602 resultados para Aparelhos ortodônticos removíveis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A large number of metal alloys are used in Dentistry for the manufacture of fixed and removable dentures. In the oral cavity, these structures are exposed to a chemically aggressive medium, like saliva and mechanical efforts, like mastication. In addition, acidic solutions containing fluoride ions are also frequently used in dental treatments to prevent dental plates and decays development. In this context, it was considered important to investigate the influence that a fourth element could exert when added to the ternary alloy Ni-Cr-Mo, largely used in Brazil. Therefore, electrochemical tests were done to evaluate the resistance to corrosion of quaternary alloy 65Ni-25Cr-5Mo-5Ta and 65Ni-25Cr-5Mo-5W in NaF solution 0,08mol / L, pH = 4.7. For greater understanding the microstructure and morphology of alloys were studied, through metallographic analysis, using optics microscopy and electron microscopy scanning. For the electrochemical tests were applied techniques traditionally used in corrosion researches, such as: potential measures in open circuit (OCP) and cyclic polarization (CP). It was found that both quaternary alloys showed very similar results. Comparing these quaternary alloys with the ternary 65Ni-25Cr-10Mo, it was found that the quaternary alloys exhibit greater resistance to corrosion, in other words, less passivation current density than the ternary alloy, showing that it is advantageous to add a fourth element in the alloy

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Being the hydrotherapy a treatment in water of great importance for children and adults with motor disability, providing safety and comfort is a very important task that is difficult to health professional without the aid of some specialized equipment. Generally imported devices are used for such purposes, these highly complex apparatus have a high cost and limit the patient's movement in water and exercise possibilities in some cases. In this work a solution will be presented to replace such equipment, using catalogs and computer modeling a prototype will be studied and new equipment will be developed to assist entry into the pool and it would also allow mobility to the patient in an aqueous medium. This safely mobility in the water increase the possibilities of exercises and the accessories founded in commercial catalogs make this project feasible from an economic aspect

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a study based on bibliographic research on LTE technology, chosen for the fourth generation of mobile phones, and the current status of implementation of 4G network in Brazil. The change in user behavior, which now uses data over the voice services, requires transmission networks to be increasingly robust and fast to enable the viewing of videos and use of other platforms that require internet connection. The retrospective of the development of mobile technologies, from 1G up to 4G that is currently used, shows the long road until it came to appliances and how the phone is used nowadays. Finally, the popularity of smartphones and hence the growing number of people with access to 4G networks, demanded new researchs for the development of future generations technologies in order to achieve the demand for speed enabling significant changes in user experience

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The product development field daily works in the chase of new materials and technologies that fulfills the requirements of the consumer market. So, projects are developed in order to theoretically predict what will actually happen. The production of household appliance is not different. To provide a pleasant bath to the costumer, the manufacture of a bathtub counts on many components. With this in mind, this work goal is to study the possibility of production by plastic injection of the assembly water source/overflow pipe used in bathtubs and compare its production cost with the cost of the assembly acquired from third parties. The injection process is widely used on the world stage because of its numerous advantages, however, due to the high cost of the molds, it is important to estimate the time required for the return of the initial investment. To do this, a model was designed to examine its dimensions and then initiate the study of the possibility to inject the components with the available injection machine and the production cycle. With the results, it was found that there was a reduction in the cost of the finished assembly, but a very long time to return the initial investment due to the current financial scenery of the country

