1000 resultados para Perceção Global de Melhoria


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa, para a obtenção Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dependência energética das grandes economias mundiais, alertaram o mundo para a necessidade de mudar o comportamento relativo ao consumo de energia. O sector dos edifícios representa 40% dos consumos globais de energia na União Europeia, já no panorama nacional, o sector dos edifícios representa 28% dos consumos globais da energia, constituindo uma parte significativa no consumo global de energia, sendo portanto, essencial avaliar o desempenho energético dos edifícios, no sentido de promover a sua eficiência energética e beneficiar do grande potencial de economia de energia. Portugal à luz das linhas de orientação da União Europeia com o objectivo de instigar o aumento da eficiência energética nos edifícios, lançou o programa nacional para a eficiência energética nos Edifícios (P3E). Posteriormente, da transposição da Directiva 2002/91/CE para a ordem jurídica nacional surgiu o SCE, o RCCTE e o RSECE. Já em 2013, com a necessidade de transpor para a ordem da jurídica nacional a Directiva n.º 2010/31/EU, surge o Decreto-Lei n.º 118/2013, reunindo num só diploma o SCE, o REH e o RECS, promovendo uma revisão da legislação nacional, garantindo e promovendo a melhoria do desempenho energético dos edifícios. Através da presente dissertação, pretende-se avaliar o desempenho energético de uma pequena fracção de serviços existente tendo por base a metodologia regulamentar revogada do RSECE e a vigente metodologia regulamentar do RECS. Após apresentação dos dois regulamentos e da identificação das principais diferenças entre as duas metodologias regulamentares, procedeu-se ao enquadramento da fracção em estudo no âmbito de aplicação do RSECE e do RECS. Segundo os dois regulamentos a fracção não está sujeita a requisitos mínimos de qualidade térmica, nem a quaisquer requisitos energéticos e de eficiência dos sistemas técnicos, ao tratar-se de uma pequena fracção de serviços existente. Recorrendo ao software DesignBuilder, gerou-se o modelo da fracção em estudo, que através da simulação dinâmica multizona permitiu obter os consumos de energia anuais e a sua desagregação por utilização final. A partir dos consumos energia, determinaram-se os indicadores de eficiência energética de acordo com as duas metodologias, permitindo deste modo, proceder à classificação energética da fracção em estudo. De acordo com o RSECE a fracção em estudo obteve a classificação D, já segundo o RECS alcançou a classe C. Para aumentar a eficiência energética da fracção e consequentemente diminuir o consumo energético, foi proposto proceder à substituição das lâmpadas existentes por lâmpadas tubulares de tecnologia LED e à substituição do sistema de ventilação mecânico por um sistema de ventilação dimensionado para os novos valores de caudal de ar novo regulamentares. Com a implementação destas duas medidas a fracção em estudo melhoraria a sua classificação energética, exigindo um investimento baixo e apresentando um período de retorno de 1 ano e 5 meses. Segundo o RSECE passaria para a classe B, e aplicando a metodologia regulamentar do RECS alcançaria a classe B-.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia e Gestão Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A presente dissertação tem dois objetivos, o primeiro é a realização de uma auditoria energética e avaliação da qualidade do ar às instalações de uma Piscina Municipal, permitindo a sua classificação energética, e o segundo é o estudo de propostas de melhoria que contribuam para uma melhor eficiência energética do edifício. Na análise à qualidade do ar interior os parâmetros avaliados encontravam-se todos dentro dos limites estabelecidos por lei, com exceção dos valores de COVs que em dois pontos de medição (ambos na nave) ultrapassaram os limites estabelecidos por lei. A auditoria ao edifício permitiu verificar que o caudal mínimo de água nova nas piscinas imposto por lei é cumprido pela instalação. No que diz respeito ao caudal de ar novo introduzido, este apenas é respeitado quando a unidade de tratamento de ar está a debitar 100% da sua capacidade. Quando a unidade opera a 50% da sua capacidade apresenta um défice de 5% do valor mínimo estabelecido. Relativamente às perdas energéticas associadas aos tanques de natação, estas apresentam um valor de 95,89 kW, em que 59,09 kW dizem respeito às perdas por evaporação. Foi também possível concluir que as perdas por evaporação representam cerca de 39% da energia calorifica produzida nas caldeiras. O edifício apresenta um consumo anual de eletricidade de 166 482 kWh em que 69% deste valor é provocado pelas unidades de tratamento de ar e a iluminação