999 resultados para Radiation Sensitivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We retrospectively reviewed the long-term outcome and late side effects of endometrial cancer (EC) patients treated with different techniques of postoperative radiotherapy (PORT). METHODS: Between 1999 and 2012, 237 patients with EC were treated with PORT. Two-dimensional external beam radiotherapy (2D-EBRT) was used in 69 patients (30 %), three-dimensional EBRT (3D-EBRT) in 51 (21 %), and intensity-modulated RT (IMRT) with helical Tomotherapy in 47 (20 %). All patients received a vaginal brachytherapy (VB) boost. Seventy patients (29 %) received VB alone. RESULTS: After a median of 68 months (range, 6-154) of follow-up, overall survival was 75 % [95 % confidence interval (CI), 69-81], disease-free survival was 72 % (95% CI, 66-78), cancer-specific survival was 85 % (95 % CI, 80-89), and locoregional control was 86 % (95 % CI, 81-91). The 5-year estimates of grade 3 or more toxicity and second cancer rates were 0 and 7 % (95 % CI, 1-13) for VB alone, 6 % (95 % CI, 1-11) and 0 % for IMRT + VB, 9 % (95 % CI, 1-17) and 5 % (95 % CI, 1-9) for 3D-EBRT + VB, and 22 % (95 % CI, 12-32) and 12 % (95 % CI, 4-20) for 2D-EBRT + VB (P = 0.002 and P = 0.01), respectively. CONCLUSIONS: Pelvic EBRT should be tailored to patients with high-risk EC because the severe late toxicity observed might outweigh the benefits. When EBRT is prescribed for EC, IMRT should be considered, because it was associated with a significant reduction of severe late side effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare multidetector-row computed tomographic (MDCT) enterography with magnetic resonance (MR) enterography performed upon acute exacerbation of Crohn's disease. Subjects and Methods: Fifty-seven patients (mean age 33.5) with proven Crohn's disease and symptoms suggesting acute exacerbation were prospectively included. After oral administration of 1-2 liters of 5% methylcellulose, MDCT and MR enterography were performed on each patient (mean delay <24 h). Three radiologists blindly and independently evaluated each examination for technical quality and in terms of 8 pathological features of Crohn's disease. Observers' agreement, sensitivity and specificity resulted from comparison with the reference standard [surgery (n = 24), endoscopy (n = 17) and long-term follow-up (n = 16)]. Results: MDCT enterography demonstrated fewer artifacts than MR enterography (p < 0.0001). In 48 MDCT/MR enterography examinations, active disease was demonstrated: abscesses (n = 11), fistulas (n = 13), stenoses (n = 23) and/or intestinal inflammation (n = 38). Observers' agreement (range 0.56-0.87) was not significantly different between MDCT and MR enterography, neither in terms of sensitivity (range 58-95%) nor specificity (range 67-100%) for each of the 8 pathological features. Conclusion: Statistically, MR enterography is of similar diagnostic value as MDCT enterography for acute complications of Crohn's disease. Since the typical Crohn's disease patient is young and will very likely undergo life-long imaging, and given concerns about radiation exposure with MDCT, MR enterography should be the preferred modality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inductive-based devices integrated with Si technology for biodetection applications are characterized, using simple resonant differential filter configurations. This has allowed the corroboration of the viability of the proposed circuits, which are characterized by their very high simplicity, for microinductive signal conditioning in high-sensitivity sensor devices. The simulation of these simple circuits predicts sensitivities of the differential output voltage which can achieve values in the range of 0.1-1 V/nH, depending on the coil parameters. These very high-sensitivity values open the possibility for the experimental detection of extremely small inductance changes in the devices. For real microinductive devices, both series resistance and parasitic capacitive components contribute to the decrease of the differential circuit sensitivity. Nevertheless, measurements performed using micro-coils fabricated with relatively high series resistance and coupling parasitic effects have allowed detection of changes in the range of 2 nH. which are compatible with biodetection applications with estimated detection limits below the picomolarity range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: When planning SIRT using 90Y microspheres, the partition model is used to refine the activity calculated by the body surface area (BSA) method to potentially improve the safety and efficacy of treatment. For this partition model