985 resultados para Composite Measurement Scales


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the results of an exploratory study on knowledge management in Portuguese organizations. The study was based on a survey sent to one hundred of the main Portuguese organizations, in order to know their current practices relating knowledge management systems (KMS) usage and intellectual capital (IC) measurement. With this study, we attempted to understand what are the main tools used to support KM processes and activities in the organizations, and what metrics are pointed by organizations to measure their knowledge assets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os osciloscópios digitais são utilizados em diversas áreas do conhecimento, assumindo-se no âmbito da engenharia electrónica, como instrumentos indispensáveis. Graças ao advento das Field Programmable Gate Arrays (FPGAs), os instrumentos de medição reconfiguráveis, dadas as suas vantagens, i.e., altos desempenhos, baixos custos e elevada flexibilidade, são cada vez mais uma alternativa aos instrumentos tradicionalmente usados nos laboratórios. Tendo como objectivo a normalização no acesso e no controlo deste tipo de instrumentos, esta tese descreve o projecto e implementação de um osciloscópio digital reconfigurável baseado na norma IEEE 1451.0. Definido de acordo com uma arquitectura baseada nesta norma, as características do osciloscópio são descritas numa estrutura de dados denominada Transducer Electronic Data Sheet (TEDS), e o seu controlo é efectuado utilizando um conjunto de comandos normalizados. O osciloscópio implementa um conjunto de características e funcionalidades básicas, todas verificadas experimentalmente. Destas, destaca-se uma largura de banda de 575kHz, um intervalo de medição de 0.4V a 2.9V, a possibilidade de se definir um conjunto de escalas horizontais, o nível e declive de sincronismo e o modo de acoplamento com o circuito sob análise. Arquitecturalmente, o osciloscópio é constituído por um módulo especificado com a linguagem de descrição de hardware (HDL, Hardware Description Language) Verilog e por uma interface desenvolvida na linguagem de programação Java®. O módulo é embutido numa FPGA, definindo todo o processamento do osciloscópio. A interface permite o seu controlo e a representação do sinal medido. Durante o projecto foi utilizado um conversor Analógico/Digital (A/D) com uma frequência máxima de amostragem de 1.5MHz e 14 bits de resolução que, devido às suas limitações, obrigaram à implementação de um sistema de interpolação multi-estágio com filtros digitais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A single and practical method to slain Malassezia furfur and Corynebacterium minutissimum in lesions' scales is described. The scales are collected by pressing small pieces of scotch tape (about 4 cm lenght and 2 cm width) onto the lesions and following withdrawl the furfuraceous scales will remain on the glue side. These pieces are then immersed for some minutes in lactophenol-cotton blue stain. Following absorption of the stain the scales are washed in current water to remove the excess of blue stain, dried with filter paper, dehydrated via passage in two bottles containing absolute alcohol and then placed in xylene in a centrifugation tube. The xylene dissolves the scotch tape glue and the scales fall free in the tube. After centrifugation and decantation the scales concentrated on the bottom of the tube are collected with a platinum-loop, placed in Canada balsam on a microscopy slide and closed with a cover slip. The preparations are then ready to be submitted to microscopic examination. Other stains may also be used instead of lactophenol-cotton blue. This method is simple, easily performed, and offers good conditions to study these fungi as well as being useful for the diagnosis of the diseases that they cause.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The most practicable assay for measurement of measles IgG (mIgG) in large numbers of sera is an enzyme immunoassay (EIA). To assess how EIA results would agree with those by the gold standard method of plaque reduction neutralization (PRN) we compared the results from the two methods in 43 pairs of maternal and umbilical cord sera, and sera from the corresponding infants when aged 11 - 14 months. In maternal-cord sera, the differences between mean antibody levels by EIA or PRN were not statistically significant, though in individual sera, differences could be large. However, agreement was less good for infants sera, in which levels of mIgG were very low. The conclusions of a study of transplacental transport of mIgG would not be affected by the use of either technique. When studying waning immunity in infants, PRN should be the method of choice, while results from studies using EIA should be interpreted with caution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the report for Project III of the PhD programme on Technology Assessment and prepared for the Winter School that took place at Universidade Nova de Lisboa, Caparica Campus on the 6th and 7th of December 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As excelentes propriedades mecânicas, associadas ao seu baixo peso, fazem com que os materiais compósitos sejam atualmente dos mais interessantes da nossa sociedade tecnológica. A crescente utilização destes materiais e a excelência dos resultados daí provenientes faz com que estes materiais sejam utilizados em estruturas complexas de responsabilidade, pelo que a sua maquinagem se torna necessária de forma a possibilitar a ligação entre peças. O processo de furação é o mais frequente. O processo de maquinagem de compósitos terá como base os métodos convencionais utilizados nos materiais metálicos. O processo deverá, no entanto, ser convenientemente