apresenta apenas um peso de 3%. Em relação ao gás natural consumido pelas caldeiras o seu valor anual é de 1 317 240 kWh. A simulação dinâmica do edifício permitiu concluir que este apresenta um IEE de 1 269,9 kWh/m2.ano. O rácio de classe energética (RIEE) é de 1,24 o que significa que o edifício pertence à classe energética C. As medidas estudadas para a melhoria da eficiência energética, nomeadamente integração energética com uma central de ciclo combinado, aplicação de cobertura isotérmica nas piscinas e substituição do telhado na zona da nave, mostraram-se viáveis. O estudo da possibilidade da realização de uma integração energética permitiu concluir que a poupança anual é de 9 374 € e o investimento é recuperado em menos de 1,5 anos. Relativamente à aplicação de cobertura isotérmica o investimento é de 14 000 € e é recuperado em 2 anos. A substituição do telhado na zona da nave tem um investimento de 20 500 € e a recuperação realiza-se num período de 3,5 anos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente, perfil Gestão de Sistemas Ambientais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A tese de mestrado teve como objetivo o estudo e análise do funcionamento das centrais de cogeração e térmica da fábrica da Unicer em Leça do Balio, com o intuito de melhorar a sua eficiência, propondo alterações processuais. O trabalho realizado consistiu no reconhecimento das instalações, seguido da formulação e resolução dos balanços de energia globais. Com o acompanhamento diário do funcionamento foi possível propor melhorias sem custos que se revelaram muito benéficas, registando-se um aumento nas recuperações térmicas e por consequência no Rendimento Elétrico Equivalente (R.E.E.), na eficiência da instalação da cogeração e da central térmica. Na cogeração registou-se um aumento de 36,2% na potência recuperada em água quente, aproximadamente 600 kW, sendo já superior à prevista pelo projeto. Na caldeira recuperativa registou-se um ligeiro aumento de 4,0% na potência recuperada. Deste modo o rendimento térmico da central aumentou 6,4%, atingindo os 40,8% e superando os 40,4% projetados. O rendimento global final foi de 83,1% o que representa um aumento de 6,3%. O R.E.E. em Maio de 2014 foi de 76,3%, superior ao valor em Junho de 2013 em 8,7%. Tendo como referência o valor alvo de 70,5% para o R.E.E. apontado no início do estágio, nos últimos 8 meses o seu valor tem sido sempre superior e em crescimento. Existe ainda a possibilidade de aproveitar a energia térmica de baixa temperatura que está a ser dissipada numa torre de arrefecimento, no mínimo 40 kW, num investimento com um período de retorno de investimento máximo de 8,1 meses. Na central térmica registou-se um aumento do rendimento para a mesma quantidade de energia produzida na central, pois esta é a principal variável do processo. Em 2014 a produção de energia apresentou um valor inferior a 2013, 6,9%, e a eficiência registou um acréscimo de 2,0%. A incorporação de biogás na alimentação de combustível à caldeira bifuel não pareceu comprometer significativamente a eficiência da central térmica, pelo que a sua utilização é benéfica. Com o aumento das recuperações térmicas na central de cogeração foram estimadas poupanças de gás natural equivalentes a 3,3 GWh, o que significa 120.680€ economizados nos últimos 11 meses do trabalho. É esperado uma poupança de 18.000€ mensais com a melhoria do funcionamento obtida nas duas centrais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia do Ambiente, perfil de Gestão e Sistemas Ambientais

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hoje em dia, com os avanços constantes na indústria, novas áreas começam cada vez mais a ser foco de atenção por parte das organizações. Motivados pela procura de melhores condições para os seus colaboradores e por todos os benefícios que este tipo de intervenção oferece, tanto a curto, como principalmente a médio e longo prazo, a Grohe Portugal, mais especificamente o seu departamento de montagem, achou relevante potenciar a aplicação da Ergonomia nos seus postos de trabalho. Posto isto, esta dissertação pretende apresentar o trabalho desenvolvido junto da organização que teve como objetivo projetar e executar uma linha de montagem que tivesse em consideração os seguintes aspetos: • Ergonomia; • Automatização ou semi-automatização de operações; • Simplificação de aspetos operacionais; • Sistemas de abastecimento mais robustos e de fácil uso; • Simplificação de setups; • Definição de dimensões normalizadas para futuros projetos. As soluções encontradas tiveram como objetivo primordial satisfazer o maior número possível de colaboradores, sendo que para tal foram utilizados dados referentes a antropometria da população Portuguesa. Para a realização e conclusão deste