965 resultados para Elective ventilation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this thesis project, a building in Vegagatan 12, Gävle has been analysed in order to see why it does consume more energy than it was expected. This building is a low energy building certified by Miljöbyggnad and it should use less than 55kWh/m2 year and nowadays it is using 62.23 kWh/m2. To get the needed data, some information about the building has been gathered, some measurements have been done in the building and some calculations have been done with those measurements. Finally, some possible solutions have been offered to reduce the energy use of the building. Insulating the floor, the pipes and the walls, reducing the indoor temperature in winter... All of these changes need the help of environmentally friendly attitudes, which is a very important fact in low energy buildings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To identify the level of malnutrition and complications observed in Malaysia. Methods: A prospective, observational study was conducted with the objectives of identifying the degree of malnutrition, complications and the need for nutritional support in elective surgical patients. Collection of data was performed in local tertiary hospitals using a Patient Generated Subjective Global Assessment (PG - SGA) nutritional screening tool and medical records. Results: A total of 50 patients electively admitted for surgery were included. The results demonstrated that there was a significant increase in malnourished patients post-surgery compared to pre-surgery (p = 0.0001). Most interesting was the significant number of complications observed post-surgery compared to pre-surgery (p = 0.035) which was associated to the poor level of nutrition. The most common type of complications noted post-surgery were nosocomial infection, wound infection and readmission. Conclusion: Malnutrition is prevalent pre- and post-operatively in Malaysia. Therefore, focus on the outcome of these malnourished patients should be performed to reduce complications associated with poor nutrition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le nettoyage des systèmes de Chauffage, Ventilation et Climatisation de l’Air est important pour assurer une bonne qualité d’air intérieur. Le déclenchement de leur nettoyage est basé sur une inspection visuelle qui ne tient pas compte du contenu en moisissures, lesquelles ont des effets sur le système respiratoire. Cette recherche vise à proposer une méthode d’évaluation du contenu en moisissures afin d’aider les gestionnaires d’immeuble. Cinq générations de poussières ont été effectuées pour simuler un conduit de ventilation. Une cassette modifiée 37 mm et un filtre CPV pré-pesés ont utilisés pour collecter les poussières déposées avec une pompe calibrée à 15L/min. Les pourcentages de collecte des cassettes et des filtres ont été calculés pour 54 échantillons. Dix générations supplémentaires de poussières ont été effectuées concomitamment avec la génération de spores. Soixante échantillons ont été analysés selon quatre méthodes : culture, comptage direct des spores par microscopie (CDSM), dosage de β-N-acétylhexosaminidase (NAHA), 18S-q-PCR. La limite de détection (LD), la réplicabilité, la répétabilité, le nombre de spores et le coefficient de corrélation (r) ont été déterminés. Les récupérations de poussières étaient supérieures à 84%. Selon la méthode analytique, les concentrations médianes de spores/100 cm² allaient de 10 000 à 815 000. Les LD variaient dépendamment de la méthode de 120 à 218 000 spores/100 cm² et r de -0,08 à 0,83. La réplicabilité et la répétabilité étaient de 1% et 1% pour PCR; 5% et 10% pour CDSM; 6% et 15% pour NAHA; 12% et 11% pour culture. La méthode de collecte a démontré une excellente efficacité de récupération. La PCR est la méthode analytique recommandée pour l’évaluation fongique des systèmes de ventilation. Une validation terrain est en cours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: La ventilation non invasive (VNI) est un outil utilisé en soins intensifs pédiatriques (SIP) pour soutenir la détresse respiratoire aigüe. Un échec survient dans près de 25% des cas et une mauvaise synchronisation patient-ventilateur est un des facteurs impliqués. Le mode de ventilation NAVA (neurally adjusted