996 resultados para Elevated T-maze test
Resumo:
Chlorophyll fluorescence measurements have a wide range of applications from basic understanding of photosynthesis functioning to plant environmental stress responses and direct assessments of plant health. The measured signal is the fluorescence intensity (expressed in relative units) and the most meaningful data are derived from the time dependent increase in fluorescence intensity achieved upon application of continuous bright light to a previously dark adapted sample. The fluorescence response changes over time and is termed the Kautsky curve or chlorophyll fluorescence transient. Recently, Strasser and Strasser (1995) formulated a group of fluorescence parameters, called the JIP-test, that quantify the stepwise flow of energy through Photosystem II, using input data from the fluorescence transient. The purpose of this study was to establish relationships between the biochemical reactions occurring in PS II and specific JIP-test parameters. This was approached using isolated systems that facilitated the addition of modifying agents, a PS II electron transport inhibitor, an electron acceptor and an uncoupler, whose effects on PS II activity are well documented in the literature. The alteration to PS II activity caused by each of these compounds could then be monitored through the JIP-test parameters and compared and contrasted with the literature. The known alteration in PS II activity of Chenopodium album atrazine resistant and sensitive biotypes was also used to gauge the effectiveness and sensitivity of the JIP-test. The information gained from the in vitro study was successfully applied to an in situ study. This is the first in a series of four papers. It shows that the trapping parameters of the JIP-test were most affected by illumination and that the reduction in trapping had a run-on effect to inhibit electron transport. When irradiance exposure proceeded to photoinhibition, the electron transport probability parameter was greatly reduced and dissipation significantly increased. These results illustrate the advantage of monitoring a number of fluorescence parameters over the use of just one, which is often the case when the F-V/F-M ratio is used.
Resumo:
Cytokines are important for breast cell function, both as trophic hormones and as mediators of host defense mechanisms against breast cancer. Recently, inducible feedback suppressors of cytokine signalling (SOCS/JAB/SSI) have been identified, which decrease cell sensitivity to cytokines. We examined the expression of SOCS genes in 17 breast carcinomas and 10 breast cancer lines, in comparison with normal tissue and breast lines. We report elevated expression of SOCS-1-3 and CIS immunoreactive proteins within in situ ductal carcinomas and infiltrating ductal carcinomas relative to normal breast tissue. Significantly increased expression of SOCS-1-3 and CIS transcripts was also shown by quantitative in situ hybridisation within both tumour tissue and reactive stroma. CIS transcript expression was elevated in all 10 cancer lines, but not in control lines. However, there was no consistent elevation of other SOCS transcripts. CIS protein was shown by immunoblot to be present in all cancer lines at increased levels, mainly as the 47 kDa ubiquitinylated form. A potential proliferative role for CIS overexpression is supported by reports that CIS activates ERK kinases, and by strong induction in transient reporter assays with an ERK-responsive promoter. The in vivo elevation of SOCS gene expression may be part of the host/tumour response or a response to autocrine/paracrine GH and prolactin. However, increased CIS expression in breast cancer lines appears to be a specific lesion, and could simultaneously shut down STAT 5 signalling by trophic hormones, confer resistance to host cytokines and increase proliferation through ERK kinases.
