872 resultados para Hand-held devices
Resumo:
The case of a man exposed during 25 years to vibration while maneuvering a heavy earth moving tractor is reported. The first clinical manifestation of hand-arm vibration syndrome was a bilateral Raynaud's phenomenon followed five years later by digital necrosis. The arteriography revealed a proximal and bilateral ulnar artery occlusion. Bilateral median nerve conduction abnormalities were also present. Vibration exposure level was much higher than the threshold level proposed by the European Commission. Laboratory examinations for vasculitis and other vascular diseases were all negative. The purpose of this report is to show that vibration can be responsible for proximal occlusion of a medium sized artery and severe neurovascular abnormalities which must be distinguished from the usual vasospastic Raynaud's phenomenon and the classical hypothenar hammer syndrome. An early and correct diagnosis is crucial because continued repetitive trauma can result in irreversible ischemic injury and loss of digits.
Resumo:
A narrative of the history of the Soldiers' and Sailor's Monument on the State Capitol grounds.
Resumo:
Objective.- The Patient-Rated Wrist Evaluation is a specific questionnaire for the wrist [1]. It consists of 15 questions with a total score of 100. It was recently translated into French [2]. However, its validity has not been tested in this language. The Disabilities Arm Shoulder and Hand (DASH), with well-established psychometric properties, is considered as the reference questionnaire for the evaluation of upper extremities. The objective of this study is to measure the construct validity of the PRWE-F with the DASH-F in patients with wrist pathology.Patients and methods.- Fifty-one patients (40 m, 11 w, mean age 42 years), 25 fractures of the radius and 26 lesions of the carpus.Questionnaires PRWE-F and DASH-F at entry and at discharge (0 to 100). Calculation of the construct validity of the PRWE-F comparing with the DASH-F with Pearson correlation coefficients (r) at entry and at discharge. Level of significance (alpha) was set at 5%.Results.- Correlation DASH/PRWE at entry: r = 0.799 (95% CI 0.671 to 0.881), P < 0.0001. Correlation DASH/PRWE at discharge: r = 0.847 (95% CI: 0.745 to 0.910), P < 0.0001.Discussion.- The construct validity of the two instruments indicates that they measure the same concept. Our correlation between DASH-F and PRWE-F, going from 0.799 to 0.847, are comparable to those published in different languages (0.71 to 0.84) [3,4]. The questionnaires PRWE-F can thus be used in rehabilitation patients presenting with wrist pathologies; it is comparable to the DASH but described by MacDermid [1] to be more specific. Compared to the DASH it has the advantage of consisting of two dimensions. Its construct validity is excellent. This questionnaire should be evaluated in other populations, and it should be compared with hand questionnaires more specific than the DASH.
Resumo:
OBJECTIVE: The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS: Within a population-based survey in Dar es Salaam (Tanzania), we selected all participants with a blood pressure >/= 160/95 mmHg (n=653) and a random sample of participants with blood pressure <160/95 mmHg (n=662), based on the first blood pressure reading. Blood pressure was reassessed 2 years later for 464 and 410 of the participants, respectively. In these 874 subjects, we compared the prevalence of blood pressure categories as estimated with each device. RESULTS: Overall, the wrist device gave higher blood pressure readings than the arm device (difference in systolic/diastolic blood pressure: 6.3 +/- 17.3/3.7 +/- 11.8 mmHg, P<0.001). However, the arm device tended to give lower readings than the wrist device for high blood pressure values. The prevalence of blood pressure categories differed substantially depending on which device was used, 29% and 14% for blood pressure <120/80 mmHg (arm device versus wrist device, respectively), 30% and 33% for blood pressure 120-139/80-89 mmHg, 17% and 26% for blood pressure 140-159/90-99 mmHg, 12% and 13% for blood pressure 160-179/100-109 mmHg and 13% and 14% for blood pressure >/= 180/110 mmHg. CONCLUSIONS: A large discrepancy in the estimated prevalence of blood pressure categories was observed using two different automatic measurement devices. This emphasizes that prevalence estimates based on automatic devices should be considered with caution.
