952 resultados para M2-m3 Loop
Resumo:
The objective of this work is to develop a non-stoichiometric equilibrium model to study parameter effects in the gasification process of a feedstock in downdraft gasifiers. The non-stoichiometric equilibrium model is also known as the Gibbs free energy minimization method. Four models were developed and tested. First a pure non-stoichiometric equilibrium model called M1 was developed; then the methane content was constrained by correlating experimental data and generating the model M2. A kinetic constraint that determines the apparent gasification rate was considered for model M3 and finally the two aforementioned constraints were implemented together in model M4. Models M2 and M4 showed to be the more accurate among the four developed models with mean RMS (root mean square error) values of 1.25 each.Also the gasification of Brazilian Pinus elliottii in a downdraft gasifier with air as gasification agent was studied. The input parameters considered were: (a) equivalence ratio (0.28-035); (b) moisture content (5-20%); (c) gasification time (30-120 min) and carbon conversion efficiency (80-100%). (C) 2014 Elsevier Ltd. All rights reserved.
Resumo:
The aim of this work is to develop stoichiometric equilibrium models that permit the study of parameters effect in the gasification process of a particular feedstock. In total four models were tested in order to determine the syngas composition. One of these four models, called M2, was based on the theoretical equilibrium constants modified by two correction factors determined using published experimental data. The other two models, M3 and M4 were based in correlations, while model M4 was based in correlations to determine the equilibrium constants, model M3 was based in correlations that relate the H-2, CO and CO2 content on the synthesis gas. Model M2 proved to be the more accurate and versatile among these four models, and also showed better results than some previously published models. Also a case study for the gasification of a blend of hardwood chips and glycerol at 80% and 20% respectively, was performed considering equivalence ratios form 0.3 to 0.5, moisture contents from 0%-20% and oxygen percentages in the gasification agent of 100%, 60% and 21%. (C) 2013 Elsevier Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Different mathematical methods have been applied to obtain the analytic result for the massless triangle Feynman diagram yielding a sum of four linearly independent (LI) hypergeometric functions of two variables F-4. This result is not physically acceptable when it is embedded in higher loops, because all four hypergeometric functions in the triangle result have the same region of convergence and further integration means going outside those regions of convergence. We could go outside those regions by using the well-known analytic continuation formulas obeyed by the F-4, but there are at least two ways we can do this. Which is the correct one? Whichever continuation one uses, it reduces a number of F-4 from four to three. This reduction in the number of hypergeometric functions can be understood by taking into account the fundamental physical constraint imposed by the conservation of momenta flowing along the three legs of the diagram. With this, the number of overall LI functions that enter the most general solution must reduce accordingly. It remains to determine which set of three LI solutions needs to be taken. To determine the exact structure and content of the analytic solution for the three-point function that can be embedded in higher loops, we use the analogy that exists between Feynman diagrams and electric circuit networks, in which the electric current flowing in the network plays the role of the momentum flowing in the lines of a Feynman diagram. This analogy is employed to define exactly which three out of the four hypergeometric functions are relevant to the analytic solution for the Feynman diagram. The analogy is built based on the equivalence between electric resistance circuit networks of types Y and Delta in which flows a conserved current. The equivalence is established via the theorem of minimum energy dissipation within circuits having these structures.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aims of this study was evaluated the efficiency of nitrogen sufficiency index (NSI) calculated with base on the measures relative chlorophyll index (RCI) leaves, measured with portable chlorophyll meter, as an indicator of time of sidedressing N fertilization and verify which value of NSI (90% and 95%) is the most appropriate to indicate the moment of N fertilization on common bean cultivar IAC Alvorada. An experiment with five N managements (M1: 200 kg ha(-1) N (40 kg at sowing + 80 kg at 15 days after emergency (DAE) + 80 kg 30 DAE); M2: 100 kg ha(-1) N (20 kg at sowing + 40 kg at 15 DAE + 40 kg at 30 DAE); M3: 20 kg ha(-1) N at sowing + 30 kg ha(-1) when chlorophyll meter readings indicated NSI < 95%; M4: 20 kg ha(-1) N at sowing + 30 kg N ha(-1) N when chlorophyll meter readings indicated NSI <90% and, M5: control (without N application)) and four replications was carried out in the rainy and dry growing seasons of the agricultural year 2009/10, in Botucatu, Sao Paulo State, Brazil. The variables RCI, aboveground dry matter, leaf N concentration, yield components, grain yield, and N use efficiency were evaluated. The NSI of 90%, calculated based on monitoring of RCI in common bean leaves with chlorophyll meter, was more effective than 95% to define need for N sidedressing in common bean cultivar IAC Alvorada, reducing the N application and improving the use efficiency of applied N.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Contents The objective of this work was to verify that mothers classified as super precocious (M1) and precocious (M2) produce more precocious bulls than females classified as normal (M3). This study included 21186 animals with an average age of 21.29 +/- 1.77months that underwent a breeding soundness evaluation from 1999 to 2008. Of these animals, 2019, 6059 and 13108 were offspring of M1, M2 and M3 females, respectively. In the breeding soundness examination, the animals were classified as sound for reproduction, sound under a natural mating regime, unsound for reproduction and discarded. To compare the averages obtained for each category of mother within the individual breeding soundness classes, a chi-square test with a 5% error probability was used, considering the effects of year and month of birth and farm. For the three classes of mothers (M1, M2 and M3), 67.26, 67.22 and 64.16% of bull calves were considered sound for reproduction and 19.71, 19.46 and 21.90% were considered unsound for reproduction, respectively. There was no difference in the frequency of animals that were sound for reproduction under the natural breeding regime between the three classes of mothers (8.87, 9.31 and 9.19%, respectively). There was a difference between the numbers of precocious and normal females that were discarded, with frequencies of 4.01 and 4.75%, respectively (p<0.05). There were differences in year and month of birth and farm between super precocious and precocious cows in relation to the breeding soundness classification of the animals. It was concluded that the bull offspring of super precocious and precocious cows presented a higher percentage of approval in the breeding soundness examination than the bull offspring of normal cows, demonstrating that the selection for precocity of females has contributed to an increase in the sexual precocity of the herd in relation to the sexual maturity of bulls.