Resumo:
In response to recent reports of contamination of the nearshore marine environment along the Queensland coast by herbicides (including areas inside the Great Barrier Reef Marine Park), an ecotoxicological assessment was conducted of the impact of the herbicides diuron and atrazine on scleractinian corals. Pulse-amplitude modulated (PAM) chlorophyll fluorescence techniques were used to assess the herbicide effects on the symbiotic dinoflagellates within the tissues (in hospite) of 4 species of coral (Acropora formosa, Montipora digitata, Porites cylindrica, Seriatopora hystrix) in static toxicity tests, and in freshly isolated symbiotic dinoflagellates from Stylophora pistillata. Using change in the effective quantum yield (DeltaF/F-m') as an effect criterion, diuron (no observable effect concentration, NOEC = 0.3 mug 1(-1); lowest observable effect concentration, LOEC = 1 mug 1(-1); median effective concentration, EC50 4 to 6 mug 1(-1)) was found to be more toxic than atrazine (NOEC = 1 mug 1(-1), LOEC = 3 mug 1(-1), EC50 40 to 90 mug 1(-1)) in short-term (10 h) toxicity tests. In the tests with isolated algae, significant reductions in DeltaF/F-m' were recorded as low as 0.25 mug 1(-1) diuron (LOEC, EC50 = 5 mug 1(-1)). Time-course experiments indicated that the effects of diuron were rapid and reversible. At 10 mug 1(-1) diuron, DeltaF/F-m' was reduced by 25% in 20 to 30 min, and by 50% in 60 to 90 min. Recovery of DeltaF/F-m' in corals exposed to 10 mug 1(-1) diuron and then transferred to running seawater was slower, returning to within 10% of control values inside 1 to 7 h. The effect of a reduction in salinity (35 to 27%) on diuron toxicity (at 1 and 3 mug 1(-1) diuron) was tested to examine the potential consequences of contaminated coastal flood plumes inundating inshore reefs. DeltaF/F-m' was reduced in the diuron-exposed corals, but there was no significant interaction between diuron and reduced salinity seawater within the 10 h duration of the test. Exposure to higher (100 and 1000 mug 1(-1)) diuron concentrations for 96 h caused a reduction in DeltaF/F-m' the ratio variable to maximal fluorescence (F,1F.), significant loss of symbiotic dinoflagellates and pronounced tissue retraction, causing the corals to pale or bleach. The significance of the results in relation to diuron contamination of the coastal marine environment from terrestrial sources (mainly agricultural) and marine sources (antifouling paints) are discussed.
Resumo:
Using synchrotron X-ray grazing incidence diffraction, superlattice structures have been observed to develop in Langmuir-Blodgett films of cadmium arachidate as the temperature is raised. The previously reported superstructure in the stacked lamellae at room temperature changes at about 70 degreesC and there are further changes at about 90 and 103 degreesC before the major phase transition from stacked lamellae to hexagonally packed rods occurs at 107 degreesC (Langmuir 1997, 13, 1602). Between 70 and 103 degreesC there is a 1 x 10 one-dimensional in-plane superstructure, which is commensurate with the local structure and has an interlayer shift along [01] by a distance of b (of the local structure) at lower temperatures, and a further shift at about 90 degreesC. At lower (
Resumo:
This study compares the performance of the Quickscreen and Default protocols of the ILO-96 Otodynamics Analyzer in recording transient evoked otoacoustic emissions (TEOAEs) from adults using clinical decision analysis. Data were collected from 25 males (mean age = 29.0 years, SD = 6.8) and 35 females (mean age = 28.1 years, SD = 9.6). The results showed that the mean signal-to-noise ratios obtained from the Quickscreen were significantly greater than those from the Default protocol at 1,2, and 4 kHz. The comparison of the performance of the two protocols, based on the results using receiver operating characteristics curves, revealed a higher performance of the Quickscreen than the Default protocol at 1 and 4 kHz but not at 2 kHz. In view of the enhanced performance of the Quickscreen over the Default protocol in general, the routine use of the Default protocol for testing adults in audiology clinics should be reconsidered.
Resumo:
Borderline hypertension (BH) has been associated with an exaggerated blood pressure (BP) response during laboratory stressors. However, the incidence of target organ damage in this condition and its relation to BP hyperreactivity is an unsettled issue. Thus, we assessed the Doppler echocardiographic profile of a group of BH men (N = 36) according to office BP measurements with exaggerated BP in the cycloergometric test. A group of normotensive men (NT, N = 36) with a normal BP response during the cycloergometric test was used as control. To assess vascular function and reactivity, all subjects were submitted to the cold pressor test. Before Doppler echocardiography, the BP profile of all subjects was evaluated by 24-h ambulatory BP monitoring. All subjects from the NT group presented normal monitored levels of BP. In contrast, 19 subjects from the original BH group presented normal monitored BP levels and 17 presented elevated monitored BP levels. In the NT group all Doppler echocardiographic indexes were normal. All subjects from the original BH group presented normal left ventricular mass and geometrical pattern. However, in the subjects with elevated monitored BP levels, fractional shortening was greater, isovolumetric relaxation time longer, and early to late flow velocity ratio was reduced in relation to subjects from the original BH group with normal monitored BP levels (P<0.05). These subjects also presented an exaggerated BP response during the cold pressor test. These results support the notion of an integrated pattern of cardiac and vascular adaptation during the development of hypertension.
