999 resultados para Ossos do Tarso
Resumo:
Aniba canelilla (H.B.K.) Mez. is a tree species from Amazon that produces essential oil. The oil extraction from its leaves and stems can be an alternative way to avoid the tree cutting for production of essential oil. The aim of this study was to analyse factors that may influence the essential oil production and the biomass of resprouts after pruning the leaves and stems of A. canelilla trees. The tree crowns were pruned in the wet season and after nine months the leaves and stems of the remaining crown and the resprouts were collected, in the dry season. The results showed that the essential oil yield and chemical composition differed among the stems, leaves and resprouts. The stems' essential oil production differed between the seasons and had a higher production in the resprouting stems than the old stems of the remaining crown. The production of essential oil and leaf biomass of resprouts were differently related to the canopy openness, indicating that light increases the production of the essential oil and decreases the biomass of resprouting leaves. This study revealed that plant organs differ in their essential oil production and that the canopy openness must be taken into account when pruning the A. canelilla tree crown in order to achieve higher oil productivity.
Resumo:
ABSTRACTThe composition of propolis depends on time, vegetation and the location of the collection area. The objective of this study was to determine the physicochemical characteristics, the concentration of phenol compounds and the antioxidant capacity of propolis of native stingless bees (Meliponinae)and Apis from the State of Tocantins. Extraction with 80% ethanol (v/v) was performed in order to obtain the extracts. Parameters examined were: propolis mass loss by desiccation at 105 ºC, ashes, wax concentration and pH. Furthermore, the propolis antioxidant activity was measured, as well as the total concentration of phenol compounds. The extracts were also analyzed by high performance liquid chromatography. The total concentration of phenol compounds varied between 121.78 and 631.29 (mg GAE g-1). The antioxidant activity expressed by the value of CE50 varied between 29.81 and 845.38 µg mL-1. High performance liquid chromatography analysis allowed us to infer the existence of phenol compounds. The results indicated that the studied propolis samples constitute good sources of natural antioxidants. The variety of phenol compounds identified in this study, and the diverse biological functions reported in literature for these compounds indicated that this stingless bee propolis (Meliponinae) and Apis has a high pharmacological potential.
Resumo:
Objective To investigate the relation between gait parameters and cognitive impairments in subjects with Parkinson’s disease (PD) and Alzheimer’s disease (AD) during the performance of dual tasks. Methods This was a cross-sectional study involving 126 subjects divided into three groups: Parkinson group (n = 43), Alzheimer group (n = 38), and control group (n = 45). The subjects were evaluated using the Timed Up and Go test administered with motor and cognitive distracters. Gait analyses consisted of cadence and speed measurements, with cognitive functions being assessed by the Brief Cognitive Screening Battery and the Clock Drawing Test. Statistical procedures included mixed-design analyses of variance to observe the gait patterns between groups and tasks and the linear regression model to investigate the influence of cognitive functions in this process. A 5% significant level was adopted. Results Regarding the subjects’ speed, the data show a significant difference between group vs task interaction (p = 0.009), with worse performance of subjects with PD in motor dual task and of subjects with AD in cognitive dual task. With respect to cadence, no statistical differences was seen between group vs task interaction (p = 0.105), showing low interference of the clinical conditions on such parameter. The linear regression model showed that up to 45.79%, of the variance in gait can be explained by the interference of cognitive processes. Conclusion Dual task activities affect gait pattern in subjects with PD and AD. Differences between groups reflect peculiarities of each disease and show a direct interference of cognitive processes on complex tasks.
Resumo:
OBJECTIVE: To describe a new more efficient method of endocardial cardiac stimulation, which produces a narrower QRS without using the coronary sinus or cardiac veins. METHODS: We studied 5 patients with severe dilated cardiomyopathy, chronic atrial fibrillation and AV block, who underwent definitive endocardial pacemaker implantation, with 2 leads, in the RV, one in the apex and the other in the interventricular septum (sub pulmonary), connected, respectively, to ventricular and atrial bicameral pacemaker outputs. Using Doppler echocardiography, we compared, in the same patient, conventional (VVI), high septal ("AAI") and bifocal ("DDT" with AV interval ~ 0) stimulation. RESULTS: The RV bifocal stimulation had the best results with an increase in ejection fraction and cardiac output and reduction in QRS duration, mitral regurgitation and in the left atrium area (p <= 0.01). The conventional method of stimulation showed the worst result. CONCLUSION: These results suggest that, when left ventricular stimulation is not possible, right ventricular bifocal stimulation should be used in patients with severe cardiomyopathy where a pacemaker is indicated.