projeto, o trabalho foi decomposto em varias etapas, de entre as quais se destacam: • Analise e estudo dos métodos de montagem; • Levantamento de todos os componentes e operações que constituem o processo de fabrico das diversas famílias onde foram implementados novos projetos; • Definição e uniformização da estrutura das novas linhas de montagem; • Estudo e definição da disposição dos componentes na nova linha, bem como da sua forma de abastecimento; • Projeto da linha de montagem em 3D com recurso ao software SolidWorks (DassaultSystemes, 2014); • Montagem final da linha, bem como o acompanhamento da sua fase de arranque. Durante o estagio foi ainda pensado e implementado um projeto paralelo com vista a constante manutenção e melhoria do departamento de montagem cujo objetivo, através de “plant walks”, e detetar de entre outras, situações de falta de identificação de componentes ou equipamentos, degradação de ferramentas, fugas ou derrames nas linhas, etc. O balanco final do trabalho foi bastante positivo, tendo-se alcançado melhorias em alguns índices de qualidade, tempos de abastecimento e condições ergonómicas dos postos de trabalho que sofreram intervenção, tendo essas melhorias resultado numa avaliação positiva por parte dos colaboradores que integram essas mesmas linhas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO: Objectivo: O exercício tem sido identificado como um factor de promoção da qualidade de vida em mulheres submetidas a cirurgia por cancro de mama. Mas os níveis de actividade física tendem a reduzir após o diagnóstico de cancro de mama e a manterem-se baixos após fim dos tratamentos. O objectivo deste estudo é verificar se um programa de exercício físico supervisionado, associado a estratégias motivacionais em mulheres submetidas a cirurgia por cancro da mama e que mantêm a intervenção usual praticada, é mais efectivo no aumento dos níveis de actividade física, na redução do índice de massa corporal e na melhoria da qualidade de vida, do que o tratamento usualmente praticado. Metodologia: Trata-se de um estudo piloto experimental, aleatorizado e controlado. Cumpriram os critérios de inclusão no estudo 37 utentes submetidas a cirurgia por cancro de mama no Hospital Fernando Fonseca, Amadora, e submetidos à intervenção usual da fisioterapia. Foram aleatoriamente distribuídas pelos grupos experimental (n=19) e de controlo (n=18). O contacto telefónico foi feito por um elemento externo, cego em relação à distribuição dos sujeitos. Alguns elementos desistiram ou não puderam participar no estudo. O número de sujeitos final foi de 11 para o grupo experimental e de 10 para o grupo de controlo, idênticos na média de idades. Todos os sujeitos mantiveram a intervenção usual da fisioterapia. Os sujeitos do grupo experimental foram ainda submetidos ao programa de exercício e promoção da actividade física. Todo o grupo foi avaliado no início do programa, no final do mesmo (12 semanas) e após 6 meses de follow-up, nos seguintes indicadores: nível de actividade física, pelo International Physical Activity Questionnaire (IPAQ), índice de massa corporal e qualidade de vida, pelos questionários: European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30) e Supplementary Questionnaire Breast Cancer Module (QLQ-BR23). Resultados: O programa implementado demonstrou-se efectivo no aumento dos níveis de actividade física (p=0,017) e na qualidade de vida associada ao estado funcional (p=0,016) e ao estado de saúde global auto-percepcionado (p=0,030) no final do programa. Foi ainda possível identificar resultados positivos noutras variáveis estudadas, como por exemplo a fadiga auto-reportada, mas que não se demonstraram estatisticamente significativos, facto que pode atribuir-se à reduzida dimensão da amostra. Conclusões: Apesar de algumas limitações, este estudo é de grande a importância para a comunidade científica preocupada com crescente problemática do cancro de mama. Mais uma vez se demonstra que o exercício físico é uma estratégia importante para a melhoria do estado de saúde de pacientes confrontados com doença. Esta comprovação é de grande interesse para os profissionais de saúde e particularmente para os fisioterapeutas dedicados à promoção da saúde nesta população.