995 resultados para NOISE EXPOSURE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using both conventional and confocal laser scanning microscopy with three monoclonal antibodies recognizing nuclear matrix proteins we have investigated by means of indirect fluorescence whether an incubation of isolated nuclei at the physiological temperature of 37 degrees C induces a redistribution of nuclear components in human K562 erythroleukemia cells. Upon incubation of isolated nuclei for 45 min at 37 degrees C, we have found that two of the antibodies, directed against proteins of the inner matrix network (M(r) 125 and 160 kDa), gave a fluorescent pattern different from that observed in permeabilized cells. By contrast, the fluorescent pattern did not change if nuclei were kept at 0 degrees C. The difference was more marked in case of the 160-kDa polypeptide. The fluorescent pattern detected by the third antibody, which recognizes the 180-kDa nucleolar isoform of DNA topoisomerase II, was unaffected by heat exposure of isolated nuclei. When isolated nuclear matrices prepared from heat-stabilized nuclei were stained by means of the same three antibodies, it was possible to see that the distribution of the 160-kDa matrix protein no longer corresponded to that observable in permeabilized cells, whereas the fluorescent pattern given by the antibody to the 125-kDa polypeptide resembled that detectable in permeabilized cells. The 180-kDa isoform of topoisomerase II was still present in the matrix nucleolar remnants. We conclude that a 37 degrees C incubation of isolated nuclei induces a redistribution of some nuclear matrix antigens and cannot prevent the rearrangement in the spatial organization of one of these antigens that takes place during matrix isolation in human erythroleukemia cells. The practical relevance of these findings is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To investigate the long-term efficacy and safety of denosumab (DMAb) for the treatment of postmenopausal women with osteoporosis in an open-label extension to the 3-year FREEDOM study.1Methods: All women who completed the FREEDOM study were eligible to enter a long-term open-label extension (up to 10 years). After providing informed consent, participants received 6-monthly subcutaneous injections of DMAb (60 mg). Here we report data from the first year of followup. For women randomized to DMAb in the FREEDOM study ('long-term group'), this represents up to 48 months of DMAb exposure (eight 6-monthly injections). For those randomized to placebo ('de novo group') the data are from up to 12 months of exposure (two injections). All participants continued to take calcium (1 g) and vitamin D (≥400 IU) supplements daily. Changes in bone mineral density (BMD) and bone turnover markers (BTM) are reported for subjects enrolled in the extension. No formal statistical testing was planned for this interim report. P-values are descriptive.Results: Overall, 4,550 eligible women (70.2%) who completed the FREEDOM study entered the open-label extension study (long-term, n=2,343; de novo, n=2,207). During the first year of the extension, lumbar spine (LS) BMD in the long-term group further increased by 2.0% (12.1% increase vs. FREEDOM baseline at 48 months), and total hip (TH) BMD further increased by 0.8% (6.5% increase at 48 months) (p<0.0001 for both BMD gains during year 4; Fig. 1). During the first year of the extension, LS and TH BMD increased by 5.4% and 3.0%, respectively in the de novo group (both p<0.0001). After DMAb initiation, serum C-telopeptide (CTX) in the de novo group decreased rapidly and similarly to the long-term group (Fig. 2). Reductions in BTMs continue to attenuate at the end of the dosing interval as previously reported. Adverse event (AE) rates were similar (70.4% of women in the longterm group and 67.9% in the de novo group). Serious Aes were also similar (9.8% and 11.2% of women, respectively). During year 4, osteoporotic nonvertebral fractures were reported in 31 women in the long-term group and 51 in the denovo group.Fig. 1. Percentage change in BMD with denosumab for4 years (long-term) or 1 year (de novo)Fig. 2. Percentage change in sCTX over timeConclusions: These interim results suggest that continuation of DMAb treatment through 48 months is associated with further significant increases in spine and hip BMD with sustained reduction of bone turnover. The de-novo treatment group results confirm the first year active treatment findings previously reported1.Acknowledgements: Amgen Inc. sponsored this study. Figure ©2010, American Society for Bone and Mineral Research, used by permission, all rights reserved. Disclosure of Interest: H. Bone Grant/Research Support from: Amgen, Eli Lilly, Merck, Nordic Bioscience, Novartis, Takeda Pharmaceuticals, Consultant/Speaker's bureau/ Advisory activities with: Amgen, Merck, Takeda Pharmaceuticals, Zelos, S. Papapoulos Consultant/Speaker's bureau/ Advisory activities with: Amgen, Merck, Novartis, Lilly, Procter and Gamble, GSK, M.