ventilatory assist) est asservi à la demande ventilatoire du patient. L’objectif de cette étude est d’évaluer la faisabilité et la tolérance des enfants à la VNI NAVA et l’impact de son usage sur la synchronie et la demande respiratoire. Méthode: Étude prospective, physiologique, croisée incluant 13 patients nécessitant une VNI dans les SIP de l’hôpital Ste-Justine entre octobre 2011 et mai 2013. Les patients ont été ventilés successivement en VNI conventionnelle (30 minutes), en VNI NAVA (60 minutes) et en VNI conventionnelle (30 minutes). L’activité électrique du diaphragme (AEdi) et la pression des voies aériennes supérieures ont été enregistrées pour évaluer la synchronie. Résultats: La VNI NAVA est faisable et bien tolérée chez tous les enfants. Un adolescent a demandé l’arrêt précoce de l’étude en raison d’anxiété reliée au masque sans fuite. Les délais inspiratoires et expiratoires étaient significativement plus courts en VNI NAVA comparativement aux périodes de VNI conventionnelle (p< 0.05). Les efforts inefficaces étaient moindres en VNI NAVA (résultats présentés en médiane et interquartiles) : 0% (0 - 0) en VNI NAVA vs 12% (4 - 20) en VNI conventionnelle initiale et 6% (2 - 22) en VNI conventionnelle finale (p< 0.01). Globalement, le temps passé en asynchronie a été réduit à 8% (6 - 10) en VNI NAVA, versus 27% (19 - 56) et 32% (21 - 38) en périodes de VNI conventionnelle initiale et finale, respectivement (p= 0.05). Aucune différence en termes de demande respiratoire n’a été observée. Conclusion: La VNI NAVA est faisable et bien tolérée chez les enfants avec détresse respiratoire aigüe et permet une meilleure synchronisation patient-ventilateur. De plus larges études sont nécessaires pour évaluer l’impact clinique de ces résultats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le nettoyage des systèmes de Chauffage, Ventilation et Climatisation de l’Air est important pour assurer une bonne qualité d’air intérieur. Le déclenchement de leur nettoyage est basé sur une inspection visuelle qui ne tient pas compte du contenu en moisissures, lesquelles ont des effets sur le système respiratoire. Cette recherche vise à proposer une méthode d’évaluation du contenu en moisissures afin d’aider les gestionnaires d’immeuble. Cinq générations de poussières ont été effectuées pour simuler un conduit de ventilation. Une cassette modifiée 37 mm et un filtre CPV pré-pesés ont utilisés pour collecter les poussières déposées avec une pompe calibrée à 15L/min. Les pourcentages de collecte des cassettes et des filtres ont été calculés pour 54 échantillons. Dix générations supplémentaires de poussières ont été effectuées concomitamment avec la génération de spores. Soixante échantillons ont été analysés selon quatre méthodes : culture, comptage direct des spores par microscopie (CDSM), dosage de β-N-acétylhexosaminidase (NAHA), 18S-q-PCR. La limite de détection (LD), la réplicabilité, la répétabilité, le nombre de spores et le coefficient de corrélation (r) ont été déterminés. Les récupérations de poussières étaient supérieures à 84%. Selon la méthode analytique, les concentrations médianes de spores/100 cm² allaient de 10 000 à 815 000. Les LD variaient dépendamment de la méthode de 120 à 218 000 spores/100 cm² et r de -0,08 à 0,83. La réplicabilité et la répétabilité étaient de 1% et 1% pour PCR; 5% et 10% pour CDSM; 6% et 15% pour NAHA; 12% et 11% pour culture. La méthode de collecte a démontré une excellente efficacité de récupération. La PCR est la méthode analytique recommandée pour l’évaluation fongique des systèmes de ventilation. Une validation terrain est en cours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: La ventilation non invasive (VNI) est un outil utilisé en soins intensifs pédiatriques (SIP) pour soutenir la détresse respiratoire aigüe. Un échec survient dans près de 25% des cas et une mauvaise synchronisation patient-ventilateur est un des facteurs impliqués. Le mode de ventilation NAVA (neurally adjusted ventilatory assist) est asservi à la demande ventilatoire du patient. L’objectif de cette étude est d’évaluer la faisabilité et la tolérance des enfants à la VNI NAVA et l’impact de son usage sur la synchronie et la demande respiratoire. Méthode: Étude prospective, physiologique, croisée incluant 13 patients nécessitant une VNI dans les SIP de