943 resultados para CT images subject-specific design
Resumo:
The USP General Chapter < 2040 > Disintegration and Dissolution of Dietary Supplements introduced a rupture test as a performance test of soft-shell capsules. Traditionally, the disintegration test was used for determining the disintegration time of all solid oral dosage forms. The aim of this investigation was to investigate differences between the rupture test and the disintegration test using soft-shell capsules. Five different soft-shell capsule products were chosen based on their filling contents and treated to simulate a production deficiency. The study design compared capsules as received with capsules that were treated by coating them with the liquid contents of another capsule. The capsules were incubated at room temperature and at 40 degrees C. The tests were repeated after two weeks, and at each time point, twelve capsules of each product were tested using the rupture and the disintegration tests. Six capsules were tested untreated, while the other six capsules were treated. Rupture and disintegration times were recorded as dependent variables in each experiment. Thedata were analyzed using ANOVA. According to the USP definition for disintegration, the rupture of a soft-shell capsule can be seen as fulfilling the disintegration criterion if the capsule contents is a semisolid or liquid. Statistical analysis showed no advantage of the rupture test over the disintegration test. On a product-by-product basis, both tests were sensitive to certain investigated parameters. A noticeable difference between both tests was that in most cases, the rupture test reached the defined endpoint faster than the disintegration test. Soft-shell capsules that are subject to a Quality by Design approach should be tested with both methods to determine which performance test is the most appropriate test for a specific product.
Resumo:
Bulk density of undisturbed soil samples can be measured using computed tomography (CT) techniques with a spatial resolution of about 1 mm. However, this technique may not be readily accessible. On the other hand, x-ray radiographs have only been considered as qualitative images to describe morphological features. A calibration procedure was set up to generate two-dimensional, high-resolution bulk density images from x-ray radiographs made with a conventional x-ray diffraction apparatus. Test bricks were made to assess the accuracy of the method. Slices of impregnated soil samples were made using hardsetting seedbeds that had been gamma scanned at 5-mm depth increments in a previous study. The calibration procedure involved three stages: (i) calibration of the image grey levels in terms of glass thickness using a staircase made from glass cover slips, (ii) measurement of ratio between the soil and resin mass attenuation coefficients and the glass mass attenuation coefficient, using compacted bricks of known thickness and bulk density, and (iii) image correction accounting for the heterogeneity of the irradiation field. The procedure was simple, rapid, and the equipment was easily accessible. The accuracy of the bulk density determination was good (mean relative error 0.015), The bulk density images showed a good spatial resolution, so that many structural details could be observed. The depth functions were consistent with both the global shrinkage and the gamma probe data previously obtained. The suggested method would be easily applied to the new fuzzy set approach of soil structure, which requires generation of bulk density images. Also, it would be an invaluable tool for studies requiring high-resolution bulk density measurement, such as studies on soil surface crusts.
Resumo:
Frequency, recency, and type of prior exposure to very low-and high-frequency words were manipulated in a 3-phase (i.e., familiarization training, study, and test) design. Increasing the frequency with which a definition for a very low-frequency word was provided during familiarization facilitated the word's recognition in both yes-no (Experiment 1) and forced-choice paradigms (Experiment 2). Recognition of very low-frequency words not accompanied by a definition during familiarization first increased, then decreased as familiarization frequency increased (Experiment I). Reasons for these differences were investigated in Experiment 3 using judgments of recency and frequency. Results suggested that prior familiarization of a very low-frequency word with its definition may allow a more adequate episodic representation of the word to be formed during a subsequent study trial. Theoretical implications of these results for current models of memory are discussed.
Resumo:
Many species of stomatopod crustaceans have multiple spectral classes of photoreceptors in their retinas. Behavioral evidence also indicates that stomatopods are capable of discriminating objects by their spectral differences alone, Most animals use only two to four different types of photoreceptors in their color vision systems, typically with broad sensitivity functions, but the stomatopods apparently include eight or more narrowband photoreceptor classes for color recognition. It is also known that stomatopods use several colored body regions in social interactions. To examine why stomatopods may be so 'concerned' with color, we measured the absorption spectra of visual pigments and intrarhabdomal filters, and the reflectance spectra from different parts of the bodies of several individuals of the gonodactyloid stomatopod species, Gonodactylus smithii. We then applied a model of multiple dichromatic channels for color encoding to examine whether the finely tuned color vision was specifically co-evolved with their complex color signals. Although the eye design of stomatopods seems suitable for detecting color signals of their own, the detection of color signals from other animals, such as reef fishes, can be enhanced as well. Color vision in G. smithii is therefore not exclusively adapted to detect its own color signals, but the spectral tuning of some photoreceptors (e.g. midband Rows 2 and 3) enhances the contrast of certain color signals to a large enough degree to make co-evolution between color vision and these rather specific color signals likely. Copyright (C) 2000 S. Karger AG, Basel.
