991 resultados para Radiology, nuclear medicine


Relevância:

80.00% 80.00%

Publicador:

Resumo:

A comparative study of the parts played by technetium-99m diphosphonate and gallium-67 citrate bone scanning in the early diagnosis of infectious spondylodiscitis is presented. Nineteen patients were included in the study. All patients (11 men aged 19-70 years and eight women aged 18-72 years) had a history of back pain varying in duration from one to 15 weeks. A 99mTc diphosphonate bone scan was positive in 17 patients. The two patients with negative results had less than two weeks of back pain. The 67Ga citrate bone scan showed uptake in all patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: The aim of the study was to determine whether glucose uptake in viable myocardium of ischemic cardiomyopathy patients depends on rest myocardial blood flow (MBF) and the residual myocardial flow reserve (MFR). METHODS: Thirty-six patients with ischemic cardiomyopathy (left ventricular ejection fraction 25&#8201;±&#8201;10 %) were studied with N-ammonia and F-fluorodeoxyglucose (FDG) positron emission tomography (PET). Twenty age-matched normals served as controls. Regional MBF was determined at rest and during dipyridamole hyperemia and regional FDG extraction was estimated from regional FDG to N-ammonia activity ratios. RESULTS: Rest MBF was reduced in viable (0.42&#8201;±&#8201;0.18 ml/min per g) and nonviable regions (0.32&#8201;±&#8201;0.09 ml/min per g) relative to remote regions (0.68&#8201;±&#8201;0.23 ml/min per g, p&#8201;<&#8201;0.001) and to normals (0.63&#8201;±&#8201;0.13 ml/min per g). Dipyridamole raised MBFs in controls, remote, viable, and nonviable regions. MBFs at rest (p&#8201;<&#8201;0.05) and stress (p&#8201;<&#8201;0.05) in viable regions were significantly higher than that in nonviable regions, while MFRs did not differ significantly (p&#8201;>&#8201;0.05). Compared to MFR in remote myocardium, MFRs in viable regions were similar (1.39&#8201;±&#8201;0.56 vs 1.70&#8201;±&#8201;0.45, p&#8201;>&#8201;0.05) but were significantly lower in nonviable regions (1.23&#8201;±&#8201;0.43, p&#8201;<&#8201;0.001). Moreover, the FDG and thus glucose extraction was higher in viable than in remote (1.40&#8201;±&#8201;0.14 vs 0.90&#8201;±&#8201;0.20, p&#8201;<&#8201;0.001) and in nonviable regions (1.13&#8201;±&#8201;0.21, p&#8201;<&#8201;0.001). The extraction of FDG in viable regions was independent of rest MBF but correlated inversely with MFRs (r&#8201;=-0.424, p&#8201;<&#8201;0.05). No correlation between the FDG extraction and MFR was observed in nonviable regions. CONCLUSION: As in the animal model, decreasing MFRs in viable myocardium are associated with increasing glucose extraction that likely reflects a metabolic adaptation of remodeling hibernating myocytes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM: MRI and PET with 18F-fluoro-ethyl-tyrosine (FET) have been increasingly used to evaluate patients with gliomas. Our purpose was to assess the additive value of MR spectroscopy (MRS), diffusion imaging and dynamic FET-PET for glioma grading. PATIENTS, METHODS: 38 patients (42 ± 15 aged, F/M: 0.46) with untreated histologically proven brain gliomas were included. All underwent conventional MRI, MRS, diffusion sequences, and FET-PET within 3±4 weeks. Performances of tumour FET time-activity-curve, early-to-middle SUVmax ratio, choline / creatine ratio and ADC histogram distribution pattern for gliomas grading were assessed, as compared to histology. Combination of these parameters and respective odds were also evaluated. RESULTS: Tumour time-activity-curve reached the best accuracy (67%) when taken alone to distinguish between low and high-grade gliomas, followed by ADC histogram analysis (65%). Combination of time-activity-curve and ADC histogram analysis improved the sensitivity from 67% to 86% and the specificity from 63-67% to 100% (p &lt; 0.008). On multivariate logistic regression analysis, negative slope of the tumour FET time-activity-curve however remains the best predictor of high-grade glioma (odds 7.6, SE 6.8, p = 0.022). CONCLUSION: Combination of dynamic FET-PET and diffusion MRI reached good performance for gliomas grading. The use of FET-PET/MR may be highly relevant in the initial assessment of primary brain tumours.