995 resultados para Atomic Displacement Parameters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the last century, numerous techniques have been developed to analyze the movement of humans while walking and running. The combined use of kinematics and kinetics methods, mainly based on high speed video analysis and forceplate, have permitted a comprehensive description of locomotion process in terms of energetics and biomechanics. While the different phases of a single gait cycle are well understood, there is an increasing interest to know how the neuro-motor system controls gait form stride to stride. Indeed, it was observed that neurodegenerative diseases and aging could impact gait stability and gait parameters steadiness. From both clinical and fundamental research perspectives, there is therefore a need to develop techniques to accurately track gait parameters stride-by-stride over a long period with minimal constraints to patients. In this context, high accuracy satellite positioning can provide an alternative tool to monitor outdoor walking. Indeed, the high-end GPS receivers provide centimeter accuracy positioning with 5-20 Hz sampling rate: this allows the stride-by-stride assessment of a number of basic gait parameters--such as walking speed, step length and step frequency--that can be tracked over several thousand consecutive strides in free-living conditions. Furthermore, long-range correlations and fractal-like pattern was observed in those time series. As compared to other classical methods, GPS seems a promising technology in the field of gait variability analysis. However, relative high complexity and expensiveness--combined with a usability which requires further improvement--remain obstacles to the full development of the GPS technology in human applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Colonoscopy is generally performed with the patient sedated and receiving analgesics. However, the benefit of the most often used combination of intravenous midazolam and pethidine on patient tolerance and pain and its cardiorespiratory risk have not been fully defined. METHODS: In this double-blind prospective study, 150 outpatients undergoing routine colonoscopy were randomly assigned to receive either (1) low-dose midazolam (35 micrograms/kg) and pethidine (700 micrograms/kg in 48 patients, 500 micrograms/kg in 102 patients), (2) midazolam and placebo pethidine, or (3) pethidine and placebo midazolam. RESULTS: Tolerance (visual analog scale, 0 to 100 points: 0 = excellent; 100 = unbearable) did not improve significantly more in group 1 compared with group 2 (7 points; 95% confidence interval [-2-17]) and group 3 (2 points; 95% confidence interval [-7-12]). Similarly, pain was not significantly improved in group 1 as compared with the other groups. Male gender (p < 0.001) and shorter duration of the procedure (p = 0.004), but not amnesia, were associated with better patient tolerance and less pain. Patient satisfaction was similar in all groups. Oxygen desaturation and hypotension occurred in 33% and 11%, respectively, with a similar frequency in all three groups. CONCLUSIONS: In this study, the combination of low-dose midazolam and pethidine does not improve patient tolerance and lessen pain during colonoscopy as compared with either drug given alone. When applying low-dose midazolam, oxygen desaturation and hypotension do not occur more often after combined use of both drugs. For the individual patient, sedation and analgesia should be based on the endoscopist's clinical judgement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the power of various parameters of the vestibulo-ocular reflex (VOR) in detecting unilateral peripheral vestibular dysfunction and in characterizing certain inner ear pathologies. STUDY DESIGN: Prospective study of consecutive ambulatory patients presenting with acute onset of peripheral vertigo and spontaneous nystagmus. SETTING: Tertiary referral center. PATIENTS: Seventy-four patients (40 females, 34 males) and 22 normal subjects (11 females, 11 males) were included in the study. Patients were classified in three main diagnoses: vestibular neuritis: 40; viral labyrinthitis: 22; Meniere's disease: 12. METHODS: The VOR function was evaluated by standard caloric and impulse rotary tests (velocity step). A mathematical model of vestibular function was used to characterize the VOR response to rotational stimulation. The diagnostic value of the different VOR parameters was assessed by uni- and multivariable logistic regression. RESULTS: In univariable analysis, caloric asymmetry emerged as the most powerful VOR parameter in identifying unilateral vestibular deficit, with a boundary limit set at 20%. In multivariable analysis, the combination of caloric asymmetry and rotational time constant asymmetry significantly improved the discriminatory power over caloric alone (p&lt;0.0001) and produced a detection score with a correct classification of 92.4%. In discriminating labyrinthine diseases, different combinations of the VOR parameters were obtained for each diagnosis (p&lt;0.003) supporting that the VOR characteristics differ between the three inner ear disorders. However, the clinical usefulness of these characteristics in separating the pathologies was limited. CONCLUSION: We propose a powerful logistic model combining the indices of caloric and time constant asymmetries to detect a peripheral vestibular loss, with an accuracy of 92.4%. Based on vestibular data only, the discrimination between the different inner ear diseases is statistically possible, which supports different pathophysiologic changes in labyrinthine pathologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

uvby H-beta photometry has been obtained for a sample of 93 selected main sequence A stars. The purpose was to determine accurate effective temperatures, surface gravities, and absolute magnitudes for an individual determination of ages and parallaxes, which have to be included in a more extensive work analyzing the kinematic properties of A V stars. Several calibrations and methods to determine the above mentioned parameters have been reviewed, allowing the design of a new algorithm for their determination. The results obtained using this procedure were tested in a previous paper using uvby H-beta data from the Hauck and Mermilliod catalogue, and comparing the rusulting temperatures, surface gravities and absolute magnitudes with empirical determinations of these parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Ravihevosten jalostettavia ominaisuuksia kuvaavien kilpailumittojen perinnölliset tunnusluvut

