899 resultados para Absorptiometry, Photon


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Myocardial Perfusion Gated Single Photon Emission Tomography (Gated-SPET) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV). The purpose of this study is to evaluate the influence of the total number of counts acquired from myocardium, in the calculation of myocardial functional parameters using routine software procedures. Methods: Gated-SPET studies were simulated using Monte Carlo GATE package and NURBS phantom. Simulated data were reconstructed and processed using the commercial software package Quantitative Gated-SPECT. The Bland-Altman and Mann-Whitney-Wilcoxon tests were used to analyze the influence of the number of total counts in the calculation of LV myocardium functional parameters. Results: In studies simulated with 3MBq in the myocardium there were significant differences in the functional parameters: Left ventricular ejection fraction (LVEF), end-systolic volume (ESV), Motility and Thickness; between studies acquired with 15s/projection and 30s/projection. Simulations with 4.2MBq show significant differences in LVEF, end-diastolic volume (EDV) and Thickness. Meanwhile in the simulations with 5.4MBq and 8.4MBq the differences were statistically significant for Motility and Thickness. Conclusion: The total number of counts per simulation doesn't significantly interfere with the determination of Gated-SPET functional parameters using the administered average activity of 450MBq to 5.4MBq in myocardium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has been pointed out recently that current experiments still allow for a two Higgs doublet model where the hbb¯ coupling (kDmb/v) is negative; a sign opposite to that of the Standard Model. Due to the importance of delayed decoupling in the hH+H− coupling, h→γγ improved measurements will have a strong impact on this issue. For the same reason, measurements or even bounds on h→Zγ are potentially interesting. In this article, we revisit this problem, highlighting the crucial importance of h→VV, which can be understood with simple arguments. We show that the impacts on kD<0 models of both h→bb¯ and h→τ+τ− are very sensitive to input values for the gluon fusion production mechanism; in contrast, h→γγ and h→Zγ are not. We also inquire if the search for h→Zγ and its interplay with h→γγ will impact the sign of the hbb¯ coupling. Finally, we study these issues in the context of the flipped two Higgs doublet model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the first in vivo studies of cerebral function with radionuclides by Ingvar and Lassen, nuclear medicine (NM) brain applications have evolved dramatically, with marked improvements in both methods and tracers. Consequently it is now possible to assess not only cerebral blood flow and energy metabolism but also neurotransmission. Planar functional imaging was soon substituted by single-photon emission computed tomography (SPECT) and positron emission tomography (PET); it now has limited application in brain imaging, being reserved for the assessment of brain death.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Brain dopamine transporters imaging by Single Photon Emission Tomography (SPECT) with 123I-FP-CIT has become an important tool in the diagnosis and evaluation of parkinsonian syndromes, since this radiopharmaceutical exhibits high affinity for membrane transporters responsible for cellular reabsorption of dopamine on the striatum. However, Ordered Subset Expectation Maximization (OSEM) is the method recommended in the literature for imaging reconstruction. Filtered Back Projection (FBP) is still used due to its fast processing, even if it presents some disadvantages. The aim of this work is to investigate the influence of reconstruction parameters for FBP in semiquantification of Brain Studies with 123I-FPCIT compared with those obtained with OSEM recommended reconstruction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Myocardial perfusion imaging (MPI) is used on a daily basis to access coronary blood flow in patients that are suspected or have known Coronary Artery Disease (CAD). A Single Photon Emission Computed Tomography (SPECT) or and Positron Emission Tomography (PET) scan are used to access regional blood flow quantification either at rest or stress, the imaging acquisition is connected to an Electrocardiogram (ECG) and it is able to determine and quantify other myocardial parameters like myocardial wall thickness and wall motion. PET is not used so broadly due to its high procedure cost, the proximity with cyclotron, where are produced the majority of radiopharmaceuticals used in PET, due to their shor thalf-life. This work is intended to carry out a review of the tests relating to radiopharmaceuticals that are used in clinical practice in SPECT or PET for assessment of myocardial perfusion, also focusing very promising radiopharmaceuticals that are under investigation or in clinical trials with great potential for conventional nuclear medicine or PET, proceeding to a comparative analysis