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the retinal nerve fiber layer measurements with time-domain (TD) and spectral-domain (SD) optical coherence tomography (OCT), and to test the diagnostic ability of both technologies in glaucomatous patients with asymmetric visual hemifield loss. Methods: 36 patients with primary open-angle glaucoma with visual field loss in one hemifield (affected) and absent loss in the other (non-affected), and 36 age-matched healthy controls had the study eye imaged with Stratus-OCT (Carl Zeiss Meditec Inc., Dublin, California, USA) and 3 D OCT-1000 (Topcon, Tokyo, Japan). Peripapillary retinal nerve fiber layer measurements and normative classification were recorded. Total deviation values were averaged in each hemifield (hemifield mean deviation) for each subject. Visual field and retinal nerve fiber layer "asymmetry indexes" were calculated as the ratio between affected versus non-affected hemifields and corresponding hemiretinas. Results: Retinal nerve fiber layer measurements in non-affected hemifields (mean [SD] 87.0 [17.1] mu m and 84.3 [20.2] mu m, for TD and SD-OCT, respectively) were thinner than in controls (119.0 [12.2] mu m and 117.0 [17.7] mu m, P<0.001). The optical coherence tomography normative database classified 42% and 67% of hemiretinas corresponding to non-affected hemifields as abnormal in TD and SD-OCT, respectively (P=0.01). Retinal nerve fiber layer measurements were consistently thicker with TD compared to SD-OCT. Retinal nerve fiber layer thickness asymmetry index was similar in TD (0.76 [0.17]) and SD-OCT (0.79 [0.12]) and significantly greater than the visual field asymmetry index (0.36 [0.20], P<0.001). Conclusions: Normal hemifields of glaucoma patients had thinner retinal nerve fiber layer than healthy eyes, as measured by TD and SD-OCT. Retinal nerve fiber layer measurements were thicker with TD than SD-OCT. SD-OCT detected abnormal retinal nerve fiber layer thickness more often than TD-OCT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose of this study was to evaluate the influence of miniscrew dental root proximity on its late stability degree. 40 miniscrews were inserted between maxillary second premolars and first molars for anterior retraction. Post-surgical radiographs were used to measure the septum width in the insertion site, insertion height, distal and mesial distance from miniscrew to dental root, and the smallest distance between miniscrew and dental root. The miniscrews were divided in two groups according to septum width: ?3 mm (20 miniscrews) and >3 mm (20 miniscrews). The soft tissue in the insertion site, sensitivity during load, plaque around the miniscrew, and evaluation period were also considered. The results showed no significant difference in miniscrew mobility degree and success rate between groups. Miniscrew dental root proximity did not influence the stability and success rate when the distance between the miniscrew and dental root indicated no periodontal ligament invasion. The overall success rate was 90% and no variable was associated with miniscrew failure. Nevertheless, patient sensitivity was frequently associated with some degree of mini-implant mobility. The septum width did not influence the stability and success rate of this anchorage system, but the extreme root proximity did.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: The aim of this prospective clinical study was to investigate the cephalometric changes produced by bonded spurs associated with high-pull chincup therapy in children with Angle Class I malocclusion and anterior open bite. Methods: Thirty patients with an initial mean age of 8.14 years and a mean anterior open bite of 3.93 mm were treated with bonded spurs associated with chincup therapy for 12 months. An untreated control group of 30 subjects with an initial mean age of 8.36 years and a mean anterior open bite of 3.93 mm and the same malocclusion was followed for 12 months for comparison. Student t tests were used for intergroup comparisons. Results: The treated group demonstrated a significantly greater decrease of the gonial angle, and increase in overbite, palatal tipping of the maxillary incisors, and vertical dentoalveolar development of the maxillary and mandibular incisors compared with the control group. Conclusions: The association of bonded spurs with high-pull chincup therapy was efficient for the correction of the open bite in 86.7% of the patients, with a 5.23-mm (SD, 61.69) overbite increase.