693 resultados para CRANIOFACIAL DYSOSTOSIS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of modern odontology is to reconstitute to the patient the comfort, the function, the aesthetic form, the phonetic capability, and normal health. However, the more the patient is toothless, the more this objective becomes difficult inside traditional dentistry. As a result of continuous research of materials and techniques, permissible success is now a reality, whitewashing many challenging clinical situations. Thus, the objective of the article was to present a clinical case where association of the universal cast to long abutment pillars and EsthetiCone were used for aesthetic whitewashing. A man presented to the clinic of the Faculty of Dentistry, Universidade Estadual Paulista. After clinical examination and radiographic evaluation evidenced the necessity of substitution of fixed prostheses (15-25), he was presented with disadaptation and a favorable aesthetic solution. Ahead of the evaluated picture and considering the extension of the toothless space made, it was opted more, to the accomplishment of surgery, the setting of 2 implantations in the region and 2 in each edentate side of the posterior portion of the jaw. On 6 implants and 2 teeth, 10 metal ceramic crowns had been confectioned: 4 of them being joined in the region of the 12 to the 22 and the other 6 as unit crowns in the region of the 13, the 14, the 15, the 23, the 24, and the 25. The carried-through treatment was capable to return the aesthetic form, the function, the phonetic capability, the comfort, and the health of the verbal socket.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New strategies to fulfill craniofacial bone defects have gained attention in recent years due to the morbidity of autologous bone graft harvesting. We aimed to evaluate the in vivo efficacy of bone tissue engineering strategy using mesenchymal stem cells associated with two matrices (bovine bone mineral and α-tricalcium phosphate), compared to an autologous bone transfer. A total of 28 adult, male, non-immunosuppressed Wistar rats underwent a critical-sized osseous defect of 5 mm diameter in the alveolar region. Animals were divided into five groups. Group 1 (n = 7) defects were repaired with autogenous bone grafts; Group 2 (n = 5) defects were repaired with bovine bone mineral free of cells; Group 3 (n = 5) defects were repaired with bovine bone mineral loaded with mesenchymal stem cells; Group 4 (n = 5) defects were repaired with α-tricalcium phosphate free of cells; and Group 5 (n = 6) defects were repaired with α-tricalcium phosphate loaded with mesenchymal stem cells. Groups 2-5 were compared to Group 1, the reference group. Healing response was evaluated by histomorphometry and computerized tomography. Histomorphometrically, Group 1 showed 60.27% ± 16.13% of bone in the defect. Groups 2 and 3 showed 23.02% ± 8.6% (p = 0.01) and 38.35% ± 19.59% (p = 0.06) of bone in the defect, respectively. Groups 4 and 5 showed 51.48% ± 11.7% (p = 0.30) and 61.80% ± 2.14% (p = 0.88) of bone in the defect, respectively. Animals whose bone defects were repaired with α-tricalcium phosphate and mesenchymal stem cells presented the highest bone volume filling the defects; both were not statistically different from autogenous bone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The blowout fractures may be classified as pure or impure depending on the associated structures. There are 2 main theories attempting to describe the mechanism of injury, the hydraulic, and blocking mechanism. The complications of this type of fracture may involve diplopia, enophthalmos, and ocular movement restriction. Several materials are available for the reconstruction of orbital floor, including the titanium mesh, which present great properties, such as easy modeling and stabilization, small thickness, and shape maintenance. There, however, are disadvantages such as the possibility of adherence formation. The aim of this report is to describe the case of a patient with an 8-month blowout fracture sequel, presenting extensive enophthalmos and treated by affixing a titanium mesh associated with bovine pericardium membrane in the orbital floor. Therefore, based on a 2-year follow-up, it was possible to observe how effective the association between these 2 materials in solving the case was.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nasal obstruction (NO) is a common symptom present in 25% of the general population, which significantly interferes with the quality of life. The different facial profiles and malocclusion patterns could be associated with the degree of NO. In order to evaluate the nasal function in patients with different facial morphology patterns, the authors developed a prospective study in which 88 patients from a dentofacial deformities center were included. These patients were submitted to fibrorhinoscopy (Mashida, ENT PIII) with a 3.2-mm cannula under topical anesthesia to evaluate septal deviation, inferior and medium turbinates, and pharyngeal tonsils. The 88 patients included in the study were divided into 3 groups according to the classification of the facial profile, distributed as follows: 32 class I, 28 class II, and 28 class III; the data collected was statistically analyzed by analysis of variance and the results are shown. The patients included in this study presented similar prevalence of NO with the reduction of airway function efficiency. Although it was not a statistically different, the group II presented higher mean Nasal Obstruction Syndrome Evaluation scores.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Increase in lower anterior crowding is a general problem among adult Caucasians. The tooth movement responsible for this phenomenon, however, is not fully elucidated. Aim of this study was to describe signs of ongoing tooth movement reflected in the thickness of the bundle bone around mandibular teeth and the distribution of eroding surfaces of the alveolar wall in human autopsy material. The distribution of bundle bone and eroding surfaces was assessed histomorphometrically on 106 mandibular teeth, and the surrounding bone obtained at autopsy from 35 deceased persons ranging from 19 to 55 years of age. By examining the mesio-distal and bucco-lingual aspects at the cervical and apical levels of the roots, a pattern of tooth movements could be established. The distribution of the bundle bone thickness and the vectors of eroding surfaces enabled the direction of tooth movement to be reconstructed. Mesial and lingual displacement was prevalent for the anterior teeth. The signs of ongoing displacement of lower