870 resultados para Contrast-to-noise ratio


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Flexible radio transmitters based on the Software-Defined Radio (SDR) concept are gaining an increased research importance due to the unparalleled proliferation of new wireless standards operating at different frequencies, using dissimilar coding and modulation schemes, and targeted for different ends. In this new wireless communications paradigm, the physical layer of the radio transmitter must be able to support the simultaneous transmission of multi-band, multi-rate, multi-standard signals, which in practice is very hard or very inefficient to implement using conventional approaches. Nevertheless, the last developments in this field include novel all-digital transmitter architectures where the radio datapath is digital from the baseband up to the RF stage. Such concept has inherent high flexibility and poses an important step towards the development of SDR-based transmitters. However, the truth is that implementing such radio for a real world communications scenario is a challenging task, where a few key limitations are still preventing a wider adoption of this concept. This thesis aims exactly to address some of these limitations by proposing and implementing innovative all-digital transmitter architectures with inherent higher flexibility and integration, and where improving important figures of merit, such as coding efficiency, signal-to-noise ratio, usable bandwidth and in-band and out-of-band noise will also be addressed. In the first part of this thesis, the concept of transmitting RF data using an entirely digital approach based on pulsed modulation is introduced. A comparison between several implementation technologies is also presented, allowing to state that FPGAs provide an interesting compromise between performance, power efficiency and flexibility, thus making them an interesting choice as an enabling technology for pulse-based all-digital transmitters. Following this discussion, the fundamental concepts inherent to pulsed modulators, its key advantages, main limitations and typical enhancements suitable for all-digital transmitters are also presented. The recent advances regarding the two most common classes of pulse modulated transmitters, namely the RF and the baseband-level are introduced, along with several examples of state-of-the-art architectures found on the literature. The core of this dissertation containing the main developments achieved during this PhD work is then presented and discussed. The first key contribution to the state-of-the-art presented here consists in the development of a novel ΣΔ-based all-digital transmitter architecture capable of multiband and multi-standard data transmission in a very flexible and integrated way, where the pulsed RF output operating in the microwave frequency range is generated inside a single FPGA device. A fundamental contribution regarding the simultaneous transmission of multiple RF signals is then introduced by presenting and describing novel all-digital transmitter architectures that take advantage of multi-gigabit data serializers available on current high-end FPGAs in order to transmit in a time-interleaved approach multiple independent RF carriers. Further improvements in this design approach allowed to provide a two-stage up-conversion transmitter architecture enabling the fine frequency tuning of concurrent multichannel multi-standard signals. Finally, further improvements regarding two key limitations inherent to current all-digital transmitter approaches are then addressed, namely the poor coding efficiency and the combined high quality factor and tunability requirements of the RF output filter. The followed design approach based on poliphase multipath circuits allowed to create a new FPGA-embedded agile transmitter architecture that significantly improves important figures of merit, such as coding efficiency and SNR, while maintains the high flexibility that is required for supporting multichannel multimode data transmission.