880 resultados para Historic buildings -- Colorado


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forms of integrated schooling are currently promoted in post-conflict Northern Ireland, but an earlier attempt to establish secular education in Ireland during the nineteenth and early twentieth centuries – the Irish National Schools system – is often forgotten. A preliminary archaeological study of former National Schools indicated differences in size, placement and external appearance between rural and urban buildings, possibly linked to the expression of divergent cultural and religious traditions in conflict with the reforming principles of the national system. This paper uses archaeological and anthropological perspectives to examine the social and cultural significance of such schools, including the first recorded excavation of an Irish National School, in relation to their past and current significance for education, identity, landscape, place and kinship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A methodology is presented that combines a multi-objective evolutionary algorithm and artificial neural networks to optimise single-storey steel commercial buildings for net-zero carbon impact. Both symmetric and asymmetric geometries are considered in conjunction with regulated, unregulated and embodied carbon. Offsetting is achieved through photovoltaic (PV) panels integrated into the roof. Asymmetric geometries can increase the south facing surface area and consequently allow for improved PV energy production. An exemplar carbon and energy breakdown of a retail unit located in Belfast UK with a south facing PV roof is considered. It was found in most cases that regulated energy offsetting can be achieved with symmetric geometries. However, asymmetric geometries were necessary to account for the unregulated and embodied carbon. For buildings where the volume is large due to high eaves, carbon offsetting became increasingly more difficult, and not possible in certain cases. The use of asymmetric geometries was found to allow for lower embodied energy structures with similar carbon performance to symmetrical structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design optimization of a cold-formed steel portal frame building is considered in this paper. The proposed genetic algorithm (GA) optimizer considers both topology (i.e., frame spacing and pitch) and cross-sectional sizes of the main structural members as the decision variables. Previous GAs in the literature were characterized by poor convergence, including slow progress, that usually results in excessive computation times and/or frequent failure to achieve an optimal or near-optimal solution. This is the main issue addressed in this paper. In an effort to improve the performance of the conventional GA, a niching strategy is presented that is shown to be an effective means of enhancing the dissimilarity of the solutions in each generation of the GA. Thus, population diversity is maintained and premature convergence is reduced significantly. Through benchmark examples, it is shown that the efficient GA proposed generates optimal solutions more consistently. A parametric study was carried out, and the results included. They show significant variation in the optimal topology in terms of pitch and frame spacing for a range of typical column heights. They also show that the optimized design achieved large savings based on the cost of the main structural elements; the inclusion of knee braces at the eaves yield further savings in cost, that are significant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The design optimization of cold-formed steel portal frame buildings is considered in this paper. The objective function is based on the cost of the members for the main frame and secondary members (i.e., purlins, girts, and cladding for walls and roofs) per unit area on the plan of the building. A real-coded niching genetic algorithm is used to minimize the cost of the frame and secondary members that are designed on the basis of ultimate limit state. It iis shown that the proposed algorithm shows effective and robust capacity in generating the optimal solution, owing to the population's diversity being maintained by applying the niching method. In the optimal design, the cost of purlins and side rails are shown to account for 25% of the total cost; the main frame members account for 27% of the total cost, claddings for the walls and roofs accounted for 27% of the total cost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimisation is based on a combination of neural networks and evolutionary algorithm. It has selected buildings with different midpoint configurations with zero carbon impacts. With operational energy included the structures could be offset with asymmetry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Copney Stone Circle Complex, Co. Tyrone, N. Ireland, is an important Bronze Age site forming part of the Mid-Ulster Stone Circle Complex. The Environment Service: Historic Monuments and Buildings (ESHMB) initiated a program of bog-clearance in August 1994 to excavate the stone circles. This work was completed by October 1994 and the excavated site was surveyed in August 1995. Almost immediately, the rate at which the stones forming the circles were breaking down was noted and a program of study initiated to make recommendations upon the conservation of this important site. Digital photogrammetric techniques were applied to aerial images of the stone circles and digital terrain models created from the images at a range of scales. These provide base data sets for comparison with identical surveys to be completed in successive years and will allow the rate of deterioration, and the areas most affected, of the circles to be determined. In addition, a 2D analysis of the stones provides an accurate analysis of the absolute 2D dimensions of the stones for rapid desktop computer analysis by researchers remote from the digital photogrammetric workstation used in the survey.