Resumo:
The potential for application of silicon nitride-based light sources to general lighting is reported. The mechanism of current injection and transport in silicon nitride layers and silicon oxide tunnel layers is determined by electro-optical characterization of both bi- and tri-layers. It is shown that red luminescence is due to bipolar injection by direct tunneling, whereas Poole-Frenkel ionization is responsible for blue-green emission. The emission appears warm white to the eye, and the technology has potential for large-area lighting devices. A photometric study, including color rendering, color quality and luminous efficacy of radiation, measured under various AC excitation conditions, is given for a spectrum deemed promising for lighting. A correlated color temperature of 4800K was obtained using a 35% duty cycle of the AC excitation signal. Under these conditions, values for general color rendering index of 93 and luminous efficacy of radiation of 112 lm/W are demonstrated. This proof of concept demonstrates that mature silicon technology, which is extendable to lowcost, large-area lamps, can be used for general lighting purposes. Once the external quantum efficiency is improved to exceed 10%, this technique could be competitive with other energy-efficient solid-state lighting options. ©2011 Optical Society of America OCIS codes: (230.2090) Electro-optical devices; (150.2950) Illumination.
Resumo:
High optical power density of 0.5 mW/cm2, external quantum efficiency of 0.1%, and population inversion of 7% are reported from Tb+-implanted silicon-rich silicon nitride/oxide light emitting devices. Electrical and electroluminescence mechanisms in these devices were investigated. The excitation cross section for the 543 nm Tb3+ emission was estimated under electrical pumping, resulting in a value of 8.2 × 10−14 cm2, which is one order of magnitude larger than one reported for Tb3+:SiO2 light emitting devices. These results demonstrate the potentiality of Tb+-implanted silicon nitride material for the development of integrated light sources compatible with Si technology.
The effects of electron-hole separation on the photoconductivity of individual metal oxide nanowires
Resumo:
The responses of individual ZnO nanowires to UV light demonstrate that the persistent photoconductivity (PPC) state is directly related to the electron¿hole separation near the surface. Our results demonstrate that the electrical transport in these nanomaterials is influenced by the surface in two different ways. On the one hand, the effective mobility and the density of free carriers are determined by recombination mechanisms assisted by the oxidizing molecules in air. This phenomenon can also be blocked by surface passivation. On the other hand, the surface built-in potential separates the photogenerated electron¿hole pairs and accumulates holes at the surface. After illumination, the charge separation makes the electron¿hole recombination difficult and originates PPC. This effect is quickly reverted after increasing either the probing current (self-heating by Joule dissipation) or the oxygen content in air (favouring the surface recombination mechanisms). The model for PPC in individual nanowires presented here illustrates the intrinsic potential of metal oxide nanowires to develop optoelectronic devices or optochemical sensors with better and new performances.
Resumo:
BACKGROUND: Electrophysiological cardiac devices are increasingly used. The frequency of subclinical infection is unknown. We investigated all explanted devices using sonication, a method for detection of microbial biofilms on foreign bodies. METHODS AND RESULTS: Consecutive patients in whom cardiac pacemakers and implantable cardioverter/defibrillators were removed at our institution between October 2007 and December 2008 were prospectively included. Devices (generator and/or leads) were aseptically removed and sonicated, and the resulting sonication fluid was cultured. In parallel, conventional swabs of the generator pouch were performed. A total of 121 removed devices (68 pacemakers, 53 implantable cardioverter/defibrillators) were included. The reasons for removal were insufficient battery charge (n=102), device upgrading (n=9), device dysfunction (n=4), or infection (n=6). In 115 episodes (95%) without clinical evidence of infection, 44 (38%) grew bacteria in sonication fluid, including Propionibacterium acnes (n=27), coagulase-negative staphylococci (n=11), Gram-positive anaerobe cocci (n=3), Gram-positive anaerobe rods (n=1), Gram-negative rods (n=1), and mixed bacteria (n=1). In 21 of 44 sonication-positive episodes, bacterial counts were significant (>or=10 colony-forming units/mL of sonication fluid). In 26 sterilized controls, sonication cultures remained negative in 25 cases (96%). In 112 cases without clinical infection, conventional swab cultures were performed: 30 cultures (27%) were positive, and 18 (60%) were concordant with sonication fluid cultures. Six devices and leads were removed because of infection, growing Staphylococcus aureus, Streptococcus mitis, and coagulase-negative staphylococci in 6 sonication fluid cultures and 4 conventional swab cultures. CONCLUSIONS: Bacteria can colonize cardiac electrophysiological devices without clinical signs of infection.