Resumo:
OBJECTIVE: To assess the prevalence of white-coat normortension, white-coat hypertension, and white-coat effect. METHODS: We assessed 670 medical records of patients from the League of Hypertension of the Hospital das Clínicas of the Medical School of the University of São Paulo. White-coat hypertension (blood pressure at the medical office: mean of 3 measurements with the oscillometric device ³140 or ³90 mmHg, or both, and ambulatory blood pressure monitoring mean during wakefulness < 135/85) and white-coat normotension (office blood pressure < 140/90 and blood pressure during wakefulness on ambulatory blood pressure monitoring ³ 135/85) were analyzed in 183 patients taking no medication. The white-coat effect (difference between office and ambulatory blood pressure > 20 mmHg for systolic and 10 mmHg for diastolic) was analyzed in 487 patients on treatment, 374 of whom underwent multivariate analysis to identify the variables that better explain the white-coat effect. RESULTS: Prevalence of white-coat normotension was 12%, prevalence of white-coat hypertension was 20%, and prevalence of the white-coat effect was 27%. A significant correlation (p<0.05) was observed between white-coat hypertension and familial history of hypertension, and between the white-coat effect and sex, severity of the office diastolic blood pressure, and thickness of left ventricular posterior wall. CONCLUSION: White-coat hypertension, white-coat normotension, and white-coat effect should be considered in the diagnosis of hypertension.
Resumo:
OBJETIVO: Observar a influência de quatro meses de um programa domiciliar não-supervisionado de exercícios sobre a pressão arterial (PA) e aptidão física em hipertensos. MÉTODOS: Foram observados um grupo experimental com 26 homens e 52 mulheres e um grupo controle, com 9 homens e 7 mulheres, com idades entre 25 e 77 anos. O grupo experimental submeteu-se a um programa domiciliar de exercícios, com atividades aeróbias (60-80% da FC máxima para a idade, 30min de caminhadas no mínimo três vezes por semana), exercícios de flexibilidade. Orientações sobre a ficha de controle e o treinamento eram dadas a cada reavaliação. Foram acompanhados por quatro meses, com reavaliações a cada dois meses, observando-se: PA em repouso; peso corporal, relação cintura-quadril (RCQ), percentual de gordura (%G), somatório de dobras cutâneas (SOMD) e relação central e periférica de dobras (P/C); flexibilidade de tronco (FX); relação entre freqüência cardíaca e carga de trabalho durante teste submáximo em ciclo-ergômetro (FC/W), traduzida pela inclinação da curva de regressão entre ambas (a). RESULTADOS: O grupo experimental exibiu alterações significativas para o peso (-3,7 kg), RCQ (-0,03), SOMD (-12 mm), %G (-4,4%), FX (+2,3 cm), FC/W (-0,02) e PA (-6 e -9 mmHg para pressão sistólica e diastólica, respectivamente). O grupo controle teve pequenas alterações no peso (+1,3 Kg) e %G (+1,7%). CONCLUSÃO: Programas domiciliares não supervisionados de exercícios, podem exercer efeito positivo sobre a PA e aptidão física de hipertensos.