-L. Brandi Grant/Research Support from: MSD, GSK, Nycomed, NPS, Amgen, J. Brown Grant/Research Support from: Abbott, Amgen, Bristol Myers Squibb, Eli Lilly, Pfizer, Roche, Consultant/ Speaker's bureau/Advisory activities with: Abbott, Amgen, Eli Lilly, Novartis, Merck, Warner Chilcott,, R. Chapurlat Grant/Research Support from: Servier, Sanofi-Aventis, Warner-Chilcott, Novartis, Merck, Consultant/Speaker's bureau/Advisory activities with: Servier, Novartis, Amgen, E. Czerwinski: None Declared, N. Daizadeh Employee of: Amgen Inc., Stock ownership or royalties of: Amgen Inc., A. Grauer Employee of: Amgen Inc., Stock ownership or royalties of: Amgen Inc., C. Haller Employee of: Amgen Inc., Stock ownership or royalties of: Amgen Inc., M.-A. Krieg: None Declared, C. Libanati Employee of: Amgen Inc., Stock ownership or royalties of: Amgen Inc., Z. Man Grant/Research Support from: Amgen, D. Mellström: None Declared, S. Radominski Grant/Research Support from: Amgen, Pfizer, Roche, BMS, J.-Y. Reginster Grant/Research Support from: Bristol Myers Squibb, Merck Sharp & Dohme, Rottapharm, Teva, Lilly, Novartis, Roche, GlaxoSmithKline, Amgen, Servier, Consultant/Speaker's bureau/ Advisory activities with: Servier, Novartis, Negma, Lilly,Wyeth, Amgen, GlaxoSmithKline, Roche, Merckle, Nycomed, NPS, Theramex, UCB, Merck, Sharpe & Dohme, Rottapharm, IBSA, Genvrier, Teijin, Teva, Ebewee Pharma, Zodiac, Analis, Theramex, Novo-Nordisk, H. Resch: None Declared, J. A. Román Grant/Research Support from: Roche, Pharma, C. Roux Grant/Research Support from: Amgen, MSD, Novartis, Servier, Roche, Consultant/ Speaker's bureau/Advisory activities with: Amgen, MSD, Novartis, Servier, Roche, S. Cummings Grant/ Research Support from: Amgen, Lilly, Consultant/Speaker's bureau/Advisory activities with: Amgen, Lilly, Novartis, Merck

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Exposure to solar ultraviolet (UV) radiation is the main causative factor for skin cancer. UV exposure depends on environmental and individual factors, but individual exposure data remain scarce. While ground UV irradiance is monitored via different techniques, it is difficult to translate such observations into human UV exposure or dose because of confounding factors. A multi-disciplinary collaboration developed a model predicting the dose and distribution of UV exposure on the basis of ground irradiation and morphological data. Standard 3D computer graphics techniques were adapted to develop a simulation tool that estimates solar exposure of a virtual manikin depicted as a triangle mesh surface. The amount of solar energy received by various body locations is computed for direct, diffuse and reflected radiation separately. Dosimetric measurements obtained in field conditions were used to assess the model performance. The model predicted exposure to solar UV adequately with a symmetric mean absolute percentage error of 13% and half of the predictions within 17% range of the measurements. Using this tool, solar UV exposure patterns were investigated with respect to the relative contribution of the direct, diffuse and reflected radiation. Exposure doses for various body parts and exposure scenarios of a standing individual were assessed using erythemally-weighted UV ground irradiance data measured in 2009 at Payerne, Switzerland as input. For most anatomical sites, mean daily doses were high (typically 6.2-14.6 Standard Erythemal Dose, SED) and exceeded recommended exposure values. Direct exposure was important during specific periods (e. g. midday during summer), but contributed moderately to the annual dose, ranging from 15 to 24% for vertical and horizontal body parts, respectively. Diffuse irradiation explained about 80% of the cumulative annual exposure dose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: CYP2D6 is the key enzyme responsible for tamoxifen bioactivation mainly into endoxifen. This gene is highly polymorphic and breast cancer patients classified as CYP2D6 poor metabolizers (PM) or intermediate metabolizers (IM) appear to show low concentrations of endoxifen and to achieve less benefit from tamoxifen treatment. Purpose: This prospective, open-label trial aimed to assess how the increase of tamoxifen dose influences the level of endoxifen in the different genotype groups (poor-, intermediate-, and extensive-metabolizers (EM)). We examined the impact of doubling tamoxifen dose to 20mg twice daily on endoxifen plasma concentrations across these genotype groups. Patients and methods: Patients were assayed for CYP2D6 genotype and phenotype using dextromethorphan test. Tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen plasma levels were determined on 2 occasions at baseline (20mg/day of tamoxifen) and at day 30, 90 and 120 after dose increase (20 mg twice daily) using liquid chromatography-tandem-mass spectrometry. Endoxifen plasma levels were measured 6 to 24 hours after last drug intake to evaluate its accumulation before and after doubling tamoxifen dosage. ANOVA was used to evaluate endoxifen levels increase and difference between genotype groups. Results: 63 patients are available for analysis to date. Tamoxifen, N-desmethyltamoxifen, 4-hydroxytamoxifen and endoxifen plasma reached steady state at 30 day after tamoxifen dose escalation, with a significant increase compared to baseline by 1.6 to 1.8 fold : geometric mean plasma concentrations (CV %) were 140 ng/mL (45%) at baseline vs 255 (47%) at day 30 for tamoxifen (P < 0.0001); 256 (49%) vs 408 (64%) for N-desmethyltamoxifen (P < 0.0001); 2.4 (46%) vs 3.9 (51%) for 4-OH-tamoxifen (P < 0.0001); and 20 (91%) vs 33 (91%) for endoxifen (P < 0.02). On baseline, endoxifen levels tended to be lower in PM: 7 ng/mL (36%), than IM: 16 ng/mL (70%), P=0.08, and EM: 24 ng/mL (71%), P<0.001. After doubling tamoxifen dosage, endoxifen concentrations rose similarly in PM, IM and EM with respectively, 1.5 (18%), 1.5 (28%) and 1.7 (30%) fold increase from baseline, P=0.18. Conclusion: Endoxifen exposure varies widely under standard tamoxifen dosage, with CYP2D6 genotype explaining only a minor part of this variability. It increases consistently on doubling tamoxifen dose, similarly across genotypes. This would enable exposure optimization based on concentration monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Manuel O, Pascual M, Perrottet N, Lamoth F, Venetz J-P, Decosterd LA, Buclin T, Meylan PR. Ganciclovir exposure under a 450 mg daily dosage of valganciclovir for cytomegalovirus prevention in kidney transplantation: a prospective study. 
Clin Transplant 2010: 24: 794-800. Abstract:  This prospective study aimed at determining the ganciclovir exposure observed under a daily dosage of 450 mg valganciclovir routinely applied to kidney transplant recipients with a GFR above 25 mL/min at risk for cytomegalovirus (CMV) disease. Ganciclovir levels at trough (C(trough) ) and at peak (C(3 h) ) were measured monthly. Ganciclovir exposure (area under the curve [AUC(0-24) ]) was estimated using Bayesian non-linear mixed-effect modeling (NONMEM). Thirty-six patients received 450 mg of valganciclovir daily for three months. Median ganciclovir C(3 h) was 3.9 mg/L (range: 1.3-7.1), and C(trough) was 0.4 mg/L (range 0.1-2.7). Median AUC(0-24) of ganciclovir was 59.3 mg h/L (39.0-85.3) in patients with GFR(MDRD) 26-39 mL/min, 35.8 mg h/L (24.9-55.8) in patients with GFR(MDRD) 40-59 mL/min, and 29.6 mg h/L (22.0-43.2) in patients with GFR(MDRD)  ≥ 60 mL/min. No major differences in adverse events according to ganciclovir exposure were observed. CMV viremia was not detected during prophylaxis. After discontinuing prophylaxis, CMV viremia was seen in 8/36 patients (22%), and 4/36 patients (11%) developed CMV disease. Ganciclovir exposure after administration of valganciclovir 450 mg daily in recipients with GFR ≥60 mL/min was comparable to those previously reported with oral ganciclovir. A routine daily dose of 450 mg valganciclovir appears to be acceptable for CMV prophylaxis in most kidney transplant recipients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Polychlorinated biphenyls (PCBs) are considered probable human carcinogens by the International Agency for Research on Cancer and one congener, PCB126, has been rated as a known human carcinogen. A period-specific job exposure matrix (JEM) was developed for former PCB-exposed capacitor manufacturing workers (n=12,605) (1938-1977). Methods: A detailed exposure assessment for this plant was based on a number of exposure determinants (proximity, degree of contact with PCBs, temperature, ventilation, process control, job mobility). The intensity and frequency of PCB exposures by job for both inhalation and dermal exposures, and additional