988 resultados para Groundwater flow


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of the rabies neutralizing antibody (VNA) response after immunization against rabies is an acceptable index of the efficacy of a vaccine and a successful treatment. Several tests have been developed in attempt to improve the assessment of VNA, from mice inoculation to cell-culture fluorescence inhibition tests. All of them, however, present special difficulties in terms of reading or accuracy. The present study describes a neutralization test performed in cell-culture appraised by flow cytometry (FC). Serial dilutions of the serum samples were mixed in vitro with rabies virus before the addition of BHK-21 cells. After 24h-incubation, cells were released by trypsin treatment, fixed and permeabilized with a p-formaldehyde solution and stained with a rabies virus nucleocapsid protein-specific antibody conjugate. The percentage of virus infection inhibition caused by specific antibodies present in the serum were evaluated in a Beckton & Dickinson FACSCalibur® flow cytometer. A correlation curve between the IU/ml content and the percentage of infective inhibition was built with a reference serum and the VNA titers of serum samples were obtained by extrapolation. Titers obtained by FC and standard test showed an effective pairing results (p < 0.01), with a correlation coefficient (r) = 0.7. These results permit to envisage the FC as a suitable technique to evaluate VNA in sera from immunized animals and likely in human serum samples. Nevertheless, new studies comparing FC to gold-standard techniques are required for determining the FC values of Sensibility and Specificity .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accepted in 13th IEEE Symposium on Embedded Systems for Real-Time Multimedia (ESTIMedia 2015), Amsterdam, Netherlands.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sulfadiazine is an antibiotic of the sulfonamide group and is used as a veterinary drug in fish farming. Monitoring it in the tanks is fundamental to control the applied doses and avoid environmental dissemination. Pursuing this goal, we included a novel potentiometric design in a flow-injection assembly. The electrode body was a stainless steel needle veterinary syringe of 0.8-mm inner diameter. A selective membrane of PVC acted as a sensory surface. Its composition, the length of the electrode, and other flow variables were optimized. The best performance was obtained for sensors of 1.5-cm length and a membrane composition of 33% PVC, 66% onitrophenyloctyl ether, 1% ion exchanger, and a small amount of a cationic additive. It exhibited Nernstian slopes of 61.0 mV decade-1 down to 1.0×10-5 mol L-1, with a limit of detection of 3.1×10-6 mol L-1 in flowing media. All necessary pH/ionic strength adjustments were performed online by merging the sample plug with a buffer carrier of 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid, pH 4.9. The sensor exhibited the advantages of a fast response time (less than 15 s), long operational lifetime (60 days), and good selectivity for chloride, nitrite, acetate, tartrate, citrate, and ascorbate. The flow setup was successfully applied to the analysis of aquaculture waters. The analytical results were validated against those obtained with liquid chromatography–tandem mass spectrometry procedures. The sampling rate was about 84 samples per hour and recoveries ranged from 95.9 to 106.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The local fractional Burgers’ equation (LFBE) is investigated from the point of view of local fractional conservation laws envisaging a nonlinear local fractional transport equation with a linear non-differentiable diffusion term. The local fractional derivative transformations and the LFBE conversion to a linear local fractional diffusion equation are analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Canadian Journal of Civil Engineering 36(10) 1605–16