dosimetry, accurate determination of mean tumor-to-normal liver ratio (TNR) is critical since it directly impacts absorbed dose estimates. This work aimed at developing and assessing a reliable methodology for the calculation of 99mTc-MAA SPECT/CT-derived TNR ratios based on phantom studies. Materials and methods: IQ NEMA (6 hot spheres) and Kyoto liver phantoms with different hot/background activity concentration ratios were imaged on a SPECT/CT (GE Infinia Hawkeye 4). For each reconstruction with the IQ phantom, TNR quantification was assessed in terms of relative recovery coefficients (RC) and image noise was evaluated in terms of coefficient of variation (COV) in the filled background. RCs were compared using OSEM with Hann, Butterworth and Gaussian filters, as well as FBP reconstruction algorithms. Regarding OSEM, RCs were assessed by varying different parameters independently, such as the number of iterations (i) and subsets (s) and the cut-off frequency of the filter (fc). The influence of the attenuation and diffusion corrections was also investigated. Furthermore, both 2D-ROIs and 3D-VOIs contouring were compared. For this purpose, dedicated Matlab© routines were developed in-house for automatic 2D-ROI/3D-VOI determination to reduce intra-user and intra-slice variability. Best reconstruction parameters and RCs obtained with the IQ phantom were used to recover corrected TNR in case of the Kyoto phantom for arbitrary hot-lesion size. In addition, we computed TNR volume histograms to better assess uptake heterogeneityResults: The highest RCs were obtained with OSEM (i=2, s=10) coupled with the Butterworth filter (fc=0.8). Indeed, we observed a global 20% RC improvement over other OSEM settings and a 50% increase as compared to the best FBP reconstruction. In any case, both attenuation and diffusion corrections must be applied, thus improving RC while preserving good image noise (COV<10%). Both 2D-ROI and 3D-VOI analysis lead to similar results. Nevertheless, we recommend using 3D-VOI since tumor uptake regions are intrinsically 3D. RC-corrected TNR values lie within 17% around the true value, substantially improving the evaluation of small volume (<15 mL) regions. Conclusions: This study reports the multi-parameter optimization of 99mTc MAA SPECT/CT images reconstruction in planning 90Y dosimetry for SIRT. In phantoms, accurate quantification of TNR was obtained using OSEM coupled with Butterworth and RC correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To express the negative effects of soil compaction, some researchers use critical values for soil mechanical strength that severely impair plant growth. The aim of this study was to identify this critical compaction depth, to test the functionality of a new, portable penetrometer developed from a spring dynamometer, and compare it to an electronic penetrometer traditionally used in compaction studies of agricultural soils. Three soils with distinct texture were conventionally tilled using a disk plow, and cultivated with different plant species. The critical soil resistance defined to establish critical compaction depth was equal to 1.5 MPa. The results of the new equipment were similar to the electronic penetrometer, indicating its viability as a tool for assessing the soil physical conditions for plant growth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: This article analyses the influence of treatment duration on survival in patients with invasive carcinoma of the cervix treated by radical radiation therapy. METHOD: Three hundred and sixty patients with FIGO stage IB-IIIB carcinoma of the cervix were treated in Lausanne (Switzerland) with external radiation and brachytherapy as first line therapy. Median therapy duration was 45 days. Patients were classified according to the duration of the therapies, taking 60 days (the 75th percentile) as an arbitrary cut-off. RESULTS: The 5-year survival was 61% (S.E. = 3%) for the therapy duration group of less than 60 days and 53% (S.E. = 7%) for the group of more than 60 days. In terms of univariate hazard ratio (HR), the relative difference between the two groups corresponds to a 50% increase of deaths (HR = 1.53, 95% CI = 1.03-2.28) for the longer therapy duration group (P = 0.044). In a multivariate analysis, the magnitude of estimated relative hazards for the longer therapies are confirmed though significance was reduced (HR = 1.52, 95% CI = 0.94-2.45, P = 0.084). CONCLUSION: These findings suggest that short treatment duration is a factor associated with longer survival in carcinoma of the cervix.