---------------------ABSTRACT: Purpose: Exercise has been identified as a quality of life promoting factor, amongst women after breast cancer surgery. But the physical activity levels reduce significantly after a diagnosis of breast cancer and remain low after treatment is completed. The aim of this study is to determine whether a supervised group exercise program allied to motivating strategies in women after breast cancer surgery in conjunction with standard treatment, is more effective in improving physical activity levels, reducing body mass index and promoting quality of life, than standard treatment on its own. Methods: This is a pilot randomized controlled trial. Thirty-seven women, submitted to breast cancer surgery in the Hospital Fernando Fonseca, Amadora, and submitted to standard physiotherapy intervention, completed the inclusion criteria. They were randomly allocated into intervention group (n=19) and control group (n=18). The telephone contact was done by an external element, blind to the subjects’ allocation. Some elements declined or could not participate. The final intervention group was n=11 and the control n=10, similar in age. All subjects maintained the standard physiotherapy intervention. The experimental group was submitted to the exercise and health promotion program. The complete group was evaluated in the beginning of the program, at the final (after 12 weeks) and after 6 months follow-up, using as outcomes: physical activity index with the international Physical Activity Questionnaire (IPAQ), the body mass index and quality of life using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30) and Supplementary Questionnaire Breast Cancer Module (QLQBR23). Results: The studied program demonstrated to be effective in improving the physical activity index (p=0,017) and quality of live related to physical functioning (p=0,016) and to global health status (p=0,030) at the end of the program. It was possible to find positive results in some other outcomes, such as fatigue, although the differences were not statistically significant. We believe that these results can be attributed to the small sample size. Conclusions: Although we can identify some methodological constrains, this is a very important study for scientific community working on the breast cancer subject. Once more, exercise was identified as an important strategy to improve global heath status in breast cancer patients. This represents an important contribution to the health professionals and mostly for physiotherapists working on health promotion subject.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologias da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenheira e Gestão Industrial

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este artigo apresenta um estudo de consumo de energia elétrica no Brasil, levando-se em consideração o gasto público com este item. Atualmente é verificado um crescente aumento de demanda no setor elétrico brasileiro, o que acarreta em um investimento no setor de modo a atender os consumidores. Visto que a realidade do setor público, não diferindo dos outros consumidores, possui a energia eléctrica como a fonte energética mais utilizada atualmente, correspondendo a 87,4% comparado a outros tipos de fontes energéticas, por exemplo combustíveis fósseis (BEN, 2012). Cada vez mais procura-se meios para que se obtenha um sistema mais eficiente o que implica diretamente na redução dos custos relativos ao investimento no setor elétrico, redução na manutenção das instalações elétricas e consumo de energia elétrica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rede viária de um país proporciona, não só o encurtamento de distâncias como também o desenvolvimento social e económico. Assim, importa que em qualquer ponto do traçado o utilizador possa reconhecer, de forma inequívoca, o seu posicionamento em relação à via e ao seu destino. Neste propósito a sinalização assume um papel fundamental. Sinalização define-se como o interface entre a estrada e o condutor, tendo por base um sistema de comunicação, constituído por mensagens escritas ou simbólicas, que fornecem ao condutor uma correta perceção da estrada em que circula. Este facto, contribui para uma melhoria das condições de segurança rodoviária diminuindo a sua sinistralidade. A nível nacional a sinalização de orientação é regulada pela norma de sinalização vertical de orientação. Todavia identificou-se a necessidade de atualização desta, estando para isso eminente a publicação da versão definitiva da disposição normativa. De referir que ambas não possuem carácter obrigatório, mas constituem um manual de boas práticas na área. Com esta dissertação pretende-se conhecer, a viabilidade e as implicações inerentes à aplicação da disposição normativa, com especial enfoque na metodologia utilizada para a escolha dos destinos inscritos nos painéis de sinalização. Para isso procedeu-se a uma análise comparativa entre a norma de sinalização vertical de orientação e a disposição normativa, através do estudo de casos práticos. Nesse sentido, comparou-se os resultados teóricos obtidos pela aplicação das duas normas e o que, na realidade, se encontra no local. Associadamente procedeu-se a um estudo das normas aplicadas em países europeus de referencia com o intuito de verificar quais as práticas seguidas. Conclui-se, com esta dissertação, que a disposição normativa, pretensa atualização da norma em vigor, carece de diversas melhorias, de forma a proporcionar uma melhor adequação ao panorama rodoviário nacional e proporcionar a continuidade de sinalização orientação transfronteiriça.