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Sian kasvuominaisuuksien perinnölliset tunnusluvut arvioituna kolmannen asteen polynomifunktion avulla

Relevância:

20.00% 20.00%

Publicador:

Resumo:

subsequent extension-induced exhumation. Geochronological dating of various Structural, thermobarometric, and geochronological data place limits on the age and tectonic displacement along the Zanskar shear zone, a major north-dipping synorogenic extensional structure separating the high-grade metamorphic sequence of the High Himalayan Crystalline Sequence from the overlying low-grade sedimentary rocks of the Tethyan Himalaya, A complete Barrovian metamorphic succession, from kyanite to biotite zone mineral assemblages, occurs within the I-km-thick Zanskar shear zone. Thermobarometric data indicate a difference In equilibration depths of 12 +/- 3 km between the lower kyanite zone and the garnet zone, which is Interpreted as a minimum estimate for the finite vertical displacement accommodated by the Zanskar shear zone. For the present-day dip of the structure (20 degrees), a simple geometrical model shows that a net slip of 35 +/- 9 km is required to regroup these samples to the same structural level. Because the kyanite to garnet zone rocks represent only part of the Zanskar shear zone, and because its original dip may have been less than the present-day dip, these estimates fur the finite displacement represent minimum values. Field relations and petrographic data suggest that migmatization and associated leucogranite intrusion in the footwall of the Zanskar shear zone occurred as a continuous profess starting at the Barrovian metamorphic peak and lasting throughout the subsequent extension-induced exhumation. Geochronological dataing of various leucogranitic plutons and dikes in the Zanskar shear zone footwall indicates that the main ductile shearing along the structure ended by 19.8 Ma and that extension most likely initiated shortly before 22.2 Ma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performing a complete blood count analysis is a daily routine necessary for a good care of patients. Nowadays, modern blood analyzers provide on top of classical blood values, several additional parameters. In this paper, using short case presentations, we discuss how to interpret these results and integrate them in the clinical context.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Developing a novel technique for the efficient, noninvasive clinical evaluation of bone microarchitecture remains both crucial and challenging. The trabecular bone score (TBS) is a new gray-level texture measurement that is applicable to dual-energy X-ray absorptiometry (DXA) images. Significant correlations between TBS and standard 3-dimensional (3D) parameters of bone microarchitecture have been obtained using a numerical simulation approach. The main objective of this study was to empirically evaluate such correlations in anteroposterior spine DXA images. Thirty dried human cadaver vertebrae were evaluated. Micro-computed tomography acquisitions of the bone pieces were obtained at an isotropic resolution of 93μm. Standard parameters of bone microarchitecture were evaluated in a defined region within the vertebral body, excluding cortical bone. The bone pieces were measured on a Prodigy DXA system (GE Medical-Lunar, Madison, WI), using a custom-made positioning device and experimental setup. Significant correlations were detected between TBS and 3D parameters of bone microarchitecture, mostly independent of any correlation between TBS and bone mineral density (BMD). The greatest correlation was between TBS and connectivity density, with TBS explaining roughly 67.2% of the variance. Based on multivariate linear regression modeling, we have established a model to allow for the interpretation of the relationship between TBS and 3D bone microarchitecture parameters. This model indicates that TBS adds greater value and power of differentiation between samples with similar BMDs but different bone microarchitectures. It has been shown that it is possible to estimate bone microarchitecture status derived from DXA imaging using TBS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we demonstrate that conductive atomic force microscopy (C-AFM) is a very powerful tool to investigate, at the nanoscale, metal-oxide-semiconductor structures with silicon nanocrystals (Si-nc) embedded in the gate oxide as memory devices. The high lateral resolution of this technique allows us to study extremely small areas ( ~ 300nm2) and, therefore, the electrical properties of a reduced number of Si-nc. C-AFM experiments have demonstrated that Si-nc enhance the gate oxide electrical conduction due to trap-assisted tunneling. On the other hand, Si-nc can act as trapping centers. The amount of charge stored in Si-nc has been estimated through the change induced in the barrier height measured from the I-V characteristics. The results show that only ~ 20% of the Si-nc are charged, demonstrating that the electrical behavior at the nanoscale is consistent with the macroscopic characterization.