Resumo:
OBJETIVO: Pretende-se avaliar em pacientes com cardiomiopatia hipertrófica e risco de MSC, submetidos a implante de cardioversor-desfibrilador implantável (CDI): a) ocorrência de eventos arrítmicos; b) ocorrência de eventos clínicos e correlações com eventos arrítmicos; c) ocorrência de terapia de choque do CDI e correlações clínico-funcionais; d) preditores clínico-funcionais de prognóstico. MÉTODOS: Foram estudados 26 pacientes com cardiomiopatia hipertrófica e fatores de risco de MSC, submetidos a implante de CDI no período de maio de 2000 a janeiro de 2004 (seguimento médio = 20 meses). Quatorze pacientes (53,8%) eram do sexo feminino e a idade média foi de 42,7 anos. Em 16 pacientes (61,5%), a indicação do CDI foi para prevenção primária de morte súbita cardíaca, e em 10 (38,5%), para prevenção secundária. Vinte pacientes (76,9%) apresentavam síncope prévia ao implante de CDI, metade desses relacionados a fibrilação ventricular ou taquicardia ventricular sustentada; 15 (57,7%) tinham história de morte súbita familiar; 12 pacientes (46,2%), taquicardia ventricular não-sustentada ao Holter de 24 horas; e 5 (19,2%) apresentavam o septo interventricular com espessura maior que 30 mm. RESULTADOS: No seguimento foram registrados no CDI 4 terapias de choque em arritmias potencialmente letais (3 pacientes com taquicardia ventricular sustentada e 1 paciente com fibrilação ventricular). Ocorreu um óbito por provável acidente vascular cerebral tromboembólico. Quatro pacientes tiveram recorrência de síncope sem evento arrítmico registrado pelo CDI. A análise estatística demonstrou significância da precocidade do choque do CDI em pacientes cujo septo interventricular tinha espessura maior que 30 mm. CONCLUSÃO: 1- ocorrência de eventos arrítmicos em 50% dos pacientes: a maioria (62%) foi taquicardia ventricular, sustentada (31%) e não-sustentada (31%); nos outros pacientes ocorreu taquicardia paroxística supraventricular; 2- síncopes recorrentes na minoria dos pacientes (16%), que, entretanto, não se associaram à presença de eventos arrítmicos; 3- presença de septo interventricular superior a 30 mm, ao ecocardiograma, se associou à ocorrência de terapia de choque precoce (p = 0,003); 4- ausência de preditores clínicos ou funcionais.
Resumo:
OBJETIVO: O presente estudo analisou a concordância entre as estimativas do débito cardíaco (Q) geradas por dois métodos indiretos e sua aplicabilidade em 54 homens e 77 mulheres (60-90 anos). MÉTODOS: Os indivíduos realizaram um teste cardiopulmonar de exercício progressivo máximo em ciclo-ergômetro. O Q foi estimado a partir do consumo de oxigênio e da impedância cardiográfica a 50% e 100% da carga máxima alcançada no teste (Wmáx). Os limites de concordância e as diferenças médias (vieses) foram avaliados segundo a metodologia proposta por Bland e Altman, enquanto a relação entre os métodos foi analisada por regressão linear e correlação intraclasse (ICC). RESULTADOS: Na carga equivalente a 50% Wmáx, a diferença entre as médias dos métodos foi de -0,58 Lmin-1 (6,3% menor para a medida da impedância), e o limite de concordância de ± 2,54 Lmin-1 (24,7%). Em 100% Wmáx, a diferença foi de 1,03 Lmin-1 (8,5% maior para a medida da impedância), com um limite de concordância de ± 3,35 Lmin-1 (27,6%). Os valores de ICC e as curvas de regressão obtidas entre os métodos foram: Qimp=1,82+0,75Q VO2 (r²=0,765, p<0,001; ICC=0,727, p<0,01) para 50% Wmáx; Qimp=0,93+1,00Q VO2 (r²=0,755, p<0,001; ICC=0,796, p<0,01) para 100% Wmáx. CONCLUSÃO: Os resultados sugerem uma boa concordância na estimativa do Q no exercício em idosos pelos dois métodos, o que se revela compatível com os achados de estudos similares com indivíduos jovens.
