907 resultados para PRECISION EXPERIMENTS
Resumo:
In e-Science experiments, it is vital to record the experimental process for later use such as in interpreting results, verifying that the correct process took place or tracing where data came from. The process that led to some data is called the provenance of that data, and a provenance architecture is the software architecture for a system that will provide the necessary functionality to record, store and use process documentation. However, there has been little principled analysis of what is actually required of a provenance architecture, so it is impossible to determine the functionality they would ideally support. In this paper, we present use cases for a provenance architecture from current experiments in biology, chemistry, physics and computer science, and analyse the use cases to determine the technical requirements of a generic, technology and application-independent architecture. We propose an architecture that meets these requirements and evaluate a preliminary implementation by attempting to realise two of the use cases.
Resumo:
E-Science experiments typically involve many distributed services maintained by different organisations. After an experiment has been executed, it is useful for a scientist to verify that the execution was performed correctly or is compatible with some existing experimental criteria or standards, not necessarily anticipated prior to execution. Scientists may also want to review and verify experiments performed by their colleagues. There are no existing frameworks for validating such experiments in today's e-Science systems. Users therefore have to rely on error checking performed by the services, or adopt other ad hoc methods. This paper introduces a platform-independent framework for validating workflow executions. The validation relies on reasoning over the documented provenance of experiment results and semantic descriptions of services advertised in a registry. This validation process ensures experiments are performed correctly, and thus results generated are meaningful. The framework is tested in a bioinformatics application that performs protein compressibility analysis.
Resumo:
Current scientific applications are often structured as workflows and rely on workflow systems to compile abstract experiment designs into enactable workflows that utilise the best available resources. The automation of this step and of the workflow enactment, hides the details of how results have been produced. Knowing how compilation and enactment occurred allows results to be reconnected with the experiment design. We investigate how provenance helps scientists to connect their results with the actual execution that took place, their original experiment and its inputs and parameters.
Resumo:
A free-running, temperature stabilized diode laser has been injection-locked to an external cavity diode laser for use in cold Rydberg atom experiments. Cold rubidium atoms in a magneto-optical trap (MOT) are excited to Rydberg states using a 10 ns laser pulse. The Rydberg atoms spontaneously ionize due to dipole forces, and the collisional ionization dynamics are observed as a function of atom density and principal quantum number of the Rydberg state, n. The injection-locked diode laser will be used as a repumper in conjunction with a dark spontaneous-force optical trap (SPOT) to increase the Rydberg state density. We report on the design of the injection-locked laser system.
Resumo:
A visualização de conjuntos de dados volumétricos é comum em diversas áreas de aplicação e há já alguns anos os diversos aspectos envolvidos nessas técnicas vêm sendo pesquisados. No entanto, apesar dos avanços das técnicas de visualização de volumes, a interação com grandes volumes de dados ainda apresenta desafios devido a questões de percepção (ou isolamento) de estruturas internas e desempenho computacional. O suporte do hardware gráfico para visualização baseada em texturas permite o desenvolvimento de técnicas eficientes de rendering que podem ser combinadas com ferramentas de recorte interativas para possibilitar a inspeção de conjuntos de dados tridimensionais. Muitos estudos abordam a otimização do desempenho de ferramentas de recorte, mas muito poucos tratam das metáforas de interação utilizadas por essas ferramentas. O objetivo deste trabalho é desenvolver ferramentas interativas, intuitivas e fáceis de usar para o recorte de imagens volumétricas. Inicialmente, é apresentado um estudo sobre as principais técnicas de visualização direta de volumes e como é feita a exploração desses volumes utilizando-se recorte volumétrico. Nesse estudo é identificada a solução que melhor se enquadra no presente trabalho para garantir a interatividade necessária. Após, são apresentadas diversas técnicas de interação existentes, suas metáforas e taxonomias, para determinar as possíveis técnicas de interação mais fáceis de serem utilizadas por ferramentas de recorte. A partir desse embasamento, este trabalho apresenta o desenvolvimento de três ferramentas de recorte genéricas implementadas usando-se duas metáforas de interação distintas que são freqüentemente utilizadas por usuários de aplicativos 3D: apontador virtual e mão virtual. A taxa de interação dessas ferramentas é obtida através de programas de fragmentos especiais executados diretamente no hardware gráfico. Estes programas especificam regiões dentro do volume a serem descartadas durante o rendering, com base em predicados geométricos. Primeiramente, o desempenho, precisão e preferência (por parte dos usuários) das ferramentas de recorte volumétrico são avaliados para comparar as metáforas de interação empregadas. Após, é avaliada a interação utilizando-se diferentes dispositivos de entrada para a manipulação do volume e ferramentas. A utilização das duas mãos ao mesmo tempo para essa manipulação também é testada. Os resultados destes experimentos de avaliação são apresentados e discutidos.
