990 resultados para ENDOSCOPIC TRACHEAL OCCLUSION
Resumo:
Study Design. Prospective clinical case series. Objective. To evaluate the clinical outcome of anterior endoscopic instrumention for scoliosis using the SRS-24 questionnaire and to examine how these scores change over a 2-year follow-up period. Summary of Background Data. Anterior endoscopic instrumentation correction has several advantages compared with open procedures. However, the clinical results of this technique using a validated outcome measure have rarely been reported in the literature. Methods. A total of 83 consecutive patients underwent endoscopic anterior instrumentation performed at a single unit. Patients completed the SRS-24 questionnaire before surgery and at 3, 6, 12, and 24 months after surgery. The SRS-24 scores were compared between each of the follow-up intervals. Results. The pain, general self-image, and function from back condition domains improved after surgery (P < 0.05). Activity level significantly improved between 3 and 6 months, and both function domains improved between 6 and 12 months (P < 0.05). None of the domains increased significantly after 1 year. Conclusions. Endoscopic anterior instrumentation for scoliosis significantly improved pain, self-image, and function. The greatest improvement in function occurred between 6 and 12 months after surgery. The SRS-24 scores at 1 year from surgery may provide a good indicator of patient outcome in the long-term.
Resumo:
Palliative care involves a multi-professional team approach to the provision of active, holistic care for patients and their families when the patient's disease is no longer responsive to curative treatment. Patient care encompasses medical and pharmacological intervention for symptom control, together with psychological, spiritual and social support for patients and families. Care is provided by teams in hospice, hospital or community environments. Although traditionally associated with providing care for cancer patients, palliative care services are increasingly providing for patients with non-malignant disease. Symptoms commonly associated with terminal phase of disease include pain, nausea, agitation, respiratory symptoms and general fatigue. During the last few days of life, patients may become weak, resulting in difficulty taking oral medication and have periods of unconsciousness. Some patients may require drug administration via subcutaneous infusion. A proportion of patients may develop difficulty clearing respiratory secretions causing a characteristic ‘death rattle’, which although not generally considered to be distressing for the patient, is often treated with a variety of anticholinergic drugs in an attempt to reduce the ‘noisy breathing’ for the benefit of relatives and others who may be closely associated with the patient.This study examined treatment of death rattle in two Hospices focusing on objective and subjective outcome measures in order to determine the efficacy of anticholinergic regimens in current use. Qualitative methods were employed to elicit attitudes of professionals and carers working closely with the patient. The number of patients recruited and monitored were small, many confounding factors were identified which questioned firstly the clinical rationale for administering anticholinergic drugs routinely to treat death rattle and secondly, the ethics of administering drug regimens to patients to treat death rattle with the primary aim of relieving distress for others. Ethnical issues, including those of consent are discussed in relation to their impact on the methodology of end of life studies in medicines management in palliative care.
Resumo:
We report a characterization of the acoustic sensitivity of microstructured polymer optical fiber interferometric sensors at ultrasonic frequencies from 100kHz to 10MHz. The use of wide-band ultrasonic fiber optic sensors in biomedical ultrasonic and optoacoustic applications is an open alternative to conventional piezoelectric transducers. These kind of sensors, made of biocompatible polymers, are good candidates for the sensing element in an optoacoustic endoscope because of its high sensitivity, its shape and its non-brittle and non-electric nature. The acoustic sensitivity of the intrinsic fiber optic interferometric sensors depends strongly of the material which is composed of. In this work we compare experimentally the intrinsic ultrasonic sensitivities of a PMMA mPOF with other three optical fibers: a singlemode silica optical fiber, a single-mode polymer optical fiber and a multimode graded-index perfluorinated polymer optical fiber. © 2014 SPIE.
Resumo:
Focal points: A systematic review of the use of proton pump inhibitors was conducted among patients undergoing diagnostic fibreoptic endoscopic examination of the upper gastrointestinal tract during the period July 2001 to February 2002 inclusive A total of 2,557 patients received a PPI following endoscopy and healing doses were prescribed to 75.3 per cent of these patients An “unknown indication” was stated as a diagnosis in 958 patients (37.5 per cent) of patients studied Although endoscopic diagnosis does not appear possible in all cases, the present study demonstrates that NICE guidance to employ the lowest appropriate dose of PPI is followed
Resumo:
Opto-acoustic imaging (OAI) shows particular promise for in-vivo biomedical diagnostics. Its applications include cardiovascular, gastrointestinal and urogenital systems imaging. Opto-acoustic endoscopy (OAE) allows the imaging of body parts through cavities permitting entry. The critical parameter is the physical size of the device, allowing compatibility with current technology, while governing flexibility of the distal end of the endoscope based on the needs of the sensor. Polymer optical fibre (POF) presents a novel approach for endoscopic applications and has been positively discussed and compared in existing publications. A great advantage can be obtained for endoscopy due to a small size and array potential to provide discrete imaging speed improvements. Optical fibre exhibits numerous advantages over conventional piezo-electric transducers, such as immunity from electromagnetic interference and a higher resolution at small sizes. Furthermore, micro structured polymer optical fibres offer over 12 times the sensitivity of silica fibre. We present a polymer fibre Bragg grating ultrasound detector with a core diameter of 125 microns. We discuss the ultrasonic signals received and draw conclusions on the opportunities and challenges of applying this technology in biomedical applications.
