993 resultados para Fetal Monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comprehensive strength monitoring system used on a fixed jacket platform is presented in this paper. The long-term monitoring of W-11-4A platform achieved. Structural responses (strain and acceleration) at selected locations, as well as associated environmental parameters, have been obtained. The emphasis of the paper is placed on the system design, and the instrumentation and operation methodology employed in the monitoring of the structural responses. The performance of the system and the characteristic results obtained during its 13-month operation are also summarized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract-This paper reports a single-crystal silicon mass sensor based on a square-plate resonant structure excited in the wine glass bulk acoustic mode at a resonant frequency of 2.065 MHz and an impressive quality factor of 4 million at 12 mtorr pressure. Mass loading on the resonator results in a linear downshift in the resonant frequency of this device, wherein the measured sensitivity is found to be 175 Hz cm2/μg. The silicon resonator is embedded in an oscillator feedback loop, which has a short-term frequency stability of 3 mHz (approximately 1.5 ppb) at an operating pressure of 3.2 mtorr, corresponding to an equivalent mass noise floor of 17 pg/cm2. Possible applications of this device include thin film monitoring and gas sensing, with the potential added benefits of scalability and integration with CMOS technology. © 2008 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evaluation of mechanical properties of carbon nanotube (CNT) fibers is inherently difficult. Here, Raman scattering-a generic methodology independent of mechanical measurements-is used to determine the interbundle strength and microscopic failure process for various CNT macroarchitectures. Raman data are used to predict the moduli of CNT films and fibers, and to illustrate the influences of the twisting geometries on the fibers' mechanical performances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumen: Este estudio presenta la estructura factorial y la evaluación de la fiabilidad de una versión en castellano de la escala Fetal Health Locus of Control, que evalúa creencias de control vinculadas a la salud del feto basándose en el concepto Locus de Control acuñado por Rotter. La escala fue administrada a mujeres en edad reproductiva (N = 130) en instituciones educativas de la ciudad de Santa Fe. La versión adaptada de la escala muestra una estructura de 3 factores principales que se corresponden con los constructos teóricos en los que se basa la escala original. La consistencia interna evaluada a través del alpha de Cronbach resultó adecuada, con valores de .81 para la subescala FHLCE-D, .75 para la subescala FHLCI y .76 para la subescala FHLCE-P. En conclusión, la versión adaptada de la escala posee propiedades psicométricas satisfactorias, similares a las de escala original.