970 resultados para Inner tubes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: The Generalized Integral Transform Technique (GITT) is applied to the solution of the momentum equations in a hydrodynamically developing laminar flow of a non-Newtonian power-law fluid inside a circular duct. A primitive variables formulation is adopted in order to avoid the singularity of the auxiliary eigenvalue problem in terms of Bessel functions at the centerline of the duct when the GITT approach is applied. Results for the velocity field and friction factor-Reynolds number product are computed for different power-law indices, which are tabulated and graphically presented as functions of the dimensionless coordinates. Critical comparisons with previous results in the literature are also performed, in order to validate the numerical codes developed in the present work and to demonstrate the consistency of the final results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: The thermal entry region in laminar forced convection of Herschel-Bulkley fluids is solved analytically through the integral transform technique, for both circular and parallel-plates ducts, which are maintained at a prescribed wall temperature or at a prescribed wall heat flux. The local Nusselt numbers are obtained with high accuracy in both developing and fully-developed thermal regions, and critical comparisons with previously reported numerical results are performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho estuda o perfil metalúrgico de revestimentos em dutos depositados pelos processos MIG C e MIG AF. A indústria petroquímica, e outras que utilizam dutos como meio de transporte de seus insumos, depara-se com um grande desafio: como aumentar a vida útil desses dutos em um ambiente severo de trabalho. No caso específico da petroquímica, os dutos servem como meio de transporte para petróleo e gás, que são produtos extremamente agressivos às paredes internas desses tubos que sofrem degradação por corrosão causada, principalmente, pela composição química, pressão e temperatura desses produtos. Nesse contexto a soldagem de revestimentos realizada com ligas à base de Níquel, torna-se uma excelente opção para a construção, reparo e manutenção de equipamentos cuja aplicação seja voltada a ambientes severos de trabalho, tornando possível aperfeiçoar as características requeridas, como por exemplo, a resistência à corrosão. É nesse cenário que surge o mote para a realização desta pesquisa, baseada em trabalhos que indicam que o processo de soldagem MIG/MAG com o da adição de arame frio possui a finalidade de avaliar as características metalúrgicas do revestimento em dutos depositados pelo processo derivativo MIG convencional – MIG-C e MIG com adição de arame frio – MIG AF – utilizando a liga de Níquel ERNiCrMo-4 em dutos de aço carbono. As soldas foram depositadas em dutos de diâmetro de 228,6 mm, formando uma camada de revestimento interno de quatro passes, divididos em três segmentos da circunferência do duto, em três diferentes energias de soldagem: 1,1; 0,9 e 0,7 kJ/mm. Desses segmentos retiraram-se corpos de prova dos dutos para a produção das amostras. Após a metalografia, realizada nas amostras, seguiu-se com a análise e caracterização ao microscópio óptico, microscópio eletrônico de varredura e ensaio de microdureza. Os revestimentos apresentaram excelente qualidade superficial para todos os pacotes operacionais aplicados na obtenção das soldas. As análises das regiões estudadas: metal de base; zona parcialmente misturada e zona termicamente afetada, mostraram-se compatíveis com os da literatura estudada, tanto para o MIG com adição de arame frio, quanto para o convencional. Na ZTA, foram observados valores de Tungstênio em torno de 1,0%, o aumento dos níveis de dureza foi creditado a esse fato. Os resultados de microdureza indicaram que para ambos os casos, MIG C e MIG AF, nas 4 regiões analisadas ocorreram de maneira semelhante, sendo a região da ZTA a que apresentou maiores valores na faixa de 400 a 500 HV, enquanto que nas demais regiões a faixa ficou entre 250 a 350 HV. Os resultados indicam que o processo com arame frio, MIG AF, mostrou-se tão eficiente quanto o convencional, MIG C. A energia de soldagem aumentou a diluição de Fe no metal de solda. Precipitados ricos em Mo e Cr foram encontrados no metal de solda.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dawson and Murray-Clay (Dawson and Murray-Clay [2012]. Astrophys. J., 750, 43) pointed out that the inner part of the cold population in the Kuiper belt (that with semi major axis a < 43.5 AU) has orbital eccentricities significantly smaller than the limit imposed by stability constraints. Here, we confirm their result by looking at the orbital distribution and stability properties in proper element space. We show that the observed distribution could have been produced by the slow sweeping of the 4/7 mean motion resonance with Neptune that accompanied the end of Neptune's migration process. The orbital distribution of the hot Kuiper belt is not significantly affected in this process, for the reasons discussed in the main text. Therefore, the peculiar eccentricity distribution of the inner cold population cannot be unequivocally interpreted as evidence that the cold population formed in situ and was only moderately excited in eccentricity; it can simply be the signature of Neptune's radial motion, starting from a moderately eccentric orbit. We discuss how this agrees with a scenario of giant planet evolution following a dynamical instability and, possibly, with the radial transport of the cold population. (C) 2014 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a numerical model to simulate refrigerant flow through capillary tubes, commonly used as expansion devices in refrigeration systems. The flow is divided in a single-phase region, where the refrigerant is in the subcooled liquid state, and a region of two-phase flow. The capillary tube is considered straight and horizontal. The flow is taken as one-dimensional and adiabatic. Steady-state condition is also assumed and the metastable flow phenomena are neglected. The two-fluid model, considering the hydrodynamic and thermal non-equilibrium between the liquid and vapor phases, is applied to the two-phase flow region. Comparisons are made with experimental measurements of the mass flow rate and pressure distribution along two capillary tubes working with refrigerant R-134a in different operating conditions. The results indicate that the present model provides a better estimation than the commonly employed homogeneous model. Some computational results referring to the quality, void fraction, velocities, and temperatures of each phase are presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When a T-loop is used in segmental mechanics, it is generally attached posteriorly to an auxiliary tube in the first molars and anteriorly to a crimpable cross tube or a Burstone canine bracket. This article illustrates the use of a crimpable tube with a 90-degree bend on the base wire to secure a T-loop in segmental retraction. Both of these approaches allow a T-loop to be reactivated in a simple manner without undesirable changes in the system of forces, which could happen if the T-loop is skewed posteriorly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although vancomycin-resistant enterococci (VRE) are reported in Brazil since 1996, data on their impact over settings of different complexity are scarce. We performed a study aimed at identifying determinants ofVRE emergence and spread in a public hospital consortium (comprising 2 hospitals, with 318 and 57 beds) in inner Brazil. Molecular typing and case-control studies (addressing predictors of acquisition or clonality) were performed. Among 122 authocthonous isolates, 106 were Enterococcus faecium (22 clones), and 16, Enterococcus faecalis (5 clones). Incidence was greater in the small-sized hospital, and a previous admission to this hospital was associated with greater risk of VRE colonization or infection during admission to the larger one. Overall risk factors included comorbidities, procedures, and antimicrobials (piperacillin-tazobactam, cefepime, and imipenem). Risk factors varied among different hospitals, species, and clones. Our findings demonstrate that VRE can spread within low-complexity facilities and from these to larger hospitals. (C) 2015 Elsevier Inc. All rights reserved.