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Radioimmunotherapy Network (RIT-N) is a Web-based, international registry collecting long-term observational data about radioimmunotherapy-treated patients with malignant lymphoma outside randomized clinical studies. The RIT-N collects unbiased data on treatment indications, disease stages, patients' conditions, lymphoma subtypes, and hematologic side effects of radioimmunotherapy treatment. Methods: RIT-N is located at the University of Gottingen, Germany, and collected data from 14 countries. Data were entered by investigators into a Web-based central database managed by an independent clinical research organization. Results: Patients (1,075) were enrolled from December 2006 until November 2009, and 467 patients with an observation time of at least 12 mo were included in the following analysis. Diagnoses were as follows: 58% follicular lymphoma and 42% other B-cell lymphomas. The mean overall survival was 28 mo for follicular lymphoma and 26 mo for other lymphoma subtypes. Hematotoxicity was mild for hemoglobin (World Health Organization grade II), with a median nadir of 10 g/dL, but severe (World Health Organization grade III) for platelets and leukocytes, with a median nadir of 7,000/mu L and 2.2/mu L, respectively. Conclusion: Clinical usage of radioimmunotherapy differs from the labeled indications and can be assessed by this registry, enabling analyses of outcome and toxicity data beyond clinical trials. This analysis proves that radioimmunotherapy in follicular lymphoma and other lymphoma subtypes is a safe and efficient treatment option.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fifty-seven patients with suspected CEA-producing tumors were studied prospectively by radioimmunoscintigraphy (RIS) using a 123I-labeled anti-CEA monoclonal antibody (MAb) (essentially the F(ab')2 or Fab fragments) and emission computed tomography (ECT). Results of RIS were compared to those of a comprehensive diagnostic study. Final diagnosis was based on surgery, biopsy and autopsy (n = 39) or follow-up findings (n = 18). Three groups of patients were defined: Group A with suspected primary tumors (n = 11), Group B with probable (n = 19) and Group C with questionable (n = 27) tumor relapse. Eighty-eight per cent, 93% and 71% of the anatomic regions studied were correctly identified as being involved, and 97%, 97%, and 87% as being free from tumor in Groups A, B, and C, respectively. In the 27 patients from Group C with no definite diagnosis of relapse, and in whom diagnosis was most difficult, 38 tumor sites were involved. Of these, 21 were detected by both prospective RIS and repeated comprehensive study, six by RIS only and seven by conventional methods only. Four sites remained undetected by both approaches. Ten of the 21 lesions were detected by RIS more than 1 mo earlier than by any other method. Among the seven tumor sites detected by other diagnostic modalities only, three were identified at the time of RIS and four became positive more than 6 mo later. Overall diagnosis was entirely correct in 30, partially correct in 16 and incorrect in six patients studied. RIS with ECT and 123I-labeled anti-CEA MAb allows early detection of recurrence or metastasis of colorectal cancer. It thus contributes to reduced delay between diagnosis and treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Paul Ehrlich's inspired concept of 'magic bullets' for the cure of diseases has been revitalized by recent advances in immunology1. In particular, the development of cell fusion technology allowing the production of monoclonal antibodies (Mabs) with exquisite specificities2 triggered new hopes that we may now have the perfect carrier molecules with which to deliver cytotoxic drugs3 or toxins4 to the hidden cancer cells. This article reviews data on one aspect of the magic bullet concept, the use of radiolabelled antibodies as tracers for tumour localization. It will also discuss the very recent clinical use of 131I-labelled Mabs against carcinoembryonic antigen (CEA)5 to detect carcinoma either by conventional external photoscanning or by single photon emission computerized tomography (SPELT). This alliance of the most modern tools from immunology (Mabs) and nuclear medicine (SPELT) appears promising as a way to improve the sensitivity of 'immunoscintigraphy'. However, this approach is not yet ready, for widespread clinical use.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: When planning SIRT using 90Y microspheres, the partition model is used to refine the activity calculated by the body surface area (BSA) method to potentially improve the safety and efficacy of treatment. For this partition model dosimetry, accurate determination of mean tumor-to-normal liver ratio (TNR) is critical since it directly impacts absorbed dose estimates. This work aimed at developing and assessing a reliable methodology for the calculation of 99mTc-MAA SPECT/CT-derived TNR ratios based on phantom studies. Materials and methods: IQ NEMA (6 hot spheres) and Kyoto liver phantoms with different hot/background activity concentration ratios were imaged on a SPECT/CT (GE Infinia Hawkeye 4). For each reconstruction with