l’hôpital Ste-Justine entre octobre 2011 et mai 2013. Les patients ont été ventilés successivement en VNI conventionnelle (30 minutes), en VNI NAVA (60 minutes) et en VNI conventionnelle (30 minutes). L’activité électrique du diaphragme (AEdi) et la pression des voies aériennes supérieures ont été enregistrées pour évaluer la synchronie. Résultats: La VNI NAVA est faisable et bien tolérée chez tous les enfants. Un adolescent a demandé l’arrêt précoce de l’étude en raison d’anxiété reliée au masque sans fuite. Les délais inspiratoires et expiratoires étaient significativement plus courts en VNI NAVA comparativement aux périodes de VNI conventionnelle (p< 0.05). Les efforts inefficaces étaient moindres en VNI NAVA (résultats présentés en médiane et interquartiles) : 0% (0 - 0) en VNI NAVA vs 12% (4 - 20) en VNI conventionnelle initiale et 6% (2 - 22) en VNI conventionnelle finale (p< 0.01). Globalement, le temps passé en asynchronie a été réduit à 8% (6 - 10) en VNI NAVA, versus 27% (19 - 56) et 32% (21 - 38) en périodes de VNI conventionnelle initiale et finale, respectivement (p= 0.05). Aucune différence en termes de demande respiratoire n’a été observée. Conclusion: La VNI NAVA est faisable et bien tolérée chez les enfants avec détresse respiratoire aigüe et permet une meilleure synchronisation patient-ventilateur. De plus larges études sont nécessaires pour évaluer l’impact clinique de ces résultats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indoor environmental conditions in classrooms, in particular temperature and indoor air quality, influence students’ health, attitude and performance. In recent years, several studies regarding indoor environmental quality of classrooms were published and natural ventilation proved to have great potential, particularly in southern European climate. This research aimed to evaluate indoor environmental conditions in eight schools and to assess their improvement potential by simple natural ventilation strategies. Temperature, relative humidity and carbon dioxide concentration were measured in 32 classrooms. Ventilation performance of the classrooms was characterized using two techniques, first by fan pressurization measurements of the envelope airtightness and later by tracer gas measurements of the air change rate assuming different envelope conditions. A total of 110 tracer gas measurements were made and the results validated ventilation protocols that were tested afterward. The results of the ventilation protocol implementation were encouraging and, overall, a decrease on the CO2 concentration was observed without modifying the comfort conditions. Nevertheless, additional measurements must be performed for winter conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mechanisms contributing to pulmonary and systemic injury induced by high tidal volume (VT) mechanical ventilation are not well known. We tested the hypothesis that increased peroxynitrite formation is involved in organ injury and dysfunction induced by mechanical ventilation. Male Sprague-Dawley rats were subject to low- (VT, 9 mL/kg; positive end-expiratory pressure, 5 cmH2O) or high- (VT, 25 mL/kg; positive end-expiratory pressure, 0 cmH2O) VT mechanical ventilation for 120 min, and received 1 of 3 treatments: 3-aminobenzamide (3-AB, 10 mg/kg, intravenous, a poly adenosine diphosphate ribose polymerase [PARP] inhibitor), or the metalloporphyrin manganese(III) tetrakis(1-methyl-4-pyridyl)porphyrin (MnTMPyP, 5 mg/kg intravenous, a peroxynitrite scavenger), or no treatment (control group), 30 min before starting the mechanical ventilation protocol (n = 8 per group, 6 treatment groups). We measured mean arterial pressure, peak inspiratory airway pressure, blood chemistry, and gas exchange. Oxidation (fluorescence for oxidized dihydroethidium), protein nitration (immunofluorescence and Western blot for 3-nitrotyrosine), PARP protein (Western blot) and gene expression of the nitric oxide (NO) synthase (NOS) isoforms (quantitative real-time reverse transcription polymerase chain reaction) were measured in lung and vascular tissue. Lung injury was quantified by light microscopy. High-VT mechanical ventilation was associated with hypotension, increased peak inspiratory airway pressure, worsened oxygenation; oxidation and protein nitration in lung and aortic