chemical exposures were reviewed. The JEM was developed in nine steps: (1) all unique jobs (n=1,684) were assessed using (2) defined PCB exposure determinants; (3) the exposure determinants were used to develop exposure profiles; (4) similar exposure profiles were combined into categories having similar PCB exposures; (5) qualitative intensity (high-medium-low-baseline) and frequency (continuous-intermittent) ratings were developed, and (6) used to qualitatively rate inhalation and dermal exposure separately for each category; (7) quantitative intensity ratings based on available air concentrations were developed for inhalation and dermal exposures based on equal importance of both routes of exposure; (8) adjustments were made for overall exposure, and (9) for each category the product of intensity and frequency was calculated, and exposure in the earlier era was weighted. Results: A period-specific JEM modified for two eras of stable PCB exposure conditions. Conclusions: These exposure estimates, derived from a systematic and rigorous use of the exposure determinant data, lead to cumulative PCB exposure-response relationships in the epidemiological cancer mortality and incidence studies of this cohort. [Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Suite à un accident exposant à du sang (piqûre; coupure), provenant d'un patient infecté, le risque d'infection par VIH est d'environ 0,3% et par le virus de l'hépatite C (VHC) d'environ 0,5%. Chez les personnes vaccinées avec une réponse immunitaire adéquate (titre d'anticorps HBs >100 mUI/ml), aucune infection professionnelle par hépatite B n'a été reconnue en Suisse. La plupart des infections par VIH et VHB peuvent être prévenues par un traitement d'urgence et une prophylaxie postexpositionnelle (PEP). Il n'y a actuellement aucune prophylaxie postexpositionnelle pour le VHC. En cas de transmission de VHC, un traitement rapide par peginterféron et ribavirine est à envisager. Chaque hôpital et cabinet médical doivent mettre sur pied un système pour assurer une prise en charge optimale et en urgence des blessures par piqûres ou coupures. Lors de blessures accidentelles avec du sang de patients séropositifs pour le VIH et dans des situations complexes, il est recommandé de consulter un médecin du personnel ou un infectiologue expérimenté. The risk of infection after an occupational needle stick injury with blood from an infected source patient is approximately 0.3% for HIV and 0.5% for hepatitis C virus (HCV). In Switzerland no cases of occupational HBV infection have been recorded in fully vaccinated persons with a documented adequate vaccine response (HBsantibody titer >100 mIU/mL). Most occupational HIV und HBV infections can be prevented by appropriate emergency measures and post-exposure prophylaxis (PEP). No HCV-PEP is currently available. Early therapy with peginterferon and ribavirin should be considered in cases of occupational HCV seroconversion. Every hospital and office practice should establish a system for 24 h/24 h emergency management of occupational needle stick injuries. In the setting of an HIV-seropositive source patient and in complex situations, early consultation with a specialist in occupational medicine or infectious diseases should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La tomodensitométrie (CT) est une technique d'imagerie dont l'intérêt n'a cessé de croître depuis son apparition dans le début des années 70. Dans le domaine médical, son utilisation est incontournable à tel point que ce système d'imagerie pourrait être amené à devenir victime de son succès si son impact au niveau de l'exposition de la population ne fait pas l'objet d'une attention particulière. Bien évidemment, l'augmentation du nombre d'examens CT a permis d'améliorer la prise en charge des patients ou a rendu certaines procédures moins invasives. Toutefois, pour assurer que le compromis risque - bénéfice soit toujours en faveur du patient, il est nécessaire d'éviter de délivrer des doses non utiles au diagnostic.¦Si cette action est importante chez l'adulte elle doit être une priorité lorsque les examens se font chez l'enfant, en particulier lorsque l'on suit des pathologies qui nécessitent plusieurs examens CT au cours de la vie du patient. En effet, les enfants et jeunes adultes sont plus radiosensibles. De plus, leur espérance de vie étant supérieure à celle de l'adulte, ils présentent un risque accru de développer un cancer radio-induit dont la phase de latence peut être supérieure à vingt ans. Partant du principe que chaque examen radiologique est justifié, il devient dès lors nécessaire d'optimiser les protocoles d'acquisitions pour s'assurer que le patient ne soit pas irradié inutilement. L'avancée technologique au niveau du CT est très rapide et depuis 2009, de nouvelles techniques de reconstructions d'images, dites itératives, ont été introduites afin de réduire la dose et améliorer la qualité d'image.