Resumo:
The optimization of the extremity dosimetry of medical staff in nuclear medicine was the aim of the Work Package 4 (WP4) of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Programme. Hand doses and dose distributions across the hands of medical staff working in nuclear medicine departments were evaluated through an extensive measurement program involving 32 hospitals in Europe and 139 monitored workers. The study included the most frequently used radionuclides, (99m)Tc- and (18)F-labelled radiopharmaceuticals for diagnostic and (90)Y-labelled Zevalin (R) and DOTATOC for therapy. Furthermore, Monte Carlo simulations were performed in different predefined scenarios to evaluate separately the efficacy of different radiation protection measures by comparing hand dose distributions according to various parameters. The present work gives recommendations based on results obtained with both measurements and simulations. This results in nine practical recommendations regarding the positioning of the dosemeters for an appropriate skin dose monitoring and the best protection means to reduce the personnel exposure.
Resumo:
The case of a professional tennis player presenting exercise-induced hand pain with late appearance of digital blanching is reported. A bilateral hypothenar hammer syndrome and stenosis of the common palmar digital arteries close to the head of the metacarpals where the racket handle exerts its maximal force was observed with arteriography. As the patient decided to stop tennis practice, the condition improved without any medication. Six months after stopping tennis he was symptom free. Three conclusions can be drawn from this case report: 1) arteries of both hands can be injured by intense tennis practice, 2) pain in the dominant hand during tennis practice can be due to arterial insufficiency even in the absence of digital blanching which is a sign of severity, 3) hypothenar hammer syndrome is the main cause but stenosis of the common palmar digital arteries can possibly contribute to the ischemic phenomenon. Early recognition is important to avoid ineffective treatment and permanent symptoms. Therefore, we recommend an arterial examination in tennis players suffering from exercise-induced hand pain even in the absence of digital blanching which can be only a late manifestation.
Resumo:
Abstract : The occupational health risk involved with handling nanoparticles is the probability that a worker will experience an adverse health effect: this is calculated as a function of the worker's exposure relative to the potential biological hazard of the material. Addressing the risks of nanoparticles requires therefore knowledge on occupational exposure and the release of nanoparticles into the environment as well as toxicological data. However, information on exposure is currently not systematically collected; therefore this risk assessment lacks quantitative data. This thesis aimed at, first creating the fundamental data necessary for a quantitative assessment and, second, evaluating methods to measure the occupational nanoparticle exposure. The first goal was to determine what is being used where in Swiss industries. This was followed by an evaluation of the adequacy of existing measurement methods to assess workplace nanopaiticle exposure to complex size distributions and concentration gradients. The study was conceived as a series of methodological evaluations aimed at better understanding nanoparticle measurement devices and methods. lt focused on inhalation exposure to airborne particles, as respiration is considered to be the most important entrance pathway for nanoparticles in the body in terms of risk. The targeted survey (pilot study) was conducted as a feasibility study for a later nationwide survey on the handling of nanoparticles and the applications of specific protection means in industry. The study consisted of targeted phone interviews with health and safety officers of Swiss companies that were believed to use or produce nanoparticles. This was followed by a representative survey on the level of nanoparticle usage in Switzerland. lt was designed based on the results of the pilot study. The