985 resultados para Oil well pumps
Resumo:
A previously healthy seven-year-old boy was admitted to the intensive care unit because of toxaemia associated with varicella. He rapidly developed shock and multisystem organ failure associated with the appearance of a deep-seated soft tissue infection and, despite aggressive treatment, died on hospital day 4. An M-non-typable, spe A and spe B positive Group A Streptococcus was cultured from a deep soft tissue aspirate. The criteria for defining Streptococcal toxic shock-like syndrome were fulfilled. The authors discuss the clinical and pathophysiological aspects of this disease as well as some unusual clinical findings related to this case.
Resumo:
Com as variações e instabilidade dos preços do petróleo, assim como as políticas europeias para adoção de estratégias para o desenvolvimento sustentável, têm levado à procura de forma crescente de novas tecnologias e fontes de energia alternativas. Neste contexto, tem-se assistido a políticas energéticas que estimulam o aumento da produção e a utilização do gás natural, visto que é considerado uma fonte de energia limpa. O crescimento do mercado do gás natural implica um reforço significativo das redes de transporte deste combustível, quer ao nível do armazenamento e fornecimento, quer ao nível dos gasodutos e da sua gestão. O investimento em gasodutos de transporte implica grandes investimentos, que poderiam não ser remunerados da forma esperada, sendo um dos motivos para que exista em Portugal cinco distritos se veem privados deste tipo de infraestruturas. O transporte de gás natural acarreta custos elevados para os consumidores, tanto maiores quanto maior forem as quantidades de gás transacionadas e quanto maior for o percurso pelo gás natural percorrido. Assim assume especial importância a realização de um despacho de gás natural: quais as cargas que cada unidade de fornecimento de gás irá alimentar, qual a quantidade de gás natural que cada UFGs deve injetar na rede, qual o menor percurso possível para o fazer, o tipo de transporte que será utilizado? Estas questões são abordadas na presente dissertação, por forma a minimizar a função custo de transporte, diminuindo assim as perdas na rede de alta pressão e os custos de transporte que serão suportados pelos consumidores. A rede de testes adotada foi a rede nacional de transporte, constituída por 18 nós de consumos, e os tipos de transporte considerados, foram o transporte por gasoduto físico e o transporte através de gasoduto virtual – rotas de transporte rodoviário de gás natural liquefeito. Foram criados diversos cenários, baseados em períodos de inverno e verão, os diferentes cenários abrangeram de forma distinta as variáveis de forma a analisar os impactos que estas variáveis teriam no custo relativo ao transporte de gás natural. Para dar suporte ao modelo de despacho económico, foi desenvolvida uma aplicação computacional – Despacho_GN com o objetivo de despachar as quantidades de gás natural que cada UFG deveria injetar na rede, assim como apresentar os custos acumulados relativos ao transporte. Com o apoio desta aplicação foram testados diversos cenários, sendo apresentados os respectivos resultados. A metodologia elaborada para a criação de um despacho através da aplicação “Despacho_GN” demonstrou ser eficiente na obtenção das soluções, mostrando ser suficientemente rápida para realizar as simulações em poucos segundos. A dissertação proporciona uma contribuição para a exploração de problemas relacionados com o despacho de gás natural, e sugere perspectivas futuras de investigação e desenvolvimento.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Computational Logic
Resumo:
