885 resultados para Medication errors
Resumo:
PURPOSE The range of patient setup errors in six dimensions detected in clinical routine for cranial as well as for extracranial treatments, were analyzed while performing linear accelerator based stereotactic treatments with frameless patient setup systems. Additionally, the need for re-verification of the patient setup for situations where couch rotations are involved was analyzed for patients treated in the cranial region. METHODS AND MATERIALS A total of 2185 initial (i.e. after pre-positioning the patient with the infrared system but before image guidance) patient setup errors (1705 in the cranial and 480 in the extracranial region) obtained by using ExacTrac (BrainLAB AG, Feldkirchen, Germany) were analyzed. Additionally, the patient setup errors as a function of the couch rotation angle were obtained by analyzing 242 setup errors in the cranial region. Before the couch was rotated, the patient setup error was corrected at couch rotation angle 0° with the aid of image guidance and the six degrees of freedom (6DoF) couch. For both situations attainment rates for two different tolerances (tolerance A: ± 0.5mm, ± 0.5°; tolerance B: ± 1.0 mm, ± 1.0°) were calculated. RESULTS The mean (± one standard deviation) initial patient setup errors for the cranial cases were -0.24 ± 1.21°, -0.23 ± 0.91° and -0.03 ± 1.07° for the pitch, roll and couch rotation axes and 0.10 ± 1.17 mm, 0.10 ± 1.62 mm and 0.11 ± 1.29 mm for the lateral, longitudinal and vertical axes, respectively. Attainment rate (all six axes simultaneously) for tolerance A was 0.6% and 13.1% for tolerance B, respectively. For the extracranial cases the corresponding values were -0.21 ± 0.95°, -0.05 ± 1.08° and -0.14 ± 1.02° for the pitch, roll and couch rotation axes and 0.15 ± 1.77 mm, 0.62 ± 1.94 mm and -0.40 ± 2.15 mm for the lateral, longitudinal and vertical axes. Attainment rate (all six axes simultaneously) for tolerance A was 0.0% and 3.1% for tolerance B, respectively. After initial setup correction and rotation of the couch to treatment position a re-correction has to be performed in 77.4% of all cases to fulfill tolerance A and in 15.6% of all cases to fulfill tolerance B. CONCLUSION The analysis of the data shows that all six axes of a 6DoF couch are used extensively for patient setup in clinical routine. In order to fulfill high patient setup accuracies (e.g. for stereotactic treatments), a 6DoF couch is recommended. Moreover, re-verification of the patient setup after rotating the couch is required in clinical routine.
Resumo:
BACKGROUND Data on pharmacological management during pregnancy are scarce. The aim of this study was to describe the type and frequency of cardiac medication used in pregnancy in patients with cardiovascular disease and to assess the relationship between medication use and fetal outcome. METHODS AND RESULTS Between 2007 and 2011 sixty hospitals in 28 countries enrolled 1321 pregnant women. All patients had structural heart disease (congenital 66%, valvular 25% or cardiomyopathy 7% or ischemic 2%). Medication was used by 424 patients (32%) at some time during pregnancy: 22% used beta-blockers, 8% antiplatelet agents, 7% diuretics, 2.8% ACE inhibitors and 0.5% statins. Compared to those who did not take medication, patients taking medication were older, more likely to be parous, have valvular heart disease and were less often in sinus rhythm. The odds ratio of fetal adverse events in users versus non-users of medication was 2.6 (95% CI 2.0-3.4) and after adjustment for cardiac and obstetric parameter was 2.0 (95% CI 1.4-2.7). Babies of patients treated with beta-blockers had a significantly lower adjusted birth weight (3140 versus 3240 g, p = 0.002). The highest rate of fetal malformation was found in patients taking ACE inhibitors (8%). CONCLUSION One third of pregnant women with heart disease used cardiac medication during their pregnancy, which was associated with an increased rate of adverse fetal events. Birth weight was significantly lower in children of patients taking beta-blockers. A randomized trial is needed to distinguish the effects of the medication from the effects of the underlying maternal cardiac condition.
