972 resultados para Ray Computed-tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We prospectively evaluated the results of our custom cementless femoral stems to ascertain whether this technology produced reasonable clinical function, complication rates, and loosening rates at midterm. Fifty-seven consecutive patients had surgery in 62 hips for primary osteoarthritis at a mean age of 57 years using a three-dimensional computed custom cementless stem. Patients were reviewed at a mean followup of 94.9 months. At review, the mean Harris hip score was 98.8 points (range, 84-100) compared with 61.1 (range, 28-78) points preoperatively. No patient complained of thigh pain. No migration or subsidence was observed. All stems were considered stable according to the radiographic criteria defined by Engh et al. There were no dislocations, no infections, and no reoperations. Our results are comparable with published results from clinical and radiologic points of view. Two problems remain unsolved: the price of a custom stem is twice as expensive as a standard stem; and we need longer term results before definitely recommending this technology as a reasonable alternative to current arthroplasties in younger patients. The data support the continued exploration of this technology with controlled clinical followup. LEVEL OF EVIDENCE: Therapeutic study, Level II-1 (prospective cohort study). See the Guidelines to Authors for a complete description of levels of evidence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Developing a novel technique for the efficient, noninvasive clinical evaluation of bone microarchitecture remains both crucial and challenging. The trabecular bone score (TBS) is a new gray-level texture measurement that is applicable to dual-energy X-ray absorptiometry (DXA) images. Significant correlations between TBS and standard 3-dimensional (3D) parameters of bone microarchitecture have been obtained using a numerical simulation approach. The main objective of this study was to empirically evaluate such correlations in anteroposterior spine DXA images. Thirty dried human cadaver vertebrae were evaluated. Micro-computed tomography acquisitions of the bone pieces were obtained at an isotropic resolution of 93μm. Standard parameters of bone microarchitecture were evaluated in a defined region within the vertebral body, excluding cortical bone. The bone pieces were measured on a Prodigy DXA system (GE Medical-Lunar, Madison, WI), using a custom-made positioning device and experimental setup. Significant correlations were detected between TBS and 3D parameters of bone microarchitecture, mostly independent of any correlation between TBS and bone mineral density (BMD). The greatest correlation was between TBS and connectivity density, with TBS explaining roughly 67.2% of the variance. Based on multivariate linear regression modeling, we have established a model to allow for the interpretation of the relationship between TBS and 3D bone microarchitecture parameters. This model indicates that TBS adds greater value and power of differentiation between samples with similar BMDs but different bone microarchitectures. It has been shown that it is possible to estimate bone microarchitecture status derived from DXA imaging using TBS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recently, modern cross-sectional imaging techniques such as multi-detector computed tomography (MDCT) have pioneered post mortem investigations, especially in forensic medicine. Such approaches can also be used to investigate bones non-invasively for anthropological purposes. Long bones are often examined in forensic cases because they are frequently discovered and transferred to medico-legal departments for investigation. To estimate their age, the trabecular structure must be examined. This study aimed to compare the performance of MDCT with conventional X-rays to investigate the trabecular structure of long bones. Fifty-two dry bones (24 humeri and 28 femora) from anthropological collections were first examined by conventional X-ray, and then by MDCT. Trabecular structure was evaluated by seven observers (two experienced and five inexperienced in anthropology) who analyzed images obtained by radiological methods. Analyses contained the measurement of one quantitative parameter (caput diameter of humerus and femur) and staging the trabecular structure of each bone. Preciseness of each technique was indicated by describing areas of trabecular destruction and particularities of the bones, such as pathological changes. Concerning quantitative parameters, the measurements demonstrate comparable results for the MDCT and conventional X-ray techniques. In contrast, the overall inter-observer reliability of the staging was low with MDCT and conventional X-ray. Reliability increased significantly when only the results of the staging performed by the two experienced observers were compared, particularly regarding the MDCT analysis. Our results also indicate that MDCT appears to be better suited to a detailed examination of the trabecular structure. In our opinion, MDCT is an adequate tool with which to examine the trabecular structure of long bones. However, adequate methods should be developed or existing methods should be adapted to