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A manutenção, durante vários anos, traduziu-se num conceito paliativo de instalações e equipamentos, o que se veio a revelar como uma atitude negligente perante o Homem e o Ambiente. As preocupações ambientais estão na ordem do dia e têm sido muitas as vozes que se têm levantado para que o consumo de energia seja mais equilibrado e para que as emissões de CO2 diminuam de forma a preservar o Planeta. De acordo com a resolução do Conselho Europeu, em 2007 (1), foi apresentado um pacote de propostas que visam a sustentabilidade e estimulam a Eficiência Energética (EE), com o objectivo de reduzir os consumos energéticos dos edifícios, quer estes sejam novos ou reabilitados. Segundo a Direcção Geral de Energia e Geologia os edifícios são responsáveis por 60% dos consumos de energia eléctrica, consumo esse que pode ser reduzido em mais de 50%, através de medidas de EE, traduzindo-se numa redução de 400 milhões de toneladas de CO2 por ano. (2) Para além de medidas de EE, também as práticas de manutenção preventiva podem contribuir para a diminuição dos consumos energéticos e de emissões de CO2. Segundo o Institute for Building Efficiency práticas de manutenção preventiva em equipamentos de Aquecimento Ventilação e Ar Condicionado (AVAC) reduzem os consumos energéticos de 10 a 20% e, em contrapartida, a negligência na execução da manutenção pode aumentar os consumos energéticos de 30 a 60%. (3) Uma outra análise de valores a ter em conta, é a Intensidade Energética (IE). Leia-se IE como sendo o valor global da energia consumida num país a dividir pelo seu produto interno bruto. A contribuição do sector dos serviços para a IE nacional era de 17% no ano de 2005. (4) Se a estes dados acrescentarmos que 70% dessa energia é consumida por equipamentos AVAC (5) e que práticas de manutenção reduzem esses valores entre 10 a 20%, pode concluir-se que a redução de custos energéticos associada à manutenção preventiva é efectiva e significativa. Apresentando um cenário ideal e hipotético, se ao contributo do sector dos serviços, para a IE nacional, se isolar o valor referente a equipamentos de AVAC, obtem-se uma IE de aproximadamente 12%. Se adicionalmente se considerar uma taxa de redução, relativa à execução da manutenção, entre 10 e 20%, Portugal obteria uma IE, relativamente aos consumos energéticos em edificios de serviços, não de 17% mas sim entre 14,6% e 15,8%. Neste trabalho pretende-se comprovar que um plano de actividades de manutenção equilibrado, monitorizado, e gerido de forma eficaz e funcional, é uma ferramenta fundamental no cumprimento de objectivos e metas europeias traçadas, que se reúnem num objectivo comum de preservação do planeta. A adopção deste tipo de medidas contribuirá para a racionalização dos consumos energéticos e para o aumento da vida útil dos equipamentos, bem como para a melhoria do desempenho económico e financeiro das organizações, tal como se poderá ler mais à frente neste trabalho. Será também analisado um caso prático, verificando a eficácia das medidas tomadas durante as intervenções preventivas de manutenção, sendo que para isso será estudado o comportamento de um equipamento, antes e após a realização de tarefas de manutenção preventiva. Tentar-se-á, junto de gestores de edifícios, recolher a opinião que têm sobre a importância da manutenção. Ao longo de toda a pesquisa foi possível consolidar a hipótese formulada inicialmente no que concerne ao contributo da manutenção para a sustentabilidade, quer através da revisão da literatura, quer nos testes efectuados a equipamentos. Foi possível confirmar que um plano de manutenção ajustado, monitorizado e cumprido é uma ferramenta na diminuição dos consumos energéticos, aumento da vida útil de equipamentos e por sua vez na diminuição de emissões de CO2. Verificou-se também que o controlo de poluentes e ventilação adequada dos edifícios são uma ferramenta essencial para a qualidade do ar interior, parâmetros facilmente controlados nas actividades de manutenção. O contributo das opiniões recolhidas entre os gestores de edifícios, para este estudo, foi também bastante importante, uma vez que todos eles reconhecem o papel importante da manutenção, mas nem todos estão sensibilizados para o seu papel na sustentabilidade do planeta. Nesta dissertação é deixado um alerta: o crescimento da população mundial e a consequente utilização de recursos naturais que são finitos, não sendo controlado de uma