No âmbito do desenvolvimento da dissertação do Mestrado de Engenharia Eletrotécnica – Sistemas Elétricos de Energia, surgiu a oportunidade de participar no desenvolvimento de um projeto integrante numa subestação de energia. O presente caso de estudo tem em vista a resolução de condicionantes na conceção desta subestação, tais como cumprir requisitos estéticos projetando todo o tipo de equipamentos dentro de edifícios, a ventilação das salas de transformação assim como insonorização de todo o ruído produzido de forma a cumprir os limites legais e não perturbar a vizinhança. A presente subestação de energia está situada numa zona urbana da cidade de Leiria, localidade de Parceiros, dando origem ao nome Subestação de Energia de Parceiros. Esta subestação pertence ao cliente Energias de Portugal, conhecida como EDP, e visa o melhoramento da distribuição do serviço eléctrico. As tradicionais subestações de energia, com aparência bastante desenquadrada dos meios urbanos, representam um entrave ao nível da aproximação destes centros de produção energética às zonas urbanas, comprometendo a melhoria da rede elétrica. Desta forma, foi implementada a tecnologia Gas-Insolated Switchgear e permite o enquadramento destes centros energéticos em zonas urbanas, constituindo mais um edifício urbano na zona onde se insere. Esta substitui os convencionais barramentos existentes nos Parques Exteriores de Aparelhagem das subestações e apresenta-se com dimensões muito reduzidas quando comparadas com as estruturas instaladas nestes parques. Dado que esta tecnologia é desenvolvida no sentido de permitir a construção destes centros energéticos em zonas urbanas, podem ser alojadas dentro de edifícios produzindo assim vantagens ao nível estético, não perturbando a paisagem. Dado que os principais equipamentos de funcionamento na subestação de Parceiros, nomeadamente o Transformador de Potência, se encontram instalados num edifício completamente fechado, foram construídas duas salas de ventilação, na parte superior deste edifício, cada uma adjacente a uma sala de transformação. O transformador instalado possui elevadas dimensões, pesando 53000 kg e contendo 11000 kg de óleo que em estado normal de funcionamento circula por quase todo o interior da máquina a elevadas temperaturas, provocando um aquecimento elevado no interior do edifício o que condiciona o bom funcionamento do transformador. Para ultrapassar esta condicionante foi realizado um estudo de um sistema de ventilação capaz de avaliar e controlar os valores térmicos existentes e proceder à circulação de ar, que será movimentado ou bloqueado, recorrendo a um sistema autónomo, mantendo a temperatura ideal nas salas de transformação. Este autómato é o cérebro de toda a cadeia lógica que, mediante as leituras efetuadas irá dar ordens de atuação aos diversos equipamentos. Apesar dos TP estarem protegidos dentro do edifício, estes produzem um maior ruído. A necessidade da existência do referido sistema de ventilação das divisões de funcionamento destas máquinas, implica a utilização de aparelhos que, apesar da sua evolução tecnológica os torna cada vez menos ruidosos, mas geram sempre alguma perturbação, o que pode representar um problema no cumprimento do regulamento geral do ruído.
Resumo:
Os Transformadores de potência são máquinas de elevada importância ao nível dos Sistemas Elétricos de Energia (SEE) uma vez que são estas máquinas que possibilitam a interligação dos diferentes níveis de tensão da rede e a transmissão de energia elétrica em Corrente Alternada (CA). Geralmente, estas máquinas são de grandes dimensões e de elevado nível de complexidade construtiva. Caracterizam-se por possuírem períodos de vida útil bastante elevados (vinte a trinta anos) e preços elevados, o que conduz a um nível de exigência de fiabilidade muito elevada, uma vez que não e viável a existência de muitos equipamentos de reserva nos SEE. Com o objetivo de tentar maximizar o período de vida útil dos transformadores de potência e a sua fiabilidade, tenta-se, cada vez mais, implementar conceitos de manutenção preventiva a este tipo de máquinas. No entanto, a gestão da sua vida útil e extremamente complexa na medida em que, estas máquinas têm vários componentes cruciais e suscetiveis de originar falhas e, quase todos eles, encontram-se no interior de uma cuba. Desta forma, não e possível obter uma imagem do seu estado, em tempo real, sem colocar o transformador fora de serviço, algo que acarreta custos elevados. Por este motivo, desenvolveu-se uma técnica que permite obter uma indicação do estado do transformador, em tempo real, sem o retirar de serviço, colhendo amostras do óleo isolante e procedendo a sua análise físico-química e Analise Gases Dissolvidos (DGA). As análises aos óleos isolantes tem vindo a adquirir uma preponderância muito elevada no diagnóstico de falhas e na analise do estado de conservação destes equipamentos tendo-se desenvolvido regras para interpretação dos parâmetros dos óleos com carácter normativo. Considerando o conhecimento relativo a interpretação dos ensaios físico-químicos e DGA ao oleol, e possível desenvolver ferramentas capazes de otimizar essas mesmas interpretações e aplicar esse conhecimento no sentido de prever a sua evolução, assim como o surgimento de possíveis falhas em transformadores, para assim otimizar os processos de manutenção. Neste campo as Redes Neuronais Artificiais (RNAs) têm um papel fundamental
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
Este documento especifica o trabalho realizado no estágio, que decorreu na Colquímica, sediada em Valongo. Este trabalho teve como objetivo colaborar no desenvolvimento de uma cola com características biodegradáveis. O estágio foi orientado pela Engenheira Cristina Frutuoso, no que diz respeito à orientação por parte da Colquímica, e pelo Professor Dr. Gilberto Pinto e Alfredo Crispim, ISEP. O trabalho foi dividido em duas instâncias, sendo a primeira direcionada para a formulação de uma cola com características biodegradáveis e a segunda para a realização do teste de Sturm, um teste de biodegradabilidade capaz de quantificar a quantidade de CO2 produzido pelo processo de biodegradação. Inicialmente foram desenvolvidas e estudadas dez formulações através das variações de resinas e óleo plastificante e estudado o seu comportamento reológico relacionado à variação de viscosidade em função da temperatura. Com base nos resultados obtidos verificou-se que a melhor formulação seria a A8. Estudaram-se as propriedades mecânicas da formulação escolhida e decidiu-se que esta estaria apta a ser usada no fecho de caixas de cartão de produtos ultra congelados assim como no fecho de caixas de cartão de detergentes em pó com peso até 3 Kg. Depois de escolhida a formulação deu-se início ao teste de Sturm, teste meramente orientativo. Durante dezassete dias avaliou-se a quantidade de CO2 produzida durante o processo de biodegradação. Após avaliação dos resultados verificou-se que a taxa de biodegradação para a amostra foi de 0,055 g de CO2. Com a finalidade de confirmar os resultados obtidos no teste de Sturm foi efetuada uma réplica do ensaio, a qual se encontra a decorrer sendo os resultados facultados, posteriormente, à empresa.
Resumo:
DEET (N,N-diethyl-3-methylbenzamide) is nowadays the most effective mosquito repellent available, however, its use can present some topical and systemic side effects. Some botanical compositions, as Andiroba (Carapa guianensis), have been proved repellent properties at low cost and toxicity. An experimental study was driven involving four volunteers submitting their forearms covered with Andiroba oil at 100%, DEET 50%, refined soy oil, Andiroba oil 15% and in the absence of products, directly to healthy females of Aedes sp. The times of first and third bites were checked. The results showed that the median of the first bite without any product was 17.5s and the third bite, 40.0s. In the soy oil, the bites happened in 60.0s and 101.5s, in the presence of Andiroba oil 100%, in 56.0s and 142.5s and in Andiroba oil 15%, in 63.0s and 97.5s. The volunteers using DEET 50% had not received bites after 3600s in most of the experiments (p < 0.001 Wilcoxon). Pure Andiroba oil compared to the soy oil, forearm without product and Andiroba oil 15%, showed discreet superiority (p < 0.001 Wilcoxon). Our conclusion is that this study demonstrated that the pure Andiroba oil presents discreet repellent effect against bite of Aedes sp., being significantly inferior to DEET 50%.
Resumo:
The ultrastructural superficial changes in third instar house fly (Musca domestica) and blow fly (Chrysomya megacephala) induced by eucalyptol oil were observed using scanning electron microscopy. Dipped in 0.902 g/ml eucalyptol for 30 sec, the larvae integument of both species showed significant aberrant appearance of the body surface, particularly swelling integument, bleb formation, partial breach and deformation of spines.
