955 resultados para Liquid-chromatographic Determination
Resumo:
The synthetic guanylhydrazones WE010 (3,5-di-tert-butil-4-hidroxibenzaldehyde-guanylhydrazone), WE014 (4-bifenilcarboxialdehydeguanylhydrazone) and WE017 (3,4-diclorobenzaldehydeguanylhydrazone) showed high cytotoxic activity in terms of percentage inhibition of cancer cells growth. However, further progress in the development of these drug candidates requires precise and convenient methods for their qualitative and quantitative analyses. The aim of this study was to develop and validate High Performance Liquid Chromatography with diode-array detection (HPLC-DAD) and Ultra Fast Liquid Chromatography with diode-array detection (UFLC-DAD) methods suitable for as simultaneous as isolated determination of studied guanylhydrazones, based on the optimization of chromatographic parameters and obtaining reduced detection times. The chromatographic analyses of analytes by HPLC were performed on C18 ACE analytical column (150 mm x 4.6 mm), with a particle size of 5.0 μm. Among all the conditions assayed, the best results of separation were obtained with a mixture of methanol:water (60:40, v/v) as the mobile phase at a flow rate 1.5mL/min and pH of 3.5 adjusted at acetic acid. The UFLC method was developed by experimetal desing techniques in order to find optimal chromatographic analytical conditions, which were achieved on XR-ODS analytical column (50 mm x 3.0 mm), with a particle size of 2,2 μm, maintained at 25 ºC. The mobile phase was consisted of methanol:water (65:35, v/v) with 0.1% triethylamine (TEA) and pH of 3.5 adjusted at acetic acid, at a flow rate 0.5 mL/min. The procedure were validated following evaluating parameters such as specificity, linearity, limits of detection (LD) and quantification (LQ), precision, accuracy and robustness, giving results within the acceptable range. Although the UFLC method shows better sensitivity (lower values of LD and LQ), robustness (lower rates of relative standard deviation) and minimize spending time and solvent, both developed methods were adequately applied to the analysis of guanylhydrazones molecules, may be used in routine of quality control laboratories. Keywords: guanylhydrazones, HPLC/DAD, UFLC/DAD, validation of analitical method
Resumo:
Cocaine is one of the most widespread illegal stimulants utilized by the human population throughout the world. The aim of this study was to establish the highest no-effect dose (HNED) of cocaine on the spontaneous locomotor activity (SLA) of horses in a behavior chamber, and thereby to determine the maximal acceptable threshold of the urinary drug concentration in horses. Twelve English thoroughbred mares received 0.02, 0.03, 0.04, 0.08 or 0.12 mg kg(-1) cocaine i.v. or saline solution (control). It was noted that doses above 0.04 mg kg(-1) induced a significant increase in SLA (P < 0.05, Tukey's test). No significant increase in SLA was seen in the mares that received 0.03 mg kg(-1), but the animals showed important behavioral changes that did not occur after the 0.02 mg kg(-1) dose. It was concluded that the HNED of cocaine for horses in a behavior chamber is 0.02 mg kg(-1). After injection of this dose in five horses, urine samples were collected at predetermined intervals through vesical catheterization. The concentrations of cocaine, norcocaine, benzoylecgonine and ecgonine methyl ester were quantified by liquid chromatography/electrospray ionization tandem mass spectrometry. Cocaine and norcocaine concentrations remained consistently below the level of detection. Benzoylecgonine reached a mean (+/- SEM) maximum concentration of 531.9 +/- 168.7 ng ml(-1) after 4 h, whereas ecgonine methyl ester peaked 2 h after injection at a concentration of 97.2 +/- 26.5 ng ml(-1). The maximum admissible concentration for cocaine and/or metabolites in the urine of horses is difficult to establish unequivocally because of the substantial individual variation in the drug elimination pattern observed in horses, which can be inferred by the large standard error of the means obtained. Copyright (C) 2002 John Wiley Sons, Ltd.
Resumo:
A simple and rapid method was developed for the determination of amfepramone hydrochloride, fenprorex, and diazepam in capsules using high performance liquid chromatography (HPLC) with UV detection. This procedure provided conditions for the separation of the active ingredient from the complex matrices of the dosage forms by extraction in methanol. Isocratic reversed phase chromatography was performed using acetonitrile, methanol, and aqueous 0,1% ammonium carbonate (50:10:40) as a mobile phase, LiChrospher 100 RP 18 column (125 x 5 mm id, 5 mu m), a column temperature of 25 +/- 1 degrees C and detection at 230 nm.The calibration curves were linear over a wide concentration range (20-2000 mu g.mL(-1) to amfepramone hydrochloride, 8-800 mu g.mL(-1) to fenproporex, and 4-200 mu g.mL(-1) to diazepam) and good analytical recovery (87.1 to 107.8%) was obtained. The method is accurate and precise, as well as having advantages such as simplicity and short duration of analysis. Twenty samples of pharmaceutical preparations labelled as natural products were analysed. Anorectics and diazepam, were detected in 40% of the samples.