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The excessive use of pesticides and fertilisers in agriculture has generated a decrease in groundwater and surface water quality in many regions of the EU, constituting a hazard for human health and the environment. Besides, on-site sewage disposal is an important source of groundwater contamination in urban and peri-urban areas. The assessment of groundwater vulnerability to contamination is an important tool to fulfil the demands of EU Directives. The purpose of this study is to assess the groundwater vulnerability to contamination related mainly to agricultural activities in a peri-urban area (Vila do Conde, NW Portugal). The hydrogeological framework is characterised mainly by fissured granitic basement and sedimentary cover. Water samples were collected and analysed for temperature, pH, electrical conductivity, chloride, phosphate, nitrate and nitrite. An evaluation of groundwater vulnerability to contamination was applied (GOD-S, Pesticide DRASTIC-Fm, SINTACS and SI) and the potential nitrate contamination risk was assessed, both on a hydrogeological GIS-based mapping. A principal component analysis was performed to characterised patterns of relationship among groundwater contamination, vulnerability, and the hydrogeological setting assessed. Levels of nitrate above legislation limits were detected in 75 % of the samples analysed. Alluvia units showed the highest nitrate concentrations and also the highest vulnerability and risk. Nitrate contamination is a serious problem affecting groundwater, particularly shallow aquifers, especially due to agriculture activities, livestock and cesspools. GIS-based cartography provided an accurate way to improve knowledge on water circulation models and global functioning of local aquifer systems. Finally, this study highlights the adequacy of an integrated approach, combining hydrogeochemical data, vulnerability assessments and multivariate analysis, to understand groundwater processes in peri-urban areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hard‐rock watersheds commonly exhibit complex geological bedrock and morphological features. Hydromineral resources have relevant economic value for the thermal spas industry. The present study aims to develop a groundwater vulnerability approach in Caldas da Cavaca hydromineral system (Aguiar da Beira, Central Portugal) which has a thermal tradition that dates back to the late 19th century, and contribute to a better understanding of the hydrogeological conceptual site model. In this work different layers were overlaid, generating several thematic maps to arrive at an integrated framework of several key‐sectors in Caldas da Cavaca site. Thus, to accomplish a comprehensive analysis and conceptualization of the site, a multi‐technical approach was used, such as, field and laboratory techniques, where several data was collected, like geotectonics, hydrology and hydrogeology, hydrogeomorphology, hydrogeophysical and hydrogeomechanical zoning aiming the application of the so‐called DISCO method. All these techniques were successfully performed and a groundwater vulnerability to contamination assessment, based on GOD‐S, DRASTIC‐Fm, SINTACS, SI and DISCO indexes methodology, was delineated. Geographical Information Systems (GIS) technology was on the basis to organise and integrate the geodatabases and to produce all the thematic maps. This multi‐technical approach highlights the importance of groundwater vulnerability to contamination mapping as a tool to support hydrogeological conceptualisation, contributing to better decision‐making of water resources management and sustainability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O presente estudo centra‐se na conceptualização de pormenor do modelo de circulação do aquífero termomineral de Chaves na sua zona de descarga no campo hidromineral e geotérmico de Chaves (Norte de Portugal). Para tal, utilizam‐se as informações resultantes da bibliografia disponível, da construção das captações de água termomineral AC1 e AC2, já existentes, e, principalmente, as informações obtidas a partir dos trabalhos de pesquisa, prospecção e construção da captação CC3, obra desenvolvida no ano de 2014 para reforço de caudal das Caldas de Chaves. Incidindo fundamentalmente na análise de perfis geofísicos, de parâmetros de perfuração, “cuttings” e diagrafias diferidas inerentes à sondagem de pesquisa CC3, e da sua posterior transformação em captação, integrando‐se posteriormente toda a informação daí resultante, o estudo culmina na apresentação de um modelo conceptual de pormenor para a circulação de águas tipo “Chaves” na zona de descarga que permite, com considerável robustez, à luz dos dados conhecidos à presente data, o melhor conhecimento do aquífero para futuros projectos de desenvolvimento dos recursos hidrominerais e geotérmicos de Chaves.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Informática

Relevância:

20.00% 20.00%

Publicador:

Resumo:

SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg) in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex) or enzyme-linked immunoassay (EIA) has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA) was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered). CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Finance from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

21st Annual Conference of the International Group for Lean Construction – IGLC 21 – Fortaleza, Brazil

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a rapid method for the flow cytometric quantitation of phagocytosis in heparinized complete peripherial blood (HCPB), using commercially available phycoerythrin-conjugated latex particles of 1µm diameter. The method is faster and shows greater reproducibility than Bjerknes' (1984) standard technique using propidium iodide-stained Candida albicans, conventionally applied to the leukocytic layer of peripherial blood but here modified for HCPB. We also report a modification of Bjerknes' Intracellular Killing Test to allow its application to HCPB.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mycobaterium leprae infection was investigated in armadillos from the State of Espírito Santo, Brazil. The ML Flow test was performed on 37 nine-banded armadillos and positive results were found in 11 (29.7%). The ML Flow test may be used to identify possible sources of Mycobaterium leprae among wild armadillos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O ML Flow e o ELISA PGL-I são testes sorológicos que detectam anticorpos IgM contra o glicolipídio fenólico I específico do Mycobacterium leprae. Para avaliar o comportamento destes testes em áreas endêmica e não endêmica para hanseníase foram estudados 351 voluntários no Brasil e no Chile, incluindo pacientes com hanseníase, controles sadios, portadores de outras doenças infecciosas, não infecciosas e dermatoses que fazem diagnóstico diferencial com hanseníase. O ponto de corte do ELISA foi estabelecido pelo método da Curva ROC (> 0,157). Em área endêmica, o ML Flow apresentou resultados positivos em 70% dos pacientes com hanseníase; o ELISA foi positivo em 53,3%. Em área não endêmica, o ML Flow foi negativo em todos os voluntários testados; o ELISA foi positivo em 4 voluntários. O ML Flow é um ensaio mais rápido, facilmente aplicável e, portanto, mais adequado para ser utilizado na Atenção Básica; o ELISA necessita, alem de uma infra-estrutura de laboratório adequada, pessoal treinado e especializado em sua execução.