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work several techniques to monitor the performance of optical networks were developed. These techniques are dedicated either to the measurement of the data signal parameters (optical signal to noise ratio and dispersion) or to the detection of physical failures on the network infrastructure. The optical signal to noise ratio of the transmitted signal was successfully monitored using methods based on the presence of Bragg gratings imprinted on high birefringent fibres that allowed the distinction of the signal from the noise due to its polarization properties. The monitoring of the signal group-velocity dispersion was also possible. In this case, a method based on the analysis of the electric spectrum of the signal was applied. It was experimentally demonstrated that this technique is applicable on both amplitude and phase modulated signals. It was also developed a technique to monitor the physical infrastructure of an optical access network. Once again, the application of Bragg gratings (this time imprinted on standard single mode fibres) was the basis of the developed method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho teve como objetivos a produção, caracterização e aplicação de microelétrodos (MEs) de diamante como sensores amperométricos e potenciométricos em sistemas de corrosão nos quais a agressividade do meio e a presença de produtos de corrosão, constituem obstáculos que podem diminuir o desempenho, ou inviabilizar a utilização, de outros tipos de sensores. Os microeléctrodos são baseados em filmes finos de diamante dopado com boro (BDD – Boron Doped Diamond) depositados sobre fios de tungsténio afiados, através do método de deposição química a partir da fase vapor, assistida por filamento quente (HFCVD – Hot Filament Chemical Vapor Deposition). A otimização das diversas etapas de fabricação dos MEs deu origem ao desenvolvimento de um novo sistema de afiamento eletroquímico para obtenção destes fios e a várias opções para a obtenção dos filmes de diamante condutor e seu isolamento com resinas para exposição apenas da ponta cilíndrica. A qualidade cristalina dos filmes de diamante foi avaliada por espectroscopia de Raman. Esta informação foi complementada com uma caracterização microestrutural dos filmes de diamante por microscopia eletrónica de varrimento (SEM), em que se fez a identificação da tipologia dos cristais como pertencendo às gamas de diamante nanocristalino ou microcristalino. Os filmes de BDD foram utilizados na sua forma não modificada, com terminações em hidrogénio e também com modificação da superfície através de tratamentos de plasma RF de CF4 e O2 indutores de terminações C-F no primeiro caso e de grupos C=O, C-O-C e C-OH no segundo, tal como determinado por XPS. A caracterização eletroquímica dos MEs não modificados revelou uma resposta voltamétrica com elevada razão sinal/ruído e baixa corrente capacitiva, numa gama de polarização quasi-ideal com extensão de 3 V a 4 V, dependente dos parâmetros de crescimento e pós-tratamentos de superfície. Estudou-se a reversibilidade de algumas reações heterogéneas com os pares redox Fe(CN)6 3-/4- e FcOH0/+ e verificou-se que a constante cinética, k0, é mais elevada em elétrodos com terminações em hidrogénio, nos quais não se procedeu a qualquer modificação da superfície. Estes MEs não modificados foram também testados na deteção de Zn2+ onde se observou, por voltametria cíclica, que a detecção da redução deste ião é linear numa escala log-log na gama de 10-5-10-2 M em 5 mM NaCl. Realizaram-se também estudos em sistemas de corrosão modelares, em que os microeléctrodos foram usados como sensores amperométricos para mapear a distribuição de oxigénio e Zn2+ sobre um par galvânico Zn-Fe, com recurso a um sistema SVET (Scanning Vibrating Electrode Technique). Foi possível detetar, com resolução lateral de 100 μm, um decréscimo da concentração de O2 junto a ambos os metais e produção de catiões de zinco no ânodo. Contudo verificou-se uma significativa deposição de zinco metálico na superfície dos ME utilizados. Os MEs com superfície modificada por plasma de CF4 foram testados como sensores de oxigénio dissolvido. A calibração dos microeléctrodos foi efetuada simultaneamente por voltametria cíclica e medição óptica através de um sensor de oxigénio comercial. Determinou-se uma sensibilidade de ~0.1422 nA/μM, com um limite de deteção de 0.63 μM. Os MEs modificados com CF4 foram também testados como sensores amperométricos com os quais se observou sensibilidade ao oxigénio dissolvido em solução, tendo sido igualmente utilizados durante a corrosão galvânica de pares Zn-Fe. Em alguns casos foi conseguida sensibilidade ao ião Zn2+ sem que o efeito da contaminação superficial com zinco metálico se fizesse sentir. Os microeléctrodos tratados em plasma de CF4 permitem uma boa deteção da distribuição de oxigénio, exibindo uma resposta mais rápida que os não tratados além de maior estabilidade de medição e durabilidade. Nos MEs em que a superfície foi modificada com plasma de O2 foi possível detetar, por cronopotenciometria a corrente nula, uma sensibilidade ao pH de ~51 mV/pH numa gama de pH 2 a pH 12. Este comportamento foi associado à contribuição determinante de grupos C-O e C=O, observados por XPS com uma razão O/C de 0,16. Estes MEs foram igualmente testados