Resumo:
This paper presents a numerical technique for the design of an RF coil for asymmetric magnetic resonance imaging (MRI) systems. The formulation is based on an inverse approach where the cylindrical surface currents are expressed in terms of a combination of sub-domain basis functions: triangular and pulse functions. With the homogeneous transverse magnetic field specified in a spherical region, a functional method is applied to obtain the unknown current coefficients. The current distribution is then transformed to a conductor pattern by use of a stream function technique. Preliminary MR images acquired using a prototype RF coil are presented and validate the design method. (C) 2002 Elsevier Science B.V. All rights reserved.
Resumo:
Purpose - The purpose of this paper is to provide a framework for radio frequency identification (RFID) technology adoption considering company size and five dimensions of analysis: RFID applications, expected benefits business drivers or motivations barriers and inhibitors, and organizational factors. Design/methodology/approach - A framework for RFID adoption derived from literature and the practical experience on the subject is developed. This framework provides a conceptual basis for analyzing a survey conducted with 114 companies in Brazil. Findings - Many companies have been developing RFID initiatives in order to identify potential applications and map benefits associated with their implementation. The survey highlights the importance business drivers in the RFID implementation stage, and that companies implement RFID focusing on a few specific applications. However, there is a weak association between expected benefits and business challenges with the current level of RFID technology adoption in Brazil. Research limitations/implications - The paper is not exhaustive, since RFID adoption in Brazil is at early stages during the survey timeline. Originality/value - The main contribution of the paper is that it yields a framework for analyzing RFID technology adoption. The authors use this framework to analyze RFID adoption in Brazil, which proved to be a useful one for identifying key issues for technology adoption. The paper is useful to any researchers or practitioners who are focused on technology adoption, in particular, RFID technology.
Resumo:
A long-standing challenge of content-based image retrieval (CBIR) systems is the definition of a suitable distance function to measure the similarity between images in an application context which complies with the human perception of similarity. In this paper, we present a new family of distance functions, called attribute concurrence influence distances (AID), which serve to retrieve images by similarity. These distances address an important aspect of the psychophysical notion of similarity in comparisons of images: the effect of concurrent variations in the values of different image attributes. The AID functions allow for comparisons of feature vectors by choosing one of two parameterized expressions: one targeting weak attribute concurrence influence and the other for strong concurrence influence. This paper presents the mathematical definition and implementation of the AID family for a two-dimensional feature space and its extension to any dimension. The composition of the AID family with L (p) distance family is considered to propose a procedure to determine the best distance for a specific application. Experimental results involving several sets of medical images demonstrate that, taking as reference the perception of the specialist in the field (radiologist), the AID functions perform better than the general distance functions commonly used in CBIR.
Resumo:
Background: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. Methods: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. Results: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. Conclusions: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.).
Resumo:
Recent studies have demonstrated that spatial patterns of fMRI BOLD activity distribution over the brain may be used to classify different groups or mental states. These studies are based on the application of advanced pattern recognition approaches and multivariate statistical classifiers. Most published articles in this field are focused on improving the accuracy rates and many approaches have been proposed to accomplish this task. Nevertheless, a point inherent to most machine learning methods (and still relatively unexplored in neuroimaging) is how the discriminative information can be used to characterize groups and their differences. In this work, we introduce the Maximum Uncertainty Linear Discrimination Analysis (MLDA) and show how it can be applied to infer groups` patterns by discriminant hyperplane navigation. In addition, we show that it naturally defines a behavioral score, i.e., an index quantifying the distance between the states of a subject from predefined groups. We validate and illustrate this approach using a motor block design fMRI experiment data with 35 subjects. (C) 2008 Elsevier Inc. All rights reserved.