Resumo:
A sensitive, accurate, reliable and easy method was developed for the quantification of oxamniquine in capsules using high-performance liquid chromatography (HPLC) with UV detection. This technique provided conditions for the separation of the active ingredient from the dosage form by extraction in methanol. Isocratic reversed phase chromatography was performed using methanol, water, and triethanolamine (60:40:0.099, v/v/w) (System C) or methanol, acetonitrile, water and formic acid (40:30:30:0.083, v/v/w) (System D) as mobile phase, a stainless steel column (125 x 4 mm i.d., 5 mum) filled with LiChrospher 100 RP-18 (Merck), column temperature of 28 +/- 2 degreesC and detection at 260 nm. The calibration curves were linear over a wide concentration range (1.0-20.0 mug ml(-1) of oxamniquine) to the Systems C and D with good correlation factor (0.9990 and 0.9982, respectively). The average content obtained were 100.1 +/- 1.5% (System C) and 102.4 +/- 0.8% (System D). The presence of lactose, starch, magnesium stearate and sodium laurylsulphate did not interfere in the results of the analysis. The above findings showed the proposed method to be both simple and added advantage of allowing for fast analysis. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
This article presented physicochemical characterization and rheological behavior evaluation of the liquid crystalline mesophases developed with different silicones. There were prepared 5 ternary systems, which were carried out the determination of the relative density, the electric conductivity and polarized light microscopy analysis, being selected two systems to promote the Preliminary Stability Tests. The results showed that System 1 obtained the major liquid crystal formation and a higher stability. The temperature influences in the systems stability and phases structure. In hot oven, observed oneself the mixture of lamellar and hexagonal phase, for both systems.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
A practical set of HPLC methods was developed for the separation and determination of the eggplant steroidal glycoalkaloids, solanine, chaconine, solasonine, solamargine, and their aglycones, solasodine and solanidine. A gradient method was initially developed, but proved to be neither robust nor practical. Three separate isocratic methods using acetonitrile and ammonium dihydrogen phosphate were developed and shown to be more repeatable, less subject to fluctuations in mobile phase composition, and less time consuming. The effect of adjusting buffer pH, column temperature, and buffer type (triethylammonium phosphate vs. ammonium dihydrogen phosphate) were evaluated. It was also discovered that, by addition of 10% methanol to the acetonitrile portion of the mobile phase, more control over the separations was possible. The use of methanol as a mobile phase entrainer greatly improved separations in some cases and its effectiveness was also dependent upon column temperature. Assessments of the method recovery, limit of detection, and limit of quantitation were made using extracts from S. melongena and S. linnaeanum.
Resumo:
Fluconazole, alpha-(2.4-diflurofenil)-alpha-(1H-triazol-1-methyl)-1H-1,2,4-triazol-1-ethanol, is an antifungal of the triazoles class. It shows activity against species of Candida sp. and it is indicated in cases of oropharyngeal candidiasis, esophageal, vaginal, and deep infection. Fluconazole is a selective inhibitor of ergosterol, a steroid exclusive of the cell membrane of fungal cells. Fluconazole is highly absorbed by the gastrointestinal tract and spreads easily by body fluids. The main adverse reactions related to the use of fluconazole are nausea, vomiting, headache, rash, abdominal pain, diarrhea, and alopecia in patients undergoing prolonged treatment with a dose of 400 mg/day. In the form of raw material, pharmaceutical formulations, or biological material, fluconazole can be determined by methods such as titration, spectrophotometry, and thin-layer, gas, and liquid chromatography. This article discusses the pharmacological and physicochemical properties of fluconazole and also the methods of analysis applied to the determination of the drug.
Resumo:
The objective of the current study was to develop and subsequently validate a simple, sensitive and precise reversed-phase LC method for the determination of ciprofloxacin hydrochloride in ophthalmic solution form. The chromatographic separation of ciprofloxacin hydrochloride was achieved on a Symmetry Waters C(18) column using UV detection at 275 nm. The optimized mobile phase consisted of 2.5% acetic acid solution: methanol:acetonitrile (70:15:15, v/v/v). The proposed method provided linear responses within the concentration range 1.0-6.0 mu g mL(-1) for ciprofloxacin hydrochloride. Correlation coefficient (r) for the ciprofloxacin hydrochloride was 0.9994. The precision of the method was demonstrated using intra- and inter-day assay RSD% values which were less than 5% in all instances. No interference from any components of pharmaceutical dosage forms was observed.