tissue; increased PARP protein in lung; up-regulation of NOS isoforms in lung tissue; signs of diffuse alveolar damage at histological examination. Treatment with 3AB or MnTMPyP attenuated the high-VT mechanical ventilation-induced changes in pulmonary and cardiovascular function; down-regulated the expression of NOS1, NOS2, and NOS3; decreased oxidation and nitration in lung and aortic tissue; and attenuated histological changes. Increased peroxynitrite formation is involved in mechanical ventilation-induced pulmonary and vascular dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefits of prone position ventilation are well demonstrated in the severe forms of acute respiratory distress syndrome, but not in the milder forms. We investigated the effects of prone position on arterial blood gases, lung inflammation, and histology in an experimental mild acute lung injury (ALI) model. ALI was induced in Wistar rats by intraperitoneal Escherichia coli lipopolysaccharide (LPS, 5 mg/kg). After 24 h, the animals with PaO2/FIO2 between 200 and 300 mmHg were randomized into 2 groups: prone position (n = 6) and supine position (n = 6). Both groups were compared with a control group (n = 5) that was ventilated in the supine position. All of the groups were ventilated for 1 h with volume-controlled ventilation mode (tidal volume = 6 ml/kg, respiratory rate = 80 breaths/min, positive end-expiratory pressure = 5 cmH2O, inspired oxygen fraction = 1). Significantly higher lung injury scores were observed in the LPS-supine group compared to the LPS-prone and control groups (0.32 ± 0.03; 0.17 ± 0.03 and 0.13 ± 0.04, respectively) (p < 0.001), mainly due to a higher neutrophil infiltration level in the interstitial space and more proteinaceous debris that filled the airspaces. Similar differences were observed when the gravity-dependent lung regions and non-dependent lung regions were analyzed separately (p < 0.05). The BAL neutrophil content was also higher in the LPS-supine group compared to the LPS-prone and control groups (p < 0.05). There were no significant differences in the wet/dry ratio and gas exchange levels. In this experimental extrapulmonary mild ALI model, prone position ventilation for 1 h, when compared with supine position ventilation, was associated with lower lung inflammation and injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La ventilation liquidienne totale (VLT) consiste à remplir les poumons d'un liquide perfluorocarbone (PFC). Un respirateur liquidien assure la ventilation par un renouvellement cyclique de volume courant de PFC oxygéné et à température contrôlée. Ayant une capacité thermique volumique 1665 fois plus élevée que l'air, le poumon rempli de PFC devient un échangeur de chaleur performant avec la circulation pulmonaire. La température du PFC inspiré permet ainsi de contrôler la température artérielle, et par le fait même, le refroidissement des organes et des tissus. Des résultats récents d'expérimentations animales sur petits animaux ont démontré que le refroidissement ultra-rapide par VLT hypothermisante (VLTh) avait d'importants effets neuroprotecteurs et cardioprotecteurs. Induire rapidement et efficacement une hypothermie chez un patient par VLTh est une technique émergente qui suscite de grands espoirs thérapeutiques. Par contre, aucun dispositif approuvé pour la clinique n'est disponible et aucun résultat de VLTh sur humain n'est encore disponible. Le problème se situe dans le fait de contrôler la température du PFC inspiré de façon optimale pour induire une hypothermie chez l'humain tout en s'assurant que la température cardiaque reste supérieure à 30 °C pour éviter tout risque d'arythmie. Cette thèse présente le développement d'un modèle thermique paramétrique d'un sujet en VLTh complètement lié à la physiologie. Aux fins de validation du modèle sur des ovins pédiatriques et adultes, le prototype de respirateur liquidien Inolivent pour nouveau-né a dû être reconçu et adapté pour ventiler de plus gros animaux. Pour arriver à contrôler de façon optimale la température du PFC inspiré, un algorithme de commande optimale sous-contraintes a été développé. Après la validation du modèle thermique du nouveau-né à l'adulte par expérimentations animales, celui-ci a été projeté à l'humain. Afin de réduire le temps de calcul, un passage du modèle