durante a corrosão galvânica do par Zn-Fe onde foi possível mapear a distribuição de pH associada ao desenvolvimento de regiões alcalinas causadas pela redução do oxigénio, acima da região catódica, e de regiões ácidas decorrentes da dissolução anódica do ânodo de zinco. Com o par galvânico imerso em 50 mM NaCl registou-se uma variação de pH aproximadamente entre 4,8 acima do ânodo de zinco a 9,3 sobre o cátodo de ferro. A utilização pioneira destes MEs como sensores de pH é uma alternativa promissora aos elétrodos baseados em membranas seletivas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we consider low-PMEPR (Peak-to-Mean Envelope Power Ratio) MC-CDMA (Multicarrier Coded Division Multiple Access) schemes. We develop frequencydomain turbo equalizers combined with an iterative estimation and cancellation of nonlinear distortion effects. Our receivers have relatively low complexity, since they allow FFT-based (Fast Fourier Transform) implementations. The proposed turbo receivers allow significant performance improvements at low and moderate SNR (Signal-to-Noise Ratio), even when a low-PMEPR MC-CDMA transmission is intended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Joint Video Team, composed by the ISO/IEC Moving Picture Experts Group (MPEG) and the ITU-T Video Coding Experts Group (VCEG), has standardized a scalable extension of the H.264/AVC video coding standard called Scalable Video Coding (SVC). H.264/SVC provides scalable video streams which are composed by a base layer and one or more enhancement layers. Enhancement layers may improve the temporal, the spatial or the signal-to-noise ratio resolutions of the content represented by the lower layers. One of the applications, of this standard is related to video transmission in both wired and wireless communication systems, and it is therefore important to analyze in which way packet losses contribute to the degradation of quality, and which mechanisms could be used to improve that quality. This paper provides an analysis and evaluation of H.264/SVC in error prone environments, quantifying the degradation caused by packet losses in the decoded video. It also proposes and analyzes the consequences of QoS-based discarding of packets through different marking solutions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this manuscript we tackle the problem of semidistributed user selection with distributed linear precoding for sum rate maximization in multiuser multicell systems. A set of adjacent base stations (BS) form a cluster in order to perform coordinated transmission to cell-edge users, and coordination is carried out through a central processing unit (CU). However, the message exchange between BSs and the CU is limited to scheduling control signaling and no user data or channel state information (CSI) exchange is allowed. In the considered multicell coordinated approach, each BS has its own set of cell-edge users and transmits only to one intended user while interference to non-intended users at other BSs is suppressed by signal steering (precoding). We use two distributed linear precoding schemes, Distributed Zero Forcing (DZF) and Distributed Virtual Signalto-Interference-plus-Noise Ratio (DVSINR). Considering multiple users per cell and the backhaul limitations, the BSs rely on local CSI to solve the user selection problem. First we investigate how the signal-to-noise-ratio (SNR) regime and the number of antennas at the BSs impact the effective channel gain (the magnitude of the channels after precoding) and its relationship with multiuser diversity. Considering that user selection must be based on the type of implemented precoding, we develop metrics of compatibility (estimations of the effective channel gains) that can be computed from local CSI at each BS and reported to the CU for scheduling decisions. Based on such metrics, we design user selection algorithms that can find a set of users that potentially maximizes the sum rate. Numerical results show the effectiveness of the proposed metrics and algorithms for different configurations of users and antennas at the base stations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A transimpedance amplifier (TIA) is used, in radiation detectors like the positron emission tomography(PET), to transform the current pulse produced by a photo-sensitive device into an output voltage pulse with a desired amplitude and shape. The TIA must have the lowest noise possible to maximize the output. To achieve a low noise, a circuit topology is proposed where an auxiliary path is added to the feedback TIA input, In this auxiliary path a differential transconductance block is used to transform the node voltage in to a current, this