the IQ phantom, TNR quantification was assessed in terms of relative recovery coefficients (RC) and image noise was evaluated in terms of coefficient of variation (COV) in the filled background. RCs were compared using OSEM with Hann, Butterworth and Gaussian filters, as well as FBP reconstruction algorithms. Regarding OSEM, RCs were assessed by varying different parameters independently, such as the number of iterations (i) and subsets (s) and the cut-off frequency of the filter (fc). The influence of the attenuation and diffusion corrections was also investigated. Furthermore, both 2D-ROIs and 3D-VOIs contouring were compared. For this purpose, dedicated Matlab© routines were developed in-house for automatic 2D-ROI/3D-VOI determination to reduce intra-user and intra-slice variability. Best reconstruction parameters and RCs obtained with the IQ phantom were used to recover corrected TNR in case of the Kyoto phantom for arbitrary hot-lesion size. In addition, we computed TNR volume histograms to better assess uptake heterogeneityResults: The highest RCs were obtained with OSEM (i=2, s=10) coupled with the Butterworth filter (fc=0.8). Indeed, we observed a global 20% RC improvement over other OSEM settings and a 50% increase as compared to the best FBP reconstruction. In any case, both attenuation and diffusion corrections must be applied, thus improving RC while preserving good image noise (COV&lt;10%). Both 2D-ROI and 3D-VOI analysis lead to similar results. Nevertheless, we recommend using 3D-VOI since tumor uptake regions are intrinsically 3D. RC-corrected TNR values lie within 17% around the true value, substantially improving the evaluation of small volume (&lt;15 mL) regions. Conclusions: This study reports the multi-parameter optimization of 99mTc MAA SPECT/CT images reconstruction in planning 90Y dosimetry for SIRT. In phantoms, accurate quantification of TNR was obtained using OSEM coupled with Butterworth and RC correction.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: TIDratio indirectly reflects myocardial ischemia and is correlated with cardiacprognosis. We aimed at comparing the influence of three different softwarepackages for the assessment of TID using Rb-82 cardiac PET/CT. Methods: Intotal, data of 30 patients were used based on normal myocardial perfusion(SSS<3 and SRS<3) and stress myocardial blood flow 2mL/min/g)assessed by Rb-82 cardiac PET/CT. After reconstruction using 2D OSEM (2Iterations, 28 subsets), 3-D filtering (Butterworth, order=10, &#969;c=0.5), data were automatically processed, and then manually processed fordefining identical basal and apical limits on both stress and rest images.TIDratio were determined with Myometrix®, ECToolbox® and QGS®software packages. Comparisons used ANOVA, Student t-tests and Lin concordancetest (&#961;c). Results: All of the 90 processings were successfullyperformed. TID ratio were not statistically different between software packageswhen data were processed automatically (P=0.2) or manually (P=0.17). There was a slight, butsignificant relative overestimation of TID with automatic processing incomparison to manual processing using ECToolbox® (1.07 ± 0.13 vs 1.0± 0.13, P=0.001)and Myometrix® (1.07 ± 0.15 vs 1.01 ± 0.11, P=0.003) but not using QGS®(1.02 ±0.12 vs 1.05 ± 0.11, P=0.16). The best concordance was achieved between ECToolbox®and Myometrix® manual (&#961;c=0.67) processing.Conclusion: Using automatic or manual mode TID estimation was not significantlyinfluenced by software type. Using Myometrix® or ECToolbox®TID was significantly different between automatic and manual processing, butnot using QGS®. Software package should be account for when definingTID normal reference limits, as well as when used in multicenter studies. QGS®software seemed to be the most operator-independent software package, whileECToolbox® and Myometrix® produced the closest results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Berlin ; London

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM: MRI and PET with 18F-fluoro-ethyl-tyrosine (FET) have been increasingly used to evaluate patients with gliomas. Our purpose was to assess the additive value of MR spectroscopy (MRS), diffusion imaging and dynamic FET-PET for glioma grading. PATIENTS, METHODS: 38 patients (42 ± 15 aged, F/M: 0.46) with untreated histologically proven brain gliomas were included. All underwent conventional MRI, MRS, diffusion sequences, and FET-PET within 3±4 weeks. Performances of tumour FET time-activity-curve, early-to-middle SUVmax ratio, choline / creatine ratio and ADC histogram distribution pattern for gliomas grading were assessed, as compared to histology. Combination of these parameters and respective odds were also evaluated. RESULTS: Tumour time-activity-curve reached the best accuracy (67%) when taken alone to distinguish between low and high-grade gliomas, followed by ADC histogram analysis (65%). Combination of time-activity-curve and ADC histogram analysis improved the sensitivity from 67% to 86% and the specificity from 63-67% to 100% (p &lt; 0.008). On multivariate logistic regression analysis, negative slope of the tumour FET time-activity-curve however remains the best predictor of high-grade glioma (odds 7.6, SE 6.8, p = 0.022). CONCLUSION: Combination of dynamic FET-PET and diffusion MRI reached good performance for gliomas grading. The use of FET-PET/MR may be highly relevant in the initial assessment of primary brain tumours.