MDCT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Preoperative imaging for resection of chest wall malignancies is generally performed by computed tomography (CT). We evaluated the role of (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in planning full-thickness chest wall resections for malignancies. We retrospectively included 18 consecutive patients operated from 2004 to 2006 at our institution. Tumor extent was measured by CT and PET, using the two largest perpendicular tumor extensions in the chest wall plane to compute the tumor surface assuming an elliptical shape. Imaging measurements were compared to histopathology assessment of tumor borders. CT assessment consistently overestimated the tumor size as compared to PET (+64% vs. +1%, P<0.001). Moreover, PET was significantly better than CT at defining the size of lesions >24 cm(2) corresponding to a mean diameter >5.5 cm or an ellipse of >4 cm x 7.6 cm (positive predictive value 80% vs. 44% and specificity 93% vs. 64%, respectively). Metabolic PET imaging was superior to CT for defining the extent of chest wall tumors, particularly for tumors with a diameter >5.5 cm. PET can complement CT in planning full-thickness chest wall resection for malignancies, but its true value remains to be determined in larger, prospective studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS: This study was performed to compare the sensitivity of ultrasonography, computerized tomography during arterial portography, delayed computerized tomography, and magnetic resonance imaging to detect focal liver lesions. Forty three patients with primary or secondary malignant liver lesions were studied prior to surgical intervention. METHODS: The results of the imaging studies were compared with intraoperative examination of the liver, intraoperative ultrasonography and pathology results (29 patients). In the non-operated (14 patients) group, we compared the number of lesions detected by each technique. RESULTS: One hundred and forty six lesions were detected. There was 84% sensitivity with computerized tomography during arterial portography, 61.3% with delayed scan, 63.3% with magnetic resonance imaging and 51% with ultrasonography in operated patients. In patients who did not undergo surgery, magnetic resonance imaging was more sensitive in detecting lesions. CONCLUSIONS: In operated and non-operated patients series, CT during arterial portography had the highest sensitivity, but magnetic resonance imaging had the most consistent overall results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Impressive developments in X-ray imaging are associated with X-ray phase contrast computed tomography based on grating interferometry, a technique that provides increased contrast compared with conventional absorption-based imaging. A new "single-step" method capable of separating phase information from other contributions has been recently proposed. This approach not only simplifies data-acquisition procedures, but, compared with the existing phase step approach, significantly reduces the dose delivered to a sample. However, the image reconstruction procedure is more demanding than for traditional methods and new algorithms have to be developed to take advantage of the "single-step" method. In the work discussed in this paper, a fast iterative image reconstruction method named OSEM (ordered subsets expectation maximization) was applied to experimental data to evaluate its performance and range of applicability. The OSEM algorithm with different subsets was also characterized by comparison of reconstruction image quality and convergence speed. Computer simulations and experimental results confirm the reliability of this new algorithm for phase-contrast computed tomography applications. Compared with the traditional filtered back projection algorithm, in particular in the presence of a noisy acquisition, it furnishes better images at a higher spatial resolution and with lower noise. We emphasize that the method is highly compatible with future X-ray phase contrast imaging clinical applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of gamma spectrometry and gamma and X-ray tomography of nuclear fuel is to determine both radionuclide concentration and integrity and deformation of nuclear fuel. The aims of this thesis have been to find out the basics of gamma spectrometry and tomography of nuclear fuel, to find out the operational mechanisms of gamma spectrometry and tomography equipment of nuclear fuel, and to identify problems that relate to these measurement techniques. In gamma spectrometry of nuclear fuel the gamma-ray flux emitted from unstable isotopes is measured using high-resolution gamma-ray spectroscopy. The production of unstable isotopes correlates with various physical fuel parameters. In gamma emission tomography the gamma-ray spectrum of irradiated nuclear fuel is recorded for several projections. In X-ray transmission tomography of nuclear fuel a radiation source emits a beam and the intensity, attenuated by the nuclear fuel, is registered by the detectors placed opposite. When gamma emission or X-ray transmission measurements are combined with tomographic image reconstruction methods, it is possible to create sectional images of the interior of nuclear fuel. MODHERATO