854 resultados para Electronic equipment
Resumo:
OBJECTIVE: To review the available knowledge on epidemiology and diagnoses of acute infections in children aged 2 to 59 months in primary care setting and develop an electronic algorithm for the Integrated Management of Childhood Illness to reach optimal clinical outcome and rational use of medicines. METHODS: A structured literature review in Medline, Embase and the Cochrane Database of Systematic Review (CDRS) looked for available estimations of diseases prevalence in outpatients aged 2-59 months, and for available evidence on i) accuracy of clinical predictors, and ii) performance of point-of-care tests for targeted diseases. A new algorithm for the management of childhood illness (ALMANACH) was designed based on evidence retrieved and results of a study on etiologies of fever in Tanzanian children outpatients. FINDINGS: The major changes in ALMANACH compared to IMCI (2008 version) are the following: i) assessment of 10 danger signs, ii) classification of non-severe children into febrile and non-febrile illness, the latter receiving no antibiotics, iii) classification of pneumonia based on a respiratory rate threshold of 50 assessed twice for febrile children 12-59 months; iv) malaria rapid diagnostic test performed for all febrile children. In the absence of identified source of fever at the end of the assessment, v) urine dipstick performed for febrile children <2 years to consider urinary tract infection, vi) classification of 'possible typhoid' for febrile children >2 years with abdominal tenderness; and lastly vii) classification of 'likely viral infection' in case of negative results. CONCLUSION: This smartphone-run algorithm based on new evidence and two point-of-care tests should improve the quality of care of <5 year children and lead to more rational use of antimicrobials.
Resumo:
Very large molecular systems can be calculated with the so called CNDOL approximate Hamiltonians that have been developed by avoiding oversimplifications and only using a priori parameters and formulas from the simpler NDO methods. A new diagonal monoelectronic term named CNDOL/21 shows great consistency and easier SCF convergence when used together with an appropriate function for charge repulsion energies that is derived from traditional formulas. It is possible to obtain a priori molecular orbitals and electron excitation properties after the configuration interaction of single excited determinants with reliability, maintaining interpretative possibilities even being a simplified Hamiltonian. Tests with some unequivocal gas phase maxima of simple molecules (benzene, furfural, acetaldehyde, hexyl alcohol, methyl amine, 2,5 dimethyl 2,4 hexadiene, and ethyl sulfide) ratify the general quality of this approach in comparison with other methods. The calculation of large systems as porphine in gas phase and a model of the complete retinal binding pocket in rhodopsin with 622 basis functions on 280 atoms at the quantum mechanical level show reliability leading to a resulting first allowed transition in 483 nm, very similar to the known experimental value of 500 nm of "dark state." In this very important case, our model gives a central role in this excitation to a charge transfer from the neighboring Glu(-) counterion to the retinaldehyde polyene chain. Tests with gas phase maxima of some important molecules corroborate the reliability of CNDOL/2 Hamiltonians.
Resumo:
Zinc indium tin oxide (ZITO) transparent conductive oxide layers were deposited via radio frequency (RF) magnetron co-sputtering at room temperature. A series of samples with gradually varying zinc content was investigated. The samples were characterized with x-ray and ultraviolet photoemission spectroscopy (XPS, UPS) to determine the electronic structure of the surface. Valence and conduction bands maxima (VBM, CBM), and work function were determined. The experiments indicate that increasing Zn content results in films with a higher defect rate at the surface leading to the formation of a degenerately doped surface layer if the Zn content surpasses 50%. Furthermore, the experiments demonstrate that ZITO is susceptible to ultraviolet light induced work function reduction, similar to what was earlier observed on ITO and TiO2 films.
Resumo:
Postmortem imaging techniques, especially postmortem computed tomography, have become integral tools in forensic investigations. Multiphase postmortem computed tomography angiography (MPMCTA) visualizes the vascular system in detail and makes it possible to evaluate the perfusion of even the smallest vessels. Although the technique has been well described for adults, no pediatric cases have been reported and no pediatric protocol has been established for this type of investigation. We present the case a 7-year-old child for which we used a previously described MPMCTA protocol and adapted values of perfusion, with the same technical equipment as for adult cases. Our main objective was to propose a perfusion protocol adapted for the investigation of infants and children. Moreover, we discuss both the difficulties that we encountered and possible ways to further improve the investigation of pediatric cases by MPMCTA.