adaptado, quer a nível de parâmetros, quer a nível de ferramentas a utilizar. As características dos materiais compósitos são bastante particulares pelo que, quando são sujeitos a maquinagem poderão apresentar defeitos tais como delaminação, fissuras intralaminares, arrancamento de fibras ou dano por sobreaquecimento. Para a detecção destes danos, por vezes a inspeção visual não é suficiente, sendo necessário recorrer a processos específicos de análise de danos. Existem já, alguns estudos, cujo âmbito foi a obtenção de furos de qualidade em compósitos, com minimização do dano, não se podendo comparar ainda com a informação existente, no que se refere à maquinagem de materiais metálicos ou ligas metálicas. Desta forma, existe ainda um longo caminho a percorrer, de forma a que o grau de confiança na utilização destes materiais se aproxime aos materiais metálicos. Este trabalho experimental desenvolvido nesta tese assentou essencialmente na furação de placas laminadas e posterior análise dos danos provocados por esta operação. Foi dada especial atenção à medição da delaminação causada pela furação e à resistência mecânica do material após ser maquinado. Os materiais utilizados, para desenvolver este trabalho experimental, foram placas compósitas de carbono/epóxido com duas orientações de fibras diferentes: unidireccionais e em “cross-ply”. Não se conseguiu muita informação, junto do fornecedor, das suas características pelo que se levaram a cabo ensaios que permitiram determinar o seu módulo de elasticidade. Relativamente á sua resistência â tração, como já foi referido, a grande resistência oferecida pelo material, associada às limitações da máquina de ensaios não permitiu chegar a valores conclusivos. Foram usadas três geometrias de ferramenta diferentes: helicoidal, Brad e Step. Os materiais utilizados nas ferramentas, foram o aço rápido (HSS) e o carboneto de tungsténio para as brocas helicoidais de 118º de ângulo de ponta e apenas o carboneto de tungsténio para as brocas Brad e Step. As ferramentas em diamante não foram consideradas neste trabalho, pois, embora sejam reconhecidas as suas boas características para a maquinagem de compósitos, o seu elevado custo não justifica a sua escolha, pelo menos num trabalho académico, como é o caso. As vantagens e desvantagens de cada geometria ou material utilizado foram avaliadas, tanto no que diz respeito à delaminação como á resistência mecânica dos provetes ensaiados. Para a determinação dos valores de delaminação, foi usada a técnica de Raio X. Algum conhecimento já existente relativamente a este processo permitiu definir alguns parâmetros (por exemplo: tempo de exposição das placas ao liquido contrastante), que tornaram acessível o procedimento de obtenção de imagens das placas furadas. Importando estas imagens para um software de desenho (no caso – AutoCad), foi possível medir as áreas delaminadas e chegar a valores para o fator de delaminação de cada furo efetuado. Terminado este processo, todas as placas foram sujeitas a ensaios de esmagamento, de forma a avaliar a forma como os parâmetros de maquinagem afectaram a resistência mecânica do material. De forma resumida, são objetivos deste trabalho: - Caracterizar as condições de corte em materiais compósitos, mais especificamente em fibras de carbono reforçado com matriz epóxida (PRFC); - Caracterização dos danos típicos provocados pela furação destes materiais; - Desenvolvimento de análise não destrutiva (RX) para avaliação dos danos provocados pela furação; - Conhecer modelos existentes com base na mecânica da fratura linear elástica (LEFM); - Definição de conjunto de parâmetros ideais de maquinagem com o fim de minimizar os danos resultantes da mesma, tendo em conta os resultados provenientes dos ensaios de força, da análise não destrutiva e da comparação com modelos de danos existentes e conhecidos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ammonia is an important gas in many power plants and industrial processes so its detection is of extreme importance in environmental monitoring and process control due to its high toxicity. Ammonia’s threshold limit is 25 ppm and the exposure time limit is 8 h, however exposure to 35 ppm is only secure for 10 min. In this work a brief introduction to ammonia aspects are presented, like its physical and chemical properties, the dangers in its manipulation, its ways of production and its sources. The application areas in which ammonia gas detection is important and needed are also referred: environmental gas analysis (e.g. intense farming), automotive-, chemical- and medical industries. In order to monitor ammonia gas in these different areas there are some requirements that must be attended. These requirements determine the choice of sensor and, therefore, several types of sensors with different characteristics were developed, like metal oxides, surface acoustic wave-, catalytic-, and optical sensors, indirect gas analyzers, and conducting polymers. All the sensors types are described, but more attention will be given to polyaniline (PANI), particularly to its characteristics, syntheses, chemical doping processes, deposition methods, transduction modes, and its adhesion to inorganic materials. Besides this, short descriptions of PANI nanostructures, the use of electrospinning in the formation of nanofibers/microfibers, and graphene and its characteristics are included. The created sensor is an instrument that tries to achieve a goal of the medical community in the control of the breath’s ammonia levels being an easy and non-invasive method for diagnostic of kidney malfunction and/or gastric ulcers. For that the device should be capable to detect different levels of ammonia gas concentrations. So, in the present work an ammonia gas sensor was developed using a conductive polymer