of both techniques and respective radiopharmaceuticals used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The acquisition of a Myocardial Perfusion image (MPI) is of great importance for the diagnosis of the coronary artery disease, since it allows to evaluate which areas of the heart aren’t being properly perfused, in rest and stress situations. This exam is greatly influenced by photon attenuation which creates image artifacts and affects quantification. The acquisition of a Computerized Tomography (CT) image makes it possible to get an atomic images which can be used to perform high-quality attenuation corrections of the radiopharmaceutical distribution, in the MPI image. Studies show that by using hybrid imaging to perform diagnosis of the coronary artery disease, there is an increase on the specificity when evaluating the perfusion of the right coronary artery (RCA). Using an iterative algorithm with a resolution recovery software for the reconstruction, which balances the image quality, the administered activity and the scanning time, we aim to evaluate the influence of attenuation correction on the MPI image and the outcome in perfusion quantification and imaging quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Thesis submitted for the co-tutelle degree of Doctor in Physics at Universidade Nova de Lisboa and Université Pierre et Marie Curie

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 50-year-old post-menopausal recipient of a kidney allograft with bone pain, osteoporosis, persistent hypercalcaemia and elevated parathormone (PTH) levels, despite a satisfactory graft function, was treated with bisphosphonates and cinacalcet starting, respectively, 5 and 6 months after renal transplantation (RT). Sixteen months after treatment, there was improvement of bone mineral density (BMD) measured by dualenergy X-ray absorptiometry (DEXA). A bone biopsy was taken, unveiling a surprising and worrisome result. Post-RT bone disease is different from classic CKD-MBD and should be managed distinctly, including, in some difficult cases, an invasive evaluation through the performance of a bone biopsy, as suggested in the KDIGO guidelines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Millions of children are infected by enteroviruses each year, usually exhibiting only mild symptoms. Nevertheless, these viruses are also associated with severe and life-threatening infections, such as meningitis and encephalitis. We describe a 32-month-old patient with enteroviral encephalitis confirmed by polymerase chain reaction in cerebrospinal fluid, with unfavorable clinical course with marked developmental regression, autistic features, persistent stereotypes and aphasia. She experienced slow clinical improvement, with mild residual neurologic and developmental deficits at follow-up. Viral central nervous system infections in early childhood have been associated with autism spectrum disorders but the underlying mechanisms are still poorly understood. This case report is significant in presenting a case of developmental regression with autistic features and loss of language improving on follow-up. To our knowledge, this is the first published report of enterovirus encephalitis leading to an autism spectrum disorder.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Lipodystrophy is related to the use of highly active antiretroviral therapy (HAART) and can cause aesthetic stigma and increase the risk of developing cardiovascular diseases. Physical activity may be a valid alternative for the treatment and prevention of lipodystrophy. However, few studies address this issue. The objective of this study was to assess lipodystrophy related to highly active antiretroviral therapy in HIV/AIDS patients with different physical activity habits. METHODS: The sample was composed of 42 HIV/AIDS patients taking HAART medication who were visiting the Counseling and Testing Center (CTC) in Presidente Prudente. The level of physical activity was obtained using the International Physical Activity Questionnaire (IPAQ); lipodystrophy was diagnosed using a self-report questionnaire that was administered to the patient and then followed up by medical confirmation. The percentage of trunk fat was estimated by dual X-Ray absorptiometry (DEXA). Information about sex, age, length of HAART treatment, CD4+ T lymphocyte count (CD4) and viral load was also collected. RESULTS: A higher prevalence of lipodystrophy was observed in the sedentary group when compared to the physically active group, which indicates that physical activity may be a protective factor in relation to the occurrence of lipodystrophy. The group that had a higher CD4 had a higher proportion of lipodystrophy and a higher proportion of younger and physically active individuals. The patients with lipodystrophy had a higher percentage of trunk fat and were more sedentary than active individuals. CONCLUSIONS: A physically active lifestyle has a protective effect against the occurrence of lipodystrophy related to HAART.