Resumo:
Spinal arachnoiditis, an inflammatory process involving all three meningeal layers as well as the nerve roots, is a cause of persistent symptoms in 6% to 16% of postoperative patients. Although spinal surgery is the most common antecedent associated with arachnoiditis, multiple causes have been reported, including infection, intrathecal steroids or anesthetic agents, trauma, subarachnoid hemorrhage and ionic myelographic contrast material--both oil soluble and water soluble. In the past, oil-based intrathecal contrast agents (Pantopaque) were associated with arachnoiditis especially when this material was introduced into the thecal sac and mixed with blood. Arachnoiditis is apparently rarely idiopathic. The pathogenesis of spinal arachnoiditis is similar to the repair process of serous membranes, such as the peritoneum, with a negligible inflammatory cellular exudate and a prominent fibrinous exudate. Chronic adhesive arachnoiditis of the lower spine is a myelographic diagnosis. The myelographic findings of arachnoiditis were divided into two types by Jorgensen et al. In type 1, "the empty thecal sac" appearance, there is homogeneous filling of the thecal sac with either absence of or defects involving nerve root sleeve filling. In type 2 arachnoiditis, there are localized or diffuse filling defects within the contrast column. MRI has demonstrated a sensitivity of 92% and a specificity of 100% in the diagnosis of arachnoiditis. The appearance of arachnoiditis on MRI can be assigned to three main groups. The MRI findings in group I are a conglomeration of adherent roots positioned centrally in the thecal sac. Patients in group II show roots peripherally adherent to the meninges--the so called empty sac. MRI findings in group III are a soft tissue mass within the subarachnoid space. It corresponds to the type 2 categorization defined by Jorgensen et al, where as the MRI imaging types I and II correspond to the myelographic type 1.
Resumo:
A cidade do Porto é uma das regiões do país onde é importante uma gestão sustentável e integrada dos recursos hídricos. A (re) utilização de água surge neste contexto como uma possível resposta na sua utilização como um recurso hídrico passível de ser usado beneficamente, permitindo a poupança de fontes de água convencionais e aumentando a disponibilidade dos recursos hídricos existentes para finalidades que requerem padrões de qualidade mais exigentes. O potencial desta prática no nosso país é enorme, considerando que o volume de água tratada descarregada no ano 2000 era suficiente para suprir 10% das necessidades em água para rega num ano seco, sem necessidade de armazenamento sazonal. Por outro lado, um sistema de rega, quando devidamente projetado e funcionando adequadamente, permite que a água seja aplicada com um caudal, duração e frequência que maximizam o consumo da água e nutrientes pela planta. Este projeto consiste no desenvolvimento de um Sistema de Gestão Técnica para o controlo do sistema de rega dos jardins do ISEP – Instituto Politécnico de Engenharia do Porto com recurso a um autómato programável (PLC). Pretende-se otimizar os consumos energéticos do sistema de rega tendo em conta os parâmetros de humidade, temperatura e velocidade do vento característicos do local a regar. Outros dos objetivos é controlar o processo de enchimento e de rega. Esta operação consiste no controlo das bombas e respetivos débitos e conhecimento dos caudais necessários. Pretende-se, igualmente, definir e colocar em marcha todo o equipamento necessário para a realização do projeto. Os dados coletados devem ser tratados de tal modo que possam ser realizadas análises diárias, mensais e/ou anuais. Neste trabalho foram efetuados os cálculos de dimensionamentos relativamente às necessidades hídricas da planta e necessidades de rega, entre outros.