composite which was immobilized on a carbon transducer surface. The experiments were targeted to ammonia measurements at ppb level. Ammonia gas measurements were carried out in the concentration range from 1 ppb to 500 ppb. A commercial substrate was used; screen-printed carbon electrodes. After adequate surface pre-treatment of the substrate, its electrodes were covered by a nanofibrous polymeric composite. The conducting polyaniline doped with sulfuric acid (H2SO4) was blended with reduced graphene oxide (RGO) obtained by wet chemical synthesis. This composite formed the basis for the formation of nanofibers by electrospinning. Nanofibers will increase the sensitivity of the sensing material. The electrospun PANI-RGO fibers were placed on the substrate and then dried at ambient temperature. Amperometric measurements were performed at different ammonia gas concentrations (1 to 500 ppb). The I-V characteristics were registered and some interfering gases were studied (NO2, ethanol, and acetone). The gas samples were prepared in a custom setup and were diluted with dry nitrogen gas. Electrospun nanofibers of PANI-RGO composite demonstrated an enhancement in NH3 gas detection when comparing with only electrospun PANI nanofibers. Was visible higher range of resistance at concentrations from 1 to 500 ppb. It was also observed that the sensor had stable, reproducible and recoverable properties. Moreover, it had better response and recovery times. The new sensing material of the developed sensor demonstrated to be a good candidate for ammonia gas determination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

XIX Meeting of the Portuguese Electrochemical Society - XVI Iberic Meeting of Electrochemistry

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation for the degree of Doctor of Philosophy in Physics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of solid wastes and natural fibres to the production of innovative composites is now a matter of environmental need. A set of hybrid composites constituted of waste rubber particles and sugarcane bagasse fibres into a thermoset composite material are drilled to determine the effect of rubber particle addition and size, sugarcane fibre addition and length and fibre chemical treatment on damage extension and related mechanical properties. Damage extension is determined by enhanced radiography for further damage measurement – diameter and areas – and correlated with mechanical test results — bearing test. The results demonstrated significant effect of the rubber and fibre additions on mechanical properties of the composites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glass fibre-reinforced plastics (GFRP), nowadays commonly used in the construction, transportation and automobile sectors, have been considered inherently difficult to recycle due to both the cross-linked nature of thermoset resins, which cannot be remoulded, and the complex composition of the composite itself, which includes glass fibres, polymer matrix and different types of inorganic fillers. Hence, to date, most of the thermoset based GFRP waste is being incinerated or landfilled leading to negative environmental impacts and additional costs to producers and suppliers. With an increasing awareness of environmental matters and the subsequent desire to save resources, recycling would convert an expensive waste disposal into a profitable reusable material. In this study, the effect of the incorporation of mechanically recycled GFRP pultrusion wastes on flexural and compressive behaviour of polyester polymer mortars (PM) was assessed. For this purpose, different contents of GFRP recyclates (0%, 4%, 8% and 12%, w/w), with distinct size grades (coarse fibrous mixture and fine powdered mixture), were incorporated into polyester PM as sand aggregates and filler replacements. The effect of the incorporation of a silane coupling agent was also assessed. Experimental results revealed that GFRP waste filled polymer mortars show improved mechanical behaviour over unmodified polyester based mortars, thus indicating the feasibility of GFRP waste reuse as raw material in concrete-polymer composites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent Advances in Mechanics and Materials in Design

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adhesive bonding is an excellent alternative to traditional joining techniques such as welding, mechanical fastening or riveting. However, there are many factors that have to be accounted for during joint design to accurately predict the joint strength. One of these is the adhesive layer thickness (tA). Most of the results are for epoxy structural adhesives, tailored to perform best with small values of tA, and these show that the lap joint strength decreases with increase of tA (the optimum joint strength is usually obtained with tA values between 0.1 and 0.2 mm). Recently, polyurethane adhesives were made available in the market, designed to perform with larger tA values, and whose fracture behaviour is still not studied. In this work, the effect of tA on the tensile fracture toughness (View the MathML source) of a bonded joint is studied, considering a novel high strength and ductile polyurethane adhesive for the automotive industry. This work consists on the fracture characterization of the bond by a conventional and the J-integral techniques, which accurately account for root rotation effects. An optical measurement method is used for the evaluation of crack tip opening (δn) and adherends rotation at the crack tip (θo) during the test, supported by a Matlab® sub-routine for the automated extraction of these parameters. As output of this work, fracture data is provided in traction for the selected adhesive, enabling the subsequent strength prediction of bonded joints.