Resumo:
Recent models of economic voting assume that citizens can discount exogenous factors when assessing government's economic performance. Yet there is evidence that Latin American voters do not behave in such way, and attribute to presidents outcomes that are beyond their control. This paper presents three survey experiments designed to explore mechanisms that could potentially correct such misattribution, and therefore contribute to debiasing individual behavior towards government evaluation. Our results provide individual-level evidence of the misattribution found in aggregate studies of electorate behavior, and reinforce psychologist's skepticism towards prospects of mental decontamination, as we found very scant evidence that providing information, raising awareness, or increasing motivation to correct biases infuenced individual's evaluation of president's performance.
Resumo:
This thesis aims to explore the concept of impression management from the financial analysts’ point of view. Impression management is the definition of the act of an agent manipulating an impression that another person have of this agent, in the context of this thesis it happens when a company make graphics to disclosure financial-accounting information in order to manipulate the market’s perception of their performance. Three types of impression management were analyzed: presentation enhancement (color manipulation), measurement distortion (scale manipulation) and selectivity (the disclosure of positive information only). While presentation enhancement improved only the most impulsive financial analysts’ perception of firm’s performance, the measurement distortion improved the perception of performance for both groups of financial analysts (impulsive and reflective). Finally, selectivity improved the financial analysts’ perception of firm’s performance for both groups (impulsive and reflective), although impulsive financial analysts assigned lower ratings when compared to their reflective peers, on average, to a hypothetical company.
Resumo:
An ultra-fast and improved analytical methodology based on microextraction by packed sorbent (MEPS) combined with ultra-performance LC (UPLC) was developed and validated for determination of (E)-resveratrol in wines. Important factors affecting the performance of MEPS such as the type of sorbent material (C2, C8, C18, SIL, and M1), number of extraction cycles, and sample volume were studied. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (50–250mL) in one extraction cycle (extract–discard) and in a short time period (about 3 min for the entire sample preparation step). (E)-Resveratrol was eluted by 1 250mL of the mixture containing 95% methanol and 5% water, and the separation was carried out on a highstrength silica HSS T3 analytical column (100 mm 2.1 mm, 1.8mm particle size) using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and methanol (eluent B) in the gradient elution mode (10 min of total analysis). The method was fully validated in terms of linearity, detection (LOD) and quantification (LOQ) limits, extraction yield, accuracy, and inter/intra-day precision, using a Madeira wine sample (ET) spiked with (E)-resveratrol at concentration levels ranging from 5 to 60mg/mL. Validation experiments revealed very good recovery rate of 9575.8% RSD, good linearity with r2 values 40.999 within the established concentration range, excellent repeatability (0.52%), and reproducibility (1.67%) values (expressed as RSD), thus demonstrating the robustness and accuracy of the MEPSC8/UPLC-photodiode array (PDA) method. The LOD of the method was 0.21mg/mL, whereas the LOQ was 0.68mg/mL. The validated methodology was applied to 30 commercial wines (24 red wines and six white wines) from different grape varieties, vintages, and regions. On the basis of the analytical validation, the MEPSC8/UPLC-PDA methodology shows to be an improved, sensitive, and ultra-fast approach for determination of (E)-resveratrol in wines with high resolving power within 6 min.
Resumo:
A new approach based on microextraction by packed sorbent (MEPS) and reversed-phase high-throughput ultra high pressure liquid chromatography (UHPLC) method that uses a gradient elution and diode array detection to quantitate three biologically active flavonols in wines, myricetin, quercetin, and kaempferol, is described. In addition to performing routine experiments to establish the validity of the assay to internationally accepted criteria (selectivity, linearity, sensitivity, precision, accuracy), experiments are included to assess the effect of the important experimental parameters such as the type of sorbent material (C2, C8, C18, SIL, and C8/SCX), number of extraction cycles (extract-discard), elution volume, sample volume, and ethanol content, on the MEPS performance. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (250 μL) in five extraction cycle and in a short time period (about 5 min for the entire sample preparation step). Under optimized conditions, excellent linearity View the MathML source(Rvalues2>0.9963), limits of detection of 0.006 μg mL−1 (quercetin) to 0.013 μg mL−1 (myricetin) and precision within 0.5–3.1% were observed for the target flavonols. The average recoveries of myricetin, quercetin and kaempferol for real samples were 83.0–97.7% with relative standard deviation (RSD, %) lower than 1.6%. The results obtained showed that the most abundant flavonol in the analyzed samples was myricetin (5.8 ± 3.7 μg mL−1). Quercetin (0.97 ± 0.41 μg mL−1) and kaempferol (0.66 ± 0.24 μg mL−1) were found in a lower concentration. The optimized MEPSC8 method was compared with a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis HLB) were used as reference. MEPSC8 approach offers an attractive alternative for analysis of flavonols in wines, providing a number of advantages including highest extraction efficiency (from 85.9 ± 0.9% to 92.1 ± 0.5%) in the shortest extraction time with low solvent consumption, fast sample throughput, more environmentally friendly and easy to perform.