Resumo:
A cidade do Porto é uma das regiões do país onde é importante uma gestão sustentável e integrada dos recursos hídricos. A (re) utilização de água surge neste contexto como uma possível resposta na sua utilização como um recurso hídrico passível de ser usado beneficamente, permitindo a poupança de fontes de água convencionais e aumentando a disponibilidade dos recursos hídricos existentes para finalidades que requerem padrões de qualidade mais exigentes. O potencial desta prática no nosso país é enorme, considerando que o volume de água tratada descarregada no ano 2000 era suficiente para suprir 10% das necessidades em água para rega num ano seco, sem necessidade de armazenamento sazonal. Por outro lado, um sistema de rega, quando devidamente projetado e funcionando adequadamente, permite que a água seja aplicada com um caudal, duração e frequência que maximizam o consumo da água e nutrientes pela planta. Este projeto consiste no desenvolvimento de um Sistema de Gestão Técnica para o controlo do sistema de rega dos jardins do ISEP – Instituto Politécnico de Engenharia do Porto com recurso a um autómato programável (PLC). Pretende-se otimizar os consumos energéticos do sistema de rega tendo em conta os parâmetros de humidade, temperatura e velocidade do vento característicos do local a regar. Outros dos objetivos é controlar o processo de enchimento e de rega. Esta operação consiste no controlo das bombas e respetivos débitos e conhecimento dos caudais necessários. Pretende-se, igualmente, definir e colocar em marcha todo o equipamento necessário para a realização do projeto. Os dados coletados devem ser tratados de tal modo que possam ser realizadas análises diárias, mensais e/ou anuais. Neste trabalho foram efetuados os cálculos de dimensionamentos relativamente às necessidades hídricas da planta e necessidades de rega, entre outros.
Resumo:
O presente trabalho pretende mostrar que a aplicação de medidas de conservação de energia (MCE) pode representar uma redução da intensidade de utilização de matérias-primas na construção de um edifício. Mais concretamente, pode representar uma redução da utilização de materiais e equipamentos, e como consequência, uma redução no esforço económico ao primeiro investimento. Podendo posteriormente representar uma redução na utilização de energia durante o período de funcionamento do edifício. A aplicação de MCE no sector da construção tem vindo a ser uma prática corrente nos novos edifícios e edifícios sujeitos a grandes intervenções de reabilitação. Esta prática deve-se à obrigatoriedade de cumprimento de requisitos regulamentares aplicados à otimização do desempenho energético dos edifícios e dos seus sistemas técnicos, nomeadamente, o RCCTE e o RSECE, entretanto revogados pelo REH e pelo RECS, respetivamente. A implementação de MCE apresenta, na maioria dos casos, benefícios económicos para o promotor do edifício, uma vez que se traduz muitas vezes, na otimização do dimensionamento dos sistemas de Aquecimento, Ventilação e Ar Condicionado (AVAC). Esta otimização permite reduzir os custos associados ao primeiro investimento, bem como na utilização de energia por parte do utilizador, logo na redução dos custos de exploração. No entanto, a falta de quantificação dos impactos do dimensionamento dos sistemas AVAC, da redução de utilização de energia e da análise do custo-benefício da sua aplicação pode condicionar o interesse na sua implementação. Neste contexto, surge a presente dissertação, por iniciativa do Instituto Soldadura e Qualidade (ISQ), aplicado a um caso prático de um edifício já construído e propriedade daquela empresa. Com este trabalho pretende-se avaliar o contributo efetivo das MCE implementadas na fase de projeto e na fase de construção, quer na otimização da dimensão de sistemas e equipamentos AVAC, por via da redução das necessidades energéticas, quer na redução de utilização de energia, permitindo, de seguida, uma avaliação custo-benefício.Na base do caso de estudo está o ECOTERMOLAB, o edifício acima referido, adquirido pelo ISQ para instalação de um laboratório de formação, investigação e desenvolvimento na área da energia. Após aquisição pelo ISQ, o edifício sofreu várias alterações/beneficiações, entre as quais a implementação de MCE, tais como, a aplicação de isolamento térmico na envolvente opaca (paredes, pavimentos e coberturas), duplicação dos