study was conducted among a representative selection of clients of the Swiss National Accident Insurance Fund (SUVA), covering about 85% of Swiss production companies. The third part of this thesis focused on the methods to measure nanoparticles. Several pre- studies were conducted studying the limits of commonly used measurement devices in the presence of nanoparticle agglomerates, This focus was chosen, because several discussions with users and producers of the measurement devices raised questions about their accuracy measuring nanoparticle agglomerates and because, at the same time, the two survey studies revealed that such powders are frequently used in industry. The first preparatory experiment focused on the accuracy of the scanning mobility particle sizer (SMPS), which showed an improbable size distribution when measuring powders of nanoparticle agglomerates. Furthermore, the thesis includes a series of smaller experiments that took a closer look at problems encountered with other measurement devices in the presence of nanoparticle agglomerates: condensation particle counters (CPC), portable aerosol spectrometer (PAS) a device to estimate the aerodynamic diameter, as well as diffusion size classifiers. Some initial feasibility tests for the efficiency of filter based sampling and subsequent counting of carbon nanotubes (CNT) were conducted last. The pilot study provided a detailed picture of the types and amounts of nanoparticles used and the knowledge of the health and safety experts in the companies. Considerable maximal quantities (> l'000 kg/year per company) of Ag, Al-Ox, Fe-Ox, SiO2, TiO2, and ZnO (mainly first generation particles) were declared by the contacted Swiss companies, The median quantity of handled nanoparticles, however, was 100 kg/year. The representative survey was conducted by contacting by post mail a representative selection of l '626 SUVA-clients (Swiss Accident Insurance Fund). It allowed estimation of the number of companies and workers dealing with nanoparticles in Switzerland. The extrapolation from the surveyed companies to all companies of the Swiss production sector suggested that l'309 workers (95%-confidence interval l'073 to l'545) of the Swiss production sector are potentially exposed to nanoparticles in 586 companies (145 to l'027). These numbers correspond to 0.08% (0.06% to 0.09%) of all workers and to 0.6% (0.2% to 1.1%) of companies in the Swiss production sector. To measure airborne concentrations of sub micrometre-sized particles, a few well known methods exist. However, it was unclear how well the different instruments perform in the presence of the often quite large agglomerates of nanostructured materials. The evaluation of devices and methods focused on nanoparticle agglomerate powders. lt allowed the identification of the following potential sources of inaccurate measurements at workplaces with considerable high concentrations of airborne agglomerates: - A standard SMPS showed bi-modal particle size distributions when measuring large nanoparticle agglomerates. - Differences in the range of a factor of a thousand were shown between diffusion size classifiers and CPC/SMPS. - The comparison between CPC/SMPS and portable aerosol Spectrometer (PAS) was much better, but depending on the concentration, size or type of the powders measured, the differences were still of a high order of magnitude - Specific difficulties and uncertainties in the assessment of workplaces were identified: the background particles can interact with particles created by a process, which make the handling of background concentration difficult. - Electric motors produce high numbers of nanoparticles and confound the measurement of the process-related exposure. Conclusion: The surveys showed that nanoparticles applications exist in many industrial sectors in Switzerland and that some companies already use high quantities of them. The representative survey demonstrated a low prevalence of nanoparticle usage in most branches of the Swiss industry and led to the conclusion that the introduction of applications using nanoparticles (especially outside industrial chemistry) is only beginning. Even