944 resultados para FUEL RODS
Resumo:
Synopsis: Bonded-in rod timber joints off er several advantages over conventional types of joint, including high local force transfer, very stiff connections, and improved ?re and aesthetic properties since the connection is completely hidden in the insulating timber members. More recently, the use of ?bre reinforced polymer (FRP) as a connecting rod, alternative to steel rods, in bonded-in rod connections for timber structures has been investigated. However, the investigation into the behaviour of such joints is limited, in particular, connections involving basalt ?bre reinforced polymers (BFRP) bars - which is the primary focus of this research. This paper presents an experimental programme conducted to investigate the behaviour of bonded-in BFRP bars loaded parallel to the grain of glulam members. Tensile pull-out tests were conducted to examine the effect of bonded length and bond stress-slip on the structural capacity of the connection. An analytical design expression for predicting pull-out capacity is proposed and the results have been compared with some established design equations. It was found that pull-out load increased approximately linearly with the bonded length, up to maximum which occurred at a bonded length of 15 times the hole diameter, and did not increase beyond this bonded length. The most signi?cant failure modes were failure at the timber/adhesive interface followed by pullout of the BFRP rod. Increased bonded lengths resulted in higher bond slip values compared to lower equivalent bonded lengths. The proposed design model gave the best predictions of pull-out capacity compared with other existing models.
Resumo:
The behaviour of Basalt Fibre Reinforced Polymer (BFRP) loaded perpendicular to glulam timber elements was investigated. It was found that pull-out load increased approximately linearly with the bonded length up to maximum which occurred at a bonded length of 250 mm (~15 times the hole diameter) and did not increase beyond this bonded length. Failure mode of the samples was mostly shear fracture which was located at the cylindrical zone at the timber/adhesive interface. Increased bonded lengths resulted in corresponding decrease in interfacial bond stress. At 250 mm bonded length, the pull-out capacity of the proposed design model was about 2% lower than that of the tests. The results also showed that the bond stress of the theoretical model (at the ascending and descending branches) of the stress–slip curve was approximately 5–10% of that of the experiment.
Resumo:
To maintain its relevance, motorsport cannot be exempt from
the trend of increasing fuel economy. This bears obvious
competitive benefits as well, either in decreasing the
frequency of pit stops or the mass of fuel carried. Given the
increased points weighting of fuel economy for the Formula
Student (FS) competition, a complete analysis was performed
on the Queen's Formula Racing 600cc motorcycle engine in
preparation for the 2011 competition.
The criteria for such high performance fuel economy differ to
a degree from most mass transportation counterparts and were
divided into three distinct regimes; full load, part load and no
load conditions.
Full load positions naturally demand maximum torque for
performance but that does not imply that fuel savings cannot
be made whilst preserving this. The point at which maximum
torque is produced with minimum air -fuel ratio, Leanest
mixture for Best Torque (LBT), was therefore sought and
mapped for full load.
At part load, torque is less of a concern, and maintaining a
sustainable engine temperature and transient response become
more important. With decreasing AFR, engine temperatures
can rise dramatically so temperatures were measured close to
the exhaust port for a wide range of air-fuel ratios.
Competition track data was analysed to highlight key part load
operating regions and these were mapped according to
measured safe temperature limits. Torque response to a step
throttle change was also measured to ensure suitable engine
transient performance was maintained.
At no load conditions, with low engine speed only idle
conditions need to be satisfied. In the situation where the
engine is still at high speed without load, the engine is being
motored and no fuel is required. An overrun fuel cut was
employed to reflect this giving significant fuel savings. The
effect on torque and engine pickup was measured.
Modifications were also made to the fuel injector location to
improve fuel mixing and evaporation at this lower air flow
condition.
These mapping regimes were implemented and tested using
fully transient lap simulations using competition track data
and a four quadrant AC engine dynamometer. The experiment
indicated a reduction in fuel consumption for 22 laps of the FS
track from 5.08litres to 3.67litres, around 27% in total. The
actual fuel used at the 2011 competition was 3.6 litres while
placing 8th in the endurance event, further validating the
benefits of these mapping regimes.