teeth support the concept of crowding occurring in adult individuals and support the maintenance of retainers, even following cessation of growth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract: The intraoral approach to zygomatic fracture treatment was introduced by Keen in 1909. This technique allows both an adequate visualization of the zygomaticomaxillary buttress and intraoral reduction of zygomatic arch fractures. Similar techniques have been published over the last 30 years. The aim of this study was to describe a modification of the Keen technique that promotes adequate visualization of the infraorbital rim and permits reduction and fixation of this region in cases of zygomatic fractures. The present technique has several advantages such as that (a) only 1 incision is necessary to approach the zygomaticomaxillary buttress and infraorbital rim, (b) it optimizes surgical time, and (c) it avoids periorbital scars. Fracture of the zygomatic complex is one of the most common facial traumas and has been extensively described in the literature.1 However, there are several controversies as regards the best technique and treatment of these fractures, such as closed versus open reduction; sequence of reduction and fixation in open techniques; complications; and morbidity rates of each technique. Currently, the intraoral approach for surgical treatment of zygomatic complex fractures has received special attention. It was first described by Keen in 1909, using the upper sulcus technique. Later, other studies showed different variations of this technique to reach the zygomatic arch and buttress.3,4 However, in most cases, infraorbital margin fixation was still performed through the subtarsal, subciliary, or transconjunctival approach. The purpose of this article was to describe the modifications made to the intraoral approach to allow reduction and fixation of the infraorbital rim in zygomatic fractures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The maxillofacial prosthetic rehabilitation aims of individuals with craniofacial deformities resulting from trauma, congenital malformations or tumors. Many researches have been done to improve the stability and retention of dentures in patients. With the advent of osseointegration, the maxillofacial prosthesis suffered a major advance making possible the realization of prosthetic works with stability, aesthetic quality and predictable results. This paper reviews the literature regarding the use of zygomatic implants in the fixation of maxillofacial prostheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: In view of reports in the literature on the benefits achieved with the use of platform switching, described as the use of an implant with a larger diameter than the abutment diameter, the goal being to prevent the (previously) normal bone loss down to the first thread that occurs around most implants, thus enhancing soft tissue aesthetics and stability and the need for implant inclination due to bone anatomy in some cases, the aim of this study was to evaluate bone stress distribution on peri-implant bone, by using three-dimensional finite element analysis to simulate the influence of implants with different abutment angulations (0 and 15 degrees) in platform switching. METHODS: Four mathematical models of an implant-supported central incisor were created with varying abutment angulations: straight abutment (S1 and S2) and angulated abutment at 15 degrees (A1 and A2), submitted to 2 loading conditions (100 N): S1 and A1-oblique loading (45 degrees) and S2 and A2-axial loading, parallel to the long axis of the implant. Maximum (σmax) and minimum (σmin) principal stress values were obtained for cortical and trabecular bone. RESULTS: Models S1 and A1 showed higher σmax in cortical and trabecular bone when compared with S2 and A2. The highest σmax values (in MPa) in the cortical bone were found in S1 (28.5), followed by A1 (25.7), S2 (11.6), and A2 (5.15). For the trabecular bone, the highest σmax values were found in S1 (7.53), followed by A1 (2.87), S2 (2.85), and A2 (1.47). CONCLUSIONS: Implants with straight abutments generated the highest stress values in bone. In addition, this effect was potentiated when the load was applied obliquely.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the opacity of the polymethylmethacrylate for ocular prosthesis using an ocular button, a colorless resin for the ocular prostheses, and 4 brands of acrylic colorless resin in the function of weathering (0, 504, or 1008 h) and thickness (1 and 3.5 mm). One hundred twenty specimens were confectioned (made) and allocated into 12 groups (n = 10). Opacity analysis was carried out with a spectrophotometer of visible ultraviolet reflection before and after weathering by 504 and 1008 hours. Data for the opacity were expressed in ΔE. Data were then analyzed statistically by analysis of variance and the Tukey test (P < 0.01). The data demonstrated statistically significant differences; manufactured ocular button (ΔE = 47.4) and the resin Vipi Cril (ΔE = 38.11) presented greater and minor values of opacity, respectively. The weathering showed statistical difference among times (0 h, ΔE = 36.32; 504 h, ΔE = 39.98; and 1008 h, ΔE = 43.9). Ocular button and evaluated resins presented greater values of opacity when presented in 3.5 mm in thickness. The values of opacity increased with the progression of the time of weathering, independent of the evaluated material and the thickness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The failure of facial prostheses is caused by limitations in the properties of existing materials, especially flexibility and durability. Therefore, this study evaluated the marginal deterioration of a silicone used for fabrication of facial prostheses (Silastic MDX4-4210, Dow Corning Corporation, Midland, MI, USA) according to the influence of artificial aging, daily disinfection, and 2 types of pigmentation. Thirty specimens were fabricated and subdivided in 6 groups: without pigmentation, pigmented with make-up powder and iron oxide, and evaluated with and without the action of the disinfectant. Analysis of marginal deterioration was performed on a scanning electron microscope (magnification, ×5000) immediately 6 months and 1 year after fabrication of specimens, following the guidelines of ASTM International. After visual analysis of the photomicrographs, it was noticed that all groups presented marginal deterioration and alterations in surface texture with time. The use of disinfection did not contribute to the marginal deterioration of polymer (silicone), regardless of the pigmentation and artificial aging.