vãos envidraçados simples, conferindo-lhes melhores caraterísticas térmicas, e pela aplicação de proteções solar. Foram ainda adotadas MCE aos sistemas AVAC, designadamente, pela adoção de recuperadores de calor nas Unidades de Tratamento de Ar Novo (UTAN’s) e de variadores de velocidade nas bombas de circulação de água e nos ventiladores de ar das UTAN’s. Pretendia o ISQ concluir se a aplicação de todas as MCE contribuiu de forma efetiva para o dimensionamento de sistemas e equipamentos AVAC de menor capacidade e, consequentemente, numa redução de utilização de energia. Em sequência, pretendia avaliar a viabilidade económica da aplicação de todas as MCE, estimando o sobrecusto inicial e o tempo necessário para o retorno financeiro daquele investimento. Para alcançar os objetivos propostos, procedeu-se à simulação energética dinâmica do ECOTERMOLAB, utilizando o programa EnergyPlus. Primeiro foi simulada uma situação base do edifício, sem quaisquer MCE. Posteriormente foi caraterizada cada uma das situações de aplicação das MCE, com o objetivo de avaliar o respetivo impacto individual na utilização de energia pelos sistemas AVAC. Por último foram assumidas todas as soluções em conjunto para avaliar o impacto final de todas as MCE na utilização de energia dos sistemas AVAC, bem como no seu dimensionamento. Das simulações dinâmicas foram obtidos os valores das necessidades de aquecimento e arrefecimento, de energia utilizada pelos sistemas AVAC e de caudais de água aquecida e arrefecida circulada. Com estes valores foi feita uma estimativa de dimensionamento dos equipamentos e componentes AVAC para as situações da aplicação de todas as MCE no ECOTERMOLAB e a sua ausência. A partir da diferença dos custos de aquisição dos respetivos equipamentos e dos valores de poupança em energia foi realizado o estudo da viabilidade económica da implementação das MCE neste edifício. Este estudo permitiu concluir que a aplicação das MCE no ECOTERMOLAB levou à redução da dimensão na generalidade dos equipamentos e componentes AVAC. Permitiu, ainda, concluir que houve uma diminuição de utilização de energia por parte destes sistemas e equipamentos para o aquecimento e arrefecimento. Conclui-se ainda que o período de retorno (Payback) do sobrecusto inicial, estimado em 37.822€ é de, aproximadamente, onze anos e meio, para um valor atual líquido (VAL) de 8.061€ e à taxa interna de rentabilidade (TIR) de 7,03%.
Resumo:
To date, there are no vaccines against Leishmania, and chemotherapy remains the mainstay for the control of leishmaniasis. The drugs of choice used for leishmaniasis therapy are significantly toxic, expensive and with a growing frequency of refractory infections. Because of these limitations, a combination therapy is the better hope. This work demonstrates that the essential oil from Chenopodium ambrosioides shows a synergic activity after incubation in conjunction with pentamidine against promastigotes of Leishmania amazonensis. However, an indifferent effect has been found for combinations of meglumine antimoniate or amphotericin B and the essential oil.
Resumo:
Steam distillation of essential oils of aerial parts of Thymus capitatus and Marrubium vulgare L. collected at North cost of Egypt yielded 0.5% and 0.2%, respectively. Results of Gas chromatography-mass spectrometry analyses of the two samples identified 96.27% and 90.19% of the total oil composition for T. capitatus and M. vulgare, respectively. The two oil samples appeared dominated by the oxygenated constituents (88.22% for T. capitatus and 57.50% for M. vulgare), composed of phenols, mainly carvacrol (32.98%) and thymol (32.82%) in essential oil of T. capitatus, and thymol (34.55%) in essential oil of M. vulgare. It was evaluated the molluscicidal activity of T. capitatus and M. vulgare essential oils on adult and eggs of Biomphalaria alexandrina as well as their mosquitocidal activity on Culex pipiens. The LC50 and LC90 of T. capitatus essential oil against adult snails was 200 and 400 ppm/3hrs, respectively, while for M. vulgare it was 50 and 100 ppm/3hrs, respectively. Moreover, M. vulgare showed LC100 ovicidal activity at 200 ppm/24 hrs while T. capitatus oil showed no ovicidal activity. It was verified mosquitocidal activity, with LC50 and LC90 of 100 and 200 ppm/12hrs respectively for larvae, and 200 and 400 ppm/12hrs respectively for pupae of C. pipiens.