a NOx storage reduction (NSR) material. Using realistic regeneration times (ca. 1 s) for Pt, Rh and Pt/Rh-containing Ba/Al2O3 catalysts we have revealed an unexpected double peak in the evolution of nitrogen. The first peak occurred immediately on switching from lean to rich conditions, while the second peak started at the point at which the gases switched from rich to lean. The first evolution of nitrogen occurs as a result of the fast reaction between H2 and/or CO and NO on reduced Rh and/or Pt sites. The second N2 peak which occurs upon removal of the rich phase can be explained by reaction of stored ammonia with stored NOx, gas phase NOx or O2. The ammonia can be formed either by hydrolysis of isocyanates or by direct reaction of NO and H2.
The study highlights the importance of the relative rates of regeneration and storage in determining the overall performance of the catalysts. The performance of the monometallic 1.1%Rh/Ba/Al2O3 catalyst at 250 and 350 °C was found to be dependent on the rate of NOx storage, since the rate of regeneration was sufficient to remove the NOx stored in the lean phase. In contrast, for the monometallic 1.6%Pt/Ba/Al2O3 catalyst at 250 °C, the rate of regeneration was the determining factor with the result that the amount of NOx stored on the catalyst deteriorated from cycle to cycle until the amount of NOx stored in the lean phase matched the NOx reduced in the rich phase. On the basis of the ratio of exposed metal surface atoms to total Ba content, the monometallic 1.6%Pt/Ba/Al2O3 catalyst outperformed the Rh-containing catalysts at 250 and 350 °C even when CO was used as a reductant.
Resumo:
Reduced-size polarized (ZmPolX) basis sets are developed for the second-row atoms X = Si, P, S, and Cl. The generation of these basis sets follows from a simple physical model of the polarization effect of the external electric field which leads to highly compact polarization functions to be added to the chosen initial basis set. The performance of the ZmPolX sets has been investigated in calculations of molecular dipole moments and polarizabilities. Only a small deterioration of the quality of the calculated molecular electric properties has been found. Simultaneously the size of the present reduced-size ZmPolX basis sets is about one-third smaller than that of the usual polarized (PolX) sets. This reduction considerably widens the range of applications of the ZmPolX sets in calculations of molecular dipole moments, dipole polarizabilities, and related properties.
Resumo:
The reaction mechanism and the rate-determining step (RDS) of the isomerisation of n-alkanes (C-4-C-6) over partially reduced MoO3 catalysts were studied through the effects of the addition of an alkene isomerisation catalyst (i.e. CoAlPO- 11). When an acidic CoAlPO- 11 sample was mechanically mixed with the MoO3, a decrease of the induction period and an increase of the steady-state conversion of n-butane to isobutane were observed. These data support previous assumptions that a bifunctional mechanism occurred over the partially reduced MoO3 (a complex nanoscale mixture of oxide-based phases) during n-butane isomerisation and that the RDS was the skeletal isomerisation of the linear butene intermediates. The only promotional effect of CoAlPO-11 on the activity of partially reduced MoO3 for C-5-C-6 alkane hydroisomerisation was a reduction of the induction period, as the RDS at steady-state conditions appeared to be dehydrogenation of the alkane in this case. However, lower yields of branched isomers were observed in this case, the reason of which is yet unclear. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
In this paper, a reduced-complexity soft-interference-cancellation minimum mean-square-error.(SIC-MMSE) iterative equalization method for severe time-dispersive multiple-input-multiple-output (MIMO) channels is proposed. To mitigate the severe time dispersiveness of the channel, a single carrier with cyclic prefix is employed, and the equalization is per-formed in the frequency domain. This simplifies the challenging problem of equalization in MIMO channels due to both the intersymbol interference (ISI) and the coantenna interference (CAI). The proposed iterative algorithm works in two stages. The first stage estimates the transmitted frequency-domain symbols using a low-complexity SIC-MMSE equalizer. The second stage converts the estimated frequency-domain symbols in the time domain and finds their means and variances to incorporate in the SIC-MMSE equalizer in the next iteration. Simulation results show the bit-/symbol-error-rate performance of the SIC-MMSE equalizer, with and without coding, for various modulation schemes.
Resumo:
OBJECTIVES:
Renal disease is increasingly regarded as an independent risk factor for vascular disease which in itself is believed to influence risk of AD. Alterations in amyloid homeostasis via reduced renal clearance of peripheral beta-amyloid (A|*beta*|) may represent another potential role for variation in renal function leading to increased risk of AD. We sought to examine estimates of glomerular filtration rate in AD and control groups.
METHODS:
AD patients were randomly recruited from the Memory Clinic of the Belfast City Hospital (n = 83). Genomic DNA was extracted from peripheral leucocytes and was genotyped for Apolipoprotein E using standard methods. Using creatinine values, age and gender, estimated Glomerular Filtration Rates (eGFR) were calculated using the isotope dilution mass spectrometry (IDMS)-traceable Modification of Diet in Renal Disease (MDRD) Study equation (using the United Kingdom National External Quality Assessment Scheme (UKNEQAS) correction factor). IDMS eGFR values were then compared between AD and control groups.
RESULTS:
Significant baseline differences in age, diastolic blood pressure, education level attained and APOE |*epsilon*|4 carriage were noted between cases and controls. The AD group had a significantly lower eGFR versus controls (69 vs 77 ml/min) which persisted after adjustment for possible confounders (p = 0.045).
CONCLUSIONS:
This case-control analysis suggests that using a relatively accurate estimate of renal function, patients with AD have greater renal impairment than cognitively normal controls. This may reflect impaired renal clearance of peripheral A|*beta*| or be a marker of shared vascular processes altering cerebral and renal functioning.