869 resultados para Error correction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free induction decay (FID) navigators were found to qualitatively detect rigid-body head movements, yet it is unknown to what extent they can provide quantitative motion estimates. Here, we acquired FID navigators at different sampling rates and simultaneously measured head movements using a highly accurate optical motion tracking system. This strategy allowed us to estimate the accuracy and precision of FID navigators for quantification of rigid-body head movements. Five subjects were scanned with a 32-channel head coil array on a clinical 3T MR scanner during several resting and guided head movement periods. For each subject we trained a linear regression model based on FID navigator and optical motion tracking signals. FID-based motion model accuracy and precision was evaluated using cross-validation. FID-based prediction of rigid-body head motion was found to be with a mean translational and rotational error of 0.14±0.21 mm and 0.08±0.13(°) , respectively. Robust model training with sub-millimeter and sub-degree accuracy could be achieved using 100 data points with motion magnitudes of ±2 mm and ±1(°) for translation and rotation. The obtained linear models appeared to be subject-specific as inter-subject application of a "universal" FID-based motion model resulted in poor prediction accuracy. The results show that substantial rigid-body motion information is encoded in FID navigator signal time courses. Although, the applied method currently requires the simultaneous acquisition of FID signals and optical tracking data, the findings suggest that multi-channel FID navigators have a potential to complement existing tracking technologies for accurate rigid-body motion detection and correction in MRI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study evaluates the performance of four methods for estimating regression coefficients used to make statistical decisions regarding intervention effectiveness in single-case designs. Ordinary least squares estimation is compared to two correction techniques dealing with general trend and one eliminating autocorrelation whenever it is present. Type I error rates and statistical power are studied for experimental conditions defined by the presence or absence of treatment effect (change in level or in slope), general trend, and serial dependence. The results show that empirical Type I error rates do not approximate the nominal ones in presence of autocorrelation or general trend when ordinary and generalized least squares are applied. The techniques controlling trend show lower false alarm rates, but prove to be insufficiently sensitive to existing treatment effects. Consequently, the use of the statistical significance of the regression coefficients for detecting treatment effects is not recommended for short data series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis studies evaluation of software development practices through an error analysis. The work presents software development process, software testing, software errors, error classification and software process improvement methods. The practical part of the work presents results from the error analysis of one software process. It also gives improvement ideas for the project. It was noticed that the classification of the error data was inadequate in the project. Because of this it was impossible to use the error data effectively. With the error analysis we were able to show that there were deficiencies in design and analyzing phases, implementation phase and in testing phase. The work gives ideas for improving error classification and for software development practices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En el sector suroriental de la Cuenca del Ebro, la inclinación paleomagnética obtenida en las sucesiones aluviales oligocenas es considerablemente menor que la esperable, si se considera la paleolatitud de referencia calculada para esa región durante el Oligoceno. Este error de inclinación puede deberse a diversos factores, como el control hidrodinámica de las partículas magnéticas en el medio deposicional, la compactación diferencial del sedimento durante el enterramiento, o bien a la deformación tectónica. Este trabajo se ha centrado en su estudio en dos sucesiones dominantemente aluviales, donde previamente se había establecido su magnetoestratigrafia. Las litofacies aluviales y lacustres estudiadas se han agrupado en cinco grupos: areniscas grises, areniscas rojas y versicolores, limos rojos, lutitas rojas y calizas. Se ha demostrado la existencia de una correlación entre la abundancia de filosilicatos y el error de inclinación. De esta manera, las litofacies con un bajo porcentaje de filosilicatos (calizas y areniscas grises) presentan errores de unos 5', estadisticarnente no significativos, con respecto a la inclinación de referencia. Por el contrario, en materiales con un porcentaje más elevado de filosilicatos (limos y arcillas) el error puede llegar a los 25'. Este hecho no tiene repercusión en la interpretación de las polaridades magnéticas, pero si en las reconstmcciones palinspásticas y paleogeográficas basadas en los cálculos de paleolatitudes a partir de las paleoinclinaciones. Los resultados obtenidos demuestran la necesidad de cautela en la propuesta de conclusiones basadas exclusivamente en este tipo de información.