is a computer code that simulates the operation of radioscopic or tomographic devices and it is used to predict and optimise the performance of imaging systems. Related to the X-ray tomography, MODHERATO simulations have been performed by the author. Gamma spectrometry and gamma and X-ray tomography are promising non-destructive examination methods for understanding fuel behaviour under normal, transient and accident conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ABSTRACTObjective:the study has the intention of evaluate the accuracy of computed tomography for the diagnosis of cervical lesions on penetrating neck trauma and also identify the most frequent mechanisms of trauma. Most injured structures, determine the age range and the most prevalent sex.Methods: observational descriptive retrospective study executed by the systematic retrospective review of medical records of all patients victims of penetrating neck trauma that went through surgery and CT scans, admitted into Hospital do Trabalhador, between January 2009 and December 2013.Results:the final sample was of 30 patients, 96.7% of the male sex, the median age was of 28 years old. Most patients suffered injuries by gun (56.7%) and 33,3% suffered stab wounds. The most stricken area of the neck was Zone II (77.8%) and the left side (55.2%). Regarding the structures injured, the CT showed 6.7% lesions on airways but the surgery showed 40% of damaged, with a value of p=0.002. As to damages of the esophagus and pharynx the CT detected 10% of lesions, while surgery found 30% of lesions, therefore with a significant value of p=0.013. As for the analysis the CT showed reliable. As for the analysis of vascular damage, the CT showed to be, in most cases, reliable to the findings during the surgical act.Conclusion:besides the great use of CT for the diagnosis of penetrating neck injuries we can say that this is an exam with low accuracy for the diagnosis of lesions of aerodigestive tract, therefore it is important a clinical correlation for a good diagnosis.as for the vascular lesions and of other structures, the CT had high sensibility and specificity, thus a good exam to be used in overall.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: to assess the prevalence of abnormalities found by computed tomography (CT) of the chest in patients with squamous cell carcinoma of the head and neck. Methods: we retrospectively analyzed chest CT exams of 209 patients with squamous cell carcinoma of the head and neck. The CT findings were stratified as inflammatory / infectious, parenchymal, nodular uncharacteristic and nodular metastatic / tumoral Results: alterations were diagnosed in 66.6% of patients. Of these, 25.3% represented emphysema; 18.8%, uncharacteristic micronodules; 12.9%, metastases; 11.9%, thoracic lymph node enlargements; and in 6.6% we detected active pulmonary tuberculosis or its sequelae, pneumonia or inflammatory / infectious signs and pleural thickening or effusion. Conclusion: the prevalence of exams with alterations and the considerable rate of detected metastases indicate that chest CT should be required for diagnostic and / or staging in cases of head and neck cancer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

R. Benjamin (1995) addressed the application of the “object 3D” X ray reconstruction technique for electronically “unpacking” suspect items, when screening aircraft luggage. However, there is no satisfactory solution to the mass screening of hold luggage. Computed Tomography, CT, entails excessive radiation dosages, and its rate of throughput is quite inadequate. A novel variant of “object 3D” is therefore put forward, adapting some of the technology of existing cabin luggage screening systems-but on a substantially larger scale-which does achieve the required throughput at an acceptable radiation dosage and cost.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess positive end-expiratory pressure (PEEP)-induced lung overdistension and alveolar recruitment in six patients with acute lung injury (ALI) using a computed tomographic (CT) scan method. Lung overdistension was first determined in six healthy volunteers in whom CT sections were obtained at FRC and at TLC with a positive airway pressure of 30 cm H2O. In patients, lung volumes were quantified by the analysis of the frequency distribution of CT numbers on the entire lung at zero end-expiratory pressure (ZEEP) and PEEP. In healthy volunteers at FRC, the distribution of the density histograms was monophasic with a peak at -791 ± 12 Hounsfield units (HU). The lowest CT number observed was -912 HU. At TLC, lung volume increased by 79 ± 35% and the peak CT number decreased to -886 ± 26 HU. More than 70% of the increase in lung volume was located below -900 HU, suggesting that this value can be considered as the threshold separating normal aeration from overdistension. In patients with ALI, at ZEEP the distribution of density histograms was either monophasic (n = 3) or biphasic (n = 3). The mean CT number was -319 ± 34 HU. At PEEP 13 ± 3 cm H2O, lung volume increased by 47 ± 19% whereas mean CT number decreased to -538 ± 171 HU. PEEP induced a mean alveolar recruitment of 320 ± 160 ml and a mean lung overdistension of 238 ± 320 ml. In conclusion, overdistended lung parenchyma