971 resultados para ANALYTICAL-CHEMISTRY


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The (1) H and C-13 NMR spectra are reported for Ru(4, 4'-dimethyl-2,2'-bipyridene)(2) (2,2'-bipyridine-4,4'-dicarboxylic acid) (PF6)(2) that can be used as a new electrochemiluminescent probe in immunoasssay and nucleic acid hybridization assay. Because of the effect ol:Ru atom ligands and complex steric configuration, it is difficult to attribute spectra of the title molecular, By using 2D (1) H-(1) H COSY and (1) H-C-13 HETCOR method, the proton and C-13 NMR spectra are assigned completely, which provides a satisfactory method to quantitative and qualitative, analysis of the title moleculer in the further study.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The basic principle, instrumentation and recent advances of scanning electrochemical microscopy are briefly reviewed with 55 references.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Magnetic microsphere comprises a magnetically responsive metal or metal oxide core surrounded by a polymer shell with active groups. Nowadays, methods of directly coating polymer, monomer polymerazation, impregnation, extrusion and biological synthesis are generally used to prepare magnetic particles. This kind of superparamagnetic microspheres can be attached to chemical, biochemical and biological substances by their active groups, then applying a magnetic field to separate from the media. Preparation and utilization of magnetic microspheres in immunoassay, nucleic acid hybrization assay, gene sequencing, cell isolation, enzyme immoblization, receptor isolation and other Gelds are reviewed with 44 references in this paper. Also, the further development is outlooked.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

End-column amperometric detection of 6-mercaptopurine by capillary zone electrophoresis was described with high resolution and speed. The detection conditions were optimized and the electrochemical behavior was observed. Under the optimal conditions: detection potential of 1.2 V ( vs. Ag/AgCl), operating voltage of 15 kV, sample injection of 3 s at 15 kV and 10 mmol/l Na2HPO4 buffer, the detection limit for 6-MP was as low as 1 x 10(-7) mol/L and the linear range was from 5 x 10(-4) to 5 x 10(-6) mol/L with the relative coefficient of 0.995. The RSD of reproducibility for peak current and migration time was 2.5% and 1.2%, respectively. This method was utilized in assay real sample of human mine and bovine serum albumin containing 6-mercaptopurine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The anodic voltammetric behavior of anaesthetic tetracine and its application were studied. In 0.1 mol/L HClO4 solution, the potential of anodic peak for tetracine is 1.04 V(vs. Ag/AgCl) at a glassy carbon electrode. A linear relationship between the peak height and the concentration of tetracine in the range of 5 x 10(-4) similar to 1 x 10(-1) g/L was obtained. The peak current decreases with the decreasing acidity of the solution. the mehtod has been used for the direct determination of tetracine in injections. The average recoveries of tetracine in urine samples were 98.5%. The mechanism of the electrode reaction was also discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The recent progress in electrochemiluminescent (ECL) assay is reviewed. This review begins with the fundamental researches in ECL, including the discovery of new ECL-active species, such as biochemical, organic and metallorganic materials, digital modeling of ECL process, the flow cells used in ECL assay, and electrochemiluminescent sensor. The application of ECL in environmental analysis, immunoassay, nucleotide acid hybridization sensor. The applications of ECL in environmental analysis, immunooassay, nucleic acid hybridization assay, and other aspects are reviewed with the latest references in detail. Finally, the main problems in the further investigation are outlooked, so are its prospects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ephedrine and isoephedrine were first distingshed by electrospy ionization mass spectrometry and in-sourice collision-induced dissociation technique. Based on this observation, a unkown sample was identified for ephedrine.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The H-1 and C-13 nuclear magnetic resonance(NMR) spectra are reported for bis(2, 2'-bipyridine)(2, 2'-bipyridine-,4,4'-dicarboxylic acid) ruthenium(II) hexafluoruphosphate that has been used as a tagged molecule of electrochemiluminescent immunoassay. Because of the effect of Ru atom on ligands, it is difficult to assign its NMR spectra. BS' means of two dimensional H-1-H-1 COSY and H-1-C-13 COSY techniques, the H-1 and C-13 NMR spectra of bis (2, 2'-bipylidine) (2, 2'-bipyridine-4, 4-dicarboxylic acid) ruthenium(II) hexafluorophosphate are assigned completely. This provides a basis for NMR characterization of the nerv similar tagged molecules.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Acetone and dimethyl ether( DME) have been shown to be reagent gases of exceptional utitlity and versatility for the characterization of a variety of class of organic compounds. The fragmentation mechanisms of the adduct product ions, formed by ion/molceule reaction of the substrate with the ionized gases, have been studied and substantiated by experiments with acetone-d(6) and DME-d(6).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Chemical structure of fulvic acids extracted from composted corn stalk residue(CSR FA)was studied by Fourier transform infrared (FTIR) spectroscopy, H-1 and C-13 nuclear magnetic resonance(H-1-NMR, C-13-NMR) spectroscopy. The results show that CSR FA mainly consists of four types of carbon: carbonyl, aromatical, alkyl and carbohydrate, the carbohydrate is dominant. Its aromaticity is 15.42%, less than that of CSR HA. This indicates that the construction of CSR FA is simpler than that of CSR HA, FA can not be extracted from undecomposed corn stalk residue. CSR FA may be formed by cellulose or hemicellulosemorties combined with aromatic compound from decomposed lignin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Selectivity coefficient measurement has been performed for K+,Ni2+,Fe3+ with Nafion 117 perfluorosulfonate polymer as-received forms. The results show that a linear Nernst response is exhibited for H+,K+,Pb2+,Ni2+,Co2+,Fe3+, and the ion selectivity coefficient of Nafion membrane for KC is better than Ni2+ and Fe3+.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

