852 resultados para FRACTURE FIXATION
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Objectives: The objective of the present study was to evaluate a prefabricated intraradicular threaded pure titanium post, designed and developed at the Sao Jose dos Campos School of Dentistry - UNESP, Brazil. This new post was designed to minimize stresses observed with prefabricated post systems and to improve cost-benefits. Materials and and methods: Fracture resistance testing of the post/core/root complex, fracture analysis by microscopy and stress analysis by the finite element method were used for post evaluation. The following four prefabricated metal post systems were analyzed: group 1, experimental post; group 2, modification of the experimental post; group 3, Flexi Post, and group 4, Para Post. For the analysis of fracture resistance, 40 bovine teeth were randomly assigned to the four groups (n=10) and used for the fabrication of test specimens simulating the situation in the mouth. The test specimens were subjected to compressive strength testing until fracture in an EMIC universal testing machine. After fracture of the test specimens, their roots were sectioned and analyzed by microscopy. For the finite element method, specimens of the fracture resistance test were simulated by computer modeling to determine the stress distribution pattern in the post systems studied. Results: The fracture test presented the following averages and standard deviation: G1 (45.63 +/- 8.77), G2 (49.98 +/- 7.08), G3 (43.84 +/- 5.52), G4 (47.61 +/- 7.23). Stress was homogenously distributed along the body of the intraradicular post in group 1, whereas high stress concentrations in certain regions were observed in the other groups. These stress concentrations in the body of the post induced the same stress concentration in root dentin. Conclusions: The experimental post (original and modified versions) presented similar fracture resistance and better results in the stress analysis when compared with the commercial post systems tested (08/2008PA/CEP).
Resumo:
OBJETIVO: Investigar a influência de Proteínas Morfogenéticas Ósseas de origem bovina (bBMPs) ligadas a hidroxiapatita mais colágeno na consolidação de fraturas instáveis do rádio. MÉTODOS: em 15 coelhos com aproximadamente 5,5 meses de idade e peso médio de 3,5kg foi realizada uma fratura transversa na porção média da diáfise do rádio de ambos os membros. Na fratura do rádio direito foi aplicada mistura de bBMPs ligadas à hidroxiapatita (bBMP-HA) e colágeno bovino como aglutinante e na do rádio esquerdo, considerada controle, nenhum tratamento foi usado. Os coelhos (cinco por período) foram submetidos à eutanásia aos 30, 60 e 90 dias após a cirurgia para realização do processamento histológico e análise microscópica. RESULTADOS: A análise histológica descritiva revelou que a consolidação foi similar para os membros tratado e controle. Pela análise histomorfométrica, a área de novo osso foi em média 867442,16 mm², 938743.00 mm² e 779621,06 mm² para os membros controles e 841118,47 mm², 788038,76mm² e 618587,24 mm² para os membros tratados, aos 30, 60 e 90 dias, respectivamente. Desta forma, aos 60 dias de pós-operatório a área de novo osso foi 12.17% maior no membro tratado com bBMP-HA/colágeno em relação ao membro controle (p<0.05, teste de Tukey). em ambos os membros a área de novo osso aumentou durante o período experimental até a total consolidação da fratura. CONCLUSÃO: Baseado nos resultados obtidos foi possível concluir que a mistura de bBMP-HA/colágeno induziu pequena, porém significante melhora na consolidação da fratura.
Resumo:
O trauma do seio frontal não é raro, correspondendo a 8% das fraturas faciais. Pode afetar a lâmina anterior e/ou posterior, com ou sem envolvimento do ducto nasofrontal. Tem alto potencial para complicações e seu manejo ainda é controvertido em algumas situações. OBJETIVO: Apresentar a epidemiologia, o diagnóstico e tratamento clínico e cirúrgico de 24 pacientes com fratura do seio frontal. MATERIAL E MÉTODOS: Estudo retrospectivo, não randomizado, de 24 pacientes com fratura de seio frontal operados no Hospital das Clínicas da Faculdade de Medicina de Botucatu, São Paulo, Brasil. RESULTADOS: Dos 24 pacientes, 16 tinham fraturas da lâmina externa e 8, da lâmina interna e externa. em 2 casos havia lesão do ducto nasofrontal. Vinte (83,4%) pacientes tiveram fraturas faciais associadas e em 13 (54,2%) foram observadas complicações intracranianas. A incisão em asa de borboleta, abaixo da sobrancelha, foi empregada na maioria dos casos cirúrgicos com bom resultado estético. Fixação dos fragmentos ósseos com diferentes materiais (fio de aço, mononylon, miniplacas de titânio) e, se necessário, reconstrução da tábua anterior com material aloplástico ou osso parietal. CONCLUSÃO: A causa principal das fraturas do seio frontal é acidente com veículos. O tratamento depende de sua complexidade, pois comumente há lesões cranioencefálicas associadas. As técnicas cirúrgicas utilizadas são as incisões, retalho bicoronal ou na sobrancelha, infra-orbital (em asa de borboleta), associadas à cirurgia endoscópica em casos de infecção fístula liquórica e complicações orbitárias.