¦Le présent travail a pour objectif de déterminer le potentiel des reconstructions itératives statistiques pour réduire au minimum les doses délivrées lors d'examens CT chez l'enfant et le jeune adulte tout en conservant une qualité d'image permettant le diagnostic, ceci afin de proposer des protocoles optimisés.¦L'optimisation d'un protocole d'examen CT nécessite de pouvoir évaluer la dose délivrée et la qualité d'image utile au diagnostic. Alors que la dose est estimée au moyen d'indices CT (CTDIV0| et DLP), ce travail a la particularité d'utiliser deux approches radicalement différentes pour évaluer la qualité d'image. La première approche dite « physique », se base sur le calcul de métriques physiques (SD, MTF, NPS, etc.) mesurées dans des conditions bien définies, le plus souvent sur fantômes. Bien que cette démarche soit limitée car elle n'intègre pas la perception des radiologues, elle permet de caractériser de manière rapide et simple certaines propriétés d'une image. La seconde approche, dite « clinique », est basée sur l'évaluation de structures anatomiques (critères diagnostiques) présentes sur les images de patients. Des radiologues, impliqués dans l'étape d'évaluation, doivent qualifier la qualité des structures d'un point de vue diagnostique en utilisant une échelle de notation simple. Cette approche, lourde à mettre en place, a l'avantage d'être proche du travail du radiologue et peut être considérée comme méthode de référence.¦Parmi les principaux résultats de ce travail, il a été montré que les algorithmes itératifs statistiques étudiés en clinique (ASIR?, VEO?) ont un important potentiel pour réduire la dose au CT (jusqu'à-90%). Cependant, par leur fonctionnement, ils modifient l'apparence de l'image en entraînant un changement de texture qui pourrait affecter la qualité du diagnostic. En comparant les résultats fournis par les approches « clinique » et « physique », il a été montré que ce changement de texture se traduit par une modification du spectre fréquentiel du bruit dont l'analyse permet d'anticiper ou d'éviter une perte diagnostique. Ce travail montre également que l'intégration de ces nouvelles techniques de reconstruction en clinique ne peut se faire de manière simple sur la base de protocoles utilisant des reconstructions classiques. Les conclusions de ce travail ainsi que les outils développés pourront également guider de futures études dans le domaine de la qualité d'image, comme par exemple, l'analyse de textures ou la modélisation d'observateurs pour le CT.¦-¦Computed tomography (CT) is an imaging technique in which interest has been growing since it first began to be used in the early 1970s. In the clinical environment, this imaging system has emerged as the gold standard modality because of its high sensitivity in producing accurate diagnostic images. However, even if a direct benefit to patient healthcare is attributed to CT, the dramatic increase of the number of CT examinations performed has raised concerns about the potential negative effects of ionizing radiation on the population. To insure a benefit - risk that works in favor of a patient, it is important to balance image quality and dose in order to avoid unnecessary patient exposure.¦If this balance is important for adults, it should be an absolute priority for children undergoing CT examinations, especially for patients suffering from diseases requiring several follow-up examinations over the patient's lifetime. Indeed, children and young adults are more sensitive to ionizing radiation and have an extended life span in comparison to adults. For this population, the risk of developing cancer, whose latency period exceeds 20 years, is significantly higher than for adults. Assuming that each patient examination is justified, it then becomes a priority to optimize CT acquisition protocols in order to minimize the delivered dose to the patient. Over the past few years, CT advances have been developing at a rapid pace. Since 2009, new iterative image reconstruction techniques, called statistical iterative reconstructions, have been introduced in order to decrease patient exposure and improve image quality.