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study used event-related brain potentials to investigate whether math anxiety is related to abnormal error monitoring processing. Seventeen high math-anxious (HMA) and seventeen low math-anxious (LMA) individuals were presented with a numerical and a classical Stroop task. Groups did not differ in terms of trait or state anxiety. We found enhanced error-related negativity (ERN) in the HMA group when subjects committed an error on the numerical Stroop task, but not on the classical Stroop task. Groups did not differ in terms of the correct-related negativity component (CRN), the error positivity component (Pe), classical behavioral measures or post-error measures. The amplitude of the ERN was negatively related to participants" math anxiety scores, showing a more negative amplitude as the score increased. Moreover, using standardized low resolution electromagnetic tomography (sLORETA) we found greater activation of the insula in errors on a numerical task as compared to errors in a nonnumerical task only for the HMA group. The results were interpreted according to the motivational significance theory of the ERN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For a massless fluid (density = 0), the steady flow along a duct is governed exclusively by viscous losses. In this paper, we show that the velocity profile obtained in this limit can be used to calculate the pressure drop up to the first order in density. This method has been applied to the particular case of a duct, defined by two plane-parallel discs. For this case, the first-order approximation results in a simple analytical solution which has been favorably checked against numerical simulations. Finally, an experiment has been carried out with water flowing between the discs. The experimental results show good agreement with the approximate solution

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we propose a method for prospective motion correction in MRI using a novel image navigator module, which is triggered by a free induction decay (FID) navigator. Only when motion occurs, the image navigator is run and new positional information is obtained through image registration. The image navigator was specifically designed to match the impact on the magnetization and the acoustic noise of the host sequence. This detection-correction scheme was implemented for an MP-RAGE sequence and 5 healthy volunteers were scanned at 3T while performing various head movements. The correction performance was demonstrated through automated brain segmentation and an image quality index whose results are sensitive to motion artifacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Connectivity analysis on diffusion MRI data of the whole- brain suffers from distortions caused by the standard echo- planar imaging acquisition strategies. These images show characteristic geometrical deformations and signal destruction that are an important drawback limiting the success of tractography algorithms. Several retrospective correction techniques are readily available. In this work, we use a digital phantom designed for the evaluation of connectivity pipelines. We subject the phantom to a âeurooetheoretically correctâeuro and plausible deformation that resembles the artifact under investigation. We correct data back, with three standard methodologies (namely fieldmap-based, reversed encoding-based, and registration- based). Finally, we rank the methods based on their geometrical accuracy, the dropout compensation, and their impact on the resulting connectivity matrices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adjusting behavior following the detection of inappropriate actions allows flexible adaptation to task demands and environmental contingencies during goal-directed behaviors. Post-error behavioral adjustments typically consist in adopting more cautious response mode, which manifests as a slowing down of response speed. Although converging evidence involves the dorsolateral prefrontal cortex (DLPFC) in post-error behavioral adjustment, whether and when the left or right DLPFC is critical for post-error slowing (PES), as well as the underlying brain mechanisms, remain highly debated. To resolve these issues, we used single-pulse transcranial magnetic stimulation in healthy human adults to disrupt the left or right DLPFC selectively at various delays within the 30-180ms interval following false alarms commission, while participants preformed a standard visual Go/NoGo task. PES significantly increased after TMS disruption of the right, but not the left DLPFC at 150ms post-FA response. We discuss these results in terms of an involvement of the right DLPFC in reducing the detrimental effects of error detection on subsequent behavioral performance, as opposed to implementing adaptative error-induced slowing down of response speed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los análisis de Fourier permiten caracterizar el contorno del diente y obtener una serie de parámetros para un posterior análisis multivariante. Sin embargo, la gran complejidad que presentan algunas formas obliga a determinar el error de medición intrínseco que se produce. El objetivo de este trabajo es aplicar y validar los análisis de Fourier en el estudio de la forma dental del segundo molar inferior (M2) de cuatro especies de primates Hominoidea para explorar la variabilidad morfométrica interespecífica, así como determinar el error de medición a un nivel intra e interobservador. El contorno de la superficie oclusal del diente fue definido digitalmente y con las funciones derivadas del análisis de Fourier se realizaron Análisis Discriminantes y Test de Mantel (correlaciones de Pearson) para determinar las diferencias de forma a partir de las mediciones tomadas. Los resultados indican que el análisis de Fourier muestra la variabilidad de forma en dientes molares en especies de primates Hominoidea. Adicionalmente, los altos niveles de correlación a nivel intra (r>0,9) como interobservador (r>0,7) sugieren que la descripción morfométrica del diente a partir de métodos de Fourier realizados por diferentes observadores puede ser agrupada para posteriores análisis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance standards for Positron emission tomography (PET) were developed to be able to compare systems from different generations and manufacturers. This resulted in the NEMA methodology in North America and the IEC in Europe. In practices, the NEMA NU 2- 2001 is the method of choice today. These standardized methods allow assessment of the physical performance of new commercial dedicated PET/CT tomographs. The point spread in image formation is one of the factors that blur the image. The phenomenon is often called the partial volume effect. Several methods for correcting for partial volume are under research but no real agreement exists on how to solve it. The influence of the effect varies in different clinical settings and it is likely that