of healthy volunteers is characterized by a CT number below -900 HU. This threshold can be used in patients with ALI for differentiating PEEP-induced alveolar recruitment from lung overdistension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The SPECT (Single Photon Emission Computed Tomography) systems are part of a medical image acquisition technology which has been outstanding, because the resultant images are functional images complementary to those that give anatomic information, such as X-Ray CT, presenting a high diagnostic value. These equipments acquire, in a non-invasive way, images from the interior of the human body through tomographic mapping of radioactive material administered to the patient. The SPECT systems are based on the Gamma Camera detection system, and one of them being set on a rotational gantry is enough to obtain the necessary data for a tomographic image. The images obtained from the SPECT system consist in a group of flat images that describe the radioactive distribution on the patient. The trans-axial cuts are obtained from the tomographic reconstruction techniques. There are analytic and iterative methods to obtain the tomographic reconstruction. The analytic methods are based on the Fourier Cut Theorem (FCT), while the iterative methods search for numeric solutions to solve the equations from the projections. Within the analytic methods, the filtered backprojection (FBP) method maybe is the simplest of all the tomographic reconstruction techniques. This paper's goal is to present the operation of the SPECT system, the Gamma Camera detection system, some tomographic reconstruction techniques and the requisites for the implementation of this system in a Nuclear Medicine service

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cone beam computed tomography (CBCT) can be considered as a valuable imaging modality for improving diagnosis and treatment planning to achieve true guidance for several craniofacial surgical interventions. A new concept and perspective in medical informatics is the highlight discussion about the new imaging interactive workflow. The aim of this article was to present, in a short literature review, the usefulness of CBCT technology as an important alternative imaging modality, highlighting current practices and near-term future applications in cutting-edge thought-provoking perspectives for craniofacial surgical assessment. This article explains the state of the art of CBCT improvements, medical workstation, and perspectives of the dedicated unique hardware and software, which can be used from the CBCT source. In conclusion, CBCT technology is developing rapidly, and many advances are on the horizon. Further progress in medical workstations, engineering capabilities, and improvement in independent software-some open source-should be attempted with this new imaging method. The perspectives, challenges, and pitfalls in CBCT will be delineated and evaluated along with the technological developments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiological identification is important in forensic medicine. Identification using comparison of individualising structures with ante- and post-mortem conventional radiographs has been known for a long time. New radiological procedures such as computed tomography (CT) and magnetic resonance imaging (MRI) are being increasingly used for identification. In this paper, a new comparative approach using various radiological methods is described and its application demonstrated. This new approach is the comparison of ante-mortem conventional radiographs with projected images calculated from post-mortem CT data. The identification procedure will be illustrated with reference to the frontal sinus and the pelvis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sound speed as a diagnostic marker for various diseases of human tissue has been of interest for a while. Up to now, mostly transmission ultrasound computed tomography (UCT) was able to detect spatially resolved sound speed, and its promise as a diagnostic tool has been demonstrated. However, UCT is limited to acoustically transparent samples such as the breast. We present a novel technique where spatially resolved detection of sound speed can be achieved using conventional pulse-echo equipment in reflection mode. For this purpose, pulse-echo images are acquired under various transmit beam directions and a two-dimensional map of the sound speed is reconstructed from the changing phase of local echoes using a direct reconstruction method. Phantom results demonstrate that a high spatial resolution (1 mm) and contrast (0.5 % of average sound speed) can be achieved suitable for diagnostic purposes. In comparison to previous reflection-mode based methods, CUTE works also in a situation with only diffuse echoes, and its direct reconstruction algorithm enables real-time application. This makes it suitable as an addition to conventional clinical ultrasound where it has the potential to benefit diagnosis in a multimodal approach. In addition, knowledge of the spatial distribution of sound speed allows full aberration correction and thus improved spatial resolution and contrast of conventional B-mode ultrasound. © (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.