thermique en temps continu vers un modèle discret cycle-par-cycle a été effectué. À l'aide de la commande optimale et du développement numérique d'un profil de ventilation liquidienne chez des patients humains, des simulations d'induction d'hypothermie par VLTh ont pu être réalisées. La validation expérimentale du modèle thermique sur ovins nouveau-nés (5 kg), juvéniles (22 kg) et adultes (61 kg) a montré que celui-ci permettait de prédire les températures artérielles systémiques, du retour veineux et rectales. La projection à l'humain a permis de démontrer qu'il est possible de contrôler la température du PFC de façon optimale en boucle ouverte si le débit cardiaque et le volume mort thermique sont connus. S'ils ne peuvent être mesurés, la commande optimale pour le pire cas peut être calculée rendant l'induction d'hypothermie par VLTh sécuritaire pour tous les patients, mais diminuant quelque peu les vitesses de refroidissement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

• Introducción: El síndrome de abstinencia (SA) es el conjunto de síntomas y signos que se producen al suspender bruscamente la administración de un fármaco una vez se haya establecido dependencia física. • Objetivos: Caracterizar los pacientes que presentan SA secundario a opiodes (OP) y/o benzodiacepinas(BZ) durante la hospitalización en las unidades de cuidados intensivos pediátricos de la Clínica Infantil Colsubsidio (CIC) y Hospital del Niño de Panamá (HDN) del 1 de abril al 30 de septiembre del 2016. • Materiales y métodos: se realizó un estudio descriptivo, longitudinal, prospectivo. Incluimos 189 pacientes en la CIC y 144 pacientes en el HDN. Se utilizó la escala SOPHIA para el diagnóstico de SA, las escalas COMFORT para evaluar la sedación en pacientes ventilados no relajados y la escala FLACC para evaluar la analgesia. Se utilizó software StataV12® para el análisis estadístico. • Resultados: se reportó una incidencia global de SA de 6.1/100 días personas. La incidencia acumulada de SA fue de 56.08% y 29.86% para la CIC y el HDN respectivamente. En la CIC el 69.81% de los pacientes que requirieron infusión de OP y BZ desarrollaron SA. Se reportó una dosis acumulada de fentanyl de 530.34 ± 276.49 mcg/kg. Con respecto al HDN, de los pacientes que recibieron opioides y benzodiacepinas el 53.49 % desarrollaron SA. • Conclusión: El SA secundario a opioides y/o benzodiacepinas es frecuente en nuestras unidades con una incidencia variable, es mayor la presentación del SA al usar ambos fármacos, mayores dosis acumuladas y más días de infusión continua.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The past few decades have seen major impacts of different pandemics and mass casualty events on health resource use in terms of rising health cost and increased mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerous types of acute respiratory failure are routinely treated using non-invasive ventilatory support (NIV). Its efficacy is well documented: NIV lowers intubation and death rates in various respiratory disorders. It can be delivered by means of face masks or head helmets. Currently the scientific community’s interest about NIV helmets is mostly focused on optimising the mixing between CO2 and clean air and on improving patient comfort. To this end, fluid dynamic analysis plays a particularly important role and a two- pronged approach is frequently employed. While on one hand numerical simulations provide information about the entire flow field and different geometries, they exhibit require huge temporal and computational resources. Experiments on the other hand help to validate simulations and provide results with a much smaller time investment and thus remain at the core of research in fluid dynamics. The aim of this thesis work was to develop a flow bench and to utilise it for the analysis of NIV helmets. A flow test bench and an instrumented mannequin were successfully designed, produced and put into use. Experiments were performed to characterise the helmet interface in terms of pressure drop and flow rate drop over different inlet flow rates and outlet pressure set points. Velocity measurements by means of Particle Image Velocimetry were performed. Pressure drop and flow rate characteristics from experiments were contrasted with CFD data and sufficient agreement was observed between both numerical and experimental results. PIV studies permitted qualitative and quantitative comparisons with numerical simulation data and offered a clear picture of the internal flow behaviour, aiding the identification of coherent flow features.