Resumo:
A novel analytical approach, based on a miniaturized extraction technique, the microextraction by packed sorbent (MEPS), followed by ultrahigh pressure liquid chromatography (UHPLC) separation combined with a photodiode array (PDA) detection, has been developed and validated for the quantitative determination of sixteen biologically active phenolic constituents of wine. In addition to performing routine experiments to establish the validity of the assay to internationally accepted criteria (linearity, sensitivity, selectivity, precision, accuracy), experiments are included to assess the effect of the important experimental parameters on the MEPS performance such as the type of sorbent material (C2, C8, C18, SIL, and M1), number of extraction cycles (extract-discard), elution volume, sample volume, and ethanol content, were studied. The optimal conditions of MEPS extraction were obtained using C8 sorbent and small sample volumes (250 μL) in five extraction cycle and in a short time period (about 5 min for the entire sample preparation step). The wine bioactive phenolics were eluted by 250 μL of the mixture containing 95% methanol and 5% water, and the separation was carried out on a HSS T3 analytical column (100 mm × 2.1 mm, 1.8 μm particle size) using a binary mobile phase composed of aqueous 0.1% formic acid (eluent A) and methanol (eluent B) in the gradient elution mode (10 min of total analysis). The method gave satisfactory results in terms of linearity with r2-values > 0.9986 within the established concentration range. The LOD varied from 85 ng mL−1 (ferulic acid) to 0.32 μg mL−1 ((+)-catechin), whereas the LOQ values from 0.028 μg mL−1 (ferulic acid) to 1.08 μg mL−1 ((+)-catechin). Typical recoveries ranged between 81.1 and 99.6% for red wines and between 77.1 and 99.3% for white wines, with relative standard deviations (RSD) no larger than 10%. The extraction yields of the MEPSC8/UHPLC–PDA methodology were found between 78.1 (syringic acid) and 99.6% (o-coumaric acid) for red wines and between 76.2 and 99.1% for white wines. The inter-day precision, expressed as the relative standard deviation (RSD%), varied between 0.2% (p-coumaric and o-coumaric acids) and 7.5% (gentisic acid) while the intra-day precision between 0.2% (o-coumaric and cinnamic acids) and 4.7% (gallic acid and (−)-epicatechin). On the basis of analytical validation, it is shown that the MEPSC8/UHPLC–PDA methodology proves to be an improved, reliable, and ultra-fast approach for wine bioactive phenolics analysis, because of its capability for determining simultaneously in a single chromatographic run several bioactive metabolites with high sensitivity, selectivity and resolving power within only 10 min. Preliminary studies have been carried out on 34 real whole wine samples, in order to assess the performance of the described procedure. The new approach offers decreased sample preparation and analysis time, and moreover is cheaper, more environmentally friendly and easier to perform as compared to traditional methodologies.
Resumo:
This study provides a versatile validated method to determine the total vitamin C content, as the sum of the contents of L-ascorbic acid (L-AA) and dehydroascorbic acid (DHAA), in several fruits and vegetables and its degradability with storage time. Seven horticultural crops from two different origins were analyzed using an ultrahigh-performance liquid chromatographic–photodiode array (UHPLC-PDA) system, equipped with a new trifunctional high strength silica (100% silica particle) analytical column (100 mm×2.1 mm, 1.7 μm particle size) using 0.1% (v/v) formic acid as mobile phase, in isocratic mode. This new stationary phase, specially designed for polar compounds, overcomes the problems normally encountered in HPLC and is suitable for the analysis of large batches of samples without L-AA degradation. In addition, it proves to be an excellent alternative to conventional C18 columns for the determination of L-AA in fruits and vegetables. The method was fully validated in terms of linearity, detection (LOD) and quantification (LOQ) limits, accuracy, and inter/intraday precision. Validation experiments revealed very good recovery rate of 96.6±4.4% for L-AA and 103.1±4.8 % for total vitamin C, good linearity with r2-values >0.999 within the established concentration range, excellent repeatability (0.5%), and reproducibility (1.6%) values. The LOD of the method was 22 ng/mL whereas the LOQ was 67 ng/mL. It was possible to demonstrate that L-AA and DHAA concentrations in the different horticulture products varied oppositely with time of storage not always affecting the total amount of vitamin C during shelf-life. Locally produced fruits have higher concentrations of vitamin C, compared with imported ones, but vegetables showed the opposite trend. Moreover, this UHPLC-PDA methodology proves to be an improved, simple, and fast approach for determining the total content of vitamin C in various food commodities, with high sensitivity, selectivity, and resolving power within 3 min of run analysis.