Resumo:
PURPOSE: A surgical gastrostomy is mandatory in cases where a PEG is not feasible. Various minimally invasive techniques have been described, but many involve unusable materials in small children and/or have risk of disunion. We describe a technique for true Stamm gastrostomy performed by laparoscopy (LSG) with a purse string suture and four points of attachment onto the wall. METHOD: We reviewed 20 children who underwent an LSG from 2010 to 2013. After incision of the skin at the location planned for the gastrostomy, using three 3-5mm ports the stomach is fixed to the wall by three suspension stitches, which are entered and then emerged subcutaneously. A fourth stitch of attachment is used to make an award on the stomach and tie around the gastrostomy tube. RESULTS: Mean age was 4.2years, with 70% aged <2years. All children were malnourished, most often severely. All but two underwent a concomitant fundoplication. Feeding through the gastrostomy started on D0 or D1. Total feeding by gastrostomy was achieved in a mean duration of 2.9day. Mean hospital stay was 4.5days. There was no perioperative complication. Mean follow-up was 14months. Once, the balloon was accidently deflated and reinflated in the wall leading to its necrosis. Five peristomial granulomas were noticed. It was always possible to replace the tube by a gastrostomy device at least 6weeks after surgery. CONCLUSION: This new technique for true Stamm gastrostomy by laparoscopy reproduces exactly the one done by laparotomy, without special equipment. It can be made since the neonatal period, in all the circumstances when a laparoscopy is possible.
Resumo:
The electron transmission and bound state properties of a quantum wire with a sharp bend at arbitrary angle are studied, extending results on the right angle sharp bend (the L¿shaped wire). These new results are compared to those of a similar structure, the circular bend wire. The possibility of using a bent wire to perform transistor action is also discussed.
Resumo:
INTRODUCTION: Occupational exposure to grain dust causes respiratory symptoms and pathologies. To decrease these effects, major changes have occurred in the grain processing industry in the last twenty years. However, there are no data on the effects of these changes on workers' respiratory health. OBJECTIVES: The aim of this study was to evaluate the respiratory health of grain workers and farmers involved in different steps of the processing industry of wheat, the most frequently used cereal in Europe, fifteen years after major improvements in collective protective equipment due to mechanisation. MATERIALS AND METHOD: Information on estimated personal exposure to wheat dust was collected from 87 workers exposed to wheat dust and from 62 controls. Lung function (FEV1, FVC, and PEF), exhaled nitrogen monoxide (FENO) and respiratory symptoms were assessed after the period of highest exposure to wheat during the year. Linear regression models were used to explore the associations between exposure indices and respiratory effects. RESULTS: Acute symptoms - cough, sneezing, runny nose, scratchy throat - were significantly more frequent in exposed workers than in controls. Increased mean exposure level, increased cumulative exposure and chronic exposure to more than 6 mg.m (-3) of inhaled wheat dust were significantly associated with decreased spirometric parameters, including FEV1 and PEF (40 ml and 123 ml.s (-1) ), FEV1 and FVC (0.4 ml and 0.5 ml per 100 h.mg.m (-3) ), FEV1 and FVC (20 ml and 20 ml per 100 h at >6 mg.m (-3) ). However, no increase in FENO was associated with increased exposure indices. CONCLUSIONS: The lung functions of wheat-related workers are still affected by their cumulative exposure to wheat dust, despite improvements in the use of collective protective equipment.