current is then converted to a voltage pulse by a second feedback TIA complementary to the first one, with the same amplitude but 180º out of phase with the first feedback TIA. With this circuit the input signal of the TIA appears differential at the output, this is used to try an reduced the circuit noise. The circuit is tested with two different devices, the Avalanche photodiodes (APD) and the Silicon photomultiplier (SIPMs). From the simulations we find that when using s SIPM with Rx=20kΩ and Cx=50fF the signal to noise ratio is increased from 59 when using only one feedback TIA to 68.3 when we use an auxiliary path in conjunction with the feedback TIA. This values where achieved with a total power consumption of 4.82mv. While the signal to noise ratio in the case of the SIPM is increased with some penalty in power consumption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Contemporary free-breathing non contrast enhanced cardiovascular magnetic resonance angiography (CMRA) was qualitatively and quantitatively evaluated to ascertain the reproducibility of the method for coronary artery luminal dimension measurements. SUBJECTS AND METHODS: Twenty-two healthy volunteers (mean age 32 +/- 7 years, 12 males) without coronary artery disease were imaged at 2 centers (1 each in Europe and North America) using navigator-gated and corrected SSFP CMRA on a commercial whole body 1.5T System. Repeat images of right (RCA, n = 21), left anterior descending (LAD, n = 14) and left circumflex (LCX, n = 14) coronary arteries were obtained in separate sessions using identical scan protocol and imaging parameters. True visible vessel length, signal-to-noise (SNR), contrast-to-noise ratios (CNR) and the average luminal diameter over the first 4 cm of the vessel were measured. Intra-observer, inter-observer and inter-scan reproducibility of coronary artery luminal diameter were determined using Pearson's correlation, Bland-Altman analysis and intraclass correlation coefficients (ICC). RESULTS: CNR, SNR and the mean length of the RCA, LAD and LCX imaged for original and repeat scans were not significantly different (all p > 0.30). There was a high degree of intra-observer, inter-observer and inter-scan agreements for RCA, LAD and LCX luminal diameter respectively on Bland-Altman and ICC analysis (ICC's for RCA: 0.98. 0.98 and 0.86; LAD: 0.89, 0.89 and 0.63; LCX: 0.95, 0.94 and 0.79). CONCLUSION: In a 2-center study, we demonstrate that free-breathing 3D SSFP CMRA can visualize long continuous segments of coronary vessels with highly reproducible measurements of luminal diameter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three-dimensional segmented echo planar imaging (3D-EPI) is a promising approach for high-resolution functional magnetic resonance imaging, as it provides an increased signal-to-noise ratio (SNR) at similar temporal resolution to traditional multislice 2D-EPI readouts. Recently, the 3D-EPI technique has become more frequently used and it is important to better understand its implications for fMRI. In this study, the temporal SNR characteristics of 3D-EPI with varying numbers of segments are studied. It is shown that, in humans, the temporal variance increases with the number of segments used to form the EPI acquisition and that for segmented acquisitions, the maximum available temporal SNR is reduced compared to single shot acquisitions. This reduction with increased segmentation is not found in phantom data and thus likely due to physiological processes. When operating in the thermal noise dominated regime, fMRI experiments with a motor task revealed that the 3D variant outperforms the 2D-EPI in terms of temporal SNR and sensitivity to detect activated brain regions. Thus, the theoretical SNR advantage of a segmented 3D-EPI sequence for fMRI only exists in a low SNR situation. However, other advantages of 3D-EPI, such as the application of parallel imaging techniques in two dimensions and the low specific absorption rate requirements, may encourage the use of the 3D-EPI sequence for fMRI in situations with higher SNR.