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Letrozole (LET) has recently been shown to be superior to tamoxifen for postmenopausal patients (pts). In addition, LET radiosensitizes breast cancer cells in vitro. We conducted a phase II randomized study to evaluate concurrent and sequential radiotherapy (RT)-LET in the adjuvant setting. We present here clinical results with a minimum follow-up of 24 months. Patients and Methods: Postmenopausal pts with early-stage breast cancer were randomized after conservative surgery to either: A) concurrent RT-LET (LET started 3 weeks before the first day of RT) or B) sequential RT-LET (LET started 3 weeks after the end of RT). Whole breast RT was delivered to a total dose of 50 Gy. A 10-16 Gy boost was allowed according to age and pathological prognostic factors. Pts were stratified by center, adjuvant chemotherapy, boost, and radiation-induced CD8 apoptosis (RILA). RILA was performed before RT as previously published (Ozsahin et al. Clin Cancer Res, 2005). An independent monitoring committee reviewed individual safety data. Skin toxicities were evaluated by two different clinicians at each medical visit (CTCAE v3.0). Lung CT-scan and functional pulmonary tests were performed regularly. DNA samples were screened for SNPs in candidate genes as recently published (Azria et al., Clin Cancer Res, 2008). Results: A total of 150 pts were randomized between 01/05 and 02/07. Median follow-up is 26 months (range, 3-40 months). No statistical differences were identified between the two arms in terms of mean age; initial TNM; median surgical bed volume; post surgical breast volume. Chemotherapy and RT boost were delivered in 19% and 38% of pts, respectively. Nodes received 50 Gy in 23% of patients without differences between both arms. During RT and within the first 6 weeks after RT, 10 patients (6.7%) presented grade 3 acute skin dermatitis during RT but no differences were observed between both arms (4 and 6 patients in arm A and B, respectively). At 26 month of follow-up, grade 2 and more radiation-induced subcutaneous fibrosis (RISCF) was present in 4 patients (3%) without any difference between arm A (n = 2) and B (n = 2), p=0.93. In both arms, all patients that presented a RICSF had a RILA lower than 16%. Sensitivity and specificity were 100% and 39%, respectively.No acute lung toxicities were observed and quality of life was good to excellent for all patients.SNPs analyses are still on-going (Pr Rosenstein, NY). Conclusion: Acute and early late grade 2 dermatitis were similar in both arms. The only factor that influenced RISCF was a low radiation-induced lymphocyte apoptosis yield. We confirmed prospectively the capacity of RILA for identifying hypersensitive patients to radiation. Indeed, patients with RILA superior to 16% did not present late effects to radiation and confirmed the first prospective trial we published in 2005 (Ozsahin et al., Clin Cancer Res).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Moisture sensitivity of Hot Mix Asphalt (HMA) mixtures, generally called stripping, is a major form of distress in asphalt concrete pavement. It is characterized by the loss of adhesive bond between the asphalt binder and the aggregate (a failure of the bonding of the binder to the aggregate) or by a softening of the cohesive bonds within the asphalt binder (a failure within the binder itself), both of which are due to the action of loading under traffic in the presence of moisture. The evaluation of HMA moisture sensitivity has been divided into two categories: visual inspection test and mechanical test. However, most of them have been developed in pre-Superpave mix design. This research was undertaken to develop a protocol for evaluating the moisture sensitivity potential of HMA mixtures using the Nottingham Asphalt Tester (NAT). The mechanisms of HMA moisture sensitivity were reviewed and the test protocols using the NAT were developed. Different types of blends as moisture-sensitive groups and non-moisture-sensitive groups were used to evaluate the potential of the proposed test. The test results were analyzed with three parameters based on performance character: the retained flow number depending on critical permanent deformation failure (RFNP), the retained flow number depending on cohesion failure (RFNC), and energy ratio (ER). Analysis based on energy ratio of elastic strain (EREE ) at flow number of cohesion failure (FNC) has higher potential to evaluate the HMA moisture sensitivity than other parameters. If the measurement error in data-acquisition process is removed, analyses based on RFNP and RFNC would also have high potential to evaluate the HMA moisture sensitivity. The vacuum pressure saturation used in AASHTO T 283 and proposed test has a risk to damage specimen before the load applying.