Resumo:
Studies of memory-guided saccades in monkeys show an upward bias, while studies of antisaccades in humans show a diagonal effect, a deviation of endpoints toward the 45° diagonal. To determine if these two different spatial biases are specific to different types of saccades, we studied prosaccades, antisaccades and memory-guided saccades in humans. The diagonal effect occurred not with prosaccades but with antisaccades and memory-guided saccades with long intervals, consistent with hypotheses that it originates in computations of goal location under conditions of uncertainty. There was a small upward bias for memory-guided saccades but not prosaccades or antisaccades. Thus this bias is not a general effect of target uncertainty but a property specific to memory-guided saccades.
Resumo:
BACKGROUND Clinicians involved in medical errors can experience significant distress. This study aims to examine (1) how medical errors impact anaesthesiologists in key work and life domains; (2) anaesthesiologists' attitudes regarding support after errors; (3) and which anaesthesiologists are most affected by errors. METHODS This study is a mailed cross-sectional survey completed by 281 of the 542 clinically active anaesthesiologists (52% response rate) working at Switzerland's five university hospitals between July 2012 and April 2013. RESULTS Respondents reported that errors had negatively affected anxiety about future errors (51%), confidence in their ability as a doctor (45%), ability to sleep (36%), job satisfaction (32%), and professional reputation (9%). Respondents' lives were more likely to be affected as error severity increased. Ninety per cent of respondents disagreed that hospitals adequately support them in coping with the stress associated with medical errors. Nearly all of the respondents (92%) reported being interested in psychological counselling after a serious error, but many identified barriers to seeking counselling. However, there were significant differences between departments regarding error-related stress levels and attitudes about error-related support. Respondents were more likely to experience certain distress if they were female, older, had previously been involved in a serious error, and were dissatisfied with their last error disclosure. CONCLUSION Medical errors, even minor errors and near misses, can have a serious effect on clinicians. Health-care organisations need to do more to support clinicians in coping with the stress associated with medical errors.
Resumo:
BACKGROUND There is limited research on anaesthesiologists' attitudes and experiences regarding medical error communication, particularly concerning disclosing errors to patients. OBJECTIVE To characterise anaesthesiologists' attitudes and experiences regarding disclosing errors to patients and reporting errors within the hospital, and to examine factors influencing their willingness to disclose or report errors. DESIGN Cross-sectional survey. SETTING Switzerland's five university hospitals' departments of anaesthesia in 2012/2013. PARTICIPANTS Two hundred and eighty-one clinically active anaesthesiologists. MAIN OUTCOME MEASURES Anaesthesiologists' attitudes and experiences regarding medical error communication. RESULTS The overall response rate of the survey was 52% (281/542). Respondents broadly endorsed disclosing harmful errors to patients (100% serious, 77% minor errors, 19% near misses), but also reported factors that might make them less likely to actually disclose such errors. Only 12% of respondents had previously received training on how to disclose errors to patients, although 93% were interested in receiving training. Overall, 97% of respondents agreed that serious errors should be reported, but willingness to report minor errors (74%) and near misses (59%) was lower. Respondents were more likely to strongly agree that serious errors should be reported if they also thought that their hospital would implement systematic changes after errors were reported [(odds ratio, 2.097 (95% confidence interval, 1.16 to 3.81)]. Significant differences in attitudes between departments regarding error disclosure and reporting were noted. CONCLUSION Willingness to disclose or report errors varied widely between hospitals. Thus, heads of department and hospital chiefs need to be aware of the importance of local culture when it comes to error communication. Error disclosure training and improving feedback on how error reports are being used to improve patient safety may also be important steps in increasing anaesthesiologists' communication of errors.