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Différentes méthodes ayant pour objectif une utilisation optimale d'antennes radio-fréquences spécialisées en imagerie par résonance magnétique sont développées et validées. Dans un premier temps, il est démontré qu'une méthode alternative de combinaison des signaux provenant des différents canaux de réception d'un réseau d'antennes mène à une réduction significative du biais causé par la présence de bruit dans des images de diffusion, en comparaison avec la méthode de la somme-des-carrés généralement utilisée. Cette réduction du biais engendré par le bruit permet une amélioration de l'exactitude de l'estimation de différents paramètres de diffusion et de diffusion tensorielle. De plus, il est démontré que cette méthode peut être utilisée conjointement avec une acquisition régulière sans accélération, mais également en présence d'imagerie parallèle. Dans une seconde perspective, les bénéfices engendrés par l'utilisation d'une antenne d'imagerie intravasculaire sont étudiés. Suite à une étude sur fantôme, il est démontré que l'imagerie par résonance magnétique intravasculaire offre le potentiel d'améliorer significativement l'exactitude géométrique lors de mesures morphologiques vasculaires, en comparaison avec les résultats obtenus avec des antennes de surface classiques. Il est illustré qu'une exactitude géométrique comparable à celle obtenue grâce à une sonde ultrasonique intravasculaire peut être atteinte. De plus, plusieurs protocoles basés sur une acquisition de type balanced steady-state free-precession sont comparés dans le but de mettre en évidence différentes relations entre les paramètres utilisés et l'exactitude géométrique obtenue. En particulier, des dépendances entre la taille du vaisseau, le rapport signal-sur-bruit à la paroi vasculaire, la résolution spatiale et l'exactitude géométrique atteinte sont mises en évidence. Dans une même optique, il est illustré que l'utilisation d'une antenne intravasculaire permet une amélioration notable de la visualisation de la lumière d'une endoprothèse vasculaire. Lorsque utilisée conjointement avec une séquence de type balanced steady-state free-precession utilisant un angle de basculement spécialement sélectionné, l'imagerie par résonance magnétique intravasculaire permet d'éliminer complètement les limitations normalement engendrées par l'effet de blindage radio-fréquence de l'endoprothèse.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Il est bien connu que les enfants qui présentent un trouble de traitement auditif (TTA) ont de la difficulté à percevoir la parole en présence de bruit de fond. Cependant, il n’existe aucun consensus quant à l’origine de ces difficultés d’écoute. Ce programme de recherche est consacré à l’étude des incapacités sous-jacentes aux problèmes de perception de la parole dans le bruit chez les enfants présentant un TTA. Le Test de Phrases dans le Bruit (TPB) a été développé afin d’examiner si les difficultés de perception de la parole dans le bruit d’enfants ayant un TTA relèvent d’incapacités auditives, d’incapacités cognitivo-linguistiques ou des deux à la fois. Il comprend cinq listes de 40 phrases, composées de 20 phrases hautement prévisibles (HP) et de 20 phrases faiblement prévisibles (FP), de même qu’un bruit de verbiage. Le niveau de connaissance du mot clé (mot final) de chaque phrase a été vérifié auprès d’un groupe d’enfants âgés entre 5 et 7 ans. De plus, le degré d’intelligibilité des phrases dans le bruit et le niveau de prévisibilité ont été mesurées auprès d’adultes pour assurer l’équivalence entre les listes. Enfin, le TPB a été testé auprès d’un groupe de 15 adultes et d’un groupe de 69 enfants sans trouble auditif avant de l’administrer à des enfants ayant un TTA. Pour répondre à l’objectif général du programme de recherche, dix enfants présentant un TTA (groupe TTA) et dix enfants jumelés selon le genre et l’âge sans difficulté auditive (groupe témoin) ont été soumis aux listes de phrases du TPB selon différentes conditions sonores. Le groupe TTA a obtenu des performances significativement plus faibles comparativement au groupe témoin à la tâche de reconnaissance du mot final des phrases présentées en même temps qu’un bruit de verbiage compétitif, aux rapports signal-sur-bruit de 0, +3 et +4 dB. La moyenne de la différence des scores obtenue entre les phrases HP et FP à chaque condition expérimentale de bruit était similaire entre les deux groupes. Ces résultats suggèrent que les enfants ayant un TTA ne se distinguent pas des enfants du groupe témoin au plan de la compétence cognitivo-linguistique. L’origine des difficultés d’écoute de la parole dans le bruit dans le cas de TTA serait de nature auditive. Toutefois, les résultats des analyses de groupe diffèrent de ceux des analyses individuelles. Les divers profils de difficultés d’écoute identifiés auprès de cette cohorte appuient l’importance de continuer les investigations afin de mieux comprendre l’origine des problèmes de perception de la parole dans le bruit dans le cas de TTA. En connaissant mieux la nature de ces difficultés, il sera possible d’identifier les stratégies d’intervention de réadaptation spécifiques et efficaces.