Resumo:
An analytical procedure using supercritical fluid extraction (SFE) and capillary gas chromatography with electron-capture detection was developed to determine simultaneously residues of different pesticides (organochlorine, organophosphorus, organonitrogen and pyrethroid) in honey samples. Fortification experiments were conducted to test conventional extraction (liquid-liquid) and optimize the extraction procedure in SFE by varying the CO2-modifier, temperature, extraction time and pressure. Best efficiency was achieved at 400 bar using acetonitrile as modifier at 90 degreesC. For the clean-up step, Florisil cartridges were used for both methods LLE and SFE. Recoveries for majority of pesticides from fortified samples of honey at fortification level of 0.01-0.10 mg/kg ranged 75-94% from both methods. Limits of detection found were less than 0.01 mg/kg for ECD and confirmation of pesticide identity was performed by gas chromatography-mass spectrometry in selected-ion monitoring mode. The multiresidue methods in real honey samples were applied and the results of developed methods were compared. (C) 2004 Elsevier B.V. All rights reserved.
Off line extraction of phenol from human urine sample with isoamyl alcohol and determination by HPLC
Resumo:
This method has been developed for extraction and determination of phenol in a urine sample by high performance liquid chromatography.After acid hydrolysis, the free phenol was extracted with isoamyl alcohol solvent, followed by back extraction with 0.5 mol.L-1 sodium hydroxide solution and analyzed by an isocratic HPLC Varian System, equipped with reverse-phase column (MicroPak-C-18). The mobile phase was acetonitrile in 0.01 mol.L-1 hydrochloric acid solution, (20:80 v/v), and at a now-rate of 1.0 mL.min-1. The chromatogram was monitored at 220 nm in room temperature. The identification was based on retention time and the quantification was performed by automatic peak-area determination, corrected for the external standards method.The recovery was higher than 99.5 % for phenol and reproducibility of method was shown to be 2.3% standard deviation and 5.6% coefficient of variance (n=20). The limit detection was 0.05 mgL(-1) and a range of 0.05 to 20.0 mgL(-1) of phenol for linearity.
Resumo:
This paper presents a simple, fast and sensitive method to determine chromic oxide (used as a biological marker of fish feed) in samples of fish feces by GFAAS through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The standard samples of feces and of fish feed containing 0.10-1.00 mg kg(-1) of Cr2O3 were pre-frozen for I min in liquid nitrogen and then ground a cryogenic mill for 2 min, which reduced the samples' grain size to less than 60 mu m. The standard slurries were prepared by mixing 20 mg of standard samples of fish feed or feces with I mL of a solution containing 0.05% (v/v) of Triton X-100 and 0.50% (v/v) of suprapure HNO3 directly in the spectrometer's automatic sampling glass. The final concentrations of Cr2O3 present in the standard slurries were 2, 4, 8, 16 and 20 mu g L-1. After sonicating the mixture for 20s, 10 mu L of standard slurries were injected into the graphite tube, whose internal wall was lined with a metallic palladium film that acted as a permanent chemical modifier. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (2%, m/v of feces or feed devoid of minerals) were 0.81 and 2.70 mu g L-1 of Cr2O3 for the standard feces slurries, 0.84 and 2.83 mu g L-1 of Cr2O3 for the standard feed slurries. The proposed method was applied in studies of nutrient digestibility of different fish feeds and its results proved compatible with the results obtained from samples pre-mineralized by acid digestion. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Objectives. The purpose of this paper is to modify the conventional calcium fluoro-aluminosilicate glass, which is used in the formation of glass ionomer cements (CIGs) by the niobium addition and to study the properties of GICs obtained.Materials and methods. Sol-gel process was used to prepare the powder at lower temperature than fusion method. Glass-ceramic powder obtained in this way was used to prepare the GICs. The properties such as working and setting times, microhardness and diametral tensile strength were evaluated for the experimental GICs and a commercial luting cement.Results. The ideal powder:liquid (P:L) ratio determined to prepare the experimental GICs was equal to 1:1. The cements prepared using this ratio showed working and setting times similar to the commercial GICs. in mechanical tests it was observed that microhardness and diametral tensile strength of the experimental GICs decreased significantly with the reduction of P:L ratio. on the other hand, the results obtained in microhardness tests indicated that the presence of niobium was a positive factor.Significance. The chemical process allows the development of glass-ceramic powder at 600 degrees C which is the goal of the present paper. It was concluded that GICs containing niobium might be used in dental applications and these results encourage further researches on other compositions. (c) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.