Resumo:
FUNDAMENTO: O exercício de força pode proporcionar significativas respostas cardiovasculares durante sua execução, sendo interessante traçar estratégias para reduzí-las sem comprometer a produção de força. OBJETIVO: Comparar as respostas cardiovasculares agudas de pressão arterial sistólica (PAS), diastólica (PAD), freqüência cardíaca (FC) e duplo-produto (DP) durante a extensão unilateral de joelho (quatro séries de oito repetições máximas) realizada de forma contínua ou fracionada. Ambos os protocolos envolveram 2 minutos (min) de intervalo entre as séries, e no protocolo fracionado foi adicionada uma pausa de 2 segundos (s) entre a 4ª e a 5ª repetições. MÉTODOS: Oito homens saudáveis e treinados em força muscular (26± 6 anos) participaram da coleta de dados, aleatoriamente divididos em dois dias não-consecutivos. As respostas cardiovasculares foram medidas por fotopletismografia (Finapres) em repouso, ao término de cada série e 2 min após a execução de cada protocolo. RESULTADOS: A série fracionada acusou valores significativamente mais elevados que o protocolo de série contínua para: PAS (mmHg) na 2ª (173,1± 5,4 vs 152,0± 4,0; p=0,001), 3ª (188,9± 8,6 vs 162,4± 6,0; p=0,000) e 4ª série (193,1± 8,1 vs 161,6± 5,9; p=0,000); PAD (mmHg) na 3ª (103,8± 4,1 vs 86,1± 3,3; p=0,000) e 4ª série (104,1± 2,7 vs 83,4± 3,3; p=0,000); DP (mmHg.bpm) na 2ª (17.907,5± 1.350,7 vs 14.541,9± 1.848,0; p=0,03), 3ª (19.687,3± 1.444,3 vs 15.612,1± 1.180,3; p=0,008) e 4ª série (21.271,0± 1.794,2 vs 15.992,0± 1.093,4; p=0,001). CONCLUSÃO: O protocolo fracionado proporcionou maior elevação das respostas pressóricas que o protocolo contínuo. No entanto, pelas características do delineamento adotado, são necessários outros estudos para confrontar esses achados.
Resumo:
FUNDAMENTO: O controle das respostas cardiovasculares durante exercício resistido (ER) é importante para a segurança do paciente. OBJETIVO: Investigar a influência do número de repetições máximas (RM) e dos intervalos de recuperação entre séries (IR) sobre a frequência cardíaca (FC), pressão arterial sistólica (PAS) e duplo produto (DP) durante ER. MÉTODOS: Vinte sujeitos saudáveis (26 ± 5 anos) realizaram protocolos de ER envolvendo três séries do leg press (6 e 12 RM) e IR proporcional ao tempo de contração (1:3 e 1:5). Aferiu-se a FC continuamente com cardiofrequencímetro e a PAS foi verificada ao final das séries, por meio de protocolo validado com método auscultatório. RESULTADOS: A FC sofreu influência da carga (p = 0,008) e das séries (p < 0,001), mas não do IR (p = 0,087). A PAS sofreu efeito isolado do número de séries (p < 0,001) e do IR (p = 0,017), mas não da carga (p = 0,95). O DP elevou-se em relação direta com a carga (p = 0,036) e com as séries (p < 0,001), mas inversamente ao IR (p = 0,006). Nos protocolos de 6 RM, a variação da FC foi maior para IR = 1:3 (Δ = 11,2 ± 1,1 bpm) do que para IR = 1:5 (Δ = 4,5 ± 0,2 bpm; p = 0,002), mas não houve diferença para 12 RM (Δ 1:3 = 21,1 ± 2,2 bpm; Δ 1:5 = 18,9 ± 2,0 bpm, p = 0,83). O IR influenciou a variação da PAS em todas as cargas (6 RM - Δ 1:3 = 10,6 ± 0,9 mmHg, Δ 1:5 = 6,6 ± 0,7 mmHg; p = 0,02 e 12 RM - Δ 1:3 = 15,2 ± 1,1 mmHg, Δ 1:5 = 8,4 ± 0,7 mmHg; p = 0,04). O DP elevou-se proporcionalmente à carga (p = 0,036) e para séries (p < 0,001), mas inversamente ao IR (p = 0,006). Com IR = 1:3, houve diferença de DP para 6 RM (Δ = 2.892 ± 189 mmHg.bpm) e 12 RM (Δ = 4.587 ± 300 mmHg.bpm; p = 0,018), mas não com IR = 1:5 (6 RM: Δ = 1.224 ± 141 mmHg.bpm, 12 RM: Δ = 2.332 ± 194 mmHg.bpm; p = 0,58). CONCLUSÃO: Independentemente da carga, um maior IR associou-se a menores respostas cardiovasculares durante ER, especialmente de PAS.