Resumo:
Charcoal particles in pollen slides are often abundant, and thus analysts are faced with the problem of setting the minimum counting sum as small as possible in order to save time. We analysed the reliability of charcoal-concentration estimates based on different counting sums, using simulated low-to high-count samples. Bootstrap simulations indicate that the variability of inferred charcoal concentrations increases progressively with decreasing sums. Below 200 items (i.e., the sum of charcoal particles and exotic marker grains), reconstructed fire incidence is either too high or too low. Statistical comparisons show that the means of bootstrap simulations stabilize after 200 counts. Moreover, a count of 200-300 items is sufficient to produce a charcoal-concentration estimate with less than+5% error if compared with high-count samples of 1000 items for charcoal/marker grain ratios 0.1-0.91. If, however, this ratio is extremely high or low (> 0.91 or < 0.1) and if such samples are frequent, we suggest that marker grains are reduced or added prior to new sample processing.
Resumo:
BACKGROUND: Stimulants, such as methylphenidate, are among the most commonly used medications in children and adolescents. Psychotic symptoms have been reported as rare adverse reactions to stimulants but have not been systematically inquired about in most previous studies. Family history of mental illness may increase the vulnerability to drug-induced psychotic symptoms. We examined the association between stimulant use and psychotic symptoms in sons and daughters of parents with major mood and psychotic disorders. METHODS: We assessed psychotic symptoms, psychotic-like experiences, and basic symptoms in 141 children and youth (mean ± SD age: 11.8 ± 4.0 years; range: 6–21 years), who had 1 or both parents with major depressive disorder, bipolar disorder, or schizophrenia, and of whom 24 (17.0%) had taken stimulant medication. RESULTS: Psychotic symptoms were present in 62.5% of youth who had taken stimulants compared with 27.4% of participants who had never taken stimulants. The association between stimulant use and psychotic experiences remained significant after adjustment for potential confounders (odds ratio: 4.41; 95% confidence interval: 1.82–10.69; P = .001) and was driven by hallucinations occurring during the use of stimulant medication. A temporal relationship between use of stimulants and psychotic symptoms was supported by an association between current stimulant use and current psychotic symptoms and co-occurrence in cases that were assessed on and off stimulants. CONCLUSIONS: Psychotic symptoms should be monitored during the use of stimulants in children and adolescents. Family history of mood and psychotic disorders may need to be taken into account when considering the prescription of stimulants.
Resumo:
BACKGROUND: Several parameters of heart rate variability (HRV) have been shown to predict the risk of sudden cardiac death (SCD) in cardiac patients. There is consensus that risk prediction is increased when measuring HRV during specific provocations such as orthostatic challenge. For the first time, we provide data on reproducibility of such a test in patients with a history of acute coronary syndrome. METHODS: Sixty male patients (65+/-8years) with a history of acute coronary syndrome on stable medication were included. HRV was measured in supine (5min) and standing (5min) position on 2 occasions separated by two weeks. For risk assessment relevant time-domain [standard deviation of all R-R intervals (SDNN) and root mean squared standard differences between adjacent R-R intervals (RMSSD)], frequency domain [low-frequency power (LF), high-frequency power (HF) and LF/HF power ratio] and short-term fractal scaling component (DF1) were computed. Absolute reproducibility was assessed with the standard errors of the mean (SEM) and 95% limits of random variation, and relative reproducibility by the intraclass correlation coefficient (ICC). RESULTS: We found comparable SEMs and ICCs in supine position and after an orthostatic challenge test. All ICCs were good to excellent (ICCs between 0.636 and 0.869). CONCLUSIONS: Reproducibility of HRV parameters during orthostatic challenge is good and comparable with supine position.
Resumo:
Studies have shown that the discriminability of successive time intervals depends on the presentation order of the standard (St) and the comparison (Co) stimuli. Also, this order affects the point of subjective equality. The first effect is here called the standard-position effect (SPE); the latter is known as the time-order error. In the present study, we investigated how these two effects vary across interval types and standard durations, using Hellström’s sensation-weighting model to describe the results and relate them to stimulus comparison mechanisms. In Experiment 1, four modes of interval presentation were used, factorially combining interval type (filled, empty) and sensory modality (auditory, visual). For each mode, two presentation orders (St–Co, Co–St) and two standard durations (100 ms, 1,000 ms) were used; half of the participants received correctness feedback, and half of them did not. The interstimulus interval was 900 ms. The SPEs were negative (i.e., a smaller difference limen for St–Co than for Co–St), except for the filled-auditory and empty-visual 100-ms standards, for which a positive effect was obtained. In Experiment 2, duration discrimination was investigated for filled auditory intervals with four standards between 100 and 1,000 ms, an interstimulus interval of 900 ms, and no feedback. Standard duration interacted with presentation order, here yielding SPEs that were negative for standards of 100 and 1,000 ms, but positive for 215 and 464 ms. Our findings indicate that the SPE can be positive as well as negative, depending on the interval type and standard duration, reflecting the relative weighting of the stimulus information, as is described by the sensation-weighting model.