forma sustentada, pode resultar na destruição de um planeta único. O papel negativo do Homem nas alterações climáticas é inequívoco e é necessário melhorar a sua relação com o Ambiente. Cada ser humano está inserido na sua comunidade e dentro dela tem a sua função, cabe a cada um exercer esta responsabilidade nas suas actividades do dia-a-dia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O marketing transacional apresenta-se nos dias de hoje insuficiente para fazer face às exigências de um consumidor mais participativo, seletivo e crítico. No mercado global, industrializado e em constante evolução tecnológica, é, cada vez mais, difícil obter um grau de diferenciação assente apenas nos benefícios funcionais e racionais. O marketing transacional evoluiu para o marketing relacional, constituindo o cliente o centro do processo de trocas. A economia das experiências alterou a forma como as marcas trabalham o mercado, introduzindo o conceito de experiências, o que por sua vez conceptualizou o marketing experiencial, orientado para a gestão da experiência do cliente, transformando o ato de consumo em algo memorável, cheio de estímulos sensoriais e emocionais, convertendo-se, por vezes, no próprio produto, seja ele de âmbito industrial, desportivo ou mesmo cultural. Este grau de envolvimento do cliente com a marca é elemento gerador de emoção, de satisfação, de lealdade e de valor. Este trabalho pretendeu analisar a importância e os componentes estimuladores do marketing experiencial e a sua relação com as emoções, satisfação e a lealdade dos consumidores no evento cultural “Serralves em festa 2013”. Para tal, utilizamos uma metodologia de investigação quantitativa, com recurso a análise de equações estruturais, suportada por uma pesquisa teórica. O estudo empírico realizado, baseado num inquérito por questionário, possibilitou obter uma amostra de 264 respostas válidas. Após a validação e melhoria das escalas de medida dos conceitos, os resultados destas e do modelo estrutural demonstraram valores adequados. Estudaram-se e comprovaram-se as relações previstas nas hipóteses, nomeadamente, a relação positiva do impacto das experiências no comportamento do consumidor, designadamente, na sua emoção e satisfação e o impacto destas na sua lealdade. Entre as variáveis estudadas foram obtidos interessantes níveis de correlação e capacidades preditivas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Num mercado globalizado, a procura contínua de vantagens competitivas é um fator crucial para o sucesso das organizações. A melhoria contínua dos processos é uma abordagem usual, uma vez que os resultados destas melhorias vão se traduzir diretamente na qualidade dos produtos. Neste contexto, a metodologia Failure Mode Effect Analysis (FMEA) é muito utilizada, especialmente pelas suas características proactivas, que permitem a identificação e a prevenção de erros do processo. Assim, quanto mais eficaz for a aplicação desta ferramenta, mais benefícios terá a organização. Assim, quando é utilizado com eficácia, o FMEA de Processo, além de ser um método poderoso na análise do processo, permite a melhoria contínua e a redução dos custos [1] . Este trabalho de dissertação teve como objetivo avaliar a eficácia da utilização da ferramenta do FMEA de processo numa organização certificada segundo a norma ISO/TS16949. A metodologia proposta passa pela análise de dados reais, ou seja, comparar as falhas verificadas no mercado com as falhas que tinham sido identificadas no FMEA. Assim, ao analisar o nível de falhas identificadas e não identificadas durante o FMEA e a projeção dessas falhas no mercado, consegue-se determinar se o FMEA foi mais ou menos eficaz, e ainda, identificar fatores que condicionam a melhor utilização da mesma. Este estudo, está organizado em três fases, a primeira apresenta a metodologia proposta , com a definição de um fluxograma do processo de avaliação e as métricas usadas, a segunda fase a aplicação do modelo proposto a dois casos de estudo, e uma última fase, que consiste na análise comparativa, individual e global, que visa, além de comparar esultados, identificar pontos fracos durante a execução do FMEA. Os resultados do caso de estudo indicam que a ferramenta do FMEA tem sido usada com eficácia, pois consegue-se identificar uma quantidade significativa de falhas potenciais e evitá-las. No entanto, existem ainda falhas que não foram identificadas no FMEA e que apareceram no cliente, e ainda, algumas falhas que foram identificadas e apareceram no cliente. As falhas traduzem-se em má qualidade e custos para o negócio, pelo que são propostas ações de melhoria. Pode-se concluir que uma boa utilização do FMEA pode ser um fator importante para a qualidade do serviço ao cliente, e ainda, com impacto dos custos.