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Un nouveau contrôleur de EMCCD (Electron multiplying Charge Coupled Device) est présenté. Il permet de diminuer significativement le bruit qui domine lorsque la puce EMCCD est utilisé pour du comptage de photons: le bruit d'injection de charge. À l'aide de ce contrôleur, une caméra EMCCD scientifique a été construite, caractérisée en laboratoire et testée à l'observatoire du mont Mégantic. Cette nouvelle caméra permet, entre autres, de réaliser des observations de la cinématique des galaxies par spectroscopie de champ intégral par interférométrie de Fabry-Perot en lumière Ha beaucoup plus rapidement, ou de galaxies de plus faible luminosité, que les caméras à comptage de photon basées sur des tubes amplificateurs. Le temps d'intégration nécessaire à l'obtention d'un rapport signal sur bruit donné est environ 4 fois moindre qu'avec les anciennes caméras. Les applications d'un tel appareil d'imagerie sont nombreuses: photométrie rapide et faible flux, spectroscopie à haute résolution spectrale et temporelle, imagerie limitée par la diffraction à partir de télescopes terrestres (lucky imaging), etc. D'un point de vue technique, la caméra est dominée par le bruit de Poisson pour les flux lumineux supérieurs à 0.002 photon/pixel/image. D'un autre côté, la raie d'hydrogène neutre (HI) à 21 cm a souvent été utilisée pour étudier la cinématique des galaxies. L'hydrogène neutre a l'avantage de se retrouver en quantité détectable au-delà du disque optique des galaxies. Cependant, la résolution spatiale de ces observations est moindre que leurs équivalents réalisés en lumière visible. Lors de la comparaison des données HI, avec des données à plus haute résolution, certaines différences étaient simplement attribuées à la faible résolution des observations HI. Le projet THINGS (The HI Nearby Galaxy Survey a observé plusieurs galaxies de l'échantillon SINGS (Spitzer Infrared Nearby Galaxies Survey). Les données cinématiques du projet THIGNS seront comparées aux données cinématiques obtenues en lumière Ha, afin de déterminer si la seule différence de résolution spatiale peut expliquer les différences observées. Les résultats montrent que des différences intrinsèques aux traceurs utilisées (hydrogène neutre ou ionisé), sont responsables de dissemblances importantes. La compréhension de ces particularités est importante: la distribution de la matière sombre, dérivée de la rotation des galaxies, est un test de certains modèles cosmologiques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Le but de cette thèse est de raffiner et de mieux comprendre l'utilisation de la méthode spectroscopique, qui compare des spectres visibles de naines blanches à atmosphère riche en hydrogène (DA) à des spectres synthétiques pour en déterminer les paramètres atmosphériques (température effective et gravité de surface). Notre approche repose principalement sur le développement de modèles de spectres améliorés, qui proviennent eux-mêmes de modèles d'atmosphère de naines blanches de type DA. Nous présentons une nouvelle grille de spectres synthétiques de DA avec la première implémentation cohérente de la théorie du gaz non-idéal de Hummer & Mihalas et de la théorie unifiée de l'élargissement Stark de Vidal, Cooper & Smith. Cela permet un traitement adéquat du chevauchement des raies de la série de Balmer, sans la nécessité d'un paramètre libre. Nous montrons que ces spectres améliorés prédisent des gravités de surface qui sont plus stables en fonction de la température effective. Nous étudions ensuite le problème de longue date des gravités élevées pour les DA froides. L'hypothèse de Bergeron et al., selon laquelle les atmosphères sont contaminées par de l'hélium, est confrontée aux observations. À l'aide de spectres haute résolution récoltés au télescope Keck à Hawaii, nous trouvons des limites supérieures sur la quantité d'hélium dans les atmosphères de près de 10 fois moindres que celles requises par le scénario de Bergeron et al. La grille de spectres conçue dans ces travaux est ensuite appliquée à une nouvelle analyse spectroscopique de l'échantillon de DA du SDSS. Notre approche minutieuse permet de définir un échantillon plus propre et d'identifier un nombre important de naines blanches binaires. Nous déterminons qu'une coupure à un rapport signal-sur-bruit S/N > 15 optimise la grandeur et la qualité de l'échantillon pour calculer la masse moyenne, pour laquelle nous trouvons une valeur de 0.613 masse solaire. Finalement, huit nouveaux modèles 3D de naines blanches utilisant un traitement d'hydrodynamique radiative de la convection sont présentés. Nous avons également calculé des modèles avec la même physique, mais avec une traitement standard 1D de la convection avec la théorie de la longueur de mélange. Un analyse différentielle entre ces deux séries de modèles montre que les modèles 3D prédisent des gravités considérablement plus basses. Nous concluons que le problème des gravités élevées dans les naines blanches DA froides est fort probablement causé par une faiblesse dans la théorie de la longueur de mélange.