983 resultados para PCV13 (13-valent pneumococcal conjugate vaccine)
Resumo:
In a large Phase III trial conducted in 10 Latin American countries, the safety and efficacy of the live attenuated monovalent rotavirus vaccine RIX4414 was evaluated in 15,183 healthy infants followed up during the first two years of life. Belém was the only site in Brazil included in this multicentre trial. The study in Belém included a subset of 653 infants who were followed up until 24 months of age for protection against severe rotavirus gastroenteritis. These subjects were randomly assigned in a 1:1 ratio to receive two doses of vaccine (n = 328) or two doses of placebo (n = 325) at approximately two and four months of age. Of the 653 enrolled infants, 23 dropped out during the study period. For the combined two-year period, the efficacy of RIX4414 was 72.3% [95% confidence interval (CI) 37.5-89.1%] against severe rotavirus-related gastroenteritis, reaching a protection rate of 81.8% (95% CI 36.4-96.6%) against circulating wild-type G9 rotavirus strains. It is concluded that two doses of RIX4414 are highly efficacious against severe rotavirus gastroenteritis in Belém during the first two years of life and provide high protection against the worldwide emergence and spread of G9P[8] strains.
Resumo:
A vaccination campaign against pandemic influenza A (H1N1)pdm09 was held in Brazil in March 2010, using two types of monovalent split virus vaccines: an AS03-adjuvanted vaccine and a non-adjuvanted vaccine. We compared the reactogenicity of the vaccines in health professionals from a Clinical Research Institute in Rio de Janeiro, Brazil and there were no serious adverse events following immunization (AEFI) among the 494 subjects evaluated. The prevalence of any AEFI was higher in the AS03-adjuvanted vaccine at 2 h and 24 h post-vaccination [preva-lence ratio (PR): 2.05, confidence interval (CI) 95%: 1.55-2.71, PR: 3.42, CI 95%: 2.62-4.48, respectively]; however, there was no difference between the vaccines in the assessments conducted at seven and 21 days post-vaccination. The group receiving the AS03 post-adjuvanted vaccine had a higher frequency of local reactions at 2 h (PR: 3.01, CI 95%: 2.12-4.29), 24 h (PR: 4.57, CI 95%: 3.29-6.37) and seven days (PR: 6.05, CI 95%: 2.98-12.28) post-vaccination. We concluded that the two types of vaccines caused no serious AEFI in the studied population and the adjuvanted vaccine was more reactogenic, particularly in the 24 h following vaccination. This behaviour must be confirmed and better characterised by longitudinal studies in the general population.
Resumo:
The protective anti-HBs titres were examined six-year post-immunisation with the Brazilian recombinant hepatitis B vaccine. After the primary vaccination, all adolescents (n = 89) responded with protective anti-HBs titres and had a geometric mean titre (GMT) of 4031.8 mIU/mL. In 2010, 94.5% maintained protective anti-HBs (> 10 mIU/mL) antibodies, with a GMT of 236.0 mIU/mL. A positive correlation was observed between the anti-HBs titres after the primary vaccination and the titres at the six-year follow-up (p < 0.01). Eleven subjects showed anti-HBs titres suggestive of a natural booster. Prostitution and tattoos/piercings were marginally associated with natural boosters in the multivariate analysis. This study showed the first data on anti-HBs persistence following the Brazilian hepatitis B vaccine in sexually active individuals and highlights its effectiveness in the medium term.
Resumo:
Información elaborada a partir de: Proyecto de Humanización de la Atención Perinatal en Andalucía; Plan para la Promoción de la Actividad Física y la Alimentación Equilibrada; Plan Integral de Obesidad Infantil de Andalucía; Programas de Promoción de Salud Bucodental "Sonrisitas" y "Aprende a sonreir"; Plan Integral de Atención a la Accidentabilidad de Andalucía; Plan Integral de Tabaquismo de Andalucía; Plan Integral de Oncología de Andalucía. Publicado en el Portal Web de Ventana Abierta a la familia: www.juntadeandalucia.es/salud/ventanafamilias
Resumo:
Référence bibliographique : Rol, 54895
Resumo:
Référence bibliographique : Rol, 54892
Resumo:
Référence bibliographique : Rol, 54891
Resumo:
Référence bibliographique : Rol, 54890
Resumo:
Référence bibliographique : Rol, 54858
Resumo:
Boletín semanal para profesionales sanitarios de la Secretaría General de Calidad, Innovación y Salud Pública de la Consejería de Igualdad, Salud y Políticas Sociales
Resumo:
BACKGROUND/OBJECTIVES: (1) To cross-validate tetra- (4-BIA) and octopolar (8-BIA) bioelectrical impedance analysis vs dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition and (2) to evaluate the accuracy of external 4-BIA algorithms for the prediction of total body composition, in a representative sample of Swiss children. SUBJECTS/METHODS: A representative sample of 333 Swiss children aged 6-13 years from the Kinder-Sportstudie (KISS) (ISRCTN15360785). Whole-body fat-free mass (FFM) and appendicular lean tissue mass were measured with DXA. Body resistance (R) was measured at 50 kHz with 4-BIA and segmental body resistance at 5, 50, 250 and 500 kHz with 8-BIA. The resistance index (RI) was calculated as height(2)/R. Selection of predictors (gender, age, weight, RI4 and RI8) for BIA algorithms was performed using bootstrapped stepwise linear regression on 1000 samples. We calculated 95% confidence intervals (CI) of regression coefficients and measures of model fit using bootstrap analysis. Limits of agreement were used as measures of interchangeability of BIA with DXA. RESULTS: 8-BIA was more accurate than 4-BIA for the assessment of FFM (root mean square error (RMSE)=0.90 (95% CI 0.82-0.98) vs 1.12 kg (1.01-1.24); limits of agreement 1.80 to -1.80 kg vs 2.24 to -2.24 kg). 8-BIA also gave accurate estimates of appendicular body composition, with RMSE < or = 0.10 kg for arms and < or = 0.24 kg for legs. All external 4-BIA algorithms performed poorly with substantial negative proportional bias (r> or = 0.48, P<0.001). CONCLUSIONS: In a representative sample of young Swiss children (1) 8-BIA was superior to 4-BIA for the prediction of FFM, (2) external 4-BIA algorithms gave biased predictions of FFM and (3) 8-BIA was an accurate predictor of segmental body composition.
Resumo:
Référence bibliographique : Rol, 54883
Resumo:
Référence bibliographique : Rol, 54880
Resumo:
Référence bibliographique : Rol, 54864