Resumo:
Purpose: This study involved an extensive search for randomized controlled clinical trials comparing bilateral balanced and canine-guided dentures, and questioned whether a bilateral balanced occlusion is imperative for successful denture treatment. Materials and Methods: Studies were identified by searching electronic databases (PubMed/MEDLINE, ISI Web of Science, LILACS, and BBD). The keywords “denture” and “occlusion” were used. The minimum inclusion requirements were (1) randomized controlled trials with patients of any age wearing both maxillary and mandibular conventional complete dentures (CDs), (2) comparison between bilateral balanced and canine-guided dentures, and (3) assessment of masticatory function and/or patients’ satisfaction. Results: The search resulted in the identification of 5166 articles. Subsequently, 5156 articles were excluded on the basis of title and abstract. By the end of the search phase, seven randomized controlled trials were considered eligible. Conclusions: Current scientific evidence suggests that bilateral balanced occlusion is not imperative for successful treatment with conventional CDs in average patients. More studies are necessary to identify if specific clinical conditions may benefit from a balanced occlusion.
Resumo:
The maintenance of masticatory function is especially important for patients wearing complete dentures due to their limitations. Thus, the bilateral balanced occlusal concept is used to achieve greater masticatory efficiency. However, a critical review of the literature reveals that there is not sufficient scientific evidence to support bilateral balanced occlusion as the most appropriate occlusal concept in complete dentures. Therefore, the aim of this study was to evaluate the masticatory efficiency in complete dentures wearers with bilateral balanced occlusion and canine guidance. A double-blinded controlled crossover clinical trial was conducted. The sample was composed by 24 edentulous patients who wore sets of complete dentures with both occlusal concepts during equal periods of 3 months. Objective data were collected through the masticatory efficiency test performed by the colorimetric method with the beads, in which capsules of a synthetic material enclosing fuchsine-containing granules were used. Subjective data were recorded by patient's ratings of their chewing function. No significant statistical difference was found for masticatory efficiency (p=0.095) between the two occlusal concepts studied. The results suggest that bilateral balanced occlusion does not improve the masticatory efficiency in complete denture wearers.
Resumo:
The maintenance of masticatory function is especially important for patients wearing complete dentures due to their limitations. Thus, the bilateral balanced occlusal concept is used to achieve greater masticatory efficiency. However, a critical review of the literature reveals that there is not sufficient scientific evidence to support bilateral balanced occlusion as the most appropriate occlusal concept in complete dentures. Therefore, the aim of this study was to evaluate the masticatory efficiency in complete dentures wearers with bilateral balanced occlusion and canine guidance. A double-blinded controlled crossover clinical trial was conducted. The sample was composed by 24 edentulous patients who wore sets of complete dentures with both occlusal concepts during equal periods of 3 months. Objective data were collected through the masticatory efficiency test performed by the colorimetric method with the beads, in which capsules of a synthetic material enclosing fuchsine-containing granules were used. Subjective data were recorded by patient's ratings of their chewing function. No significant statistical difference was found for masticatory efficiency (p=0.095) between the two occlusal concepts studied. The results suggest that bilateral balanced occlusion does not improve the masticatory efficiency in complete denture wearers.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Smart hydrogels for biomedical applications are highly researched materials. However, integrating them into a device for implantation is difficult. This paper investigates an integrated delivery device designed to deliver an electro-responsive hydrogel to a target location inside a blood vessel with the purpose of creating an occlusion. The paper describes the synthesis and characterization of a Pluronic/methacrylic acid sodium salt electro-responsive hydrogel. Application of an electrical bias decelerates the expansion of the hydrogel. An integrated delivery system was manufactured to deliver the hydrogel to the target location in the body. Ex vivo and in vivo experiments in the carotid artery of sheep were used to validate the concept. The hydrogel was able to completely occlude the blood vessel reducing the blood flow from 245 to 0 ml/min after implantation. Ex vivo experiments showed that the hydrogel was able to withstand physiological blood pressures of > 270 mm·Hg without dislodgement. The results showed that the electro-responsive hydrogel used in this paper can be used to create a long-term occlusion in a blood vessel without any apparent side effects. The delivery system developed is a promising device for the delivery of electro-responsive hydrogels.
Resumo:
Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.
Resumo:
Introduction. Subfascial Endoscopic Perforator Surgery (SEPS) enables the direct visualization and section of perforating veins. Morbidity and duration of hospitalization are both less than with conventional open surgery (Linton’s or Felder’s techniques). Patients and methods. A total of 322 legs from 285 patients with a mean age of 56 years (range 23-90) were treated at our Department from May 1996 to January 2010. In 309 cases, an endoscope (ETM Endoskopische Technik GmbH, Berlin, Germany) was introduced through a transverse incision approximately 1.5 cm in length and 10 cm from the tibial tuberosity, as with Linton’s technique. A spacemaker balloon dissector for SEPS, involving a second incision 6 cm from the first, was used in only 13 cases. Results. The procedure used in each case was decided on the basis of preoperative evaluation. SEPS and stripping were performed in 238 limbs (73.91%), SEPS and short stripping in 7 limbs (2.17%), SEPS and crossectomy in 51 limbs (15.84%), and SEPS alone in 26 limbs (8.07%). 103 patients presented a total of 158 trophic ulcers; the healing time was between 1 and 3 months, with a healing rate of 82.91% after 1 month and 98.73% after 3 months. Conclusion. Subfascial ligature of perforating veins is superior to sclerotherapy and minimally invasive suprafascial treatment for the treatment of CVI. It is easy to execute, minimally invasive and has few complications.