¦The goal of the present work was to determine the potential of statistical iterative reconstructions to reduce dose as much as possible without compromising image quality and maintain diagnosis of children and young adult examinations.¦The optimization step requires the evaluation of the delivered dose and image quality useful to perform diagnosis. While the dose is estimated using CT indices (CTDIV0| and DLP), the particularity of this research was to use two radically different approaches to evaluate image quality. The first approach, called the "physical approach", computed physical metrics (SD, MTF, NPS, etc.) measured on phantoms in well-known conditions. Although this technique has some limitations because it does not take radiologist perspective into account, it enables the physical characterization of image properties in a simple and timely way. The second approach, called the "clinical approach", was based on the evaluation of anatomical structures (diagnostic criteria) present on patient images. Radiologists, involved in the assessment step, were asked to score image quality of structures for diagnostic purposes using a simple rating scale. This approach is relatively complicated to implement and also time-consuming. Nevertheless, it has the advantage of being very close to the practice of radiologists and is considered as a reference method.¦Primarily, this work revealed that the statistical iterative reconstructions studied in clinic (ASIR? and VECO have a strong potential to reduce CT dose (up to -90%). However, by their mechanisms, they lead to a modification of the image appearance with a change in image texture which may then effect the quality of the diagnosis. By comparing the results of the "clinical" and "physical" approach, it was showed that a change in texture is related to a modification of the noise spectrum bandwidth. The NPS analysis makes possible to anticipate or avoid a decrease in image quality. This project demonstrated that integrating these new statistical iterative reconstruction techniques can be complex and cannot be made on the basis of protocols using conventional reconstructions. The conclusions of this work and the image quality tools developed will be able to guide future studies in the field of image quality as texture analysis or model observers dedicated to CT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Excessive exposure to solar Ultra-Violet (UV) light is the main cause of most skin cancers in humans. Factors such as the increase of solar irradiation at ground level (anthropic pollution), the rise in standard of living (vacation in sunny areas), and (mostly) the development of outdoor activities have contributed to increase exposure. Thus, unsurprisingly, incidence of skin cancers has increased over the last decades more than that of any other cancer. Melanoma is the most lethal cutaneous cancer, while cutaneous carcinomas are the most common cancer type worldwide. UV exposure depends on environmental as well as individual factors related to activity. The influence of individual factors on exposure among building workers was investigated in a previous study. Posture and orientation were found to account for at least 38% of the total variance of relative individual exposure. A high variance of short-term exposure was observed between different body locations, indicating the occurrence of intense, subacute exposures. It was also found that effective short-term exposure ranged between 0 and 200% of ambient irradiation, suggesting that ambient irradiation is a poor predictor of effective exposure. Various dosimetric techniques enable to assess individual effective exposure, but dosimetric measurements remain tedious and tend to be situation-specific. As a matter of facts, individual factors (exposure time, body posture and orientation in the sun) often limit the extrapolation of exposure results to similar activities conducted in other conditions. Objective: The research presented in this paper aims at developing and validating a predictive tool of effective individual exposure to solar UV. Methods: Existing computer graphic techniques (3D rendering) were adapted to reflect solar exposure conditions and calculate short-term anatomical doses. A numerical model, represented as a 3D triangular mesh, is used to represent the exposed body. The amount of solar energy received by each "triangle is calculated, taking into account irradiation intensity, incidence angle and possible shadowing from other body parts. The model take into account the three components of the solar irradiation (direct, diffuse and albedo) as well as the orientation and posture