though the number of potentially exposed workers was reportedly rather small, it nevertheless underscores the need for exposure assessments. Understanding exposure and how to measure it correctly is very important because the potential health effects of nanornaterials are not yet fully understood. The evaluation showed that many devices and methods of measuring nanoparticles need to be validated for nanoparticles agglomerates before large exposure assessment studies can begin. Zusammenfassung : Das Gesundheitsrisiko von Nanopartikel am Arbeitsplatz ist die Wahrscheinlichkeit dass ein Arbeitnehmer einen möglichen Gesundheitsschaden erleidet wenn er diesem Stoff ausgesetzt ist: sie wird gewöhnlich als Produkt von Schaden mal Exposition gerechnet. Für eine gründliche Abklärung möglicher Risiken von Nanomaterialien müssen also auf der einen Seite Informationen über die Freisetzung von solchen Materialien in die Umwelt vorhanden sein und auf der anderen Seite solche über die Exposition von Arbeitnehmenden. Viele dieser Informationen werden heute noch nicht systematisch gesarnmelt und felilen daher für Risikoanalysen, Die Doktorarbeit hatte als Ziel, die Grundlagen zu schaffen für eine quantitative Schatzung der Exposition gegenüber Nanopartikel am Arbeitsplatz und die Methoden zu evaluieren die zur Messung einer solchen Exposition nötig sind. Die Studie sollte untersuchen, in welchem Ausmass Nanopartikel bereits in der Schweizer Industrie eingesetzt werden, wie viele Arbeitnehrner damit potentiel] in Kontakt komrrien ob die Messtechnologie für die nötigen Arbeitsplatzbelastungsmessungen bereits genügt, Die Studie folcussierte dabei auf Exposition gegenüber luftgetragenen Partikel, weil die Atmung als Haupteintrittspforte iïlr Partikel in den Körper angesehen wird. Die Doktorarbeit besteht baut auf drei Phasen auf eine qualitative Umfrage (Pilotstudie), eine repräsentative, schweizerische Umfrage und mehrere technische Stndien welche dem spezitischen Verständnis der Mëglichkeiten und Grenzen einzelner Messgeräte und - teclmikeri dienen. Die qualitative Telephonumfrage wurde durchgeführt als Vorstudie zu einer nationalen und repräsentativen Umfrage in der Schweizer Industrie. Sie zielte auf Informationen ab zum Vorkommen von Nanopartikeln, und den angewendeten Schutzmassnahmen. Die Studie bestand aus gezielten Telefoninterviews mit Arbeit- und Gesundheitsfachpersonen von Schweizer Unternehmen. Die Untemehmen wurden aufgrund von offentlich zugànglichen lnformationen ausgewählt die darauf hinwiesen, dass sie mit Nanopartikeln umgehen. Der zweite Teil der Dolctorarbeit war die repräsentative Studie zur Evalniernng der Verbreitnng von Nanopaitikelanwendungen in der Schweizer lndustrie. Die Studie baute auf lnformationen der Pilotstudie auf und wurde mit einer repräsentativen Selektion von Firmen der Schweizerischen Unfall Versicherungsanstalt (SUVA) durchgeüihxt. Die Mehrheit der Schweizerischen Unternehmen im lndustrieselctor wurde damit abgedeckt. Der dritte Teil der Doktorarbeit fokussierte auf die Methodik zur Messung von Nanopartikeln. Mehrere Vorstudien wurden dnrchgefîihrt, um die Grenzen von oft eingesetzten Nanopartikelmessgeräten auszuloten, wenn sie grösseren Mengen von Nanopartikel Agglomeraten ausgesetzt messen sollen. Dieser F okns wurde ans zwei Gründen gewählt: weil mehrere Dislcussionen rnit Anwendem und auch dem Produzent der Messgeràte dort eine Schwachstelle vermuten liessen, welche Zweifel an der Genauigkeit der Messgeräte aufkommen liessen und weil in den zwei Umfragestudien ein häufiges Vorkommen von solchen Nanopartikel-Agglomeraten aufgezeigt wurde. i Als erstes widmete sich eine Vorstndie der Genauigkeit des Scanning Mobility Particle Sizer (SMPS). Dieses Messgerät zeigte in Präsenz von Nanopartikel Agglorneraten unsinnige bimodale Partikelgrössenverteilung an. Eine Serie von kurzen Experimenten folgte, welche sich auf andere Messgeräte und deren Probleme beim Messen von Nanopartikel-Agglomeraten konzentrierten. Der Condensation Particle Counter (CPC), der portable aerosol spectrometer (PAS), ein Gerät zur Schàtzung des aerodynamischen Durchniessers von Teilchen, sowie der Diffusion Size Classifier