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bone remodeling is affected by mechanical loading and inflammatory mediators, including chemokines. The chemokine (C–C motif) ligand 3 (CCL3) is involved in bone remodeling by binding to C–C chemokine receptors 1 and 5 (CCR1 and CCR5) expressed on osteoclasts and osteoblasts. Our group has previously demonstrated that CCR5 down-regulates mechanical loading-induced bone resorption. Thus, the present study aimed to investigate the role of CCR1 and CCL3 in bone remodeling induced by mechanical loading during orthodontic tooth movement in mice. Our results showed that bone remodeling was significantly decreased in CCL3−/− and CCR1−/− mice and in animals treated with Met-RANTES (an antagonist of CCR5 and CCR1). mRNA levels of receptor activator of nuclear factor kappa-B (RANK), its ligand RANKL, tumor necrosis factor alpha (TNF-α) and RANKL/osteoprotegerin (OPG) ratio were diminished in the periodontium of CCL3−/− mice and in the group treated with Met-RANTES. Met-RANTES treatment also reduced the levels of cathepsin K and metalloproteinase 13 (MMP13). The expression of the osteoblast markers runt-related transcription factor 2 (RUNX2) and periostin was decreased, while osteocalcin (OCN) was augmented in CCL3−/− and Met-RANTES-treated mice. Altogether, these findings show that CCR1 is pivotal for bone remodeling induced by mechanical loading during orthodontic tooth movement and these actions depend, at least in part, on CCL3.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho apresenta os resultados iniciais de uma pesquisa, descrevendo o comportamento de usuários de edifícios de escritórios em relação às temperaturas de acionamento de ventiladores e aparelhos condicionadores de ar. Medições foram realizadas em quatro salas administrativas do Instituto de Arquitetura e Urbanismo de São Carlos – IAU/USP, nas quais foram registradas as temperaturas internas do ar e o momento de acionamento dos referidos equipamentos. Os valores registrados foram comparados à temperatura externa e à faixa de temperaturas de conforto descrita pela norma ASHRAE 55/2004. As temperaturas registradas de acionamento dos aparelhos condicionadores de ar e ventiladores são similares e estão dentro da faixa considerada confortável pela referida norma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considerando a indisponibilidade de equipamentos avançados de aquisição de imagens nos centros cirúrgicos da maioria dos centros hospitalares e a importância fundamental que têm para o cirurgião uma visualização imediata do implante coclear logo após sua inserção, uma boa opção é a utilização da radiografia convencional. OBJETIVO: Descrever um método radiográfico rápido prático e de baixo custo, que permita avaliar não só a posição, mas também a integridade dos eletrodos, na instalação do implante coclear. MATERIAL E MÉTODO: Foram analisadas radiografias de 262 pacientes submetidos à cirurgia de implante coclear entre Março/2005 e Outubro/2008, com radiografia transoperatória, logo após a inserção dos eletrodos. As radiografias foram analisadas pelo cirurgião no transoperatório e, posteriormente, pelo médico radiologista. RESULTADOS: Foram analisadas 524 radiografias das quais, 95,61% apresentavam técnica adequada, com posicionamento do paciente dentro da técnica descrita neste estudo e boa visualização dos eletrodos, sendo consideradas satisfatórias e 4,39% apresentavam técnica inadequada e/ou visualização insatisfatória dos eletrodos, sendo consideradas insatisfatórias. CONCLUSÃO: Apesar dos aparelhos de Raios X portáteis possuírem limitações, utilizando técnicas e acessórios adequados, é possível conseguir radiografias com resultados satisfatórios para visualização dos implantes cocleares.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Devido aos avanços na tecnologia dos implantes cocleares e das estratégias de processamento, indivíduos com surdez grave a profunda puderam ouvir sons e reconhecer fala em diferentes graus. A variabilidade nos resultados audiológicos em portadores de surdez pós-lingual tem sido grande e a indicação para o implante coclear tem se estendido e inclui uma população cada vez maior. OBJETIVO: Avaliar em quais pacientes portadores de surdez pós-lingual o implante coclear traz benefício auditivo superior ao da prótese auditiva convencional. MATERIAIS E MÉTODOS: consulta a artigos científicos por busca no banco de dados SciELO, Cochrane, MEDLINE e LILACS-BIREME. Foram selecionadas publicações com força de evidência A ou B até a data da investigação, que comparassem aparelhos de amplificação sonora e implante coclear na população com surdez pós-lingual. Desenho do Estudo: revisão sistemática. RESULTADOS: Entre os 2169 artigos consultados, 11 trabalhos se mostram pertinentes ao tema e apresentaram força de evidência B. Seis estudos são do tipo coorte prospectivo, quatro são estudos transversais e um ensaio clinico. CONCLUSÃO: A avaliação dos benefícios obtidos por portadores de surdez pós-lingual reabilitados com o uso de implante coclear mostra que este dispositivo é efetivo e apresenta melhores resultados quando comparado aos aparelhos de amplificação sonora individual.