Resumo:
Avaliamos 21 pacientes, sendo 16 pacientes do sexo masculino e 5 do feminino, com idade média de 30 anos, foram submetidos à tratamento cirúrgico da fratura-avulsão do LCP. em 57% dos casos a lesão foi secundária a acidente motociclístico e 19% a acidente automobilístico. em 72% dos casos foi identificada uma lesão na face anterior do joelho. O tratamento cirúrgico consistiu na abordagem posterior do joelho e fixação do fragmento ósseo com parafuso e arruela em 18 casos; e amarrilhas trans-ósseas em 3 casos, onde o fragmento ósseo era muito pequeno. em 91% dos casos, a cirurgia foi realizada dentro dos primeiros 15 dias apos a lesão. Os pacientes foram avaliados objetivamente (teste de gaveta posterior) e subjetivamente (Escala de Lysholm), apos um seguimento pós-operatório mínimo de 12 meses. A análise estatística não mostrou diferença significativa, ao nível de 5%, entre as avaliações objetiva e subjetiva. A ausência de lesão ligamentar periférica pode ter contribuído para que os resultados clínicos pós-operatórios tenham avaliação subjetiva satisfatória; entretanto, a presença de uma posteriorização tibial residual sugere que a fratura-avulsão do ligamento cruzado posterior deve ser abordada não como uma lesão óssea pura, mas sim, como uma lesão ósteo-ligamentar.
Resumo:
This work presents a methodology for elastic-plastic fracture reliability analysis of plane and axisymmetric structures. The structural reliability analysis is accomplished by means of the FORM analytical method. The virtual crack extension technique based on a direct minimization of potencial energy is utililized for the calculation of the energy release rate. Results are presented to illustrate the performance of the adopted methodology.
Resumo:
Aim To evaluate, using an experimental immature tooth model, the fracture resistance of bovine incisors submitted to different reinforcement treatments with mineral trioxide aggregate (MTA).Methodology An immature tooth model was created by sectioning the coronal and apical portions of 40 bovine incisors 8 mm above and 12 mm below the cementoenamel junction. The root canals were irrigated with 1.0% sodium hypochlorite. They were enlarged both coronally and apically using number 703 carbide burs (ISO: 500-104-168-007-021) and their internal diameter was standardized to 2.1 mm. The specimens were assigned to four groups (n = 10): GI-control (without filling); GII-apical MTA plug + filling with gutta-percha and endodontic sealer; GIII-filling with MTA; GIV-apical MTA plug + filling with MTA + metallic post (Reforpost I). A polyether impression material was used to simulate the periodontal ligament. The specimens were submitted to a compressive load at a crosshead speed of 0.5 mm min(-1) in a servo-hydraulic universal testing machine (MTS 810) applied at 45 degrees to the long axis of the tooth until failure. Data were submitted to statistical analysis by the Kruskal-Wallis test at 5% significance level.Results GIV presented the highest fracture resistance (32.7N) and differed significantly from the other groups (P < 0.05). No statistically difference was found between GII (16.6N) and GIII (23.4N) (P > 0.05). GIII had a significantly higher fracture resistance than GI (P < 0.05).Conclusions the use of MTA + metallic post as an intra-radicular reinforcement treatment increased the resistance to fracture of weakened bovine teeth in an experimental immature tooth model.
Resumo:
Radicular fractures in permanent teeth are uncommon injuries among dental traumas, comprising 0.5-7% of the cases. Fracture occurs most often in the middle-third of the root and rarely at the apical-third. The present paper reports a clinical case of a horizontal radicular fracture located between the middle- and apical-third of a upper left-central incisor followed-up for over 3 years. The tooth was extracted owing to periodontal reasons. Histomorphologically, it showed pulp-vitality preservation and root healing by hard-tissue deposition.
Resumo:
Despite its high success rate, therapy with osseointegrated dental implants is not free of complications. Among the problems that may occur is fracture of implants, which, albeit a rare phenomenon, may lead to unpleasant clinical outcomes for the patient, as well as for the clinician. Thus, it is paramount to know the factors related to the biological processes involved in maintenance of osseointegration and biomechanics applied to dental implants to prevent such complications, as well as treatment options available to deal with the problem. Therefore, the objectives of this work were to investigate the literature to identify causative factors that may lead to fracture of dental implants and to discuss available procedures.
Resumo:
A Brazilian orthopaedic company designed a stainless steel plate called Synthesis Pengo System (S.P.S.), which has one fixed and one changeable extremity. According to the assembly of the changeable extremity, it is possible to obtain dynamization or neutralization of the fracture site. Since the S.P.S. plate was developed for use in human patients, the aim of this study was to evaluate this system in long-bone diaphyseal fractures in dogs. Eight dogs with closed diaphyseal fractures of the femur (n = 1), radius and ulna (n = 5), and tibia (n = 2) were used. Patients were aged seven months to three years and weighed 18 to 31.2 kg. The S.P.S. plate was assembled with one fixed extremity and one changeable extremity in dynamization mode. The trail bar was positioned for synthesis modules with holes for cortical screws. The modules were positioned close to one another in two fractures and for away from the fracture site in the others. The bone healing occurred by external callus. Since motion at the fracture site determines the amount of callus required, the secondary bone healing that was observed in all of the cases indicated less rigid fixation of this system. A potential benefit of this system was a lesser interface contact with the bone since it was only done by trail bar. The major disadvantage was the prominence of the implant. It was possible to conclude that the S.P.S. plate appears to be a suitable method for the treatment of diaphyseal fractures in dogs.
Resumo:
We have investigated if a new LEDs system has enough efficient energy to promote efficient shear and tensile bonding strength resistance under standardized tests. LEDs 470 +/- 10 nm can be used to photocure composite during bracket fixation. Advantages considering resistance to tensile and shear bonding strength when these systems were used are necessary to justify their clinical use. Forty eight human extracted premolars teeth and two light sources were selected, one halogen lamp and a LEDs system. Brackets for premolar were bonded through composite resin. Samples were submitted to standardized tests. A comparison between used sources under shear bonding strength test, obtained similar results; however, tensile bonding test showed distinct results: a statistical difference at a level of 1% between exposure times (40 and 60 seconds) and even to an interaction between light source and exposure time. The best result was obtained with halogen lamp use by 60 seconds, even during re-bonding; however LEDs system can be used for bonding and re-bonding brackets if power density could be increased.