Resumo:
Foi aplicada uma versão reduzida do "Face-Hand Test", o FHT-R, em 91 pessoas com 65 anos ou mais em uma amostra ao acaso de idosos vivendo na comunidade (São Paulo, Brasil), com objetivo de testar a habilidade do instrumento em detectar as síndromes psicorgânicas. Os escores do FHT-R foram comparados com as avaliações de um psiquiatra utilizando uma entrevista semi-estruturada, a "Clinical Interview Schedule". Cinco pessoas foram consideradas como sendo portadoras de distúrbios psicorgânicos e 86 como não sendo portadoras de tais distúrbios. No ponto de corte 0/1 os coeficientes de validação obtidos foram: sensibilidade 60%, especificidade 94%, valor prognóstico positivo 38%, valor prognóstico negativo 98%, e taxa de classificação incorreta 8%. A utilização do Teste em pesquisas epidemiológicas é discutida no corpo do trabalho.
Resumo:
This paper studies the application of commercial biocides to old maritime pine timber structures (Pinus pinaster Ait.) that have previously been impregnated with other products. A method was developed in the laboratory to be used in situ to determine the impregnation depth achieved by a new generation biocide product applied to timber from an old building. This timber had once been treated with an unknown product difficult to characterize without extensive analysis. The test was initially developed in laboratory conditions and later tested on elements of the roof structure of an 18th century building. In both cases the results were promising and mutually consistent with penetration depths for some treatments reaching 2.0 cm. The application in situ proved the tests viability and simplicity of execution giving a clear indication on the feasibility of possible re-treatments.
Resumo:
When a paleomagnetic pole is sought for in an igneous body, the host rocks should be subjected to a contact test to assure that the determined paleopole has the age of the intrusion. If the contact test is positive, it precludes the possibility that the measured magnetization is a later effect. Therefore, we investigated the variations of the remanent magnetization along cross-sections of rocks hosting the Foum Zguid dyke (southern Morocco) and the dyke itself. A positive contact test was obtained, but it is mainly related with Chemical/Crystalline Remanent Magnetization due to metasomatic processes in the host-rocks during magma intrusion and cooling, and not only with Thermo-Remanent Magnetization as ordinarily assumed in standard studies. Paleomagnetic data obtained within the dyke then reflect the Earth magnetic field during emplacement of this well-dated (196.9 +/- 1.8 Ma) intrusion.
Resumo:
This paper concerns the study of biocides application in old timber structures of maritime pine (Pinus pinaster Ail.), previously impregnated with other products. A method was developed in laboratory to determine in situ the penetration depth of a product applied superficially. As initial treatment, three traditional products for sawn timber for buildings were used and, for new treatments, two newer, more environmentally benign products were used. Their ability to penetrate the pre-treated surfaces was evaluated after 1, 2 and 3 applications at 24 hours intervals and the results obtained are presented. Finally, the applicability of the developed test to the in-situ evaluation of timber structures is also discussed.