Resumo:
The paper reviews the historical transformation of the European regulatory framework for electronic communications from the era dominated by state-owned enterprises to the presence of regulated competition. In the course of these developments, the vision of the roles of the public and private sectors in electronic communications changed in expected and unexpected ways. While the period is characterized by a shift toward less direct state intervention, the intensity of regulation has increased in many areas. Most recently, in the wake of the financial crisis, new forms of state intervention can be observed, including public investment in communications infrastructure and public-private partnerships. As a result of the reforms, Europe has been able to achieve major successes but it also suffered unanticipated setbacks compared to other regions. The European Union emerged as the global leader in mobile communications during the 1990s and was able to roll-out first-generation broadband access networks more rapidly than many of its peers. Recently, however, Europe as a whole has not performed as well in deploying next-generation networks and advanced mobile communications services. The paper offers a political-economic explanation for these developments and assesses their effects on the performance of the European electronic communications sector and the economy. From this analysis, the European model emerges as a unique institutional arrangement with peculiar advantages and disadvantages. Once these are recognized, sensible next steps to build the strengths while avoiding the weaknesses of the model can be seen more clearly.
Resumo:
La cigarette électronique produit de la vapeur à inhaler contenant du propylène-glycol, des arômes et de la nicotine libérée rapidement. 6,7% de la population suisse, surtout des fumeurs, ont essayé la cigarette électronique et 0,1% l'utilise quotidiennement. Malgré l'incertitude due au bas niveau de preuves, la cigarette électronique pourrait être efficace pour cesser ou réduire le tabagisme. La sécurité de la cigarette électronique est démontrée à court terme mais pas à long terme ; sa toxicité semble très inférieure à celle du tabac. Les non-fumeurs et les jeunes utilisent peu la cigarette électronique qui ne semble pas les amener au tabagisme. Les mesures de santé publique recommandées sont la régulation du produit avec contrôle de la qualité ainsi que l'interdiction d'usage dans les lieux publics, de publicité et de vente aux mineurs. Electronic cigarettes are devices producing vapour containing propylene-glycol, flavourings and quickly delivered nicotine. 6.7% of the Swiss population, mainly smokers, experimented the electronic cigarette while 0.1% use it daily. Despite uncertainty due to the low level of evidence, electronic cigarettes might be effective for smoking cessation and reduction. The safety of electronic cigarettes is demonstrated at short-term but not at long-term; however its eventual toxicity is likely to be much lower than tobacco. Use of electronic cigarettes by non-smokers and youth who do not smoke is low and seems unlikely to lead them to tobacco use. Recommended public health measures include product regulation with quality control, ban in public places, prohibition of advertising and sales to minors.
Resumo:
Les pistolets à impulsion électrique (PIE) sont de plus en plus fréquemment utilisés en Europe ces dernières années, le modèle le plus connu étant le Taser®. Les connaissances scientifiques concernant les PIE et leurs effets potentiels restent toutefois limitées. Nous avons conduit une revue de littérature afin d'évaluer les implications potentielles de leur utilisation en termes de sécurité, de morbidité et de mortalité. Une exposition unique chez un individu sain peut généralement être considérée comme peu dangereuse. Les sujets à risque de complications sont les individus exposés à de multiples décharges, les personnes sous l'influence de substances psychoactives, ceux qui montrent des signes d'agitation extrême, ou encore les individus présentant des comorbidités médicales. L'éventail des complications pouvant survenir lors de leur exposition est large et inclut les lésions provoquées par les impacts des électrodes, les traumatismes liés à la chute induite par la paralysie transitoire ou des complications cardiovasculaires. Dans ce contexte, les personnes exposées doivent être examinées attentivement, et les éventuelles lésions traumatiques doivent être exclues. The use of electronic control devices (ECD), such as the Taser®, has increased in Europe over the past decade. However, scientific data concerning the potential health impact of ECD usage remains limited. We reviewed the scientific literature in order to evaluate the safety, mortality, and morbidity associated with ECD use. Exposure of a healthy individual to a single ECD electroshock can be considered generally safe. Complications can, however, occur if the patient is subject to multiple electroshocks, if the patient has significant medical comorbidities, or when exposure is associated with drug abuse or agitated delirium. The broad spectrum of potential complications associated with ECD exposure includes direct trauma caused by the ECD electrodes, injuries caused by the transient paralysis-induced fall, and cardiovascular events. An ECD-exposed patient requires careful examination during which traumatic injuries are actively sought out.