of the body. Field measurements were carried out using a forensic mannequin at the Payerne MeteoSwiss station. Short-term dosimetric measurements were performed in 7 anatomical locations for 5 body postures. Field results were compared to the model prediction obtained from the numerical model. Results: The best match between prediction and measurements was obtained for upper body parts such as shoulders (Ratio Modelled/Measured; Mean = 1.21, SD = 0.34) and neck (Mean = 0.81, SD = 0.32). Small curved body parts such as forehead (Mean = 6.48, SD = 9.61) exhibited a lower matching. The prediction is less accurate for complex postures such as kneeling (Mean = 4.13, SD = 8.38) compared to standing up (Mean = 0.85, SD = 0.48). The values obtained from the dosimeters and the ones computed from the model are globally consistent. Conclusion: Although further development and validation are required, these results suggest that effective exposure could be predicted for a given activity (work or leisure) in various ambient irradiation conditions. Using a generic modelling approach is of high interest in terms of implementation costs as well as predictive and retrospective capabilities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Epidemiological studies have demonstrated that exposure to fine particles is associated to adverse health effects, including cancer, respiratory and cardiovascular diseases. However, mechanisms by which particles induce health effects remain unclear. According to one of the most investigated hypotheses, particles cause adverse effects through the production of reactive oxygen species (ROS), which are very hazardous compounds able to attack directly biological structures, including the DNA strand or the lipid bilayer of the cells. If the defense mechanisms, constituted of antioxidants, are not able to counter ROS, then these compounds will cause in the body a range of oxidation reactions called "oxidative stress". The aim of the present research project was to better understand mechanisms by which exposure to fine particles induces oxidative stress. The first point of this project was to check whether exposure to high levels of fine particles is directly linked to oxidative stress, and whether this oxidative stress is accompanied by the activation of the defense mechanisms (antioxidants). The second point was to study the role played by the particle surface characteristics in the oxidative stress process. For that purpose, a study was conducted in bus depots with the participation of 40 mechanics. First, occupational exposure to particles (PM4) and to other pollutants (NOx, O3) was measured over a two-day period. Then, urine samples of mechanics were collected in order to measure levels of 8-hydroxy-2'-deoxyguanosine (8OHdG) and antioxidants. 8OHdG is a molecule formed by the oxidation of DNA and allowing to assess the oxidative stress status of the mechanics. Finally, particles were collected on filters, and functional groups located on the particle surface were analyzed in the laboratory using a Knudsen flow reactor. This technique allows not only to quantify functional groups on the particle surface, but also to measure the reaction kinetics. Results obtained during the field campaign in bus depots showed that mechanics were exposed to rather low levels of PM4 (20-85 μg/m3) and of pollutants (NOx: 100-1000 ppb; O3: <15 ppb). However, despite this low exposure, urinary levels of the oxidative stress biomarker (8OHdG) increased significantly for non-smoking workers over a two-day period of shift. This oxidative stress was accompanied by an increase of antioxidants, indicating the activation of defense mechanisms. On the other hand, the analysis of functional groups on the particle surface showed important differences, depending on the workplace, the date and the activities of workers. The particle surface contained simultaneously antagonistic functional groups which did not undergo internal reactions (such as acids and bases), and was usually characterized by a high density of carbonyl functions and a low density of acidic sites. Reaction kinetics measured using the Knudsen flow reactor pointed out fast reactions of oxidizable groups and slow reactions of acidic sites. Several exposure parameters were significantly correlated with the increase of the oxidative stress status: the presence of acidic sites, carbonyl functions and oxidizable groups on the particle surface; reaction kinetics of functional groups on the particle surface; particulate iron and copper concentrations; and NOx concentration.