Resumo:
P>Context We previously described a six-generation family with G533C RET mutation and medullary thyroid carcinoma, in the largest family reported do date. Of particular interest, phenotype variability regarding the age of onset and clinical presentation of the disease, was observed. Objective We evaluate whether single SNPs within RET oncogene or haplotype comprising the RET variants (defined by Haploview) could predispose to early development of MTC in this family and influence the clinical manifestation. Design Eight SNPs were selected based on their previous association with the clinical course of hereditary or sporadic MTC, in particular promoting an early onset of disease. The variants were initially tested in 77 G533C-carriers and 100 controls using either PCR-direct sequencing or PCR-RFLP. Association between a SNP or haplotype and age at diagnosis or presence of lymph node metastasis was tested in 34 G533C-carries with MTC. Different bioinformatic tools were used to evaluate the potential effects on RNA splicing. Results An association was found between IVS1-126G > T and age at diagnosis. The variant [IVS8 +82A > G; 85-86 insC] was associated with the presence of lymph node metastases at diagnosis. In silico analysis suggested that this variant may induce abnormal splicing. This in silico analysis predicted that the [IVS8 +82A > G; 85-86 insC] could alter the splicing by disrupting and/or creating exonic splicing enhancer motifs. Conclusions We here identified two RET variants that were associated with phenotype variability in G533C-carriers, which highlights the fact that the modifier effect of a variant might depend on the type of mutation.
Resumo:
BACKGROUND CONTEXT: The vertebral spine angle in the frontal plane is an important parameter in the assessment of scoliosis and may be obtained from panoramic X-ray images. Technological advances have allowed for an increased use of digital X-ray images in clinical practice. PURPOSE: In this context, the objective of this study is to assess the reliability of computer-assisted Cobb angle measurements taken from digital X-ray images. STUDY DESIGN/SETTING: Clinical investigation quantifying scoliotic deformity with Cobb method to evaluate the intra- and interobserver variability using manual and digital techniques. PATIENT SAMPLE: Forty-nine patients diagnosed with idiopathic scoliosis were chosen based on convenience, without predilection for gender, age, type, location, or magnitude of the curvature. OUTCOME MEASURES: Images were examined to evaluate Cobb angle variability, end plate selection, as well as intra- and interobserver errors. METHODS: Specific software was developed to digitally reproduce the Cobb method and calculate semiautomatically the degree of scoliotic deformity. During the study, three observers estimated the Cobb angle using both the digital and the traditional manual methods. RESULTS: The results showed that Cobb angle measurements may be reproduced in the computer as reliably as with the traditional manual method, in similar conditions to those found in clinical practice. CONCLUSIONS: The computer-assisted method (digital method) is clinically advantageous and appropriate to assess the scoliotic curvature in the frontal plane using Cobb method. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
Background: Pain and anxiety are a common problem in all recovery phases after a burn. The Burns Specific Pain Anxiety Scale (BSPAS) was proposed to assess anxiety in burn patients related to painful procedures. Objectives: To assess internal consistency, discriminative construct validity, dimensionality and convergent construct validity of the Brazilian-Portuguese version of the Burns Specific Pain Anxiety Scale. Design: In this cross-sectional study, the original version of the BSPAS, adapted into Brazilian Portuguese, was tested for internal consistency (Cronbach`s Alpha), discriminative validity (related to total body surface area burned and sex), dimensionality (through factor analysis), and convergent construct validity (applying the Visual Analogue Scale for pain and State-Anxiety-STAI) in a group of 91 adult burn patients. Results: The adapted version of the BSPAS displayed a moderate and positive correlation with pain assessments: immediately before baths and dressings (r = 0.32; p < 0.001), immediately after baths and dressings (r = 0.31; p < 0.001) and during the relaxation period (r= 0.31; p < 0.001) and with anxiety assessments (r = 0.34; p < 0.001). No statistically significant differences were observed when comparing the mean of the adapted version of the BSPAS scores with sex (p = 0.194) and total body surface area burned (p = 0.162) (discriminative validity). The principal components analysis applied to our sample seems to confirm anxiety as one single domain of the Brazilian-Portuguese version of the BSPAS. Cronbach`s Alpha showed high internal consistency of the adapted version of the scale (0.90). Conclusion: The Brazilian-Portuguese version of the BSPAS 9-items has shown statically acceptable levels of reliability and validity for pain-related anxiety evaluation in burn patients. This scale can be used to assess nursing interventions aimed at decreasing pain and anxiety related to the performance of painful procedures. (c) 2010 Elsevier Ltd. All rights reserved.