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aims of this study were to determine whether responses in myocardial blood flow (MBF) to the cold pressor testing (CPT) method noninvasively with PET correlate with an established and validated index of flow-dependent coronary vasomotion on quantitative angiography. METHODS: Fifty-six patients (57 +/- 6 y; 16 with hypertension, 10 with hypercholesterolemia, 8 smokers, and 22 without coronary risk factors) with normal coronary angiograms were studied. Biplanar end-diastolic images of a selected proximal segment of the left anterior descending artery (LAD) (n = 27) or left circumflex artery (LCx) (n = 29) were evaluated with quantitative coronary angiography in order to determine the CPT-induced changes of epicardial luminal area (LA, mm(2)). Within 20 d of coronary angiography, MBF in the LAD, LCx, and right coronary artery territory was measured with (13)N-ammonia and PET at baseline and during CPT. RESULTS: CPT induced on both study days comparable percent changes in the rate x pressure product (%DeltaRPP, 37% +/- 13% and 40% +/- 17%; P = not significant [NS]). For the entire study group, the epicardial LA decreased from 5.07 +/- 1.02 to 4.88 +/- 1.04 mm(2) (DeltaLA, -0.20 +/- 0.89 mm(2)) or by -2.19% +/- 17%, while MBF in the corresponding epicardial vessel segment increased from 0.76 +/- 0.16 to 1.03 +/- 0.33 mL x min(-1) x g(-1) (DeltaMBF, 0.27 +/- 0.25 mL x min(-1) x g(-1)) or 36% +/- 31% (P &lt;or= 0.0001). However, in normal controls without coronary risk factors (n = 22), the epicardial LA increased from 5.01 +/- 1.07 to 5.88 +/- 0.89 mm(2) (19.06% +/- 8.9%) and MBF increased from 0.77 +/- 0.16 to 1.34 +/- 0.34 mL x min(-1) x g(-1) (74.08% +/- 23.5%) during CPT, whereas patients with coronary risk factors (n = 34) revealed a decrease of epicardial LA from 5.13 +/- 1.48 to 4.24 +/- 1.12 mm(2) (-15.94% +/- 12.2%) and a diminished MBF increase (from 0.76 +/- 0.20 to 0.83 +/- 0.25 mL x min(-1) x g(-1) or 10.91% +/- 19.8%) as compared with controls (P &lt; 0.0001, respectively), despite comparable changes in the RPP (P = NS). In addition, there was a significant correlation (r = 0.87; P &lt;or= 0.0001) between CPT-related percent changes in LA on quantitative angiography and in MBF as measured with PET. CONCLUSION: The observed close correlation between an angiographically established parameter of flow-dependent and, most likely, endothelium-mediated coronary vasomotion and PET-measured MBF further supports the validity and value of MBF responses to CPT as a noninvasively available index of coronary circulatory function.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This article presents the role of nuclear medicine procedures in investigating renal and parenchymal disease, as well as upper urinary tract abnormalities. More specifically, the use of scintigraphy is described in the exploration of urinary tract dilatation and UTIs, vesicoureteric reflux, renovascular hypertension, and renal transplants. With a low radiation burden and the absence of sedation, these nuclear medicine procedures are easy to perform and can provide clinicians with valuable data on renal perfusion and the function of individual kidneys, as well as on urinary tract dynamics. However, knowledge of limitations and technical pitfalls is essential in understanding the role of scintigraphy among contemporary imaging methods and the unique information it supplies in nephrourology.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A comparative study of the parts played by technetium-99m diphosphonate and gallium-67 citrate bone scanning in the early diagnosis of infectious spondylodiscitis is presented. Nineteen patients were included in the study. All patients (11 men aged 19-70 years and eight women aged 18-72 years) had a history of back pain varying in duration from one to 15 weeks. A 99mTc diphosphonate bone scan was positive in 17 patients. The two patients with negative results had less than two weeks of back pain. The 67Ga citrate bone scan showed uptake in all patients.