Resumo:
The so-called Dutch Pranketing Room of Alethea Talbot, Countess of Arundel, at Tart Hall was a site of domestic experiments, courtly splendour and global ambition. Lady Arundel, the probable author of a famous recipe book, would have used Tart Hall for cooking and experiments as well as for impressive dinner parties, and she would have used large amounts of sugar to create intricate imitations of meat and vegetables to astonish, entertain and delight her guests. Linking household practice with global trade as well as artistic creation, Lady Arundel’s banquets are situated not only between a national tradition of cooking, as it appears in Markham’s manuals, and the new possibilities the arising global trade provided, but also played with a mismatch between taste and sight. This mediating role could be compared to that played by the artists the Countess employed. Within this context it is worth noting that a series of paintings displayed in the building’s gallery showed still lifes, markets, and a cook. The inventory of Tart Hall gives an insight into the world of the widely travelled collector and patron of Van Dyck and Rubens, but raises also a number of questions. In my talk I would like to explore the Countess’ Pranketing Room as a site of mediation between alimentary and painterly experiments, considering the use of recipes, experience, invention and transformation
Resumo:
Sentinel-5 (S5) and its precursor (S5P) are future European satellite missions aiming at global monitoring of methane (CH4) column-average dry air mole fractions (XCH4). The spectrometers to be deployed onboard the satellites record spectra of sunlight backscattered from the Earth's surface and atmosphere. In particular, they exploit CH4 absorption in the shortwave infrared spectral range around 1.65 mu m (S5 only) and 2.35 mu m (both S5 and S5P) wavelength. Given an accuracy goal of better than 2% for XCH4 to be delivered on regional scales, assessment and reduction of potential sources of systematic error such as spectroscopic uncertainties is crucial. Here, we investigate how spectroscopic errors propagate into retrieval errors on the global scale. To this end, absorption spectra of a ground-based Fourier transform spectrometer (FTS) operating at very high spectral resolution serve as estimate for the quality of the spectroscopic parameters. Feeding the FTS fitting residuals as a perturbation into a global ensemble of simulated S5- and S5P-like spectra at relatively low spectral resolution, XCH4 retrieval errors exceed 0.6% in large parts of the world and show systematic correlations on regional scales, calling for improved spectroscopic parameters.
Resumo:
Height of instrument (HI) blunders in GPS measurements cause position errors. These errors can be pure vertical, pure horizontal, or a mixture of both. There are different error regimes depending on whether both the base and the rover both have HI blunders, if just the base has an HI blunder, or just the rover has an HI blunder. The resulting errors are on the order of 30 cm for receiver separations of 1000 km for an HI blunder of 2 m. Given the complicated nature of the errors, we believe it would be difficult, if not impossible, to detect such errors by visual inspection. This serves to underline the necessity to enter GPS HI's correctly.
Resumo:
Height of instrument (HI) blunders in GPS measurements cause position errors. These errors can be pure vertical, pure horizontal, or a mixture of both. There are different error regimes depending on whether both the base and the rover both have HI blunders, if just the base has an HI blunder, or just the rover has an HI blunder. The resulting errors are on the order of 30 cm for receiver separations of 1000 km for an HI blunder of 2 m. Given the complicated nature of the errors, we believe it would be difficult, if not impossible, to detect such errors by visual inspection. This serves to underline the necessity to enter GPS HIs correctly.