wurden getestet. Einige erste Machbarkeitstests zur Ermittlnng der Effizienz von tilterbasierter Messung von luftgetragenen Carbon Nanotubes (CNT) wnrden als letztes durchgeiührt. Die Pilotstudie hat ein detailliiertes Bild der Typen und Mengen von genutzten Nanopartikel in Schweizer Unternehmen geliefert, und hat den Stand des Wissens der interviewten Gesundheitsschntz und Sicherheitsfachleute aufgezeigt. Folgende Typen von Nanopaitikeln wurden von den kontaktierten Firmen als Maximalmengen angegeben (> 1'000 kg pro Jahr / Unternehrnen): Ag, Al-Ox, Fe-Ox, SiO2, TiO2, und ZnO (hauptsächlich Nanopartikel der ersten Generation). Die Quantitäten von eingesetzten Nanopartikeln waren stark verschieden mit einem ein Median von 100 kg pro Jahr. ln der quantitativen Fragebogenstudie wurden l'626 Unternehmen brieflich kontaktiert; allesamt Klienten der Schweizerischen Unfallversicherringsanstalt (SUVA). Die Resultate der Umfrage erlaubten eine Abschätzung der Anzahl von Unternehmen und Arbeiter, welche Nanopartikel in der Schweiz anwenden. Die Hochrechnung auf den Schweizer lndnstriesektor hat folgendes Bild ergeben: ln 586 Unternehmen (95% Vertrauensintervallz 145 bis 1'027 Unternehmen) sind 1'309 Arbeiter potentiell gegenüber Nanopartikel exponiert (95%-Vl: l'073 bis l'545). Diese Zahlen stehen für 0.6% der Schweizer Unternehmen (95%-Vl: 0.2% bis 1.1%) und 0.08% der Arbeiternehmerschaft (95%-V1: 0.06% bis 0.09%). Es gibt einige gut etablierte Technologien um die Luftkonzentration von Submikrometerpartikel zu messen. Es besteht jedoch Zweifel daran, inwiefern sich diese Technologien auch für die Messurrg von künstlich hergestellten Nanopartikeln verwenden lassen. Aus diesem Grund folcussierten die vorbereitenden Studien für die Arbeitsplatzbeurteilnngen auf die Messung von Pulverri, welche Nan0partike1-Agg10merate enthalten. Sie erlaubten die ldentifikation folgender rnöglicher Quellen von fehlerhaften Messungen an Arbeitsplätzen mit erhöhter Luft-K0nzentrati0n von Nanopartikel Agglomeratenz - Ein Standard SMPS zeigte eine unglaubwürdige bimodale Partikelgrössenverteilung wenn er grössere Nan0par'til<e1Agg10merate gemessen hat. - Grosse Unterschiede im Bereich von Faktor tausend wurden festgestellt zwischen einem Diffusion Size Classiîier und einigen CPC (beziehungsweise dem SMPS). - Die Unterschiede zwischen CPC/SMPS und dem PAS waren geringer, aber abhängig von Grosse oder Typ des gemessenen Pulvers waren sie dennoch in der Grössenordnung von einer guten Grössenordnung. - Spezifische Schwierigkeiten und Unsicherheiten im Bereich von Arbeitsplatzmessungen wurden identitiziert: Hintergrundpartikel können mit Partikeln interagieren die während einem Arbeitsprozess freigesetzt werden. Solche Interaktionen erschweren eine korrekte Einbettung der Hintergrunds-Partikel-Konzentration in die Messdaten. - Elektromotoren produzieren grosse Mengen von Nanopartikeln und können so die Messung der prozessbezogenen Exposition stören. Fazit: Die Umfragen zeigten, dass Nanopartikel bereits Realitàt sind in der Schweizer Industrie und dass einige Unternehmen bereits grosse Mengen davon einsetzen. Die repräsentative Umfrage hat diese explosive Nachricht jedoch etwas moderiert, indem sie aufgezeigt hat, dass die Zahl der Unternehmen in der gesamtschweizerischen Industrie relativ gering ist. In den meisten Branchen (vor allem ausserhalb der Chemischen Industrie) wurden wenig oder keine Anwendungen gefunden, was schliessen last, dass die Einführung dieser neuen Technologie erst am Anfang einer Entwicklung steht. Auch wenn die Zahl der potentiell exponierten Arbeiter immer noch relativ gering ist, so unterstreicht die Studie dennoch die Notwendigkeit von Expositionsmessungen an diesen Arbeitsplätzen. Kenntnisse um die Exposition und das Wissen, wie solche Exposition korrekt zu messen, sind sehr wichtig, vor allem weil die möglichen Auswirkungen auf die Gesundheit noch nicht völlig verstanden sind. Die Evaluation einiger Geräte und Methoden zeigte jedoch, dass hier noch Nachholbedarf herrscht. Bevor grössere Mess-Studien durgefîihrt werden können, müssen die Geräte und Methodem für den Einsatz mit Nanopartikel-Agglomeraten validiert werden.