Resumo:
Este trabalho teve por objetivo estimar equações de regressão linear múltipla tendo, como variáveis explicativas, as demais características avaliadas em experimento de milho e, como variáveis principais, a diferença mínima significativa em percentagem da média (DMS%) e quadrado médio do erro (QMe), para peso de grãos. Com 610 experimentos conduzidos na Rede de Ensaios Nacionais de Competição de Cultivares de Milho, realizados entre 1986 e 1996 (522 experimentos) e em 1997 (88 experimentos), estimaram-se duas equações de regressão, com os 522 experimentos, validando estas pela análise de regressão simples entre os valores reais e os estimados pelas equações, com os 88 restantes, observando que, para a DMS% a equação não estimava o mesmo valor que a fórmula original e, para o QMe, a equação poderia ser utilizada na estimação. Com o teste de Lilliefors, verificou-se que os valores do QMe aderiam à distribuição normal padrão e foi construída uma tabela de classificação dos valores do QMe, baseada nos valores observados na análise da variância dos experimentos e nos estimados pela equação de regressão.
Resumo:
O conhecimento da variação espacial de atributos do solo pode contribuir para o planejamento e a otimização na condução de experimentos e de lavouras comerciais, objetivando a agricultura de precisão. O objetivo deste trabalho foi avaliar a necessidade de fertilizante e calcário para implantação da agricultura de precisão, com base no comportamento espacial de atributos químicos de um Latossolo após o corte da cana-planta. Os dados foram avaliados pela estatística descritiva e análise da dependência espacial, com base no ajuste de semivariogramas. As técnicas de geoestatísticas apresentam-se como ferramentas auxiliares na aplicação de fertilizantes por meio de taxa variada, detectando, para a área em estudo, que não se recomenda a aplicação de fósforo e calagem por taxa variada.
Resumo:
Currently great emphasis is given for seed metering that assist rigorous demands in relation to longitudinal distribution of seeds, as well as to the index of fails in spacing laws, breaks and double seeds. The evaluation of these variable demands much time and work of attainment of data and processing. The objective of this work went propose to use of graphs of normal probability, facilitating the treatment of the data and decreasing the time of processing. The evaluation methodology consists in the counting of broken seeds, fail spacing and double seeds through the measure of the spacing among seeds, preliminary experiments through combinations of treatments had been carried through whose factors of variation were the level of the reservoir of seeds, the leveling of the seed metering, the speed of displacement and dosage of seeds. The evaluation was carried through in two parts, first through preliminary experiments for elaboration of the graphs of normal probability and later in experiments with bigger sampling for evaluation of the influence of the factors most important. It was done the evaluation of seed metering of rotating internal ring, and the amount of necessary data for the evaluation was very decreased through of the graphs of normal probability that facilitated to prioritize only the significant factors. The dosage of seeds was factor that more important because factor (D) have greater significance.
Resumo:
In the fields of Machine Vision and Photogrammetry, extracted straight lines from digital images can be used either as vector elements of a digital representation or as control entities that allow the determination of the camera interior and exterior orientation parameters. Applications related with image orientation require feature extraction with subpixel precision, to guarantee the reliability of the estimated parameters. This paper presents three approaches for straight line extraction with subpixel precision. The first approach considers the subpixel refinement based on the weighted average of subpixel positions calculated on the direction perpendicular to the segmented straight line. In the second approach, a parabolic function is adjusted to the grey level profile of neighboring pixels in a perpendicular direction to the segmented line, followed by an interpolation of this model to estimate subpixel coordinates of the line center. In the third approach, the subpixel refinement is performed with a parabolic surface adjustment to the grey level values of neighboring pixels around the segmented line. The intersection of this surface with a normal plane to the line direction generates a parabolic equation that allows estimating the subpixel coordinates of the point in the straight line, assuming that this is the critical point of this function. Three experiments with real images were made and the approach based on parabolic surface adjustment has presented better results.