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Nous présentons un relevé et une analyse spectroscopiques de plus de 1300 naines blanches brillantes (V < 17.5) et riches en hydrogène. Des spectres dans le domaine du visible avec un rapport signal-sur-bruit élevé ont été obtenus et les données ont ensuite été analysées avec notre méthode spectroscopique habituelle qui compare les profils observés des raies de Balmer à des spectres synthétiques calculés à partir de la dernière génération de modèles d’atmosphère. D’abord, nous présentons une analyse détaillée de 29 naines blanches de type DAO utilisant une nouvelle grille de modèles qui inclut du carbone, de l’azote et de l’oxygène aux abondances solaires. Nous démontrons que l’ajout de ces métaux dans les modèles d’atmosphère est essentiel pour surmonter le problème des raies de Balmer qui empêche un ajustement simultané de toutes les raies de Balmer avec des paramètres atmosphériques cohérents. Nous identifions également 18 naines blanches chaudes de type DA qui souffrent aussi du problème des raies de Balmer. Des spectres dans l’ultraviolet lointain obtenus des archives du satellite FUSE sont ensuite examinés pour démontrer qu’il existe une corrélation entre les abondances métalliques élevées et les cas du problème des raies de Balmer. Les conséquences de ces résultats pour toutes les naines blanches chaudes et riches en hydrogène sont discutées. En particulier, le scénario évolutif pour les naines blanches DAO est révisé et nous n’avons plus besoin d’évoquer l’évolution post-EHB pour expliquer la majorité des étoiles DAO. Finalement, nous élaborons un scénario dans lequel les métaux engendrent un faible vent stellaire qui expliquerait la présence d’hélium dans les étoiles DAO. Ensuite, nous présentons les résultats globaux de notre relevé, ce qui inclut une analyse spectroscopique de plus de 1200 naines blanches de type DA. En premier lieu, nous présentons le contenu spectroscopique de notre échantillon qui contient de nombreuses classifications erronées ainsi que plusieurs naines blanches de type DAB, DAZ et magnétiques. Nous discutons ensuite des nouveaux modèles d'atmosphère utilisés dans notre analyse. De plus, nous utilisons des modèles de naines M pour obtenir de meilleures valeurs des paramètres atmosphériques pour les naines blanches qui sont membres de systèmes binaires DA+dM. Certaines naines blanches uniques et quelques systèmes binaires double-dégénérées sont également analysés de manière plus détaillée. Nous examinons ensuite les propriétés globales de notre échantillon incluant la distribution de masse et la distribution de masse en fonction de la température. Nous étudions également la façon dont les nouveaux profils de raies de Balmer affectent la détermination des paramètres atmosphériques. Nous testons la précision et la robustesse de nos méthodes en comparant nos résultats avec ceux du projet SPY, dans le cadre duquel plus de 300 des mêmes naines blanches ont été analysées d'une manière complètement indépendante. Finalement, nous faisons un retour sur la bande d'instabilité des naines blanches pulsantes de type ZZ Ceti pour voir quels effets ont les nouveaux profils de raies sur la détermination de ses frontières empiriques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'étude vise à évaluer l'exposition professionnelle au bruit des travailleurs d'une plateforme gazière en Algérie et à mettre en évidence des déterminants influençant cette exposition. Des groupes d'exposition homogène (GEH) ont été constitués sur la base de ressemblances quant à l'exposition au bruit, aux titres d'emploi et aux lieux de travail. Deux stratégies d'échantillonnage ont été suivies, la première selon la norme internationale ISO 9612 : 2009 et la seconde selon la stratégie aléatoire de l'AIHA. Pour les deux approches, les niveaux de bruit (Lex, 8h, niveaux d'exposition au bruit pondéré (A) ajustés à une journée de travail de 8 heures) des opérateurs et des superviseurs étaient généralement > 85 dB(A) alors que pour les techniciens-tableau, les niveaux de bruit (Lex, 8h) étaient en tout temps < 85 dB(A). Pour les trois GEH du titre d'emploi des maintenanciers, il y a eu régulièrement des dépassements de la valeur de référence. Plusieurs travailleurs oeuvrant sur les plateformes gazières sont exposés à des niveaux importants de bruit et sont à risque de développer des problèmes auditifs.