Resumo:
A mathematical model that describes the behavior of low-resolution Fresnel lenses encoded in any low-resolution device (e.g., a spatial light modulator) is developed. The effects of low-resolution codification, such the appearance of new secondary lenses, are studied for a general case. General expressions for the phase of these lenses are developed, showing that each lens behaves as if it were encoded through all pixels of the low-resolution device. Simple expressions for the light distribution in the focal plane and its dependence on the encoded focal length are developed and commented on in detail. For a given codification device an optimum focal length is found for best lens performance. An optimization method for codification of a single lens with a short focal length is proposed.
Resumo:
The Monte San Giorgio (Southern Alps, Ticino, Switzerland) is the most important locality in the world for vertebrates dating back to the Middle Triassic. For this reason it was registered in 2003 as a UNESCO World Heritage Site. One of the objectives of this doctoral thesis was to fill some of the cognitive gaps regarding the Ladinian succession, including in particular the San Giorgio Dolomite and the Meride Limestone. In order to achieve this, the entire succession, more than 600 metres thick, was measured and sampled. Biostratigraphic research based on new finds of fossil invertebrates and microfossils and on the palynological analysis of the entire section was integrated with single-zircon U-Pb dating of volcanic ash layers intercalated in the carbonate succession. This enabled a redefinition of the bio-chronostratigraphic and geochronologic framework of the succession, which encompasses a significantly shorter time interval than previously held. The Ladinian section extends from the E. curionii Ammonoid Zone (Early Fassanian) to the P. archelaus Ammonoid Zone (Early Longobardian). The age of the classic fossiliferous levels of the Meride Limestone, rich in organic matter and containing vertebrate fossils which are known all over the world, was defined in both biostratigraphic and geochronologic terms. The presumed stratigraphie significance of the pachypleurosaurid reptiles found in such levels is called into question by new finds. These fossiliferous horizons were found to correspond to the main volcanoclastic intervals of the Buchenstein Formation (Middle and Upper Pietra Verde). Thus, a correlation with the Bagolino Section (Italy) containing the GSSP for the base of the Ladinian was proposed. Bulk sedimentation rates in the studied succession average 200 m/Myr and therefore prove to be 20 times higher than those of the South-Alpine pelagic basins. These values express high carbonate productivity from the surrounding platforms on one hand, and on the other a marked subsidence of the basin. Only in the intervals consisting of laminated limestones did the sedimentation rates drop to average values of around 30 m/Myr. The distribution of organic and inorganic facies appears to be the consequence of relative variations in sea-level. The laminated and organic-matter- rich intervals of the Meride Limestone are linked to a relative sea-level drop which favoured dysoxic to anoxic bottom-water conditions, coupled with an increase in runoff, perhaps due to recurrent explosive volcanic activity. The transient development under dysoxic conditions of monospecific benthic meio-/macrofaunas was documented. Organic matter suggests a predominant origin due to benthic bacterial activity, as can be witnessed in alveolar structures typical of exopolymeric substances secreted by bacteria within microbial mats. A microbial contribution to the carbonate (peloidal) precipitation was documented. The protective effect exerted by these microbial mats is also indicated as the main taphonomic factor contributing to the excellent preservation of vertebrate fossils. A radiolarian assemblage discovered in the lower part of the section (earliest Ladinian, E. curionii Zone) suggests the transient existence of open-marine but not deep-water connections with the tethyan pelagic basins. It shows marked similarities to the faunas typical of the late Anisian, suggesting therefore a low resolution power provided by radiolarian biostratigraphy in recognizing the Anisian/Ladinian boundary. The present thesis describes a new species of conifer (Elatocladus cassinae), a new species of insect (Dasyleptus triassicus) and seven new species of radiolarians (Eptingium danieli, Eptingium neriae, Parentactinosphaera eoladinica, Sepsagon ticinensis, Sepsagon? valporinae, Novamuria wirzi and Pessagnollum? hexaspinosum). In addition, following revision of the type material of already existent taxa, four new genera of radiolarians are introduced: Bernoulliella, Eohexastylus, Ticinosphaera and Lahmosphaera.