Resumo:
A hipertensão arterial atinge uma média de 20% a 25% da população brasileira. Estudos apontam que a prática regular de atividade física além de combater o sedentarismo pode ser utilizada como meio não farmacológico de tratamento e prevenção da hipertensão. Objetivo: Verificar os efeitos do estado de ânimo gerado por exercícios não sistematizados e sistematizados na pressão arterial. Metodologia: Participaram do estudo 30 alunas que participam há mais de seis meses do Programa Saúde Ativa Rio Claro. Elas receberam treinamento duas semanas, para utilizarem o aparelho de pressão digital de pulso Fuzzy LOGIC. As participantes foram submetidas a 3 sessões de aulas (aeróbio, lúdico e força) em dias diferentes. As aulas do aeróbio contavam com 40 min de caminhada moderada, a aula de força constou 3 séries de 1 minuto, com intervalo entre as séries de 30 segundos para membros superiores e inferiores e a aula lúdica com brincadeiras não padronizadas. As aulas foram constituídas de alongamento (10 min), parte principal (40 min) e volta à calma (10 min). A pressão arterial sistólica (PAS) e diastólica (PAD) foram aferidas nos momentos: repouso (M1), término (M2), 30 minutos após a sessão (M3), 4 horas após (M4) e 8 horas após a sessão dos exercícios (M5). A análise estatística utilizada foi a Anova para medidas repetidas com 2 fatores (Momentos e Tipo de aula) com significância de p<0.05. Resultados: A PAS no M3 foi menor do que no M1 e M2 para todos os protocolos (p<0.05); para a PAD o M3 apresentou valores menores do que o M1 e M2 para todos os protocolos. Conclusão: O efeito hipotensor teve resultados mais significativos quando relacionado a prática dos exercícios do que aos estados de ânimo gerados pelos mesmos. A prática da atividade física foi capaz de alterar positivamente os estados de ânimo dos indivíduos... (Resumo completo, clicar acesso eletrônico abaixo)
Resumo:
A hipertensão arterial (HA) é fator de risco para o desenvolvimento de doenças cardiovasculares, uma forma de prevenção seria a adoção de um estilo de vida mais ativo.O estudo tem como objetivo verificar se uma sessão de exercícios resistidos e aeróbios provoca efeito hipotensivo em indivíduos normotensos e hipertensos sendo a P.A aferida antes e depois dos exercícios. Participaram do estudo 29 indivíduos, normo e hipertensos, com idade média de 54,96 anos ( ± 9,56 ), todos participantes do projeto de atividade física para diabéticos e hipertensos, desenvolvido pelo NAFES da UNESP – Rio Claro. A aula constituiu-se de aquecimento e alongamento (10 min), parte principal (40 min) dividida por: Caminhada (10 min), exercícios resistidos de membro superior utilizando halteres de um quilo (10 min), caminhada (10 min) e exercícios resistidos de membros inferiores com peso corporal (10 min), finalizando com volta calma(10 min). A Pressão Arterial foi aferida através de aparelho digital de pulso Fuzzy LOGIC, Model 3001, BioLand em repouso(M1), ao termino(M2), 30 minutos pós-exercícios(M3) e 4 horas após o termino dos exercícios(M4). Os dados foram analisados por meio do ANOVA para análises repetidas, através do programa Statistic 7.0 e significância de p<0,05. A analise estatística mostrou que na pressão sistólica não houve diferença significante do M1(137,6 ±17,1mmHg) para o M3(133,9 ±18,8mmHg) enquanto que na pressão diastólica observou-se diferença significativa do M1(84,7 ±9,3mmHg) para o M4(80,7 ±11.2mmHg). Conclusão: Houve efeito hipotensor após exercícios apenas na pressão diastólica, já na pressão sistólica não ocorreu mudança significativa embora todos os valores pós exercícios tenham diminuído, tanot na sistólica quanto na diastólica.
Resumo:
Pós-graduação em Cirurgia Veterinária - FCAV
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)