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To analyze the effects of treatment approach on the outcomes of newborns (birth weight [BW] < 1,000 g) with patent ductus arteriosus (PDA), from the Brazilian Neonatal Research Network (BNRN) on: death, bronchopulmonary dysplasia (BPD), severe intraventricular hemorrhage (IVH III/IV), retinopathy of prematurity requiring surgical (ROPsur), necrotizing enterocolitis requiring surgery (NECsur), and death/BPD. This was a multicentric, cohort study, retrospective data collection, including newborns (BW < 1000 g) with gestational age (GA) < 33 weeks and echocardiographic diagnosis of PDA, from 16 neonatal units of the BNRN from January 1, 2010 to Dec 31, 2011. Newborns who died or were transferred until the third day of life, and those with presence of congenital malformation or infection were excluded. Groups: G1 - conservative approach (without treatment), G2 - pharmacologic (indomethacin or ibuprofen), G3 - surgical ligation (independent of previous treatment). Factors analyzed: antenatal corticosteroid, cesarean section, BW, GA, 5 min. Apgar score < 4, male gender, Score for Neonatal Acute Physiology Perinatal Extension (SNAPPE II), respiratory distress syndrome (RDS), late sepsis (LS), mechanical ventilation (MV), surfactant (< 2 h of life), and time of MV. death, O2 dependence at 36 weeks (BPD36wks), IVH III/IV, ROPsur, NECsur, and death/BPD36wks. Student's t-test, chi-squared test, or Fisher's exact test; Odds ratio (95% CI); logistic binary regression and backward stepwise multiple regression. Software: MedCalc (Medical Calculator) software, version 12.1.4.0. p-values < 0.05 were considered statistically significant. 1,097 newborns were selected and 494 newborns were included: G1 - 187 (37.8%), G2 - 205 (41.5%), and G3 - 102 (20.6%). The highest mortality was observed in G1 (51.3%) and the lowest in G3 (14.7%). The highest frequencies of BPD36wks (70.6%) and ROPsur were observed in G3 (23.5%). The lowest occurrence of death/BPD36wks occurred in G2 (58.0%). Pharmacological (OR 0.29; 95% CI: 0.14-0.62) and conservative (OR 0.34; 95% CI: 0.14-0.79) treatments were protective for the outcome death/BPD36wks. The conservative approach of PDA was associated to high mortality, the surgical approach to the occurrence of BPD36wks and ROPsur, and the pharmacological treatment was protective for the outcome death/BPD36wks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

to investigate the pulmonary response to exercise of non-morbidly obese adolescents, considering the gender. a prospective cross-sectional study was conducted with 92 adolescents (47 obese and 45 eutrophic), divided in four groups according to obesity and gender. Anthropometric parameters, pulmonary function (spirometry and oxygen saturation [SatO2]), heart rate (HR), blood pressure (BP), respiratory rate (RR), and respiratory muscle strength were measured. Pulmonary function parameters were measured before, during, and after the exercise test. BP and HR were higher in obese individuals during the exercise test (p = 0.0001). SatO2 values decreased during exercise in obese adolescents (p = 0.0001). Obese males had higher levels of maximum inspiratory and expiratory pressures (p = 0.0002) when compared to obese and eutrophic females. Obese males showed lower values of maximum voluntary ventilation, forced vital capacity, and forced expiratory volume in the first second when compared to eutrophic males, before and after exercise (p = 0.0005). Obese females had greater inspiratory capacity compared to eutrophic females (p = 0.0001). Expiratory reserve volume was lower in obese subjects when compared to controls (p ≤ 0,05). obese adolescents presented changes in pulmonary function at rest and these changes remained present during exercise. The spirometric and cardiorespiratory values were different in the four study groups. The present data demonstrated that, in spite of differences in lung growth, the model of fat distribution alters pulmonary function differently in obese female and male adolescents.