new methods are needed to solve this problem. Most of the clinical PET work is done in the field of oncology. The whole body PET combined with a CT is the standard investigation today in oncology. Despite the progress in PET imaging technique visualization, especially quantification of small lesions is a challenge. In addition to partial volume, the movement of the object is a significant source of error. The main causes of movement are respiratory and cardiac motions. Most of the new commercial scanners are in addition to cardiac gating, also capable of respiratory gating and this technique has been used in patients with cancer of the thoracic region and patients being studied for the planning of radiation therapy. For routine cardiac applications such as assessment of viability and perfusion only cardiac gating has been used. However, the new targets such as plaque or molecular imaging of new therapies require better control of the cardiac motion also caused by respiratory motion. To overcome these problems in cardiac work, a dual gating approach has been proposed. In this study we investigated the physical performance of a new whole body PET/CT scanner with NEMA standard, compared methods for partial volume correction in PET studies of the brain and developed and tested a new robust method for dual cardiac-respiratory gated PET with phantom, animal and human data. Results from performance measurements showed the feasibility of the new scanner design in 2D and 3D whole body studies. Partial volume was corrected, but there is no best method among those tested as the correction also depends on the radiotracer and its distribution. New methods need to be developed for proper correction. The dual gating algorithm generated is shown to handle dual-gated data, preserving quantification and clearly eliminating the majority of contraction and respiration movement

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last decades, calibration techniques have been widely used to improve the accuracy of robots and machine tools since they only involve software modification instead of changing the design and manufacture of the hardware. Traditionally, there are four steps are required for a calibration, i.e. error modeling, measurement, parameter identification and compensation. The objective of this thesis is to propose a method for the kinematics analysis and error modeling of a newly developed hybrid redundant robot IWR (Intersector Welding Robot), which possesses ten degrees of freedom (DOF) where 6-DOF in parallel and additional 4-DOF in serial. In this article, the problem of kinematics modeling and error modeling of the proposed IWR robot are discussed. Based on the vector arithmetic method, the kinematics model and the sensitivity model of the end-effector subject to the structure parameters is derived and analyzed. The relations between the pose (position and orientation) accuracy and manufacturing tolerances, actuation errors, and connection errors are formulated. Computer simulation is performed to examine the validity and effectiveness of the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cada cert temps hi ha assumptes d’alt interès social dins de la jurisdicció. En els últims anys, coincidint amb la crisi financera internacional, els assumptes relatius a contractes bancaris complexos, sobretot permutes financeres o swaps, han tingut una gran rellevància. En un context de crisi financera internacional, i també nacional, s'han estès el nombre de demandes dirigides contra bancs i entitats financeres. Són reclamacions en les quals se sol·licita la declaració de nul·litat dels citats contractes, principalment es basa en un error del consentiment, nul·litat que comporta la devolució de les quantitats invertides, de les rentabilitats esperades o de les penalitzacions aplicades davant la resolució anticipada d'us contractes pels clients defraudats en les seves expectatives. Les presents pàgines pretenen un estudi dels litigis sobre SWAPS, principalment dels “Interest Rate Swap”, identificar quins són els contractes bancaris complexes, quines són les normes de consentiment contractual que els regeixen. Respecte dels primers, cal destacar que l'elevat nombre de casos plantejats davant els nostres tribunals no es tradueix en una casuística tan àmplia com seria imaginable. La gran majoria versa sobre les peticions de nul·litat del contracte (total o parcial) realitzades pels clients, al moment en què l'Euribor va descendir, i que allò que molts havien contractat com un segur de cobertura enfront dels elevats tipus d'interès que havien de pagar per les seves hipoteques, veien com conforme als pactes en el contracte, havien de satisfer al seu contrapart (una entitat de crèdit) una liquidació.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Nucleus accumbens (Nacc) has been proposed to act as a limbic-motor interface. Here, using invasive intraoperative recordings in an awake patient suffering from obsessive-compulsive disease (OCD), we demonstrate that its activity is modulated by the quality of performance of the subject in a choice reaction time task designed to tap action monitoring processes. Action monitoring, that is, error detection and correction, is thought to be supported by a system involving the dopaminergic midbrain, the basal ganglia, and the medial prefrontal cortex. In surface electrophysiological recordings, action monitoring is indexed by an error-related negativity (ERN) appearing time-locked to the erroneous responses and emanating from the medial frontal cortex. In preoperative scalp recordings the patient's ERN was found to be signifi cantly increased compared to a large (n = 83) normal sample, suggesting enhanced action monitoring processes. Intraoperatively, error-related modulations were obtained from the Nacc but not from a site 5 mm above. Importantly, crosscorrelation analysis showed that error-related activity in the Nacc preceded surface activity by 40 ms. We propose that the Nacc is involved in action monitoring, possibly by using error signals from the dopaminergic midbrain to adjust the relative impact of limbic and prefrontal inputs on frontal control systems in order to optimize goal-directed behavior.