Resumo:
How to recognize, announce and analyze incidents in internal medicine units is a daily challenge that is taught to all hospital staff. It allows suggesting useful improvements for patients, as well as for the medical department and the institution. Here is presented the assessment made in the CHUV internal medicine department one year after the beginning of the institutional procedure which promotes an open process regarding communication and risk management. The department of internal medicine underlines the importance of feedback to the reporters, ensures the staff of regular follow-up concerning the measures being taken and offers to external reporters such as general practioners the possibility of using this reporting system too.
Resumo:
Objectifs: Dans certains pays, les cigarettes électroniques contenant de la nicotine (e-cigarettes) sont considérées comme des produits de consommation courante, sans régulation spécifique. Dans d'autres (comme en Suisse), la vente d'e-cigarettes contenant de la nicotine est interdite, malgré l'importante demande de nombreux fumeurs de pouvoir les obtenir. Au vu du manque de données scientifiques sur l'efficacité et la sécurité à long-terme de ces produits, les spécialistes de la lutte contre le tabagisme se trouvent divisés sur la question de leur régulation. Afin d'obtenir un consensus parmi ces experts que nous puissions transmettre aux autorités sanitaires, nous avons réalisé une étude d'avis d'experts sur le plan national. Méthode : Nous avons utilisé une méthodologie Delphi, à l'aide de questionnaires électroniques, afin de synthétiser l'opinion d'experts suisses sur la question de la cigarette électronique. Participants : 40 experts suisses représentant l'ensemble de la Suisse. Mesures : Nous avons mesuré le degré de consensus entre les experts au sujet de recommandations touchant à la régulation, la vente et l'utilisation de l'e-cigarette contenant de la nicotine, ainsi que leur opinion générale sur le produit. De nouvelles recommandations et déclarations ont été formulées en tenant compte des réponses et des commentaires des participants. Résultats : Un consensus entre les experts a établi que l'e-cigarette contenant de la nicotine devrait être accessible en Suisse, mais seulement dans des conditions spécifiques. La vente devrait être réservée aux adultes, en utilisant des standards de qualité, une limite de concentration maximale de nicotine, et être accompagnée d'une liste d'ingrédients autorisés. La publicité devrait être restreinte et l'utilisation de l'e- cigarette devrait être interdite dans les lieux publics. Conclusions : Ces recommandations permettent de regrouper trois principes : 1) le principe de réalité, étant donné que le produit est déjà disponible sur le marché ; 2) le principe de prévention, puisque l'e- cigarette procure une alternative au tabac pour les fumeurs actuels, et 3) le principe de précaution, afin de protéger les mineurs et les non-fumeurs, étant donné que les effets à long-terme ne sont pas encore connus. Les autorités suisses devraient mettre en place une législation spécifique afin d'autoriser l'e- cigarette contenant de la nicotine.
Improving coronary artery bypass graft durability: use of the external saphenous vein graft support.
Resumo:
Coronary bypass grafting remains the best option for patients suffering from multivessel coronary artery disease, and the saphenous vein is used as an additional conduit for multiple complete revascularizations. However, the long-term vein graft durability is poor, with almost 75% of occluded grafts after 10 years. To improve the durability, the concept of an external supportive structure was successfully developed during the last years: the eSVS Mesh device (Kips Bay Medical) is an external support for vein graft made of weft-knitted nitinol wire into a tubular form with an approximate length of 24 cm and available in three diameters (3.5, 4.0 and 4.5 mm). The device is placed over the outer wall of the vein and carefully deployed to cover the full length of the graft. The mesh is flexible for full adaptability to the heart anatomy and is intended to prevent kinking and dilatation of the vein in addition to suppressing the intima hyperplasia induced by the systemic blood pressure. The device is designed to reduce the vein diameter of about 15-20% at most to prevent the vein radial expansion induced by the arterial blood pressure, and the intima hyperplasia leading to the graft failure. We describe the surgical technique for preparing the vein graft with the external saphenous vein graft support (eSVS Mesh) and we share our preliminary clinical results.