yA review with 44 references is presented on the development of sol-gel-based biosensor. The main discussions are devoted to the process, advantages and properties of sol-gel immobilization method, sol-gel optical biosensor and amperometric biosensor, also the trend in this field is forecasted.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The cyclic aryletherketone( sulfone) oligomers containing hexafluoroisopropylidene unit were characterized by matrix-assisted laser desorption ionization time-of-night mass spectrometry(MALDI-TOF-MS) using Na+ and Ag+ as cationization agents. The affinities of cyclic oligomers to the cation were studied. The analysis result showed that 1,8,9-dithranol, in the presence of silver trifluoroacetate, was very effective for the characterization of cyclic arylether ketone ( sulfone) containing hexafluoroisopropylidene unit.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purity and molecular weight of calmodulin have been determined by means of matrix-assisted laser desorption/ionization time of flight mass spectrometry, and the results have been discussed. The experimental results demonstrate that this method is high sensitive and rapid as compared with other traditional methods.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A method for the determiantion of rare earth elements in biological sampels by inductively coupled plasma mass spectrometry was developed. Oxide ion yield of the rare earth elements (RFE) decreased with the increasing of RF power and the sampling depth, or with the decreasing of carrier gas flow rate. The spectral interference arising from (PrO)-Pr-141-O-16 on Gd-157 must be corrected. if the concentration of Ba was high enough, it was necessary to correct the spectral interference arising from (BO)-B-135-O-16 on Eu-151, and it was not necessary to correct spectral interference arising from (NdO)-Nd-143-O-16 on Tb-159 etc. in the biological samples under the selected operation parameters. In the biological sample, the major matrix elements, such as K, Na and Ca, result in the suppression of REEs signals and the suppression degree of the Ca is grezter than that of the K and Na. The mussel sample was digested by thd dry ashing, wet digestion with HNO3 + H2O2 and HNO3 + HClO4, respectively. The analytical results of REEs were consistent with each other. Detection limits for REEs are 0.001 similar to 0.013 mu g/L. Recoveries of standard addition are 91.7% similar to 125%. REEs in biological samples were determined directly without separation and preconcentration procedure.