Resumo:
The aim of the study is to adapt and then discuss the appropriateness of the Life Orientation Test as a one or two dimension scale. The research includes two studies; one is composed of a sequential sample of 280 people with multiple sclerosis, 71% female, and another includes a convenience sample of 615 individuals from the community, 51.1% female. Because the construct is built upon a theoretical assumption that has one dimension, we examine the hypothesis of one or two factor solutions through confirmatory factor analysis, and the two-dimension solution premise demonstrates better adjustment for both samples. The other psychometric properties explored show appropriate results for the Portuguese sample, and similar to the original ones; the Test therefore seems appropriate for use in cross cultural studies. Based on our results, we discuss whether the questionnaire is a one or two dimension instrument, concluding that it appears appropriate to accept the recommendations of the original authors to use it as a one-dimensional tool and, when necessary, to use both dimensions. - RESUMO: El objetivo del estudio es adaptar y discutir la adecuación de la prueba de Orientación de la Vida en una o dos escalas de dimensión. La investigación engloba dos estudios, uno constituido por una muestra secuencial de 280 personas con esclerosis múltiple, 71% mujeres y otro con una muestra de conveniencia de la comunidad de 615 individuos, 51,1% del sexo femenino. Como el constructo se asienta sobre la presunción teórica de que tiene una dimensión, inspeccionamos la hipótesis de una o dos soluciones de factor a través del análisis factorial confirmatorio y la hipótesis de dos dimensiones manifiesta un mejor ajuste para ambas muestras. Las otras propiedades psicométricas exploradas muestran los resultados apropiados para la muestra portuguesa, y semejantes a los originales. Parece apropiado para los estudios culturales transversales. Basándonos en nuestros resultados, discutimos si el cuestionario es un instrumento de una o dos dimensiones, concluyéndose que parece conveniente seguir las recomendaciones de los autores originales, para utilizarlo como un instrumento unidimensional y, si fuera necesario necesario, utilizar cada una de las dimensiones.
Resumo:
The study was carried out to evaluate the diagnostic performance of the ICT malaria Pf/PvTM test for vivax malaria diagnosis in Belém, Amazon region, Brazil. The results of blood malaria parasites examination using an immunochromatography test were compared with thick blood film (TBF) examination. It was also evaluated the performance of this test storaged at three different temperatures (25°C, 30°C, and 37°C) for 24 hours before use. Overall sensitivity of ICT Pf/PvTM was 61.8% with a specificity of 100%, positive and negative predictive value of 100% and 71.8%, respectively and accuracy of 80.6%. The test sensitivity was independent of the parasite density. This test needs to be further reviewed in order to have better performance for P. vivax malaria diagnosis.
Resumo:
A test chamber was projected and built (according to ISO 16000-9 Standard) to simulate atmospheric conditions experienced by rubber infill (when applied in synthetic turf pitches) and measure accurately the airborne emissions of pollutants such as dusts and volatile organic compounds (VOC), as well as pollutants present in leachates. It should be pointed out that standard ISO 16000-9 is only concerned with the determination of the emission of VOC from building products and furnishing (not specific of synthetic turf materials), whereas other standards are concerned with the emission of leachates only. This procedure is to be considered as a technical option to the lysimeter "global turf system evaluation" when the rubber infill alone is to be evaluated. The advantage of the proposed option considering this "test chamber" is its simplicity and economy. This test chamber is actually installed and being used for tests in LAIST.
Resumo:
Electric vehicles introduction will affect cities environment and urban mobility policies. Network system operators will have to consider the electric vehicles in planning and operation activities due to electric vehicles’ dependency on the electricity grid. The present paper presents test cases using an Electric Vehicle Scenario Simulator (EVeSSi) being developed by the authors. The test cases include two scenarios considering a 33 bus network with up to 2000 electric vehicles in the urban area. The scenarios consider a penetration of 10% of electric vehicles (200 of 2000), 30% (600) and 100% (2000). The first scenario will evaluate network impacts and the second scenario will evaluate CO2 emissions and fuel consumption.
Resumo:
Physical function is limited post-liver transplantation and exercise training can improve exercise capacity following transplantation but previously assessment of functional capacity is necessary. The 6 minute walk test (6MWT) is routinely used for studying patient’s exercise capacity and is less expensive and time consuming than a Cardiopulmonary Exercise Test (CPXT). There have been some studies looking at the relationship between 6MWT and peak VO2 in patients but few presented an adequate equation for predicted peak VO2 from 6MWT to transplanted patients and none for Familial Amyloidotic Polyneuropathy (FAP) liver transplanted patients (FAPTx). The aim of this study was to compare the validity of 6 equations as predictors of VO2 from the 6MWT and compare it with directly measured VO2 in patients FAPTx.