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To find sustainable solutions for the production of energy, it is necessary to create photovoltaic technologies that make every photon count. To pursue this necessity, in the present work photodetectors of zinc oxide embedded with nano-structured materials, that significantly raise the conversion of solar energy to electric energy, were developed. The novelty of this work is on the development of processing methodologies in which all steps are in solution: quantum dots synthesis, passivation of their surface and sol-gel deposition. The quantum dot solutions with different capping agents were characterized by UVvisible absorption spectroscopy, spectrofluorimetry, dynamic light scattering and transmission electron microscopy. The obtained quantum dots have dimensions between 2 and 3nm. These particles were suspended in zinc acetate solutions and used to produce doped zinc oxide films with embedded quantum dots, whose electric response was tested. The produced nano-structured zinc oxide materials have a superior performance than the bulk, in terms of the produced photo-current. This indicates that an intermediate band material should have been produced that acts as a photovoltaic medium for solar cells. The results are currently being compiled in a scientific article, that is being prepared for possible submission to Energy and Environmental Science or Nanoscale journals.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of organic materials displaying high two-photon absorption (TPA) has attracted much attention in recent years due to a variety of potential applications in photonics and optoelectronics, such as three-dimensional optical data storage, fluorescence imaging, two-photon microscopy, optical limiting, microfabrication, photodynamic therapy, upconverted lasing, etc. The most frequently employed structural motifs for TPA materials are donor–pi bridge–acceptor (D–pi–A) dipoles, donor–pi bridge–donor (D–pi–D) and acceptor–pi bridge-acceptor (A–pi–A) quadrupoles, octupoles, etc. In this work we present the synthesis and photophysical characterization of quadrupolar heterocyclic systems with potential applications in materials and biological sciences as TPA chromophores. Indole is a versatile building block for the synthesis of heterocyclic systems for several optoelectronic applications (chemosensors, nonlinear optical, OLEDs) due to its photophysical properties and donor electron ability and 4H-pyran-4-ylidene fragment is frequently used for the synthesis of red light-emitting materials. On the other hand, 2-(2,6-dimethyl-4H-pyran-4-ylidene)malononitrile (1) and 1,3-diethyl-dihydro-5-(2,6-dimethyl-4H-pyran-4-ylidene)-2-thiobarbituric (2) units are usually used as strong acceptor moieties for the preparation of π-conjugated systems of the push-pull type. These building blocks were prepared by Knoevenagel condensation of the corresponding ketone precursor with malononitrile or 1,3-diethyl-dihydro-2-thiobarbituric acid. The new quadrupolar 4H-pyran-4-ylidene fluorophores (3) derived from indole were prepared through condensation of 5-methyl-1H-indole-3-carbaldehyde with the acceptor precursors 1 and 2, in the presence of a catalytical amount of piperidine. The new compounds were characterized by the usual spectroscopic techniques (UV-vis., FT-IR and multinuclear NMR - 1H, 13C).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector using proton–proton collision data with a centre-of-mass energy of s√=7 TeV corresponding to an integrated luminosity of 4.7 fb −1 . Jets are reconstructed from energy deposits forming topological clusters of calorimeter cells using the anti- kt algorithm with distance parameters R=0.4 or R=0.6 , and are calibrated using MC simulations. A residual JES correction is applied to account for differences between data and MC simulations. This correction and its systematic uncertainty are estimated using a combination of in situ techniques exploiting the transverse momentum balance between a jet and a reference object such as a photon or a Z boson, for 20≤pjetT<1000 GeV and pseudorapidities |η|<4.5 . The effect of multiple proton–proton interactions is corrected for, and an uncertainty is evaluated using in situ techniques. The smallest JES uncertainty of less than 1 % is found in the central calorimeter region ( |η|<1.2 ) for jets with 55≤pjetT<500 GeV . For central jets at lower pT , the uncertainty is about 3 %. A consistent JES estimate is found using measurements of the calorimeter response of single hadrons in proton–proton collisions and test-beam data, which also provide the estimate for pjetT>1 TeV. The calibration of forward jets is derived from dijet pT balance measurements. The resulting uncertainty reaches its largest value of 6 % for low- pT jets at |η|=4.5 . Additional JES uncertainties due to specific event topologies, such as close-by jets or selections of event samples with an enhanced content of jets originating from light quarks or gluons, are also discussed. The magnitude of these uncertainties depends on the event sample used in a given physics analysis, but typically amounts to 0.5–3 %.