The products of this work are readily incorporated into web sites, educational packages and databases. The technique provides a rapid and user friendly method of presentation of a large body of information and measurements, and a reliable method of storage of the information from Copney should it become necessary to re-cover the site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper outlines a forensic method for analysing the energy, environmental and comfort performance of a building. The method has been applied to a recently developed event space in an Irish public building, which was evaluated using on-site field studies, data analysis, building simulation and occupant surveying. The method allows for consideration of both the technological and anthropological aspects of the building in use and for the identification of unsustainable operational practice and emerging problems. The forensic analysis identified energy savings of up to 50%, enabling a more sustainable, lower-energy operational future for the building. The building forensic analysis method presented in this paper is now planned for use in other public and commercial buildings.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Belfast city center is fractured, divided by motorways, parking lots, empty buildings, and big box stores. Its 19th-century heyday put it on the international map of textile production, which transformed and enriched its built structure. This tight architectural fabric was slowly destroyed in the 1940s by the Blitz, in the 1970s by road plans and “the troubles” and in the 1990s by large retail buildings. Few pedestrian streets traverse Belfast, and among them, most are recently-developed conduits for the passage of shoppers from one chain store to the next.Within this seemingly bleak urban landscape, there remain a few areas that offer a richer, more architecturally and socially diverse, more memory-laden conception of public space. Current redevelopment plans, however, threaten the mere existence of these few remaining historic streets in Belfast.This reality inspired the current project of one of the Masters in Architecture design units at Queen’s University Belfast. Our team (led by urban designer Michael Corr and myself) has been exploring North Street, one of the main arteries in Belfast City Center. Although North Street has a reputation for being run-down, derelict, and in need of redevelopment, it is one of the few intact 19th-century streets left in the area, and as such is worthy of study as an example of public space that is not strictly synonymous with commercial space.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Uma das maiores causas de degradação dos revestimentos é a presença de sais solúveis, tanto nas zonas costeiras como nas zonas continentais. Estes sais podem ter origens distintas, tais como: humidade ascensional, nevoeiro salino, inundações ou ainda estarem presentes nos próprios materiais, como é o caso da utilização de areias mal lavadas. O local onde os sais cristalizam é dependente do tipo de transporte entre a alvenaria e o revestimento, assim como da severidade da envolvente ambiental (temperatura e humidade relativa). Com esta tese pretende-se desenvolver revestimentos de substituição compatíveis, eficazes e duráveis para alvenarias antigas sujeitas à ação severa da água (humidade ascensional através das fundações com elevada concentração de NaCl); desenvolver ensaios de envelhecimento acelerado baseados em ciclos de dissolução e cristalização que permitam simular a ação severa da água; perceber a influência de revestimentos com caraterísticas extremas de permeabilidade ao vapor de água aplicados nas duas faces do mesmo suporte (argamassas de cimento e resina versus argamassas de cal), e sujeitos à ação severa da água; perceber a influência de vários fatores, tais como : rasgos verticais contínuos executados no emboço e a utilização de hidrófugo no reboco no desempenho dos vários sistemas de revestimento desenvolvidos, quando sujeitos à ação severa da água;; utilizar a remoção eletrocinética de sais, em provetes simulando a influência da alvenaria e dos revestimentos, com o objetivo de reduzir a sua concentração de NaCl, para que no futuro possa ser aplicado de forma eficaz em paredes de edifícios antigos, enquanto ação de manutenção, e desta forma aumentar a durabilidade dos revestimentos. Para atingir os objetivos descritos, foram considerados: i) o desenvolvimento de provetes que permitam considerar os sistemas de revestimento desenvolvidos nesta tese e o suporte, e que simulem uma alvenaria revestida em ambas as faces, e com os quais seja possível a simulação da ação severa da água em laboratório e, ii) o desenvolvimento ciclos de dissolução e cristalização numa parede de grandes dimensões existente em laboratório, que permitam simular a ação severa da água em condições tão reais quanto possível. O objetivo final deste estudo é o desenvolvimento de um revestimento de substituição denominado “emboço ventilado” para paredes de edifícios antigos com revestimentos degradados devido à presença de humidade ascensional e sais solúveis. Pretende-se que este sistema de revestimento, composto por duas camadas de revestimento (camada base e reboco), seja compatível, durável e eficaz, e que funcione como um sistema de acumulação no qual os sais cristalizem na camada base do sistema de revestimento (executada com rasgos verticais) e não na alvenaria ou na camada exterior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho analisa a valorização e salvaguarda do sistema construtivo das edificações de arquitetura civil do século XIX, frente às intervenções a que são submetidas, diante da necessidade de adaptação a usos e funções da vida contemporânea. Tem como estudo de caso o centro histórico de São Luís do Maranhão. Para sua elaboração, foram desenvolvidas as seguintes etapas: fundamentação teórica e conceitual do tema; análise dos aspectos da organização físico-espacial da arquitetura produzida no século XIX; leitura, análise e interpretação da constituição tipológica e estado de conservação do acervo arquitetônico do centro histórico de São Luís e verificação das intervenções referentes à conservação da integridade do sistema construtivo. Além da pesquisa, o trabalho apresenta algumas recomendações sobre a conservação da autenticidade do sistema construtivo das edificações patrimoniais, como forma de contribuição para orientar futuras intervenções de reabilitação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article examines the effectiveness of two innovative retrofitting solutions at enhancing the seismic behaviour of a substandard reinforced concrete building tested on a shake table as part of the Pan-European funded project BANDIT. To simulate typical substandard construction, the reinforcement of columns and beam-column joints of the full-scale structure had inadequate detailing. An initial series of shake table tests were carried out to assess the seismic behaviour of the bare building and the effectiveness of a first retrofitting intervention using Post-Tensioned Metal Straps. After these tests, columns and joints were repaired and subsequently retrofitted using a retrofitting solution consisting of Carbon Fibre Reinforced Polymers and Post-Tensioned Metal Straps applied on opposite frames of the building. The building was then subjected to unidirectional and three-dimensional incremental seismic excitations to assess the effectiveness of the two retrofitting solutions at improving the global and local building performance. The article provides details of the above shake table testing programme and retrofitting solutions, and discusses the test results in terms of the observed damage, global damage indexes, performance levels and local strains. It is shown that whilst the original bare building was significantly damaged at a peak ground acceleration (PGA) of 0.15g, the retrofitted building resisted severe threedimensional shake table tests up to PGA=0.60g without failure. Moreover, the retrofitting intervention enhanced the interstorey drift ratio capacity of the 1st and 2nd floors by 160% and 110%, respectively. Therefore, the proposed dual retrofitting system is proven to be very effective for improving the seismic performance of substandard buildings.